You are on page 1of 12

B.

Atomic Absorption Spectrophometry


Practice Exam C. Dilution Technique
D. Colometric Method
All premises intended for human use or habitation
shall be provided with a supply of pure and The Silver Diethyldithiocarbamate (SDDC) Method
wholesome water, neither connected to unsafe is a widely used colorimetric technique for the
determination of arsenic in aqueous samples.
water supply nor subject to backflow or
Although it is sensitive enough for the low-level
_____________.* determination of arsenic in drinking water,
A. reverse flow expensive instrumentation is not required.
B. back-siphonage
C. back flow The method used in the water BOD content test is
D. counterflow the winkler method, while the water COD content
test is the spectrophotometric method. The
Minimum dimension of Septic tank manhole.* winkler titration method is used to determine
A. 20" x 20" dissolved oxygen levels using iodometric titration.
B. 24" x 24"
C. 14" x 14" Zero-gauge pressure is also known as atmospheric
D. 12" x 12" pressure and is _______.*
A. 29-inch mercury
The minimum wall thickness of any steel tank shall B. 16 psi
be No.____ U.S. gauge and each such tank shall be C. 18.5 psi
protected from corrosion, both externally and D. 14.7 psi
internally, by an approved bituminous coating or by
The standard atmosphere (symbol: atm) is
other acceptable means.* a unit of pressure defined as 101,325 Pa
A. 15 (1,013.25 hPa), which is equivalent to
B. 10 1,013.25 millibars, 760 mm Hg, 29.9212
C. 11 inches Hg, or 14.696 psi.
D. 12
The cheapest among sewer type pipes?*
The minimum wall thickness of a steel septic tank
A. Vitrified Clay Pipe
shall be number 12 U.S. gauge (0.109 of an inch)
B. Bituminous Fiber Sewer Pipe
(2.77 mm), and each such tank shall be protected
C. Screwed Pipe
from corrosion both externally and internally by an
D. Cast Iron Pipe
approved bituminous coating or by other
BITUMINOUS FIBER SEWER PIPE is the
acceptable means.
cheapest among the sewer pipes. It is
Pressure Vacuum Breaker Backflow Prevention sometimes recommended for house sewer
& for septic tank installation. This type of
Assembly (PVB)- consists of a loaded ____ inlet valve,
pipe is light in weight, slightly flexible w/c
an internally load check valve, two properly located could take slight soil movement w/o danger
test cocks and two isolation gate valves.* of cracking or pulling out from its joint.
A. water However, excessive hot water or chemical
B. air flow may soften or damage the pipe.
C. vacuum
D. liquid Minimum Frequency of Sampling for Drinking-Water
Supply Systems for Microbiological Examination for
A pressure vacuum breaker backflow prevention
assembly consists of a loaded air inlet valve, an level III(more than 100,000 population served).*
internally loaded check valve, two properly located A. 25 samples and additional one (1) sample
test cocks, and two isolation valves. This device per 10,000 population monthly
shall be permitted to be installed indoors where B. 10 samples and additional one (1) sample
provisions for spillage are provided. per 10,000 population monthly
C. 30 samples and additional one (1) sample
per 10,000 population monthly
Approved method of testing BOD for potable D. 20 samples and additional one (1) sample
per 10,000 population monthly
water.*
Level I 90 – 50Once in three months
A. Silver Diethyldithiocarbamate Method
(Colorimetric)
Level III Less than 5,000 One Minimum Frequency of Sampling for Drinking-Water
sample monthly
Supply Systems for Physical and Chemical Analysis
Level III 5,000 – 100,000 One
sample per 5,000 population monthly for Level II*
Level III More than 100,000 20 A. Every four months
samples and additional one (1) sample per B. Twice a year
10,000 population monthly C. Monthly
Emergency Supplies of Water D. Once a year
Before delivery to users PHYSICAL AND CHEMICAL ANALYSIS
Minimum number of Years Experience for None
Architects, CEME& SE* Plumbing shall be designed and adjusted to use the
A. 3
_______ quantity of water consistent with proper
B. 2
C. 4 performance and cleaning.*
D. 5 Level I
baccalaureate, pre-licensure experience of
two (2) years required of a graduate of
architecture prior to taking the licensure Level II
1/year
examination,
1-2
Approved method of testing TSS content for potable Level III
times/year
water.*
A. Gravametric Method
B. Dilution Technique Emergency
C. Colometric Method Supplies of
D. Silver Diethyldithiocarbamate Method Drinking Water
(Colorimetric)
Water Refilling
Gravimetric analysis is the most widely
Stations
used method for measuring total
suspended solids in water. It is a 2/year
quantitative technique that involves Water Vending
weighing the residues collected on glass- Machines
fiber or cellulose ester membrane filters
after filtration. A. maximum
B. minimum
WATER TASTE. In testing successive sections at least,
C. average
the upper 3 meters height of the preceding section D. satisfactory
previously tested shall be tested again so that no
Plumbing shall be designed and adjusted to use the
joint or pipe in the building (except the uppermost 3 minimum quantity of water consistent with proper
meter of the system) shall have been submitted to a performance and cleaning.
test of not less than ___ meters head of water. The Republic Act No. 1378
water shall be kept in the pile system or in the
portion under test, for at least _________ minutes Exception to 2% slope for Drainage line installation*
A. excessive depth of the proposed drainage
before inspection starts. The system shall be tight at
line
all joints.* B. structural and/or geological features of the
A. 3,17 terrain
B. 3,14 C. existing adverse in arrangements of
C. 3,16 building or structure any such pipe or
D. 3,15 piping l 02 mm or larger in diameter may
The water shall be kept in the system or in the have a slope of l 0 mm/m or 1% provided it
portion under test for at least 15 minutes before is first approved by the Administrative
inspection starts; the system shall then be tight at Authority.
all points. D. All of the Above
Horizontal Drainage pipes shall be run in Minimum Frequency of Sampling for Drinking-Water
practical and at a uniforms slope between
Supply Systems for Microbiological Examination for
manholes of nit less than 20mm/m or 2%
toward the point of the disposal, provided level III(less 5,000 population served).*
that, where it is impracticable to obtain a A. monthly
2% slope due to the following constraints: B. 6 mos.
excessive depth of the proposed drainage C. 2 mos.
line. D. 3 mos.
Microbiological Examination
Caulking Ferrule materials shall be of the best
quality* Level I 90 – 50 Once in three months
A. red cast brass
B. bronze Level II 600 Once in two months
C. copper
D. all of the above Level
Less than 5,000 One sample monthly
III
705.18 Caulking Ferrules
Caulking ferrules shall be of copper alloy and shall be Level
in accordance with Table 705.18. 5,000 – 100,000 One sample per 5,000 popula
III
TABLE 705.18
CAULKING FERRULE SPECIFICATIONS Level More than 20 samples and additional o
PIPE INSIDE MINIMUM III 100,000 monthly
LENGTH
SIZES DIAMETER WEIGHT
(inches)
(inches) (inches) EACH
Structural Design capacity of Septic tank cover as per
2 2 /4
1
4 /2
1
1 pound RPCP.*
A. 500 psi
1 pound 12
3 3 1 /4 41 /2 B. 400 psi
ounces
C. 600 psi
2 pounds 8 D. None of the Above
4 4 1 /4 41 /2 Structural Design capacity of Septic tank cover as
ounces
per RPCP is 500 psi
Where can asbestos pipe can be used?*
A. water line What is the lead limits(mg/L) in potable water
B. drainage line according to PNSDW of 2007?*
C. ventilation A. 0.03
D. downspout B. 0.01
E. all of the above C. 0.001
D. 0.02
Asbestos cement pipe was commonly used
to transport drinking water, wastewater, Changes in direction of drainage piping shall be
gases and fumes. Although highly resistant made by the use of approved pipe fittings and shall
to corrosion, it does eventually undergo
be of the angles presented by*
thinning, so replacement of existing
asbestos pipe systems is happening with
A. 22 l/2° bend
increasing frequency.
B. 45° bend
Minimum width of a septic tank as per RPCP.* C. 60° bend or other approved fittings of
A. 3 ft. longer sweeps.
B. 6 ft. D. All of the Above
C. 2 ft. 706.1 Approved Fittings
D. 4 ft. Changes in the direction of drainage piping shall be
Septic tank shall have minimum width of 750 mm, made by the appropriate use of approved fittings
minimum depth of one metre below water level and shall be of the angles presented by a one-
and a minimum liquid capacity of 1000 litres sixteenth bend, one-eighth bend, or one-sixth bend,
or other approved fittings of equivalent sweep.
In accordance to Table 4-1 of Revised Plumbing code Plastic pipe shall be supported at every one
(1) meter interval. alignment and prevent
how many patients in ward section of an hospital
sagging. exceeding 1.5 m length may be
can one water closet served.* supported at not more than 3 m interval.
A. 10 Supports shall be adequate and shall be
B. 8 placed within 0.45 m of the hub or joint.
C. 9
D. 7 Galvanized Steel pipe easily corroded by ________
and acid water.*
The minimum distance required between a Septic
A. rust
Tank and Water supply wells.* B. alkaline
A. 2.4m C. carbon
B. 3.7m D. moisture
C. 1.5m This type of pipe is easily corroded by
D. 15.2m alkaline and acid water. This is made out
E. 3m from mild steel, drawn through a die and
welded, cast into 6.00 meters long.
Regardless of the type of heater all energy source
must be turn off before attempting to _________.* Galvanized Steel pipe easily corroded by ______ and
A. do pressure check of the water system acid water.*
B. drain a water heater A. ice cold water
C. check the temperature of the water B. cold water
C. hot water
To attempt to _________ falsely or maliciously,
D. very hot water
directly or indirectly the professional reputation, At temperatures ranging from 390 F (200 C)
prospects or business of another Master Plumber.* to 480 F (250 C), the zinc-iron alloy layers
A. uplift will continue to protect the steel from
B. bolster corrosion. High temperatures above 480 F
C. defame (250 C) will accelerate peeling and
D. injure continued exposure can result in the zinc-
iron alloy layers cracking and separating
No water piping supplied by any _______ water from the steel.
supply system shall be interconnected to an
approved city water supply system or any other Where leaching beds are permitted in lieu of
source of supply without the approval of the trenches , the area of each such bed shall at least
Administrative Authority, Health Department, or ____% greater than the tubular requirements for
other agencies.* trenches.*
A. public A. 40
B. private B. 60
C. individual C. 30
D. group D. 50
Leaching Beds. Where leaching beds are
Which of the following are not part Cast Iron permitted in lieu of trenches, the area of
varieties?* each such bed shall be not less than fifty
A. Hubless Pipe (50) percent greater than the requirements
B. Single Hub Pipe for trenches.
C. Double Hub Pipe Composition of Asbestos Pipe*
D. None A. asbestos fiber and solvent cement
E. Standard Pipe B. cement and asbestos fiber
Plastic Pipe shall be supported at every C. asbestos fiber and solvent
D. solvent and cement
____________meter interval*
A. 1
B. 2
C. 3
D. 4
Each fixture directly connected to the drainage A. Colometric Method
B. Silver Diethyldithiocarbamate Method
system shall be equipped with a _______-sealed
(Colorimetric)
trap.* C. Atomic Absorption Spectrophometry
A. water D. Dilution Technique
B. air
C. gas Lead Pipe shall be supported at an interval not
D. vapor exceeding _______mts at the center with rigid
Construction documents presented with a permit Vertical back up.*
A. 4.2
application may be required to provide information
B. 1.2
on __________________________.* C. 2.2
A. The individual plumber who will install the D. 3.2
plumbing system
B. The direction of flow Lead use for For flashings or vent terminals- not less
C. The quantity of flow at a specific time of than ______ kg. per sq. meter and 1.2 mm thick.*
the day A. 15.0
B. 14.53
What is the benzene limits(mg/L) in potable water
C. 14.50
according to PNSDW of 2007?* D. 14.63
A. 0.01
B. 0.02 Horizontal support for Plastic Pipe shall be
C. 0.001 supported stiff metal or wood backing for plastic
D. 0.03
pipe ____ mm and smaller diameter.*
All shower receptors shall be tested for _______by A. 50
B. 25
filling with water to the level of the rough threshold.
C. 38
The test plug shall be so placed that both upper and D. 75
under sides of the sub-pan shall be subjected to the
test at the point where it is clamped to the drain.* Vertical Cast Iron Pipe shall be supported in every
A. water-tightness ______ or closer.*
B. air-tightness A. 1/2 storey
C. water and air-tightness B. storey
Shower receptors shall be tested for C. 2 storeys
watertightness by filling with water to the D. 3 storeys
level of the rough threshold. The test plug
shall be so placed that both upper and Copper tube shall not be used for piping carrying
under sides of the subpan shall be chemical or industrial.*
subjected to the test at the point where it is A. True
clamped to the drain. B. False
C. Maybe
408.7 Lining for Showers and Receptors -
UpCodes Material used in Galvanized Steel pipe.*
A. Medium Steel
B. Hard Steel
Construction documents presented with a permit C. Mild Steel
D. Medium Hard Steel
application may be required to provide information
on __________________________.* Date of first amendments of National Plumbing Code
A. The grade of the horizontal piping of the Philippines*
B. The elevations relevant to the proposed A. November 29, 1968
building B. November 29, 1967
C. both a and b C. November 28, 1968
D. none of the above D. November 28, 1967

Width of Color Code marking for copper tubing*


Approved method of testing lead content for potable A. 6.5mm
water.* B. 6.3mm
C. 6.6mm D. collector
D. 6.4mm
Most expensive type of pipe.*
Cast Iron pipe in horizontal position must be A. PVC
supported not more than ______ mts interval.* B. Galvanized Steel Pipe
A. 4 C. Copper
B. 3 D. Brass
C. 1.5
No building water service pipe shall be less than
D. 2.2
_____ in diameter.*
When the length of first compartment exceed A. Option 3
______ft. additional manhole must be provided over B. riser diagrams and plumbing plans
C. floor plans and riser diagrams
the wall of baffles.*
D. plumbing plans and electrical plans
A. 9
E. plumbing and cold water line
B. 12
C. 8 Minimum Frequency of Sampling for Drinking-Water
D. 10
Supply Systems for Microbiological Examination for
The following are author of Plumbing Engineering in Water refilling station*
Senate and Congress Except* A. 2 months
A. Karlo Nograles B. 6 months
B. Carlos Padilla C. Monthly
C. Chiz Ezcudero D. 3 months
D. Antonio Trillanes
Date of Signing of Plumbing Law of the Philippines*
If septic tank has over 6 cu mts capacity, the A. June 18, 1957
B. June 18, 1955
secondary compartment must at least ___ft.*
C. June 17, 1955
A. 7
D. June 18, 1956
B. 6
C. 3
D. 5
Composition of Asbestos Pipe*
Maximum number of hours sample of water be
A. asbestos fiber and solvent
process as per PNSDW of 2007.* B. solvent and cement
A. 12 hrs C. cement and asbestos fiber
B. 13 hrs D. asbestos fiber and solvent cement
C. 24 hrs
D. 36 hrs Minimum number of hours sample of water be
process as per PNSDW of 2007.*
What is the difference in invert elevation between
A. 5 hrs
inlet and out pipe of a Septic Tank?* B. 4 hrs
A. 2" C. 3 hrs
B. 1" D. 2 hrs
C. 3"
D. 5" The recovery rate of water heater is also referred to
E. 4" us:*
A. gim
Sampling time of potable water.*
B. gpd
A. 9am - 4pm
C. gph
B. 8am - 3pm
D. gpm
C. 1pm - 5pm
D. 10am - 5pm Type of Copper Pipe that can be use in water piping
A solar water heater panel is also known as a when installed above the ground or atop the
_______.* building or underground outside the structures with
A. circulator outside protective coating.*
B. pump collector A. Type O
C. roof heater B. Type M
C. Type L C. 4 liters
D. Type A D. 3 liters

What is the limit of the use of Cast iron Pipe?* Approved method of testing boron content for
A. 10 storeys potable water.*
B. 30 storeys A. Dilution Technique
C. 15 storeys B. Colometric Method
D. 25 storeys C. Atomic Absorption Spectrophometry
D. Silver Diethyldithiocarbamate Method
Construction documents presented with a permit
(Colorimetric)
application may be required to provide information
on __________________________.* Minimum depth of a septic tank as per Fajardo
A. The drainage fixture unit load on the book.*
system A. 4 ft.
B. The supply fixture unit load on the system B. 2 ft.
C. both a and b C. 6 ft.
D. none of the above D. 3 ft.

Minimum educational qualification for taking Master Minimum Frequency of Sampling for Drinking-Water
Plumber exam* Supply Systems for Microbiological Examination for
A. Is at least a high school graduate; level II (600 population served).*
B. Is at least a college graduate A. 2 mos.
B. 3 mods.
What is the cyanide limits(mg/L) in potable water
C. monthly
according to PNSDW of 2007?* D. 6 mos.
A. 0.001
B. 0.01 No excavation for a leach line or leach bed shall
C. 0.07 extend within ___m of the water table nor to a
D. 0.02
depth where sewage may contaminate the
Devices for heating and storing water shall be so underground water stratum that is usable for
designed and installed as to prevent dangers domestic purposes.*
from_______ through overheating.* A. 1.5
A. explosion B. 3
B. rupture C. 1
C. burst D. 2
D. implosion
Minimum capacity of digestive chamber of a septic
Unions - unions shall be installed in the water supply tank as per RPCP.*
piping within _____meter away from regulating A. 250 gallons
B. 750 gallons
equipment, water heater, conditioning tank and
C. 1000 gallons
similar equipment which require removal for D. 500 gallons
servicing or replacement.*
A. 0.5 Minimum Frequency of Sampling for Drinking-Water
B. 0.3 Supply Systems for Physical and Chemical Analysis
C. 0.4 for Level I*
D. 0.2 A. Monthly
B. Twice a year
The cheapest among sewer type pipes?*
C. Every four months
A. Bituminous Fiber Sewer Pipe
D. Once a year
B. Vitrified Clay Pipe
C. Screwed Pipe Direct connections between potable water piping
D. Cast Iron Pipe
and sewer-connected wastes shall not exist under
Volume of samples for Physical and Chemical any condition with or without backflow protection.
Analysis of drinking-Water supply system.* Where potable water is discharged to the drainage
A. 1 liter system, it shall be by means of an approved airgap of
B. 2 liters
two (2) pipe diameters from the supply outlet and The volume of sample should be sufficient
to carry out all tests required, preferably
the top surface of the drainage inlet, but in no case
not less than 100 ml.
shall the gap be less than ____ mm. Connection may
be made to the inlet side of a trap provided that an Galvanized Wrought Iron is more resistant to
approved atmospheric vacuum breaker is installed ____waste than the steel pipe.*
no less than ______mm above the flood level rim of A. chemical
B. acid
such trapped fixture, so that at no time will any such C. alkaline
device be subjected to any back pressure.* D. liquid
A. 36,152
B. 20,150 Basic principles listed in Revised Plumbing Code of
C. 25,152 1999 was based on what section of RA 1378?*
D. 30,151 A. Section 3
B. Section 2
Copper Tubing - shall be supported at each storey or C. Section 4
at maximum intervals of ____ meters on center.* D. Section 5
A. 5
B. 1 How many sets of construction documents must be
C. 2 provided during the application for a plumbing
D. 3 permit?*
E. 4 A. 4
Approved method of testing arsenic content for B. 1
C. 2
potable water.* D. 6
A. Dilution Technique
B. Silver Diethyldithiocarbamate Method Upon completion of a section or of the entire hot
(Colorimetric) and cold water supply systems, it shall be tested and
C. Colometric Method
D. Atomic Absorption Spectrophometry proved tight under a water pressure not less than
the working pressure under which it is to be used
Horizontal support for within Hub or joint of Cast plus ______%.*
iron pipe must be place at _____mts to maintain A. 40
alignment and sagging.* B. 60
A. 0.45 C. 30
B. 0.40 D. 50
C. 0.50
D. 0.55 Minimum Frequency of Sampling for Drinking-Water
Supply Systems for Microbiological Examination for
What is the mercury limits(mg/L) in potable water level I(90-150 population served).*
according to PNSDW of 2007?* A. monthly
A. 0.02 B. 6 mos.
B. 0.001 C. 3 mos.
C. 0.03 D. 2 mos.
D. 0.01
What type of Cast Iron Pipe generally used for
Brass is compose of __% zinc and ___% copper.* underground installation and considered extra duty
A. 16,84
pipe?*
B. 15,85
A. SV
C. 10,90
B. TV
D. 12,88
C. XV
Minimum volume of water sample for testing as per D. DV
PNSDW of 2007* Minimum Frequency of Sampling for Drinking-Water
A. 80ml
Supply Systems for Microbiological Examination for
B. 100ml
C. 200ml level III(more than 100,000 population served).*
D. 120ml A. 25 samples and additional one (1) sample
per 10,000 population monthly
B. 20 samples and additional one (1) sample Acid resistant Cast Iron Pipe is an alloy made of
per 10,000 population monthly
______ and cast iron.*
C. 10 samples and additional one (1) sample
A. tin
per 10,000 population monthly
B. aluminum
D. 30 samples and additional one (1) sample
C. pvc
per 10,000 population monthly
D. silicon
A site plan will normally show the location of
Mark color for Type DWV Copper tubing.*
__________.* A. blue
A. The number of plumbing fixtures installed B. green
B. Building ventilation openings C. red
C. The type of plumbing fixtures installed D. yellow
Minimum Frequency of Sampling for Drinking-Water Minimum Frequency of Sampling for Drinking-Water
Supply Systems for Physical and Chemical Analysis Supply Systems for Microbiological Examination for
for Water refilling station or vending machine.* Water vending machine.*
A. Once a year A. 6 months
B. Every four months B. 3 months
C. Monthly C. 2 months
D. Twice a year D. Monthly

Date of signing by Pres. Joseph Estrada of Revised


In what type of structure Asbestos Pipe best
Plumbing Code of 1999?*
suited?* A. December 22, 1999
A. Composite B. December 20, 1999
B. Wooden C. December 23, 1999
C. Concrete D. December 21, 1999
D. Steel

Minimum Frequency of Sampling for Drinking-Water FINAL PRE BOARD - PLUMBING CODE & PRACTICAL
Supply Systems for Microbiological Examination for PROBLEM 1 Engr. Olympio M. Lopez Jr., RMP, ME, CE
level III(5,000 – 100,000 population served).* & REB Cell No.: 0927-5720035 Landline: (02) 782-
A. 2 sample per 5,000 population bi-monthly 9086
B. 2 sample per 5,000 population monthly
C. 1 sample per 5,000 population bi-monthly 22. When the length of first compartment exceed
D. 1 sample per 5,000 population monthly ______ft. additional manhole must be provided over
the wall of baffles.
Horizontal support for hubless or compression a.9
gasket joints must be in every______.* b. 8
A. near joint c. 12
B. joint d. 10
C. end
D. middle 23. What is the difference in invert elevation between
inlet and out pipe of a Septic Tank?
What is the nickel limits(mg/L) in potable water a.1”
according to PNSDW of 2007?* b.2”
A. 0.07 c. 3”
B. 0.01 d. 4”
C. 0.02
D. 0.001 24.Structural Design capacity of Septic tank cover as
per RPCP.
Maximum depth of a septic tank as per RPCP.*
a. 500 psi
A. 3 ft.
b. 600 psi
B. 2 ft.
c. 400 psi
C. 4 ft.
d. None of the Above
D. 6 ft.
25. The minimum wall thickness of any steel tank
shall be No.____ U.S. gauge and each such tank shall
be protected from corrosion, both externally and c. Screwed Pipe
internally, by an approved bituminous coating or by d. Bituminous Fiber Sewer Pipe
other acceptable means.
a. 10 34. Material used in Galvanized Steel pipe.
b. 11 a.Medium Steel
c. 12 b. Hard Steel
d.15 c. Mild Steel
d. Hard Steel
26. What type of Cast Iron Pipe generally used for
underground installation and considered extra duty 35. Galvanized Steel pipe deteriorate faster when
pipe? used as__________supply line.
a.XV a.Cold Water
b.SV b. Hot Water
c. TV c. a & b.
d. None of the Above d. None of the Above

27. Which of the following not part Cast Iron varieties? 36. Galvanized Steel pipe easily corroded
a.Standard Pipe by___________and acid water.
b. Single Hub Pipe a.carbon
c. Double Hub Pipe b. iron
d. Hubless Pipe c. alkaline
e. None d. None of the Above

28. Limit of the used of Cast iron Pipe.


20 mm/m or 2%, of l0 mm/m or 1%
a.10 storeys
b. 15 storey 1. Horizontal drainage pipes shall be run in
c. 25 storeys practical alignments and at a uniform slope
d. 30 storeys between manholes of not less than ____
toward the point of disposal. For piping l02
29. Acid resistance Cast Iron is made of what metal? mm or larger in diameter may have a slope
a.tin ____ provided it is first approved by the
b. silicon Administrative Authority.
c.cast iron 22 l/2° bend, 45° bend, 60° bend
d. b & c 2. Changes in direction of drainage piping shall
be made by the use of approved pipe fittings
30. Composition of Asbestos Pipe. and shall be of the angles presented by a
a.Solvent cement ____, ____, ____ or other approved fittings
b. Cement of longer sweeps.
c.Asbestos Fiber 45°, 60° wye, combination wye, 1/8 bend
d. B & C branches
3. Horizontal drainage lines connecting to a
31. Where can asbestos pipe can be used? vertical stack shall enter through ____ or
a.Water line
____ branches, ____ and ____, sanitary tee
b. Drainage line
or other approved fittings of longer sweeps.
c. Ventilation
45° wye branches, combination wye, 1/8
d. downspout
bend
e. all of the above
4. Horizontal drainage lines connecting to other
32. In what type of structure Asbestos Pipe best suited? horizontal drainage lines shall enter
a.Steel through____ , ____ and ____ branches or
b. Wooden other approved fittings of longer sweeps.
c. Concrete 45-degree branches, Sixty (60) degree
d. Composite branches
5. Vertical drainage lines connecting to
33. The cheapest among sewer type pipes? horizontal drainage line shall enter
a.Cast Iron Pipe through____, or other approved fittings of
b. Vitrified Clay Pipe
longer sweep ____ or offsets may be used 14. Vertical Piping Screwed Pipe - Iron Pipe Size
only when installed in a true verticai position (IPS) shall be supported at not less than ____
drainage systems height
6. All plumbing fixtures, drains, appurtenances 3 meters
and appliances used to receive or discharge 15. Vertical Piping Copper Tubing - shall be
liquid wastes or sewage, shall be connected supported at each storey or at maximum
properly to the ____ of the building and intervals of ____ on center.
premises 1.20 meters
Private Sewage Disposal System 16. Vertical Piping Lead Pipe shall be supported
7. Every building where plumbing fixtures are at intervals not exceeding ____ at centers
installed shall have a sewer service with a rigid vertical back-up
connection to a public or private sewer 1 meter
systems. When a Public or Private Sewer is 17. Vertical Piping Plastic Pipe shall be supported
not available for use, excreta drainage piping at every ____ interval.
from buildings and premises shall be 1.5 meters, 3 meters, 0.45 meters
connected to an approved ____. 18. Horizontal Piping Cast Iron Soil Pipe- Where
rainwater drains joints occur, suspended cast iron soil pipe
8. It shall be unlawful for any person to deposit shall be supported at not more than ____
things which would or could cause damage to intervals; except that
the drainage system or public sewer. Areas pipe exceeding I.5 meters length, may be
having ____ shall discharge outside of the supported at not more than ____ intervals.
building or to the gutter, and shall not be Support shall be adequate to maintain
connected to the soil and waste pipe systems. alignment and to prevent sagging and shall
treatment be placed within ____ of the hub or joint.
9. Wastes detrimental to the public sewer each joint
system or to the functioning of the sewage 19. Hubless or compression gasket joints must be
treatment plant shall be treated and disposed supported at least at every other joint except
of as found necessary. Sewage or other waste that when the developed length between
from a plumbing system which may be supports exceeds 1.2 meters, they shall be
deleterious to surface or subsurface waters provided at ____
shall be subjected to some acceptable form 3.0 meters, 3.6 meters
of ____. 20. Horizontal Piping Screwed Pipe- IPS shall be
metal sleeve supported at approximately ____ intervals for
10. No pipe shall be directly embedded in piping 19 mm diameter and smaller and ____
concrete and masonry walls without ____ intervals for piping 25 mm and larger in
forty-five ( 45) degrees diameter.
11. The bottom of all pipe trenches deeper than 1.8 meters, 3.0 meters
the footing of any adjacent building or 21. Horizontal Piping Copper Tubing - shall be
structure and parallel to it must be at least supported at approximately ____ intervals for
____ therefrom. piping 38 mm diameter and smaller and ____
0.6 meter, 0.3 meter intervals for pipings 51 mm and larger in
12. No building sewer or other drainage pipings diameter.
or part thereof, constructed of materials entire length
other than that approved for use under or 22. Horizontal Piping Lead Pipe - shall be
within the building, shall be installed under or supported by stiff metal or wooden backing
within ____ of any building or structure, nor for its____ with hangers properly spaced.
less than ____ below the finish ground entire length
surface. 23. Horizontal In Ground piping buried in the
every storey ground shall be laid on a firm bed for its ____,
13. Vertical Piping Cast Iron Soil Pipe- Bell & except where concrete cradle support is
Spigot and Hubless pipe shall be supported at provided,
____ or closer. entire length
every other storey 24. Horizontal Piping Plastic Tube - shall be
supported by stiff metal or wood backing
with hangers in its ____ for small-size tubings
up to 38 mm diameter and without backings
but with spaced metal hangers at approved
spacing for larger-size tubings.
one-half (1/2)
25. Tunnels shall have a clear height of 0.6 meter
above the pipe and shall be limited in length
to ____ the depth of the trench, with a
maximum length of 2.4 meters. When pipe is
driven, the drive pipe shall be at least one
pipe size larger than the pipe to be laid.

0.3 meter
26. Trenches shall be backfilled in thin layers of
____ above the top of the pipe with clean
earth.

You might also like