Professional Documents
Culture Documents
Practice Exam - For Topic 6
Practice Exam - For Topic 6
What is the limit of the use of Cast iron Pipe?* Approved method of testing boron content for
A. 10 storeys potable water.*
B. 30 storeys A. Dilution Technique
C. 15 storeys B. Colometric Method
D. 25 storeys C. Atomic Absorption Spectrophometry
D. Silver Diethyldithiocarbamate Method
Construction documents presented with a permit
(Colorimetric)
application may be required to provide information
on __________________________.* Minimum depth of a septic tank as per Fajardo
A. The drainage fixture unit load on the book.*
system A. 4 ft.
B. The supply fixture unit load on the system B. 2 ft.
C. both a and b C. 6 ft.
D. none of the above D. 3 ft.
Minimum educational qualification for taking Master Minimum Frequency of Sampling for Drinking-Water
Plumber exam* Supply Systems for Microbiological Examination for
A. Is at least a high school graduate; level II (600 population served).*
B. Is at least a college graduate A. 2 mos.
B. 3 mods.
What is the cyanide limits(mg/L) in potable water
C. monthly
according to PNSDW of 2007?* D. 6 mos.
A. 0.001
B. 0.01 No excavation for a leach line or leach bed shall
C. 0.07 extend within ___m of the water table nor to a
D. 0.02
depth where sewage may contaminate the
Devices for heating and storing water shall be so underground water stratum that is usable for
designed and installed as to prevent dangers domestic purposes.*
from_______ through overheating.* A. 1.5
A. explosion B. 3
B. rupture C. 1
C. burst D. 2
D. implosion
Minimum capacity of digestive chamber of a septic
Unions - unions shall be installed in the water supply tank as per RPCP.*
piping within _____meter away from regulating A. 250 gallons
B. 750 gallons
equipment, water heater, conditioning tank and
C. 1000 gallons
similar equipment which require removal for D. 500 gallons
servicing or replacement.*
A. 0.5 Minimum Frequency of Sampling for Drinking-Water
B. 0.3 Supply Systems for Physical and Chemical Analysis
C. 0.4 for Level I*
D. 0.2 A. Monthly
B. Twice a year
The cheapest among sewer type pipes?*
C. Every four months
A. Bituminous Fiber Sewer Pipe
D. Once a year
B. Vitrified Clay Pipe
C. Screwed Pipe Direct connections between potable water piping
D. Cast Iron Pipe
and sewer-connected wastes shall not exist under
Volume of samples for Physical and Chemical any condition with or without backflow protection.
Analysis of drinking-Water supply system.* Where potable water is discharged to the drainage
A. 1 liter system, it shall be by means of an approved airgap of
B. 2 liters
two (2) pipe diameters from the supply outlet and The volume of sample should be sufficient
to carry out all tests required, preferably
the top surface of the drainage inlet, but in no case
not less than 100 ml.
shall the gap be less than ____ mm. Connection may
be made to the inlet side of a trap provided that an Galvanized Wrought Iron is more resistant to
approved atmospheric vacuum breaker is installed ____waste than the steel pipe.*
no less than ______mm above the flood level rim of A. chemical
B. acid
such trapped fixture, so that at no time will any such C. alkaline
device be subjected to any back pressure.* D. liquid
A. 36,152
B. 20,150 Basic principles listed in Revised Plumbing Code of
C. 25,152 1999 was based on what section of RA 1378?*
D. 30,151 A. Section 3
B. Section 2
Copper Tubing - shall be supported at each storey or C. Section 4
at maximum intervals of ____ meters on center.* D. Section 5
A. 5
B. 1 How many sets of construction documents must be
C. 2 provided during the application for a plumbing
D. 3 permit?*
E. 4 A. 4
Approved method of testing arsenic content for B. 1
C. 2
potable water.* D. 6
A. Dilution Technique
B. Silver Diethyldithiocarbamate Method Upon completion of a section or of the entire hot
(Colorimetric) and cold water supply systems, it shall be tested and
C. Colometric Method
D. Atomic Absorption Spectrophometry proved tight under a water pressure not less than
the working pressure under which it is to be used
Horizontal support for within Hub or joint of Cast plus ______%.*
iron pipe must be place at _____mts to maintain A. 40
alignment and sagging.* B. 60
A. 0.45 C. 30
B. 0.40 D. 50
C. 0.50
D. 0.55 Minimum Frequency of Sampling for Drinking-Water
Supply Systems for Microbiological Examination for
What is the mercury limits(mg/L) in potable water level I(90-150 population served).*
according to PNSDW of 2007?* A. monthly
A. 0.02 B. 6 mos.
B. 0.001 C. 3 mos.
C. 0.03 D. 2 mos.
D. 0.01
What type of Cast Iron Pipe generally used for
Brass is compose of __% zinc and ___% copper.* underground installation and considered extra duty
A. 16,84
pipe?*
B. 15,85
A. SV
C. 10,90
B. TV
D. 12,88
C. XV
Minimum volume of water sample for testing as per D. DV
PNSDW of 2007* Minimum Frequency of Sampling for Drinking-Water
A. 80ml
Supply Systems for Microbiological Examination for
B. 100ml
C. 200ml level III(more than 100,000 population served).*
D. 120ml A. 25 samples and additional one (1) sample
per 10,000 population monthly
B. 20 samples and additional one (1) sample Acid resistant Cast Iron Pipe is an alloy made of
per 10,000 population monthly
______ and cast iron.*
C. 10 samples and additional one (1) sample
A. tin
per 10,000 population monthly
B. aluminum
D. 30 samples and additional one (1) sample
C. pvc
per 10,000 population monthly
D. silicon
A site plan will normally show the location of
Mark color for Type DWV Copper tubing.*
__________.* A. blue
A. The number of plumbing fixtures installed B. green
B. Building ventilation openings C. red
C. The type of plumbing fixtures installed D. yellow
Minimum Frequency of Sampling for Drinking-Water Minimum Frequency of Sampling for Drinking-Water
Supply Systems for Physical and Chemical Analysis Supply Systems for Microbiological Examination for
for Water refilling station or vending machine.* Water vending machine.*
A. Once a year A. 6 months
B. Every four months B. 3 months
C. Monthly C. 2 months
D. Twice a year D. Monthly
Minimum Frequency of Sampling for Drinking-Water FINAL PRE BOARD - PLUMBING CODE & PRACTICAL
Supply Systems for Microbiological Examination for PROBLEM 1 Engr. Olympio M. Lopez Jr., RMP, ME, CE
level III(5,000 – 100,000 population served).* & REB Cell No.: 0927-5720035 Landline: (02) 782-
A. 2 sample per 5,000 population bi-monthly 9086
B. 2 sample per 5,000 population monthly
C. 1 sample per 5,000 population bi-monthly 22. When the length of first compartment exceed
D. 1 sample per 5,000 population monthly ______ft. additional manhole must be provided over
the wall of baffles.
Horizontal support for hubless or compression a.9
gasket joints must be in every______.* b. 8
A. near joint c. 12
B. joint d. 10
C. end
D. middle 23. What is the difference in invert elevation between
inlet and out pipe of a Septic Tank?
What is the nickel limits(mg/L) in potable water a.1”
according to PNSDW of 2007?* b.2”
A. 0.07 c. 3”
B. 0.01 d. 4”
C. 0.02
D. 0.001 24.Structural Design capacity of Septic tank cover as
per RPCP.
Maximum depth of a septic tank as per RPCP.*
a. 500 psi
A. 3 ft.
b. 600 psi
B. 2 ft.
c. 400 psi
C. 4 ft.
d. None of the Above
D. 6 ft.
25. The minimum wall thickness of any steel tank
shall be No.____ U.S. gauge and each such tank shall
be protected from corrosion, both externally and c. Screwed Pipe
internally, by an approved bituminous coating or by d. Bituminous Fiber Sewer Pipe
other acceptable means.
a. 10 34. Material used in Galvanized Steel pipe.
b. 11 a.Medium Steel
c. 12 b. Hard Steel
d.15 c. Mild Steel
d. Hard Steel
26. What type of Cast Iron Pipe generally used for
underground installation and considered extra duty 35. Galvanized Steel pipe deteriorate faster when
pipe? used as__________supply line.
a.XV a.Cold Water
b.SV b. Hot Water
c. TV c. a & b.
d. None of the Above d. None of the Above
27. Which of the following not part Cast Iron varieties? 36. Galvanized Steel pipe easily corroded
a.Standard Pipe by___________and acid water.
b. Single Hub Pipe a.carbon
c. Double Hub Pipe b. iron
d. Hubless Pipe c. alkaline
e. None d. None of the Above
0.3 meter
26. Trenches shall be backfilled in thin layers of
____ above the top of the pipe with clean
earth.