Professional Documents
Culture Documents
Maquina Menu Isytech
Maquina Menu Isytech
There are several menus available to setup up the unit to the best performances.
Buttons sequence
Menu Parameters Machine status Door Code
Press together
34
MENU 12
T 31,10 T 31,11 T31,11,2 t31,10,2 T31,10 T 31,11 T31,11,2 t31,10,2 t31,11,2 T31,21 T31,21 t31,11,2
model T101CW T111cw T202 CW t102 cw t101 T111 T202 hw t102 HW T112 cw T201 cw T201 T112 hw
ct120 ct160 a270abt HW H.W a270abt ct270 a200 hw ct270
ct120 ct160 a200
Param. Desc. range unit
dn detergent
pump off/on
‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐
Rinse pump
rn manual
activation
Door must
be closed On/off
dt dosage time
detergent off 0‐25 sec
5 5 5 5 5 5 5 5 5 5 5 5
35
bl dosage time
rinse aid off 0‐25 sec
3 3 3 3 3 3 3 3 3 3 3 3
MENU 35
T 31,10 T 31,11 T31,11,2 t31,10,2 T31,10 T 31,11 T31,11,2 t31,10,2 t31,11,2 T31,21 T31,21 t31,11,2
model T101CW T111cw T202 CW t102 cw t101 T111 T202 hw t102 HW T112 cw T201 cw T201 T112 hw
ct120 ct160 a270abt HW H.W a270abt ct270 a200 hw ct270
ct120 ct160 a200
Param. Desc. range unit
Air gap Break tank Press AP yes yes yes yes yes yes yes yes yes yes yes yes
ca pressostat
calibration
must be
empty
for 5
seconds
Fi First filling
function off/on
on on on on on on on on on on on on
cs Software code
201 202 203 204 205 206 207 208 210 211 212 214
esp Additional pc
board Off/on off off off off off off off off off off off off
36
MENU 42
T 31,10 T 31,11 T31,11,2 t31,10,2 T31,10 T 31,11 T31,11,2 t31,10,2 t31,11,2 T31,21 T31,21 t31,11,2
model T101CW T111cw T202 CW t102 cw t101 T111 T202 hw t102 HW T112 cw T201 cw T201 T112 hw
ct120 ct160 a270abt HW H.W a270abt ct270 a200 hw ct270
ct120 ct160 a200
Param. Desc. range unit
P1 program 1 High
Capacity off/on
on on on on on on on on on on on on
P2 General
Purpose off/on
off on on off off off on Off on on on on
ap1 prolonged
contact off/on
on on on on on on on on on on on on
All boiler
ec elements
heating off/on
off off off off off off off off off off off off
taut autotimer
washing 5‐360 sec
110 110 130 130 110 110 130 130 110 130 130 110
37
trr Rinse delay
time 2‐180 sec
4 4 4 4 4 4 4 4 4 4 4 4
MENU 42
T 31,10 T 31,11 T31,11,2 t31,10,2 T31,10 T 31,11 T31,11,2 t31,10,2 t31,11,2 T31,21 T31,21 t31,11,2
model T101CW T111cw T202 CW t102 cw t101 T111 T202 hw t102 HW T112 cw T201 cw T201 T112 hw
ct120 ct160 a270abt HW H.W a270abt ct270 a200 hw ct270
ct120 ct160 a200
Param. Desc. range unit
tdd
Double rinse
tank drain time 120 120 120 120 120 120 120 120 120 120 120 120
out off 2‐180 sec
bt break tank
on/off on‐off
off on on off off on on Off on on on on
Lbas
alarm's no
water break 20 20 20 20 20 20 20 20 20 20 20 20
tank 0‐250 mm
Lbar
stop alarm no
water break 80 80 80 80 80 80 80 80 80 80 80 80
tank 0‐250 mm
38
ib Hysteresis
boiler 2‐8 C°
2 2 2 2 2 2 2 2 2 2 2 2
MENU 42
T 31,10 T 31,11 T31,11,2 t31,10,2 T31,10 T 31,11 T31,11,2 t31,10,2 t31,11,2 T31,21 T31,21 t31,11,2
model T101CW T111cw T202 CW t102 cw t101 T111 T202 hw t102 HW T112 cw T201 cw T201 T112 hw
ct120 ct160 a270abt HW H.W a270abt ct270 a200 hw ct270
ct120 ct160 a200
Param. Desc. range unit
it Wash tank
Hysteresis 2‐8 C°
2 2 2 2 2 2 2 2 2 2 2 2
nt Boiler NTC
compensation off 0‐10 C°
3 2 2 2 2 2 2 2 3 3 2 3
df Factory setting
reset
no no no no no no no no no no no no
39
MENU 54 - SP1 HIGH CAPACITY
T 31,10 T 31,11 T31,11,2 t31,10,2 T31,10 T 31,11 T31,11,2 t31,10,2 t31,11,2 T31,21 T31,21 t31,11,2
model T101CW T111cw T202 CW t102 cw t101 T111 T202 hw t102 HW T112 cw T201 cw T201 T112 hw
ct120 ct160 a270abt HW H.W a270abt ct270 a200 hw ct270
ct120 ct160 a200
Param. Desc. range unit
Intermittant
Int1 speed 0= on‐16 sec off off off off off off off off off off off off
Conveyor stop
tof1 temperature 50‐70 C°
60 60 60 60 60 60 60 60 60 60 60 60
Conveyor start
ton1 temperature 70‐90 C°
78 78 78 78 78 78 78 78 78 78 78 78
Element
E11 boiler 1 off/on
on on on on on on on on on on on on
Element
E12 boiler 2 off/on
on on on on off off on on on on on on
Element
E13 boiler 3 off/on
on on on on off off off off on on off off
Rinse
tar1 autotimer time off/100 sec
off off 30 off off off 30 off off 30 30 off
40
MENU 54 - SP2 GENERAL PURPOSE
T 31,10 T 31,11 T31,11,2 t31,10,2 T31,10 T 31,11 T31,11,2 t31,10,2 t31,11,2 T31,21 T31,21 t31,11,2
model T101CW T111cw T202 CW t102 cw t101 T111 T202 hw t102 HW T112 cw T201 cw T201 T112 hw
ct120 ct160 a270abt HW H.W a270abt ct270 a200 hw ct270
ct120 ct160 a200
Param. Desc. range unit
Intermittant
Int2 speed 0= on‐16 sec off off off off off off off off off off off off
Conveyor stop
tof2 temperature 50‐70 C°
60 60 60 60 60 60 60 60 60 60 60 60
Conveyor start
ton2 temperature 70‐90 C°
78 78 78 78 78 78 78 78 78 78 78 78
Element
E21 boiler 1 off/on
on on on on on on on on on on on on
Element
E22 boiler 2 off/on
on on on on off off on on on on on on
Element
E23 boiler 3 off/on
on on on on off off off off on on on off
Rinse
tar2 autotimer time off/100 sec
off off 30 off off off 30 off off off 30 off
41
MENU 54 - AP1 PROLONGED CONTACT
T 31,10 T 31,11 T31,11,2 t31,10,2 T31,10 T 31,11 T31,11,2 t31,10,2 t31,11,2 T31,21 T31,21 t31,11,2
model T101CW T111cw T202 CW t102 cw t101 T111 T202 hw t102 HW T112 cw T201 cw T201 T112 hw
ct120 ct160 a270abt HW H.W a270abt ct270 a200 hw ct270
ct120 ct160 a200
Param. Desc. range unit
Intermittant
Int3 speed 0= on‐16 sec 7 7 8 8 7 7 8 8 7 7 8 7
Conveyor stop
tof3 temperature 50‐70 C°
60 60 60 60 60 60 60 60 60 60 60 60
Conveyor start
ton3 temperature 70‐90 C°
78 78 78 78 78 78 78 78 78 78 78 78
Element
E31 boiler 1 off/on
on on on on on on on on on on on on
Element
E32 boiler 2 off/on
on on on on off off on off on on off on
Element
E33 boiler 3 off/on
off off off off off off off off on on off off
Rinse
tar3 autotimer time off/100 sec
off off 60 off off off 60 off off 60 60 off
42
MENU 54 - AP2 GLASSES
T 31,10 T 31,11 T31,11,2 t31,10,2 T31,10 T 31,11 T31,11,2 t31,10,2 t31,11,2 T31,21 T31,21 t31,11,2
model T101CW T111cw T202 CW t102 cw t101 T111 T202 hw t102 HW T112 cw T201 cw T201 T112 hw
ct120 ct160 a270abt HW H.W a270abt ct270 a200 hw ct270
ct120 ct160 a200
Param. Desc. range unit
pl4 prewash off/on off off off off off off off off on off off on
Intermittant
Int4 speed 0= on‐16 sec off off 8 8 off off 8 8 off off 8 off
Conveyor stop
tof4 temperature 50‐70 C°
60 60 60 60 60 60 60 60 60 60 60 60
Conveyor start
ton4 temperature 70‐90 C°
78 78 78 78 78 78 78 78 78 78 78 78
Element
E41 boiler 1 off/on
on on on on off on on on on on on on
Element
E42 boiler 2 off/on
on on on on on off on off on on off on
Element
E43 boiler 3 off/on
off off off off off off off off on on off off
Rinse
tar4 autotimer time off/100 sec
off off 60 off off off 60 off off 60 60 off
43
44
45
46
47
48
Line contactor . When machine is
on it is activated . Must be on
50
Fuse protection 4 A T Output
51
Fuse protection 4 A T power supply pc
board. When open display is OFF
Er51
+
ErSf