As the motor of this fan burned and replace it with repaired motor, high vibration was observed
as in table 1 where misalignment was observed also and after correct it the vibration it reduced
but still high in vertical side of motor and horizontal side in fan bearings as shown in table 2
where the balancing job was done and the results shown in Table 3.
The vibration in vertical side of motor still high and we do special test for shock absorber and
replace them under motor and the vibration become as shown in table 4
NDE DE DE NDE
H V A H V A H V A H V A
4627 FN-4 2.5 11.4 5.7 4.8 5.9 3.8 7.8 2.3 6.1 4.2 3.4 4.5
On 16.09.2023 Laser alignment checking was done and the result as following:
- And After Correct the alignment
Table2 :The Vibration Readings after correct misalignment
18.09.2023 MOTOR FAN
H V A H V A H V A H V A
4627 FN-4 2.6 6.8 3.8 5.3 8.7 3.7 7.5 4.3 7.4 9.2 4.3 4.7
• As vibration readings in bearings fan balancing was done where 40 grams added in 298 degree
the vibrations decrease in fan bearings without any improvements in motor bearings:
Table 3: The vibration readings after balancing:
18.09.2023 MOTOR FAN
H V A H V A H V A H V A
4627 FN-4 2.6 4.1 3.3 5.1 9.1 3.9 2.9 2.6 3.7 3.4 3.1 3.2
NDE DE DE NDE
H V A H V A H V A H V A
4627 FN-4 4.5 3.9 2.2 3.3 7.7 2.1 2.9 2.1 3.5 3.5 2.4 3.4
• After that shock absorber test was done and decided to replace them under motor :
• 6.2 • 3.8 • 3.7 • 2.2 • 2.1 • 3.2 • 5.4
4.7 3.6 3.3 2.9
• 4.06 • 5.6
NDE DE DE NDE
H V A H V A H V A H V A
4627 FN-4 2.6 3.9 3.6 3.9 7.5 2.1 3.8 3.3 4.1 3.4 2.7 3.9