Sample Temp Temp Temp Temp Hot Water Hot Water Cold Water Cold Water Flow
Number T1 T2 T3 T4 Pump Flowrate Valve Flowrate Orientation
Setting Fhot Setting Fcold
[°C] [°C] [°C] [°C] [%] [l/min] [%] [l/min]
1 34.7 30.0 16.2 25.3 43 3.0 17 1.61 Countercurrent
2 34.9 30.1 16.1 25.4 43 2.9 17 1.54 Countercurrent
3 34.9 30.5 15.9 26.2 43 3.1 17 1.31 Countercurrent
4 35.2 31.0 15.9 26.8 43 2.9 17 1.14 Countercurrent
5 35.3 30.9 15.8 26.8 43 3.1 17 1.20 Countercurrent
6 35.7 31.1 15.7 26.8 43 3.0 17 1.38 Countercurrent
7 35.8 31.1 15.7 26.6 43 3.0 17 1.26 Countercurrent
8 36.0 31.3 15.6 26.8 43 3.0 17 1.25 Countercurrent
9 36.1 31.3 15.6 26.8 43 3.1 17 1.25 Countercurrent
10 36.1 31.2 15.6 26.6 43 2.9 17 1.28 Countercurrent
11 36.4 33.0 15.6 30.0 43 3.1 17 0.82 Countercurrent
12 36.9 32.0 15.6 27.8 43 3.1 17 1.35 Countercurrent
13 37.1 31.5 15.6 26.3 43 3.0 17 1.57 Countercurrent
14 37.0 31.5 15.6 26.3 43 2.9 17 1.57 Countercurrent
15 36.9 31.5 15.6 26.4 43 2.9 17 1.55 Countercurrent
16 36.9 31.6 15.6 26.5 43 3.1 17 1.62 Countercurrent
17 36.8 31.4 15.7 26.2 43 3.0 17 1.67 Countercurrent
18 37.0 31.2 15.7 25.7 43 3.1 17 1.71 Countercurrent
19 36.9 31.2 15.7 25.7 43 3.0 17 1.75 Countercurrent
20 36.6 32.4 15.8 28.9 43 3.0 17 1.26 Countercurrent
21 36.9 31.5 15.8 26.2 43 3.1 17 1.54 Countercurrent
22 37.0 31.4 15.8 26.1 43 2.9 17 1.70 Countercurrent
23 36.9 31.6 15.9 26.6 43 3.0 17 1.45 Countercurrent
24 37.0 32.1 15.9 28.0 43 3.1 17 1.62 Countercurrent
25 37.1 31.6 15.9 26.4 43 3.0 17 1.60 Countercurrent
26 37.3 32.8 16.0 27.5 43 3.0 17 0.57 Countercurrent
27 37.3 32.1 16.0 27.6 43 3.0 17 1.77 Countercurrent
28 37.3 31.7 16.0 26.3 43 3.0 17 1.73 Countercurrent
29 37.3 31.6 16.0 26.3 43 3.0 17 1.71 Countercurrent
30 37.2 31.6 16.1 26.2 43 3.0 17 1.67 Countercurrent
31 37.2 31.6 16.1 26.3 43 3.0 17 1.71 Countercurrent
Page 1
HT32 Plate Heat Exchanger - Run 1 Results
Page 2
HT32 Plate Heat Exchanger - Run 1 Results
Specific Heat Specific Heat Hot Fluid Density Cold Fluid Density Thot
Hot Fluid Cold Fluid Average Hot Fluid Average Cold Fluid
Notes
Cph Cpc Temperature Temperature
[kJ/kg K] [kJ/kg K] [%] [kg/m³] [%] [kg/m³] [°C]
4.178 4.181 32.357055664 994.9 20.765014648 998.1 4.8
4.178 4.181 32.486938477 994.9 20.732543945 998.1 4.8
4.178 4.181 32.714233398 994.8 21.057250977 998.0 4.4
4.178 4.181 33.087646484 994.7 21.349487305 997.9 4.2
4.178 4.181 33.120117188 994.7 21.284545898 997.9 4.4
4.178 4.181 33.396118164 994.6 21.252075195 997.9 4.6
4.178 4.181 33.46105957 994.6 21.154663086 998.0 4.7
4.178 4.181 33.672119141 994.5 21.219604492 998.0 4.7
4.178 4.181 33.720825195 994.5 21.187133789 998.0 4.8
4.178 4.181 33.688354492 994.5 21.105957031 998.0 4.9
4.178 4.180 34.678710938 994.1 22.794433594 997.6 3.4
4.178 4.181 34.451416016 994.2 21.690429688 997.8 4.8
4.178 4.181 34.2890625 994.3 20.927368164 998.0 5.6
4.178 4.181 34.224121094 994.3 20.927368164 998.0 5.5
4.178 4.181 34.207885742 994.3 20.99230957 998.0 5.4
4.178 4.181 34.224121094 994.3 21.057250977 998.0 5.3
4.178 4.181 34.094238281 994.3 20.927368164 998.0 5.5
4.178 4.181 34.07800293 994.3 20.732543945 998.1 5.7
4.178 4.181 34.013061523 994.4 20.748779297 998.1 5.7
4.178 4.180 34.50012207 994.2 22.33984375 997.7 4.3
4.178 4.181 34.191650391 994.3 21.024780273 998.0 5.5
4.178 4.181 34.191650391 994.3 20.959838867 998.0 5.6
4.178 4.181 34.240356445 994.3 21.235839844 998.0 5.3
4.178 4.181 34.532592773 994.2 21.950195313 997.8 4.8
4.178 4.181 34.354003906 994.3 21.170898438 998.0 5.5
4.178 4.181 35.01965332 994.0 21.722900391 997.8 4.5
4.178 4.181 34.743652344 994.1 21.8203125 997.8 5.2
4.178 4.181 34.50012207 994.2 21.138427734 998.0 5.7
4.178 4.181 34.451416016 994.2 21.154663086 998.0 5.6
4.178 4.181 34.370239258 994.2 21.154663086 998.0 5.6
4.178 4.181 34.435180664 994.2 21.203369141 998.0 5.6
Page 3
HT32 Plate Heat Exchanger - Run 1 Results
Page 4
HT32 Plate Heat Exchanger - Run 1 Results
Tcold Hot Mass Cold Mass Heat Power Heat Power Heat Power Overall Temp Temp Mean
Flow Rate Flow Rate emitted absorbed lost Efficiency Efficiency Efficiency Temp
qmh qmc Qe Qa Qf for hot fluid for cold fluid Efficiency
[°C] [kg/s] [kg/s] [W] [W] [W] [%] [%] [%] [%]
9.1 0.050 0.027 1005.13 1022.53 -17.40 101.7 25.7 49.2 37.5
9.3 0.048 0.026 961.48 996.91 -35.43 103.7 25.7 49.5 37.6
10.2 0.051 0.022 926.67 929.07 -2.40 100.3 23.1 53.9 38.5
10.9 0.048 0.019 842.27 863.82 -21.55 102.6 21.8 56.6 39.2
10.9 0.051 0.020 948.34 910.28 38.06 96.0 22.6 56.1 39.4
11.0 0.050 0.023 956.02 1055.85 -99.83 110.4 23.0 55.2 39.1
10.9 0.050 0.021 975.16 956.77 18.39 98.1 23.4 54.4 38.9
11.2 0.050 0.021 976.27 969.95 6.32 99.4 22.9 54.9 38.9
11.1 0.051 0.021 1022.42 964.34 58.09 94.3 23.6 54.3 38.9
11.0 0.049 0.021 998.86 984.04 14.81 98.5 23.9 53.7 38.8
14.4 0.051 0.014 713.40 815.82 -102.42 114.4 16.3 69.2 42.7
12.1 0.051 0.023 1015.31 1144.07 -128.77 112.7 22.6 57.2 39.9
10.7 0.050 0.026 1175.30 1169.93 5.37 99.5 26.0 49.7 37.8
10.7 0.048 0.026 1115.00 1169.93 -54.92 104.9 25.8 49.9 37.9
10.8 0.048 0.026 1090.75 1165.77 -75.02 106.9 25.4 50.7 38.1
10.9 0.051 0.027 1125.16 1228.15 -102.99 109.2 25.0 51.1 38.1
10.6 0.050 0.028 1134.21 1227.37 -93.17 108.2 25.8 49.8 37.8
10.0 0.052 0.028 1253.27 1192.58 60.68 95.2 27.1 47.2 37.2
10.0 0.050 0.029 1181.50 1214.19 -32.69 102.8 26.9 47.4 37.2
13.1 0.050 0.021 887.88 1140.85 -252.96 128.5 20.4 62.7 41.6
10.4 0.051 0.026 1152.61 1114.89 37.72 96.7 25.8 49.4 37.6
10.2 0.048 0.028 1128.13 1206.96 -78.83 107.0 26.4 48.4 37.4
10.7 0.050 0.024 1104.87 1082.40 22.47 98.0 25.2 51.0 38.1
12.1 0.051 0.027 1022.14 1363.38 -341.24 133.4 23.0 57.4 40.2
10.5 0.049 0.027 1138.28 1162.69 -24.41 102.1 26.1 49.4 37.7
11.5 0.050 0.010 941.94 458.52 483.42 48.7 21.2 54.0 37.6
11.6 0.050 0.029 1084.35 1430.51 -346.16 131.9 24.4 54.5 39.4
10.3 0.050 0.029 1176.50 1236.85 -60.35 105.1 26.6 48.1 37.4
10.2 0.050 0.028 1179.35 1215.56 -36.22 103.1 26.6 48.2 37.4
10.2 0.050 0.028 1172.60 1181.96 -9.36 100.8 26.6 48.2 37.4
10.2 0.050 0.028 1177.32 1211.68 -34.36 102.9 26.6 48.2 37.4
Page 5
HT32 Plate Heat Exchanger - Run 1 Results
13.6 0.050 0.021 853.59 1191.69 -338.10 139.6 19.5 64.4 41.9
10.2 0.052 0.027 1224.49 1168.40 56.10 95.4 26.7 47.9 37.3
10.3 0.049 0.028 1153.53 1219.37 -65.84 105.7 26.5 48.3 37.4
14.2 0.050 0.012 645.09 698.13 -53.04 108.2 14.7 66.7 40.7
14.2 0.050 0.020 846.90 1206.41 -359.51 142.5 18.9 66.4 42.7
10.5 0.052 0.029 1252.27 1255.21 -2.94 100.2 26.7 48.2 37.5
15.1 0.050 0.015 725.62 945.59 -219.97 130.3 16.1 69.2 42.6
10.7 0.048 0.028 1193.23 1268.00 -74.77 106.3 26.7 48.5 37.6
10.8 0.047 0.029 1155.41 1321.55 -166.13 114.4 26.4 48.8 37.6
10.8 0.049 0.029 1214.80 1299.27 -84.48 107.0 26.7 48.4 37.5
10.7 0.052 0.028 1281.03 1238.45 42.58 96.7 26.6 48.2 37.4
13.7 0.051 0.014 787.79 800.18 -12.38 101.6 16.8 62.2 39.5
10.8 0.050 0.028 1238.13 1248.10 -9.97 100.8 26.6 48.8 37.7
14.4 0.048 0.012 708.29 730.43 -22.14 103.1 15.8 64.2 40.0
12.2 0.050 0.015 1058.41 789.43 268.98 74.6 22.3 54.3 38.3
16.4 0.049 0.014 769.54 987.19 -217.66 128.3 16.4 71.3 43.9
12.1 0.051 0.026 1257.57 1301.73 -44.16 103.5 25.2 51.6 38.4
11.3 0.049 0.030 1274.13 1409.70 -135.57 110.6 26.7 48.5 37.6
12.5 0.049 0.025 1147.94 1311.90 -163.97 114.3 24.1 53.5 38.8
11.6 0.049 0.028 1271.25 1353.77 -82.52 106.5 26.4 49.4 37.9
11.4 0.050 0.024 1047.21 1129.23 -82.02 107.8 23.7 53.8 38.7
Page 6
HT32 Plate Heat Exchanger - Run 1 Results
Page 7
HT32 Plate Heat Exchanger - Run 1 Results
11.6 1928.190
13.2 2441.013
13.2 2306.610
11.8 1443.711
11.6 1928.812
13.5 2446.469
11.6 1652.839
13.7 2296.396
13.7 2219.561
13.8 2321.197
13.7 2464.685
12.6 1639.011
13.7 2383.494
12.7 1471.521
13.6 2051.020
11.8 1715.969
14.2 2331.498
14.4 2328.671
14.0 2158.942
14.3 2331.933
12.7 -2162.072
2160.5
Page 8