You are on page 1of 1

H

Aganampudi

7
N

3-16Ø
3-16Ø GENERAL NOTES :
+2-12Ø

6
+2-12Ø 1. THIS DRAWING IS TO BE READ IN CONJUCTION
WITH MECHANICAL DRAWING.
3-12Ø 3-12Ø 2. THE GRADE OF CONCRETE SHALL BE M 25
3-16Ø 3-16Ø AS PER IS 456-2000.
+3-16Ø +3-16Ø 3. ALL REINFORCING STEEL SHALL BE OF
GRADE Fe 500 (#)
4. 43 GRADE ORDINARY PORTLAND CEMENT
3-16Ø 3-16Ø ACCORDING TO IS 8112-1987 SHALL BE USED.
3-16Ø

1.20
+2-16Ø +2-20Ø 5. MINIMUM CLEAR COVER TO MAIN REINF.:
FOOTING: 75 mm; COLUMN: 50 mm
3-12Ø

5
2-12Ø BEAMS: 25 mm; SLABS : 20 mm
6. LAPS FOR MAIN REINFORCEMENT
3-12Ø 50 x DIA. OF BAR - FOR COLUMNS.
Lift 60 x DIA. OF BAR - FOR BEAMS & SLABS.
9. LINK SPACING IN BETWEEN COLUMN - BEAM
JOINT SHALL BE 150 mm C/C
10. BEFORE CONCRETING IT MUST BE ENSURED
3-12Ø THAT EXCESS SHUTTERING OIL HAVE BEEN
3-16Ø 3-16Ø REMOVED FROM REINF. OF BEAM AND SLAB.
3-12Ø +3-16Ø +3-16Ø
10. USE OF RICH MIX FOR BEAM AND COLUMN
JOINT IS ADVISED.

4
11. ALL R.C.CONCRETE WORK SHALL BE
3-16Ø 3-16Ø 3-16Ø 3-16Ø MACHINE VIBRATED.
+3-20Ø +3-20Ø +3-20Ø +3-20Ø 12. MINIMUM STRIPPING TIME OF PROPS
PROPS UNDER SLAB
SLAB SPAN GREATER THAN 4.5m : 14 DAYS
3-16Ø 3-16Ø 3-16Ø SLAB SPAN UPTO 4.5m : 7 DAYS
+2-20Ø +2-20Ø +2-20Ø PROPS UNDER BEAM
BEAM SPAN GREATER THAN 6.0m : 21 DAYS
3-16Ø 3-16Ø BEAM SPAN UPTO 6.0m : 14 DAYS
+3-20Ø +3-20Ø 13. PROPER CURING TO ALL STRUCTURAL

3-16Ø MEMBERS IS ABSOLUTELY NECESSARY.

3
14. SAFE BEARING CAPACITY OF SOIL: 169 kN/m2
3-16Ø 15. IN CASE OF ANY DOUBT PLEASE ASK,
+3-16Ø 3-16Ø 3-16Ø DO NOT GUESS.
+2-12Ø 16. COLUMN SIZE UPTO PLINTH BEAM (C) = 1' X 1'6"
3-16Ø 3-16Ø
+2-16Ø +2-16Ø
3-12Ø
3-12Ø IMP.: STRUCTURAL CONSULTANT SHALL NOT BE

2
HELD RESPONSIBLE FOR ERRECTION OF
3-12Ø TEMPORARY STRUCTURE AND QUALITY OF
CONCRETE AND REINFORCING STEEL ON SITE
3-12Ø 3-16Ø 3-16Ø
3-16Ø 3-16Ø +2-16Ø GRADE OF CONCRETE M25
+2-16Ø +3-16Ø +2-16Ø GRADE OF STEEL Fe500

3-16Ø 3-16Ø 3-16Ø


+2-16Ø +2-16Ø +2-16Ø

1
NOTES:

ROOF BEAM REINFORCEMENT SHEET-1 All dimensions are in feet unless otherwise specified.
Grade of concrete: Prof. K.V.G.D. Balaji
* Stilt, Ground & First Floors Columns M30 M.Tech (Structures), Ph.D., FIE, FIPHE
* Foundations, All other Structural Members M25
"Y" denotes deformed reinforcement steel bars: Fe 500 GITAM University
Clear cover for reinforcement bars:
CONSTRUCTION OF * Footing = 75 mm and Column = 40mm Visakhapatnam, Andhra Pradesh
* Beam = 25mm and Slab = 20mm
(S+G+4) APPARTMENT Minimum Lap Length
S.B.C. assumed 220 kN/m as per Soil Report
50 x Dia
Prepared by:B.RAMESH Checked by:T Santosh kumar
This building is designed for S+G +4 GROUP HOUSE Date:29.10.2023
REV 1 ____________________