You are on page 1of 11

[ATA] | [SUBCHAPTER] | [SECTION] [TITLE]

DELTA MAINTENANCE COURSE - 500 TO 600 - V4.3

ATA 36 PNEUMATIC SYSTEM

EN
0.0 (23/07/2014)

[REF] Copyright © 2011-2013 - ATR Training Centre - All right reserved For Training Only Page 1
ATA 36 PNEUMATIC SYSTEM | | Table of content

Table of Content

DELTA MAINTENANCE COURSE - 500 TO 600 - V4.3

ATA 36 PNEUMATIC SYSTEM ..................................................................................................................................................................................................................................... 3


36.00 GENERAL .................................................................................................................................................................................................................................................. 3
Presentation ................................................................................................................................................................................................................................................... 3
36.CI CONTROLS AND INDICATORS .................................................................................................................................................................................................................... 7
Multi Function Display ................................................................................................................................................................................................................................... 7
Maintenance Panel ...................................................................................................................................................................................................................................... 10

Copyright © 2011-2013 - ATR Training Centre - All right reserved For Training Only Page 2
ATA 36 PNEUMATIC SYSTEM | 36.00 GENERAL Presentation

The Pneumatic supplies Aircraft Systems which


ATA 36 PNEUMATIC SYSTEM use pressurized air.
These systems are:
36.00 GENERAL  Air Conditioning,
Presentation  Ventilation,
 Pressurization,
 De-icing.

MW36.00_.01.G1L1_01 Copyright © 2011-2013 - ATR Training Centre - All right reserved For Training Only Page 3
ATA 36 PNEUMATIC SYSTEM | 36.00 GENERAL Presentation

Compressed air is bled from the Engine


compressors at the LP or HP stages.

MW36.00_.01.G1L1_02 Copyright © 2011-2013 - ATR Training Centre - All right reserved For Training Only Page 4
ATA 36 PNEUMATIC SYSTEM | 36.00 GENERAL Presentation

Bleed air protection are:


 OVERHEAT, two Thermal Sensors are fitted
on pneumatic ducts, downstream of the Bleed
Air Shut-off Valve.
 OVERPRESSURE, a Pressure Sensor is
installed upstream of the Bleed Air Shut-off
Valve.
 AIR LEAK, Sensing Elements are fitted
beside the bleed air ducts.

MW36.00_.01.G1L1_03 Copyright © 2011-2013 - ATR Training Centre - All right reserved For Training Only Page 5
ATA 36 PNEUMATIC SYSTEM | 36.00 GENERAL Presentation

The LP and HP ducts join together to form a


single duct.
Pressure and Temperature Switches monitor the
bleed air, which flows through the Bleed Air
Shut-off Valve, which regulates air pressure.
Check Valves are fitted on the LP Ports. They
prevent reverse flow towards the LP
compressor, when hp pressure is used (HP
Bleed Valve opens at low power Engine range).
Both Bleed Air Shut-off Valves and HP Valve are
controlled by Engine bleed pushbutton on
Overhead Panel.
A Check Valve is fitted on the LH duct. It
prevents reverse flow to the left Engine bleed,
during Hotel Mode.
A Crossfeed Valve permits the interconnection of
sub-systems bleed ducts to supply both Air
Conditioning Packs. Opens only on ground.
De-icing System is supplied with bleed air from
the HP Port.
The surge margin and good steady state Engine
power characteristics are provided from LP Port
(through Handling Bleed Valve).

MW36.00_.01.G1L1_04 Copyright © 2011-2013 - ATR Training Centre - All right reserved For Training Only Page 6
ATA 36 PNEUMATIC SYSTEM | 36.CI CONTROLS AND INDICATORS Multi Function Display

Pneumatic System indications are given on AIR


BLEED Panel (located on the Overhead Panel)
and on SD Cabin page of the Multi Function
36.CI CONTROLS AND INDICATORS displays (located on the Instrument Panel).
Multi Function Display ENG 1 (2) BLEED air pushbutton controls both
Bleed Air Shut-Off and HP Bleed Valves.
Inhibited during engine start.
"ON" (pushbutton depressed without lighting)
normal operation, the Bleed Air Shut-Off Valve is
open.
State 1 is displayed on MFD.
Note: the HP Bleed Valve opens at low Engine
power.
"FAULT" amber light illuminates in case of Bleed
Air Shut-Off Valve position disagreement with
the relevant pushbutton.
State 2 is displayed on MFD.
These alarms illuminate in case of lack of bleed
air or electrical supply.
 Overpressure: Pressure above 80 PSI,
 Overheat: Temperature above 274°C,
 Leak: Temperature above 153°C and Fire
Handle pulled.
"OFF" white light illuminates with the pushbutton
released. HP Bleed Valve and Bleed Air Shut-Off
Valve are closed.
State 3 is displayed on MFD.

MW36.CI_.01.I1L2_01 Copyright © 2011-2013 - ATR Training Centre - All right reserved For Training Only Page 7
ATA 36 PNEUMATIC SYSTEM | 36.CI CONTROLS AND INDICATORS Multi Function Display

"OVHT" amber light illuminates when bleed duct


temperature exceeds 274°C (525 F).
State 1 is displayed on MFD.
Auto closure of Bleed Valves (Shut-Off and HP).
Associated Engine bleed pushbutton may be
reseted after cooling.
"LEAK" amber light illuminates when the Loop
temperature exceeds 153°C.
State 2 is displayed on MFD.
Auto closure of Bleed Valves (Shut-Off and HP)
after one second delay and Crossfeed Valve if
used on ground.

MW36.CI_.01.I1L2_02 Copyright © 2011-2013 - ATR Training Centre - All right reserved For Training Only Page 8
ATA 36 PNEUMATIC SYSTEM | 36.CI CONTROLS AND INDICATORS Multi Function Display

"X VALVE OPEN" amber light is extinguished


when the Crossfeed Valve is closed with both
Engines running or both Engines shut down.
Nothing is displayed on MFD.
"X VALVE OPEN" amber light is illuminated
when the Crossfeed Valve is open.
State 1 is displayed on MFD.
The valve is:
 Open on ground only.
 Inhibited in flight.
 Auto open when only one Engine is running
(Hotel Mode or Taxiing).
 Open with one Engine Bleed Air pushbutton
released and both Engines running.
"X VALVE OPEN" amber light is illuminated
when the Crossfeed Valve is stuck open with
both Engines running.
State 2 is displayed on MFD.
"X VALVE OPEN" amber light is illuminated
when the Crossfeed Valve is stuck open with
both Engines shut down.
State 3 is displayed on MFD.
"X VALVE OPEN" amber light is extinguished
when the Crossfeed Valve is stuck closed with
both Engines running.
State 4 is displayed on MFD.

MW36.CI_.01.I1L2_03 Copyright © 2011-2013 - ATR Training Centre - All right reserved For Training Only Page 9
ATA 36 PNEUMATIC SYSTEM | 36.CI CONTROLS AND INDICATORS Maintenance Panel

Pneumatic System recorded failure indication


and test are given on RH Maintenance Panel, for
maintenance purpose only.
MFC bite loaded indicator indicates that HP
Maintenance Panel Bleed Valve failures are recorded in the MFC
memory.
AIR BL LEAK PTT switch permits to check the
continuity of the Loops, the controller and the
associated warnings.

MW36.CI_.02.I1L2_01 Copyright © 2011-2013 - ATR Training Centre - All right reserved For Training Only Page 10
ATA 36 PNEUMATIC SYSTEM | 36.CI CONTROLS AND INDICATORS Maintenance Panel

Pneumatic System failure codes and Valves


positions can be read through the MCDU.
HP Bleed Valve failure codes can be read in
Miscellaneous 1 page of the MCDU.
HP Bleed Valve position can be read in Alpha
Call Up page of the MCDU.

MW36.CI_.02.I1L2_02 Copyright © 2011-2013 - ATR Training Centre - All right reserved For Training Only Page 11