No of T/R Tank Diameter Tank Area Current DemanCurrent Demand (with 1.25 current losses) T/output Resistance
m m2 A A A Ω
1 72 4,071.5 48.9 61.1 76.3407 0.34977025
2 72 4,071.5 48.9 61.1 76.3407 0.34977025
3 72 4,071.5 48.9 61.1 76.3407 0.34977025
4 72 4,071.5 48.9 61.1 76.3407 0.34977025
0.59102025

Titanium conductor Bar width 12.7 mm


thickness 0.9 mm
coil length 76.22 m

MMO ribbon anodes width 12.7 mm


thickness 0.635 mm
current output 0.034A/m

56.8181818
Cable resistance T/R voltage mmo ribbon Length Conductore bar
Ω V m m
0.24125 45.11890068 1078.41921138655 #REF!
0.24125 45.11890068 1078.41921138655 #REF!
0.24125 45.11890068 1078.41921138655 #REF!
0.24125 45.11890068 1078.41921138655 #REF!
total length total length
4313.67684554621 #REF!

36.6662531871428

880
40

770
101.6 245.098612361519
15.655625581928

0
0
n= 9 Yi 32.0 24.0
3.57428129931197 Li 33.0 53.7
Length of Ribbons 514.696507100923 (m)
Diameter of tank 72 (m)

Minimum length of Ribbons 9 (m)


Anode Output 7 (A/m)
Current Required for protection 61.0725611857856 (A)

n= 9
Space between Anodes 8.00 (m)
Resistance of Anodes 0.039196906512217
ρ (Soil resistivity) 50 (Ω.m)
W (Width of anode) 0.0127 (m)
0.5 (m)

width (mm) 12.7 mm


TI conductor Bar thickness mm 0.9 mm
current output A/m 11.4 A
16 8 0 -8 -16 -24 -32
64.49806 70.19972 72 70.19972 64.49806 53.66563 32.98485
Anode Output 0.034 A/m

n= 19 yi 34 30 27 23 19 15 11 8 4
7.489022301296 Li 23 39 49 56 61 65 68 70 72
Length of Ribbons 1078.419211387 (m)
Diameter of tank 72 (m)

Minimum length of Ribbons 1071.448441856 (m)


Anode Output 0.057 (A/m)
Current Required for protection 61.07256118579 (A)

n= 19
Space between Anodes 3.79 (m)
Resistance of Anodes 0.349770252746
ρ (Soil resistivity) 500 (Ω.m)
W (Width of anode) 0.0127 (m)
H (depth of burial) 0.5 (m)

MMO ribbon anodes width (mm) 12.7 mm


thickness mm 0.635 mm
current output A/ 0.07 A/m
Anode Output 0.034 A/m
Anode Output 0.034 A/m

0 -4 -8 -11 -15 -19 -23 -27 -30 -34


72 72 70 68 65 61 56 49 39 23
Equipment list
Sr. Description unit quantity
1 Set 4
Mixed Metal Oxide Ribbon Anode (width 12.7 mm, thickness 0.635
2 m 4314
mm)

3 Titanium Conductor Bar ( width 12.7 mm, thikness 0.9 mm) m #REF!

4 Negative Bond Box(4-Terminal, Ex type) Item 4


5 Positive Bond Box (4-Terminal, Ex type) Item 4
6 XLPE/PVC Cable 1x35mm2 m 1000
7 Cable Lug 35 mm2 Item 30
8 Three-Way Splicing Kit Item 25
9 Liner (three way) Item 25
Negative connection assemblies (Approved to Zone 1 hazardous
10 item 4
area classification)
11 Resin Kg ?
12 Sleeve conduit m 20