Professional Documents
Culture Documents
Footing No. F8
fy 415 N/mm^2
fck 25 N/mm^2
Cover 50 mm
Dia of bar 12 mm
SBC of soil taken in the design: 12.00 T/m^2 (At 1.5 m depth from NGL)
CALCULATION OF FOUNDATION:
m m
Column size = 0.3 x 0.8
Vertical Forces (P1) = 27.00 t (From STAAD)
Net Upward pressure (Calculated)_q = P/A +- M/Z, Z=bd2/6 Since, Z = 9.750 m^3
Shear at d from face of the beam = Shear Strength CHECK AGAINST SLIDING:
2950 - d x 6.65 x 10^4 = 1000 x d x 0.42 Vertical Forces = 27.00 t (From STAAD)
1000
d = 403 mm Soil/concrete load over footing = 180.00 t
BM per m width = q*L^2/2 = 28.92 Mton-m Total Horizontal Force tending to slide = 0.5 * y * H^2 * Ka = 1.50 t
_DEPTH REQUIRED FROM PUNCHING SHEAR: FOS against Sliding = 0.33 * 207.00 / 1.50 = 45.43 >1.5, SAFE
1 650 12 594 50 2950 28.92 13.67 4.63 Cm^2/m Effective depth required (d) = 463.92 Overall Depth required (D) = 501.42 Provide, D = 450 mm
Reinforcement Provided at Bottom in Trnseverse dir : 1. Moment due to Eccentricity = 29.70 Mton-m
Dia C/C Ast Dia C/C Ast Dia C/C_mm Ast_Cm^2 Total_As
_mm _Cm^2 _mm _Cm^2 t Clear
D Bar dia d b Mu Ast
_Cm^2 cover
S.No.
12 125 9.05 0 1 0.00 0 1 0.00 9.05 Cm^2/m (mm) (mm) (mm) (mm) (mm) (Mton-m) (Cm2)
O.K. 1 450 25 413 25 600 29.70 41.45
CALCULATION OF FOUNDATION:
m m
Column size = 0.23 x 0.35
Vertical Forces (P1) = 27.00 t (From STAAD)
Net Upward pressure (Calculated)_q = P/A +- M/Z, Z=bd2/6 Since, Z = 4.688 m^3
Shear at d from face of the beam = Shear Strength CHECK AGAINST SLIDING:
1950 - d x 12.89 x 10^4 = 1000 x d x 0.42 Vertical Forces = 27.00 t (From STAAD)
1000
d = 458 mm Soil/concrete load over footing = 45.00 t
BM per m width = q*L^2/2 = 24.50 Mton-m Total Horizontal Force tending to slide = 0.5 * y * H^2 * Ka = 1.19 t
_DEPTH REQUIRED FROM PUNCHING SHEAR: FOS against Sliding = 0.33 * 72.00 / 1.19 = 20.00 >1.5, SAFE
1 550 12 494 50 1950 24.50 11.69 6.00 Cm^2/m Effective depth required (d) = 458.61 Overall Depth required (D) = 496.11 Provide, D = 450 mm
Reinforcement Provided at Bottom in Trnseverse dir : 1. Moment due to Eccentricity = 29.03 Mton-m
Dia C/C Ast Dia C/C Ast Dia C/C_mm Ast_Cm^2 Total_As
_mm _Cm^2 _mm _Cm^2 t Clear
D Bar dia d b Mu Ast
_Cm^2 cover
S.No.
10 125 6.28 0 1 0.00 0 1 0.00 6.28 Cm^2/m (mm) (mm) (mm) (mm) (mm) (Mton-m) (Cm2)
O.K. 1 450 25 413 25 600 29.03 33.16
CALCULATION OF FOUNDATION:
m m
Column size = 0.345 x 0.6
Vertical Forces (P1) = 12.00 t (From STAAD)
Net Upward pressure (Calculated)_q = P/A +- M/Z, Z=bd2/6 Since, Z = 2.160 m^3
Shear at d from face of the beam = Shear Strength CHECK AGAINST SLIDING:
952.5 - d x 15.42 x 10^4 = 1000 x d x 0.42 Vertical Forces = 12.00 t (From STAAD)
1000
d = 256 mm Soil/concrete load over footing = 37.80 t
BM per m width = q*L^2/2 = 7.00 Mton-m Total Horizontal Force tending to slide = 0.5 * y * H^2 * Ka = 3.64 t
_DEPTH REQUIRED FROM PUNCHING SHEAR: FOS against Sliding = 0.33 * 49.80 / 3.64 = 4.52 >1.5, SAFE
1 325 12 269 50 952.5 7.00 6.29 6.60 Cm^2/m Effective depth required (d) = 368.93 Overall Depth required (D) = 399.93 Provide, D = 450 mm
Reinforcement Provided at Bottom in Trnseverse dir : 1. Moment due to Eccentricity = 10.80 Mton-m
Dia C/C Ast Dia C/C Ast Dia C/C_mm Ast_Cm^2 Total_As
_mm _Cm^2 _mm _Cm^2 t Clear
D Bar dia d b Mu Ast
_Cm^2 cover
S.No.
10 110 7.14 0 1 0.00 0 1 0.00 7.14 Cm^2/m (mm) (mm) (mm) (mm) (mm) (Mton-m) (Cm2)
O.K. 1 450 12 419 25 345 10.80 10.38
CALCULATION OF FOUNDATION:
m m
Column size = 0.3 x 0.6
Vertical Forces (P1) = 7.00 t (From STAAD)
Net Upward pressure (Calculated)_q = P/A +- M/Z, Z=bd2/6 Since, Z = 1.067 m^3
Shear at d from face of the beam = Shear Strength CHECK AGAINST SLIDING:
650 - d x 14.55 x 10^4 = 1000 x d x 0.42 Vertical Forces = 7.00 t (From STAAD)
1000
d = 167 mm Soil/concrete load over footing = 17.60 t
BM per m width = q*L^2/2 = 3.07 Mton-m Total Horizontal Force tending to slide = 0.5 * y * H^2 * Ka = 2.25 t
_DEPTH REQUIRED FROM PUNCHING SHEAR: FOS against Sliding = 0.33 * 24.60 / 2.25 = 3.61 >1.5, SAFE
1 250 12 194 50 650 3.07 3.88 5.97 Cm^2/m Effective depth required (d) = 266.49 Overall Depth required (D) = 297.49 Provide, D = 450 mm
Reinforcement Provided at Bottom in Trnseverse dir : 1. Moment due to Eccentricity = 4.90 Mton-m
Dia C/C Ast Dia C/C Ast Dia C/C_mm Ast_Cm^2 Total_As
_mm _Cm^2 _mm _Cm^2 t Clear
D Bar dia d b Mu Ast
_Cm^2 cover
S.No.
10 125 6.28 0 1 0.00 0 1 0.00 6.28 Cm^2/m (mm) (mm) (mm) (mm) (mm) (Mton-m) (Cm2)
O.K. 1 450 12 419 25 300 4.90 4.33