Specifications
Weight
3·2kg (7lb 2oz).
Detector
Halogen quenched GM tube.
Calibration
Caesium-137 GM tube.
Radiation detected
Gamma 100keV to 1·3MeV.
Saturation test
400Sv/h (40kR/h) at 1·3 MeV.

Charger, code TANC492


for use with TANB492
Specifications
Gammalarm,™ code TANB492 (240V) Input
and code TAN4920 (110V) 240 volts AC.
The Gammalarm is of rugged design and compact Output
construction for use on-site. It provides a continuous 13·8 volts DC.
highly visible indication of the environmental radiation
Weight
field. It is fitted with a heavy-duty guard to protect
1·5Kg (3·3lb).
the indicator lamps during transportation. A connector
is fitted to allow recharging via purpose-built charger Charger, code TANC4920
units (ordered separately).
for use with TAN4920
Use Specifications
When the alarm is switched on, radiation below Input
threshold (8µsv/h) is indicated by an amber flashing 110 volts AC.
lamp. An audible alarm pre-warning of radiation Output
exposure is initiated by a push button switch. This will 13·8 volts DC.
automatically terminate as soon as radiation is above
threshold. Radiation above threshold is indicated by a Weight
red flashing lamp. 1·5Kg (3·3lb).

Return to contents
Gammalarm, code TAND492 Dual light flasher, code TANE492
The alarm is compact and can be shelf-mounted or This attachment or slave unit connects directly to the
set on any relatively level surface for quick easy Gammalarm TAND492 by electrical cable for remote
installation, with the additional facility of fail safe signalling of the radiation field level. It has a rugged
circuitry. It provides a continuous highly visible steel case with heavy duty glass red and green
indication of the environmental radiation field. lamp domes.
Auxiliary connector sockets are incorporated in
the Gammalarm to facilitate the addition of options Audible alarm, code TANH492
such as slave unit, additional light flashers, audible
This unit can be connected to the Gammalarm
alarms, automatic door locks, etc.
TAND492 to provide you with an audible indication
Maintenance is generally limited to simple
of when the preset detection level is reached.
lamp replacement and periodic detector level
The audible signal is a variable time buzzer with an
(or sensitivity) adjustment.
adjustable initial warning signal period of 0·5 to 30
seconds before reverting to a lower volume or off.
Use A continuous alert signal can be provided on
The safe condition is indicated by a continuous green special request.
lamp and can be preset to trip to the hazard condition
indicated by a flashing red lamp. The threshold for Safety monitor circuit, code TANJ492
the alarm trip can be varied from 20 to 350µSv/h,
This special self-contained circuit arrangement is
(2 to 35mR/h). The red light flashes at a rate of
triggered by the 110 volts provided by the Gammalarm
approximately 60 flashes per minute.
TAND492, when in the hazard condition. The circuit
Failure of any signalling element in the circuitry
provides a number of low voltage (as well as 110 volts)
either turns on the red warning light or turns off both
signals to operate safety devices in the radiography area.
lights to warn the radiographer. The green light
These could be horns, door locks, lights or interrupt
therefore not only shows that the radiation level is safe
switches, for example, to prevent the opening of a door
but also shows the system circuitry to be functioning
to the radiation area.
normally. A small caesium-137 source provides a
constant monitor for the Geiger Mueller tube, so that
any circuit breakdown is immediately detected. Junction box, code TANK492
This unit when used in conjunction with the
Specifications Gammalarm TAND492 makes possible the operation
Dimensions of up to four separate dual light flashers TANE492
Length: 305mm (12in). from a single Gammalarm.
Width: 152mm (6in).
Height: 330mm (13in). Survey meter calibrator, code TMN773
Weight: 5·4kg (12lb).
This device is designed for the rapid and accurate
Internal source calibration of radiation survey meters. The unit is
333kBq, 9µCi caesium-137. ruggedly constructed and lockable when not in use.
Detector It has a 810GBq, 150mCi caesium-137 source.
GM tube.
Radiation detected Optional additional Safety
door
interlock
80keV to 1·5MeV Gamma. devices for use
with the SENTINEL
Red hazard bulb Monitor Other
Gammalarm TAND492 circuit warning
150 watt 115 volts AC. TANJ492 systems

Green safe bulb


15 watt 115 volts AC. Remote Audible alarm
flashers Gammalarm Buzzer/Siren
TAND492
Case TANE492 TANH492

Aluminum.
Remote
probes
Supply voltage TANF492

115 volts AC, 60 c/s. (220/240 volts optional).


QSA/Sentinel/USDS009(9/99)