CASACADE DATA DHEET

CNG MOBILECASCADE (4500WL)

Sr
DESCRIPTION OFFERED
No.
1 Type of service CNG
2 Capacity (in water liter) 4500(-0%. +5%)
3 No. of Banks 3
4 Cascade Dimensions Refer GA Drawing
5 Cascade frame structure is be able to YES
withstand 4G (four times of gravity) test
from any direction without any
distortion
6 Frame weight 1940 kg
7 Total weight of casacde 9857 kg
6 No. of Cylinders in each bank
a. Low Pressure Bank 30 Nos
b. Medium Pressure Bank 18 Nos
c. High Pressure Bank 12 Nos
7 Cylinder
a. Cylinder Make EKC
b. Compliance Code IS 7285 (Part 2): 2015
c. Cylinder Size at 15°C (in water liter) 75 liters
d. Cylinder weight 113kg
e. Cylinder Operating Condition 255 bar(g) at 15°C
f. Cylinder testing parameters IS 7285 Part 2
g. Cylinder Material Seamless Alloy steel (Cr-Mo)/
PESO approved design
drawing
h. PESO approval YES
I Gas quantity stored in the cylinder at 965 kgs
15˚C @ 250 barg.
8 Cylinder Shut-off Valve
a. Make Tekno/Vanaz
b. Compliance Code IS 3224:2002
9 Combination Bursting Disc and Fusible
Plug
a. Burst Pressure in bar (g) 363-399 bar
b. Fuse Melting Temperature (in ºC) 125 +- 10 degree c
10. Interconnecting tube size (Mainline) Minimum ¾” OD
a. Tube Material SS-316L
b. Tube Make Sandvik/ Tubacex
c Tube fitting Swagelok
d Tube fitting/Valve Make Swagelok/Parker
e Material Swagelok/Parker
g Temperature gauge & Pressure gauge Wika /Baumer/ITEC
11. Pressure drop for each bank
a. Low Pressure Bank Calculation provided
b. Medium Pressure Bank
c. High Pressure Bank
12 Coefficient of Flow (Cv)-Cylinder valve 0.5
13 Coefficient of Flow (Cv)-Main 7.1
Isolation valve
14 End connection(Common Filling & Common QRC Coupler &
decanting) Nipple ½” & ¾ “ NPTF with
Rubber Protection cap
15 Notes.

1. All piping and flange shall be designed and meet the requirement as per ASME B31.3

GENERAL NOTES:
i. VENDOR TO PROVIDE THE DATA AS MARKED "#" IN DATA SHEET.
ii. ALL TUBING FITTINGS & OTHER PIPING COMPONENTS SHALL CONFORM TO RECOMMENDATIONS OF
ANSI B31.3.
iii. FLANGES AND GASKETS SHALL CONFORM TO ASME B16.5 & ASME B16.20 RESPECTIVELY.
iv. BIDDER TO PROVIDE FOUNDATION LOAD CALCULATIONS FOR MENTIONING ALLOWABLE
LOADS.
v. ALL GASKETS USED FOR HYDROSTATIC TESTING SHALL BE SAME AS SERVICE GASKETS.
vii. ALL TUBING FITTINGS & OTHER PIPING COMPONENTS SHALL CONFORM TO RECOMMENDATIONS OF
ANSI B31.3.
vii. ALL BUTT-WELDED JOINTS SHALL BE FULL PENETRATION WELD & ROOT RUN SHALL BE CARRIED OUT
BY TIG, IF ACCESSIBLE FROM OTHER SIDES SHALL BACK BE CHIPPED TO SOUND METAL & REWELD.
vii. FILLET WELDS SHALL BE EXAMINED BY MPI / DP METHOD.
viii. EARTHING LUG SHALL NOT BE GALVANISED OR PAINTED.
ix. VENTING SYSTEM OF EACH CYLINDER SHALL BE PROVIDED BY SUPPLIER.
x. ALL CYLINDER VENTING SYSTEM TUBING SHALL BE ONLY NUT FERRULE CONNECTIONS
ONLY.
xi. ALL FASTENERS SHALL BE ZINC COATED / HOT DIP GALVANISED AS PER ISO 10683 / ASTM A153&
STUD BOLT MATERIAL SHALL A193 Gr. B7 / Gr. 6.3 / 12.7