You are on page 1of 1

Pakistan Standards & Quality

Control Authority
Government Of Pakistan
(Ministry of Science & Technology)
Liaison Office Gujranwala

Website: www.psqca.com.pk

Ref No: SDC-CM (SLO-364)/21 Date:

M/S: STARCO ELECTRICAL INDUSTRIES, 184-C SMALL INDUSTRIAL ESTATE, G.T.


ROAD, GUJRAT
Brand: Starco

Unit Test Report of Domestic Gas Stove PS: 1560/2017 (R)

Sr. Tests Permissible Limits Results Remarks


No.
1 Frame of the body
(a) Steel Type M.S. Sheet
(b) Thickness of sheet used (mm) 0.8 min
(c) Tensile Strength (Kg/mm2) 28 min
2 Nipple & Pipe
(a) Material Type Mild Steel/Bars
(b) Height of Nipple (mm) 100
3 Tap (Knob)
(a) Material Type Bakelite
(b) Position Marked On/Off
4 Nuts & Screws Mild Steel Galvanized
Finish Visual Examination No Defect
Gas Valve (a) Brass
(a) Brass (b) 85 Min
(b) Hardness (HV)
5 Rigidity & Stability Rigid & Stable
6 Strength of Frame 20 Kg Max
7 Thermal Efficiency %
(a) Burner 1 50.0 min
(b) Burner 2 50.0 min
8 Marking
(a) Manufacturer Name or Trade Mark (a) Labeled
(b) Knobs “On” and “Off” (b) Labeled
(c) Country of Origin (c) Marked
(d) Gas Input Rating (d) Marked
(e) Thermal Efficiency (e) Marked
9 Packing Available

Signature of Unit Representative Signature of Inspecting Officer

PSQCA, Liaison office G-1 Garden Town, Gujranwala


Tell# 055-3835560