Auto Dosing

Technical Setup
Guides LG Commercial Laundry Master Book
Auto-dosing Guide

Step 1. Interface
Connect corresponding wires for the pumps to washer.
Giant-C Pro
Wire Signal
CH Type Discharge Timing
Color Type
① Pre-Wash Red During Pre wash +
② Main Wash Blue Initial inlet during Main wash +
Last 5 minutes during Main wash
③ Bleach Yellow +
(If wash time is set under 7 min, after water inlet)
④ Softener Orange During Final rinse +
⑤ NA NA NA
⑧ - Black (Jump wire) -

Titan-C
Wire Signal
CH Type Discharge Timing
Color Type
ETC
① Red Initial inlet during Main wash +
(Emulsifier)
② Main Wash Blue Initial inlet during Main wash +
Last 5 minutes during Main wash
③ Bleach Yellow +
(If wash time is set under 7 min, after water inlet)
④ Softener Orange During Final rinse +
⑤ Pre-Wash Brown During Pre wash +
⑧ - Black (Jump wire) -

5 4 3 2 1
1 2 3 4 5 8

1
2
3
Giant-C Pro 4
5
1 Skip
4 8
2
3 1 2 3 4 5 8

Skip
Titan-C

Example) Harness connection


5 4 3 2 1

Table of Contents
Technical Guides LG Commercial Laundry Master Book
Auto-dosing Guide

Step 2. Setup on Washer


Second, set the time of injection on the machine.
Depending on your pump, you will need to check how much time equates
to how much detergent.

Giant-C Pro Titan-C

Table of Contents
Auto Dosing
Technical Setup
Guides LG Commercial Laundry Master Book
Auto-dosing Guide

Step 3. Relay Mode


Check that the correct pump operates in LQC2 mode.

Giant-C Pro Titan-C

Wire Color Wire Color


Black : Jump wire( - signal) Black : Jump wire( - signal)
Red : Pre-Wash (+ signal) Red : Emulsifier (+ signal)
Blue : Main Wash (+ signal) Blue : Main Wash (+ signal)
Yellow : Bleach (+ signal) Yellow : Bleach (+ signal)
Pump Pump Pump Pump
Orange : Softener (+ signal) Orange : Softener (+ signal)
1 2 3 4
Brown : Pre-Wash (+ signal)

+ - + - + - + -

Signal Pumping

Table of Contents
Technical Guides LG Commercial Laundry Master Book
Coin Box Installation

Install the coin box assembly as


below sequence.

Disassemble the drawer (dispenser), control panel assembly, and top plate assembly.

Assemble coin box to top plate and insert the holder to the hole of side frame (3ea).
Hook up the coin harness to holders carefully (prevent harness from touching the drum).

Connect harness to provided connectors.


Reassemble top plate assembly, control panel assembly, and drawer (dispenser).

Table of Contents
Technical Guides LG Commercial Laundry Master Book
Stacking Installation

Stacking kit is
provided in the
upper dryer.
(Loc No.A600
Silver: AGF30609833)

Before stacking, users need to secure enough space for the product,
Including height, and make sure the floor is evened out.

Install sliding brackets on lower machine (Take note of right/left brackets).

Secure brackets, then remove Control Panel and Top Plate.

Secure brackets on Top Plate and Front Frame, then reassemble Top Plate (Do not reassemble Control
Panel yet).

Next steps continued on following page Table of Contents


Technical Guides LG Commercial Laundry Master Book
Stacking Installation

Disassemble Control Panel for upper dryer, then assemble the coin selectors on the Panel.

Remove Lower Panel and install it on to Top Frame. Remove legs and its brackets.

Screw the sliding brackets on the base, then stack the machines. Fit the sliding brackets in the slots.

Secure the machines by installing back bracket. Secure bracket on Front Frame of upper dryer.

Assemble security lock to Front Frame with key. Connect coin selectors and display harness.

Next steps continued on following page Table of Contents


Technical Guides LG Commercial Laundry Master Book
Stacking Installation

Reassemble the Control Panels. Assemble security locks to both machines with key.

Convert to your needs!

Table of Contents
Technical Guides LG Commercial Laundry Master Book
Unstacking Guide
You may need to unstack machines to perform service on the lower machine.
Please follow the below guide to unstack the upper dryer.

1. Make sure you have enough room to 2. Unscrew 6 screws on the back bracket
work with the machines and unstack them.

3. Slide the machine so the 4 Sliding Pads line up with the 4 Stacking Bracket entrances on both sides.
The back of the upper dryer should line up with the Top Plate of the bottom machine.

4. Lift the upper dryer straight up with two people and put it down gently.
Perform necessary work, and stack the machines again in reverse order.
(or refer to stacking instructions section in previous pages)

Table of Contents
Technical Guides LG Commercial Laundry Master Book
Overall Installation Guide

Example of Installation

Note
For electrical outlet, use universal outlet and
put grounding wire for EACH machine.

Prepare gas fittings for the dryer.


3/8” X 3/8” Female (9.525 X 9.525mm)
1/2” X 3/8” Male (12.7 X 9.525mm)
3/8” Gas Hose ( 9.525mm)
Stainless Steel Hose Clamp

Typical Installation Details (Giant)


SQUARE DUCTING = 400mm X 400mm
EXHAUST PIPE = 4 Inch/101.6mm (metal)
ELECTRICAL = 4 Amps per machine
GAS PIPE LINE = ½ inch/12.7mm (Super G.I.)
※ Leave enough room behind dryer
WATER INLET = ½ or ¾ inch (PPR Pipe)
(700mm=27.6”) for good airflow 12.7or 19.05mm
Titan Dryer Exhaust Pipe: 6”/152.4mm DRAINAGE LINE = 4 inch/101.6mm main (PVC)
Titan Washer Drainage: 1.97”/50mm

Source: Big Wash


Note
Positioning and heights may vary depending on the existing
structure and/or provisions available within the location.

Height from floor finish level is in millimeters.


Table of Contents
Technical Guides LG Commercial Laundry Master Book
Dryer Duct Installation

Natural Multiple Venting System

Table of Contents
Technical Guides LG Commercial Laundry Master Book
Airflow Check

Check Dryer Airflow

Flame Check
1. Check for the blue color of fire for
good airflow and proper burning
2. Check that the flame is not wavering

Static Pressure
Giant dryer: 1.5 cm H₂O / 0.6 inH₂O

Manometer Note
Manometers could have ±0.3cm error
depending on the instrument.

Table of Contents
Technical Guides LG Commercial Laundry Master Book
Recommendations

“Do-Not” Recommendation List

1. Do not use wrinkled/ribbed exhaust pipes

2. Do not use exhaust ducts that are too long


3. Do not have exhaust pipes that are kinked
(too many bends or squished)
4. Do not use non-metallic exhaust pipes
5. Do not have reduced air flow due to clogged vent/lint filter
6. Do not neglect maintenance (lint filter, exhaust duct, etc.)

Table of Contents
Technical Guides LG Commercial Laundry Master Book
Dryer Power Cord Installation

Power Cord Installation (North America)

Remove the terminal access cover. Install UL-listed strain relief into power cord hole.

Giant Elec Dryer (4 wire)

Transfer dryer’s ground wire to center screw of terminal block.


Then attach the black & red wires as shown.
Attach power cord ground wire to (green) ground wire screw.

Giant Elec Dryer (3 wire)

Attach the black & red wires, and the neutral to the center screw of terminal as shown.
Attach power ground wire to (green) ground wire screw.

Close the access cover.


Table of Contents
Technical Guides LG Commercial Laundry Master Book
Dryer Power Cord Installation

Power Cord Installation (Europe, Asia, etc.)

Remove the terminal access cover. Install UL-listed strain relief into power cord hole.

Giant Elec Dryer (3 wire)

Remove the terminal access cover and attach the black & red wires as shown.
Attach power ground wire to (green) ground wire screw.

Close the access cover.

Table of Contents
Technical Guides LG Commercial Laundry Master Book
Clamping Guide

Improper Clamping may lead to machine damage

Maximum clamping force

Table of Contents
Technical Guides LG Commercial Laundry Master Book
Gravity Drain Guide

Take caution when installing Gravity Drain type Titan washer.


The height of drain pipe/hose should not be higher than the drain outlet.
Good example of Drain installation

※ Prevents back up smell from drainage.

Bad example of Drain installation

※ Drain point is higher than


washer’s drain outlet. This may
lead to Main PCB burnout with
SUdS error code.

Table of Contents
Technical Guides LG Commercial Laundry Master Book
Leg Stopper

Leg Stopper Installation


To reduce gap between legs and floor, use leg stoppers

Parts:

Non-skid Pads

Leg Stopper

Step 1. Place non-skid pads under where legs will be, then place leg stoppers

Step 2. Perform diagonal test to balance machine


- Put weight in drum and run spin
- Rock machine diagonally to check shaking
- If machine shakes, adjust leg height using wrench

Check for shaking