You are on page 1of 1

Job No.

: 230300SG0105264
Date : August 3rd, 2023
Page : 1 of 1

REPORT OF LABORATORY ANALYSIS


Sample No. : 5739
Sample ID : PT. GIP
Client : PT. GLORY IRFAN PERKASA
Attention : Mr. Dedi Irawan
Address : Jl. Sungai Ampal Balikpapan Baru Komp. Pasar Segar Blok. BMC - 03 RT. 000 RW. 000
Consignment : Coal Sample
Date Received : July 31st, 2023
Date Tested : August 2nd, 2023
Sample Weight : 12.96 Kg
Tested For : Total Moisture, Inherent Moisture, Ash, Volatile Matter, Fixed Carbon, Total Sulfur,
Gross Calorific Value, Hardgrove Grindability Index.

THIS IS TO REPORT that upon the request of the principal, The sample received was prepared and analyzed
according to ASTM Standard with specifications shown as below:
Basis
Parameter Unit ARB ADB DB DAF Standard Method
1.Total Moisture % 4.94 - - - ASTM-D3302
2.Inherent Moisture % - 4.24 - - ASTM-D3173
3.Ash % 11.11 11.19 11.69 - ASTM-D3174
4.Volatile Matter % 41.79 42.10 43.96 49.78 ASTM-D3175
5.Fixed Carbon % 42.16 42.47 44.35 50.22 By Difference
6.Total Sulfur % 1.11 1.12 1.17 1.32 ASTM-D4239
7.Gross Calorific Value kcal/kg 6573 6621 6914 7829 ASTM-D5865
8.HGI index 46 ASTM-D409
Note : ARB= As Received Basis ; ADB=Air Dried Basis ; DB=Dry Basis ; DAF=Dry Ash-Free ; (-)=Not Analyzed

This Report reflects our findings at time and place of analysis only and does not report any other matters.
This Report refers to the tested sample only and is issued without prejudice.

FOR AND ON BEHALF OF PT. CCIC JAKARTA

Zhou Yong
Lab Manager
Banjarmasin Branch