AC/DC Clamp Meter


DC Current :
Ranges Resolution Accuracy
400A 0.1A ±(1.5%rdg+4dgt)
600A 1A ±(2.0%rdg+4dgt)
Resistance:
Ranges Resolution Accuracy
400Ω 0.1Ω
4kΩ 1Ω
40kΩ 10Ω ±(1.5%rdg+3dgt)
400kΩ 100Ω
4MΩ 1kΩ
40MΩ 10kΩ ±(2.0%rdg+4dgt)
Continuity:
Ranges Audible threshold
2660 CL 400Ω Less than 35Ω
Frequency:
FEATURES Ranges Resolution Accuracy
●●4000 counts.
●●Voltage measurement, current measurement, resistor 4kHz 1Hz
±(0.3%rdg+2dgt)
measurement, frequency counter, capacitor measure- 15kHz 10Hz
ment. Diode:
●●Bargraph indication.
●●Range change function. Ranges Resolution Accuracy
●●Data hold function freezes the reading. 2V 1mV ±(1.5%rdg+3dgt)
●●REL function.
●●Peak function. Capacitor:
●●Diode measurement. Ranges Resolution Accuracy
●●Max / Min function. 4nF 1pF ±(2.5%rdg+4dgt)
●●Continuity check. 40nF 10pF
●●Low battery indication.
●●Auto Power Off (APO) function. 400nF 100pF
±(2.0%rdg+4dgt)
●●Safety design throughout with no exposed metal 4µF 1nF
parts, shielded banana plugs and recessed input termi- 40µF 10nF
nals. 400µF 100nF
±(2.5%rdg+4dgt)
SPECIFICATIONS 4mF 1µF
40mF 10µF ±(3.0%rdg+4dgt)
DC Voltage :
Ranges Resolution Accuracy GENERAL
400mV 0.1mV Conductor size 35mm Max.
4V 1mV Operating principle Dual slope integration
40V 10mV ±(1.0%rdg+3dgt) Over range indication "O.L" indicated
400V 100mV Low battery indication
600V 1V Response time Approx. 1 second
●Overload protection : 650V DC Sample rate Approx. 2 times per second
Temperature &
AC Voltage : humidity for
0ºC to 50ºC
Ranges Resolution Accuracy 80% Max.
guaranteed
400mV 0.1mV ±(2.0%rdg+3dgt) Storage temperature -10ºC to 60ºC
4V 1mV & humidity 80% Max.
40V 10mV Approx.100 hours on
±(1.5%rdg+3dgt) Battery life
400V 100mV continuous use. (Alkaline)
600V 1V Dimensions 210(L) × 90(W) × 40(D)mm
●Overload protection : 650V AC rms Weight
Approx. 330g
●Frequency Response : 0~400mV at 40Hz~120Hz (battery Included)
4V~600V at 40Hz~500Hz One type 6F22
Power source
(or equivalent), 9V manganese
AC Current : EN 61010-1 CAT III 600V
Safety standard
Ranges Resolution Accuracy EN 61326-1
400A 0.1A ±(1.5%rdg+4dgt) Instruction manual Test leads
Accessories
600A 1A ±(2.0%rdg+4dgt) Soft pouch Battery
●Frequency Response: 40Hz~500Hz