You are on page 1of 25

Armadale Line Upgrade Project

Victoria Park Early Works Development Application No. 1 – Viaduct Construction and Enabling Works

Appendix G - Retaining Walls and Abutment Plans (Plans,


Elevations, Typical Sections)

62 OUR VALUES: MORAL COURAGE | RAISING THE BAR | PEOPLE AND FAMILY
VICTORIA PARK TO CANNING LEVEL CROSSING REMOVAL
ZONE 0 - CIVIL STRUCTURES
PROJECT WIDE - ABUTMENTS & RETAINING WALLS

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
REV DATE AMENDMENT DSN DRN CHK APP DATE APPROVED
HORIZONTAL: PCG20 W.SCHWARZ COVER SHEET
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00001
DATE 24.06.2022 PTA Drawing No: 04-S-72-0001 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
DRAWING LIST
REV ALUA DRAWING NUMBER PTA DRAWING NUMBER TITLE
A01 LXR-PW-Z0-ST-RW-DWG-00001 04-S-72-0001 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - COVER SHEET
A01 LXR-PW-Z0-ST-RW-DWG-00002 04-S-72-0002 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - DRAWING INDEX
A01 LXR-PW-Z0-ST-RW-DWG-00003 04-S-72-0003 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - LOCALITY PLAN
A01 LXR-PW-Z0-ST-RW-DWG-00101 04-S-72-0007 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 1
A01 LXR-PW-Z0-ST-RW-DWG-00102 04-S-72-0008 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 2
A01 LXR-PW-Z0-ST-RW-DWG-00103 04-S-72-0009 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 3
A01 LXR-PW-Z0-ST-RW-DWG-00104 04-S-72-0010 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 4
A01 LXR-PW-Z0-ST-RW-DWG-00105 04-S-72-0011 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 5
A01 LXR-PW-Z0-ST-RW-DWG-00106 04-S-72-0012 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 6
A01 LXR-PW-Z0-ST-RW-DWG-00107 04-S-72-0013 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 7
A01 LXR-PW-Z0-ST-RW-DWG-00108 04-S-72-0014 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 8
A01 LXR-PW-Z0-ST-RW-DWG-00109 04-S-72-0015 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 9
A01 LXR-PW-Z0-ST-RW-DWG-00110 04-S-72-0016 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 10
A01 LXR-PW-Z0-ST-RW-DWG-00111 04-S-72-0017 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 11
A01 LXR-PW-Z0-ST-RW-DWG-00112 04-S-72-0018 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 12
A01 LXR-PW-Z0-ST-RW-DWG-00113 04-S-72-0019 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 13
A01 LXR-PW-Z0-ST-RW-DWG-00114 04-S-72-0020 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 14
A01 LXR-PW-Z0-ST-RW-DWG-00115 04-S-72-0021 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 15
A01 LXR-PW-Z0-ST-RW-DWG-00116 04-S-72-0022 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 16
A01 LXR-PW-Z0-ST-RW-DWG-00117 04-S-72-0023 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 17
A01 LXR-PW-Z0-ST-RW-DWG-00118 04-S-72-0024 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 18
A01 LXR-PW-Z0-ST-RW-DWG-00119 04-S-72-0025 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 19
A01 LXR-PW-Z0-ST-RW-DWG-00120 04-S-72-0026 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 20
A01 LXR-PW-Z0-ST-RW-DWG-00121 04-S-72-0027 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 21
A01 LXR-PW-Z0-ST-RW-DWG-00122 04-S-72-0028 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL PLAN AND ELEVATION - SHEET 22
A01 LXR-PW-Z0-ST-RW-DWG-00141 04-S-72-0037 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - ABUTMENT GENERAL ARRANGEMENT - SHEET 1
A01 LXR-PW-Z0-ST-RW-DWG-00142 04-S-72-0038 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - ABUTMENT GENERAL ARRANGEMENT - SHEET 2
A01 LXR-PW-Z0-ST-RW-DWG-00143 04-S-72-0039 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - ABUTMENT GENERAL ARRANGEMENT - SHEET 3
A01 LXR-PW-Z0-ST-RW-DWG-00151 04-S-72-0042 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - GENERAL SECTIONS - SHEET 1
A01 LXR-PW-Z0-ST-RW-DWG-00152 04-S-72-0043 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - GENERAL SECTIONS - SHEET 2
A01 LXR-PW-Z0-ST-RW-DWG-00153 04-S-72-0044 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - GENERAL SECTIONS - SHEET 3
A01 LXR-PW-Z0-ST-RW-DWG-00154 04-S-72-0045 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - GENERAL SECTIONS - SHEET 4
A01 LXR-PW-Z0-ST-RW-DWG-00155 04-S-72-0046 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - GENERAL SECTIONS - SHEET 5
A01 LXR-PW-Z0-ST-RW-DWG-00156 04-S-72-0047 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - GENERAL SECTIONS - SHEET 6
A01 LXR-PW-Z0-ST-RW-DWG-00161 04-S-72-0052 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL CONCRETE DETAILS - SHEET 1
A01 LXR-PW-Z0-ST-RW-DWG-00162 04-S-72-0053 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL CONCRETE DETAILS - SHEET 2
A01 LXR-PW-Z0-ST-RW-DWG-00163 04-S-72-0054 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL CONCRETE DETAILS - SHEET 3
A01 LXR-PW-Z0-ST-RW-DWG-00164 04-S-72-0055 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL CONCRETE DETAILS - SHEET 4
A01 LXR-PW-Z0-ST-RW-DWG-00165 04-S-72-0056 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL CONCRETE DETAILS - SHEET 5
A01 LXR-PW-Z0-ST-RW-DWG-00166 04-S-72-0057 PROJECT WIDE - ABUTMENTS & RETAINING WALLS - RETAINING WALL CONCRETE DETAILS - SHEET 6

1:100 (A1) / 1:200 (A3)


0 1m 2 3 4 5 6 7 8 9 10 11 12 13 14 15

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ DRAWING INDEX
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00002
DATE 24.06.2022 PTA Drawing No: 04-S-72-0002 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
MATCHLINE A-A MATCHLINE B-B MATCHLINE C-C
MILFORD

STREE
TUCKET
STREET

T
T
WAY
YALLAMBEE
STATION
STREET

BR
ST IGGS
RE
ET HAMILTON
BRIGGS STREET
STREET

GODWIT
STREET
HAMILTON
REFER TO DRG 04-S-72-0011 STREET

RUTLAND
AVENUE
CRAWFORD
PERTH

FORWARD STREET
STREET
VIADUCT 3 STREET
CRAWFORD

EMBANKMENT
(HAMILTON STREET

RAILWAY
PARADE
SEVENOAK
CRAWFORD

STREET
SUNBURY
STREET
SHEPPERTON

ROAD
TEAGUE
STREET
STREET

TO CANNINGTON STATION
ROAD

S
DORA

STREET

STREET
HENRY

RENOU
HOGARTH
STREET
EDWARD
STREET
ALBION

SYDNEY

MORGAN
WALTON

STREET

STREET
STREET
STREET

SEVENOAKS

RAILWAY
STREET
MARRIOT

PARADE
ROBERTS
ROAD
MILLER MILLER DEALY
STREET STREET CL

RUTLAND
AVENUE
STREET
BANK
EMBANKMENT TREASURE
ROAD LACEY
STREET

STOCKMAN
WAY

REFER TO DRG 04-S-72-0015

BISHOPSGATE
STREET

CENTRAL
TERRACE
RALEIGH
STREET
WE

RUTLAND
AVENUE
LS
RO HPO

HEAD
CL
AD OL

QUEENS PARK STATION

DRIV S
M
E
ADA

QUEENS PARK

CT RAIL
STATION

ND
DERISLEIGH

LA
STREET
SHEPPE

SANTINA
CARNARVON

BEATTY
AVENUE
ROAD

STREET

REFER TO DRG 04-S-72-0038

PL
BOULDER
RTON

STREET

EMBANKMENT BIC
RO KLEY
REFER TO DRG 04-S-72-0007 AD
AD
ST RIA
RE N
ET
PSP BRIDGE
(WELSHPOOL ROAD)

WELSHP
VIADUCT 2

ADAMS

BECKENHAM
DRIVE
STATION

STATION
GEORGE
CARDIFF
STREET

OOL
STREET

(WELSHPOOL ROAD) MALLARD


WAY WILLIAM

REFER TO DRG 04-S-72-0037 TOMLINSON


STREET

ROAD
WILLIAM
ARCHER
STREET
STREET
TATE

STREATHAM
STREET

STREET
TOLEDO
MINT WE
LS

CL
STREET RO HPO
AD OL

CARSLIE STATION REFER TO DRG 04-S-72-0019


BIC
KL
ROA EY
CARLISLE
STATION

HOLTON
WAY
WAKEFIELD
STREET EMBANKMENT WHARF
STREET
BEATTY
AVENUE

SEVENOAK
LINDEN

STREET
CARNARVON

RAILWAY
LAKE VIEW WHARF

PARADE
STREET

STREET CL
STREET
BISHOPSGATE
RUTLAND
AVENUE

STREET
RENOU
STREET

S
RALEIGH
STREET
STREET
BANK

JOHN
STREET

AVENUE
MONA

RAILWAY
CLAPHAM

SEVENOAKS

PARADE
STREET
JOHN STREET
STREET PRINCE

CAMBERWELL
PRINCE STREET

STREET

STREATHAM
STREET

STREET
MEMORIAL
AVENUE

NORSEMAN
STREET
FITZROY
STREET FITZROY
STREET

SEVENOAKS

AL HW
HIG
BA AY
STREET
CHARLES
DULWICH

STREET

NY
STREET
LION CH BECKENHAM
STREET LEA AY
HW STREET
HIG

RAILWAY
PARADE
SEVENOAK
STREET
DANE
STREET

S
WELLINGTON
STREET

EWING STREET
NORTH

STREET
RENOU
EWING
ANGLESEA STREET
STREET CUNNINGTON
RALEIGH

WAY
STREET
CARNARVON

JUPITER
STREET
STREET

AVENUE
BEATTY

CANNINGTON STATION
VIADUCT 1 THOMAS

CANNINGTON
STREET
MAUDE

STREET

STATION
LAKE
STREET

(MINT STREET H
AC Y
CEC
AVE IL
LE HWA NUE
TO OAT STREET) HIG

BLAIR ATHOL
STREET

RAILWAY
PARADE
GIBBS
MERCURY STREET
STREET GROSE
AVENUE REFER TO DRG 04-S-72-0039
STREE

SOMERSET
BANK

STREET
T

RADIUM

STREET
RENOU
STREET
RALEIGH
STREET

KALGAN
JUPITER
STREET

ROAD
REFER TO DRG 04-S-72-0027
STREE
TUCKET

TILLI PL
T
T

EMBANKMENT

STREET
LAKE
RAILWAY
AVEN
RUTLA

PARADE
SEVENOAK
STREET
UE
ND

WITHNELL
S

STREET CL GERARD
STREET

STREET
READ

MERIAN

EMBANKMENT
CHANNON
STREET

GERARD

SEVENOAKS
OATS STREET

STREET
STREET

OATS STREET STATION


OAT ST

OATS
REFER TO DRG 04-S-72-0023
STATI

ARMADALE
STREET
DANTE
ON

CT
REET

JAMERSON
RALEIGH

STREET
STREET

WEDGE
JUPITER

STREET
STREET

RENOU
STREE
TUCKET

PL

MERIAN

STREET
HENRY
CL
T
T

STREET
MILLS
BENT
STREET
FAIRWAY

MILLS
MEUSE
STREE
BANK

STREET
T

COHN
STREET

HOGARTH

RAILWAY
STATION

PARADE
STREET
MORGAN
STREET

STREET

MATCHLINE A-A MATCHLINE B-B MATCHLINE C-C

LOCALITY PLAN LEGEND:


SCALE 1 : 5000 VIADUCT / PSP BRIDGE
EMBANKMENT
STATION
RAIL ALIGNMENT
RAIL RESERVE BOUNDARY
REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
As indicated DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ LOCALITY PLAN
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00003
DATE 24.06.2022 PTA Drawing No: 04-S-72-0003 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
CARLISLE
STATION
OATS STREET
RAIL RESERVE NT ET
MI RE STATION
BOUNDARY ST

04-S-72-0008
WELSHPOOL

ET
RE
RUTLAND AVENUE

ST
WELSHP

TS
OOL ROA
D

OA

AL HWA
HIG
BA Y
QUEENS PARK

NY

AY
STATION

HW
HIG
T
EE
CANNINGTON

H
TR

AC
NS

LE
O
MI
LT EE
T STATION
A R
H ST
R F
A
WH
BECKENHAM
PRECAST RETAINING WALL PROPOSED
STATION

CH. 5600
PANELS ALONG DOWN MAIN DOWN MAIN ET
RE
ST
M
PERTH IA
ILL
W

LOCALITY PLAN

NOTES:
1. NOISE WALL NOT SHOWN
ARMADALE 2. RIGID INCLUSION NOT SHOWN
(+ve CHAINAGE) 3. WALL FLARE OUT FOR SIGNAL ZONE NOT SHOWN
4. TOP OF WALL ELEVATIONS SHALL BE DETERMINED

CH. 5600
FROM THE TOP OF RAIL ELEVATION

LEGEND:
RETAINING WALL
VIADUCT / PSP BRIDGE
RAIL ALIGNMENT
RAIL RESERVE BOUNDARY

MATCHLINE
PRECAST RETAINING WALL PROPOSED RAIL RESERVE
PANELS ALONG UP MAIN UP MAIN BOUNDARY

RETAINING WALL PLAN - MINT STREET TO OATS STREET


SCALE 1 : 250

04-S-72-0008
46000 44000 4000 40000
(RW2.0) (RW3.0) (RW4.0) (RW4.0)
TOP OF RETAINING WALL
TOP OF RETAINING WALL DESIGN GROUND LEVEL AT TOE PROPOSED TOP OF RAIL TRANSITION PANEL, TOP
ELEVATION VAIRES WITH
ELEVATION VAIRES WITH OF RETAINING WALL, SEE CIVIL OF WALL ROUNDED (TYP.)
1100 HIGH TOP OF RAIL
TOP OF FORMATION LEVEL DRAWINGS FOR ELEVATION
HANDRAIL (TYP.)

MATCHLINE
BASE OF RETAINING WALL

RETAINING WALL ELEVATION - MINT STREET TO OATS STREET (UP MAIN)


SCALE 1 : 250

1:250 (A1) / 1:500 (A3)


0 2.5m 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
As indicated DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ RETAINING WALL PLAN AND ELEVATION - SHEET 1
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00101
DATE 24.06.2022 PTA Drawing No: 04-S-72-0007 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
CARLISLE
STATION
OATS STREET
RAIL RESERVE NT ET
MI RE STATION
BOUNDARY ST

04-S-72-0007
WELSHPOOL

ET
RE
ST
RUTLAND AVENUE WELSHP

TS
OOL ROA
D

OA

AL HWA
HIG
BA Y
QUEENS PARK

NY

AY
STATION

HW
HIG
T
EE
CANNINGTON

H
TR

AC
NS

LE
O
MI
LT EE
T STATION
A R
H ST
R F
A
WH
BECKENHAM
STATION
ET
RE
ST
M
IA
ILL
CL ABUTMENT No. 1 W
PRECAST RETAINING WALL PROPOSED
PANELS ALONG DOWN MAIN DOWN MAIN
DEFLECTION WALL (TYP.) LOCALITY PLAN

CH. 5800
VIADUCT PACKAGE
TRANSITION SLABS
REFER DRG 04-S-169-0001
NOTES:
1. NOISE WALL NOT SHOWN
PERTH 2. RIGID INCLUSION NOT SHOWN
3. WALL FLARE OUT FOR SIGNAL ZONE NOT SHOWN
ARMADALE
4. TOP OF WALL ELEVATIONS SHALL BE DETERMINED
(+ve CHAINAGE) FROM THE TOP OF RAIL ELEVATION

LEGEND:
RETAINING WALL
VIADUCT / PSP BRIDGE
CH. 5700

CH. 5800
RAIL ALIGNMENT
RAIL RESERVE BOUNDARY
MATCHLINE

PRECAST RETAINING WALL PROPOSED RAIL RESERVE VIADUCT (MINT STREET


PANELS ALONG UP MAIN UP MAIN BOUNDARY TO OATS STREET)

RETAINING WALL PLAN - MINT STREET TO OATS STREET


SCALE 1 : 250

TOP OF WALL ELEVATION MATCH THE


VIADUCT GIRDER TOP FLANGE LEVEL AND
THEN VARIES WITH TOP OF RAIL IN THE
EMBANKMENT OR TOP OF FORMATION LEVEL CL ABUTMENT No.1
04-S-72-0007

48000 34000 845


VIADUCT PACKAGE
(RW4.0) (RW5.0) (RW6.0) (RW6.0)
REFER DRG 04-S-169-0001
PROPOSED TOP OF RAIL TOP OF RETAINING WALL
DESIGN GROUND LEVEL AT TOE ELEVATION VARIES WITH VIADUCT GIRDER
OF RETAINING WALL, SEE CIVIL
DRAWINGS FOR ELEVATION
TOP OF RAIL TBC RL: 21.942

ABUTMENT WALL

RL: 12.920
MATCHLINE

DEFLECTION WALL
BASE OF RETAINING WALL
ABUTMENT PILE CAP

RETAINING WALL ELEVATION - MINT STREET TO OATS STREET (UP MAIN)


SCALE 1 : 250

1:250 (A1) / 1:500 (A3)


0 2.5m 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
As indicated DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ RETAINING WALL PLAN AND ELEVATION - SHEET 2
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00102
DATE 24.06.2022 PTA Drawing No: 04-S-72-0008 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
CARLISLE
STATION
OATS STREET
RAIL RESERVE NT ET
MI RE STATION
BOUNDARY ST

04-S-72-0010
WELSHPOOL

ET
RE
RUTLAND AVENUE

ST
WELSHP

TS
OOL ROA
D

OA

AL HWA
HIG
BA Y
QUEENS PARK

NY

AY
STATION

HW
HIG
T
EE
CANNINGTON

H
TR

AC
NS

LE
O
MI
LT EE
T STATION
A R
H ST
R F
A
WH
BECKENHAM
PRECAST RETAINING WALL PROPOSED
STATION

CH. 5600
PANELS ALONG DOWN MAIN DOWN MAIN ET
RE
ST
M
PERTH IA
ILL
W

LOCALITY PLAN

NOTES:
1. NOISE WALL NOT SHOWN
ARMADALE 2. RIGID INCLUSION NOT SHOWN
(+ve CHAINAGE) 3. WALL FLARE OUT FOR SIGNAL ZONE NOT SHOWN
4. TOP OF WALL ELEVATIONS SHALL BE DETERMINED

CH. 5600
FROM THE TOP OF RAIL ELEVATION

LEGEND:
RETAINING WALL
VIADUCT / PSP BRIDGE
RAIL ALIGNMENT
RAIL RESERVE BOUNDARY

MATCHLINE
PRECAST RETAINING WALL PROPOSED RAIL RESERVE
PANELS ALONG UP MAIN UP MAIN BOUNDARY

RETAINING WALL PLAN - MINT STREET TO OATS STREET


SCALE 1 : 250

04-S-72-0010
42000 48000 4000 40000
(RW2.0) (RW3.0) (RW4.0) (RW4.0)
TRANSITION PANEL, TOP
OF WALL ROUNDED (TYP.) TOP OF RETAINING WALL
DESIGN GROUND LEVEL AT TOE
TOP OF RETAINING WALL ELEVATION VARIES WITH
OF RETAINING WALL, SEE CIVIL TOP OF RAIL
ELEVATION VARIES WITH PROPOSED TOP OF RAIL
1100 HIGH DRAWINGS FOR ELEVATION
TOP OF FORMATION LEVEL
HANDRAIL (TYP.)

MATCHLINE
BASE OF RETAINING WALL

RETAINING WALL ELEVATION - MINT STREET TO OATS STREET (DOWN MAIN)


SCALE 1 : 250

1:250 (A1) / 1:500 (A3)


0 2.5m 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
As indicated DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ RETAINING WALL PLAN AND ELEVATION - SHEET 3
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00103
DATE 24.06.2022 PTA Drawing No: 04-S-72-0009 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
CARLISLE
STATION
OATS STREET
RAIL RESERVE NT ET
MI RE STATION
BOUNDARY ST

04-S-72-0009
WELSHPOOL

ET
RE
ST
RUTLAND AVENUE WELSHP

TS
OOL ROA
D

OA

AL HWA
HIG
BA Y
QUEENS PARK

NY

AY
STATION

HW
HIG
T
EE
CANNINGTON

H
TR

AC
NS

LE
O
MI
LT EE
T STATION
A R
H ST
R F
A
WH
BECKENHAM
STATION
ET
RE
ST
M
IA
ILL
CL ABUTMENT No. 1 W
PRECAST RETAINING WALL PROPOSED
PANELS ALONG DOWN MAIN DOWN MAIN
DEFLECTION WALL (TYP.) LOCALITY PLAN

CH. 5800
VIADUCT PACKAGE
TRANSITION SLABS
REFER DRG 04-S-169-0001
NOTES:
1. NOISE WALL NOT SHOWN
PERTH 2. RIGID INCLUSION NOT SHOWN
3. WALL FLARE OUT FOR SIGNAL ZONE NOT SHOWN
ARMADALE
4. TOP OF WALL ELEVATIONS SHALL BE DETERMINED
(+ve CHAINAGE) FROM THE TOP OF RAIL ELEVATION

LEGEND:
RETAINING WALL
VIADUCT / PSP BRIDGE
CH. 5700

CH. 5800
MATCHLINE

RAIL ALIGNMENT
RAIL RESERVE BOUNDARY

PRECAST RETAINING WALL PROPOSED RAIL RESERVE VIADUCT (MINT STREET


PANELS ALONG UP MAIN UP MAIN BOUNDARY TO OATS STREET)

RETAINING WALL PLAN - MINT STREET TO OATS STREET


SCALE 1 : 250

TOP OF WALL ELEVATION MATCH THE


VIADUCT GIRDER TOP FLANGE LEVEL AND
THEN VARIES WITH TOP OF RAIL IN THE
EMBANKMENT OR TOP OF FORMATION LEVEL
04-S-72-0009

46000 38000 CL ABUTMENT No.1


(RW4.0) (RW5.0) (RW6.0) VIADUCT PACKAGE
DESIGN GROUND LEVEL AT TOE PROPOSED TOP OF RAIL TOP OF RETAINING WALL REFER DRG 04-S-169-0001
OF RETAINING WALL, SEE CIVIL ELEVATION VARIES WITH VIADUCT GIRDER
DRAWINGS FOR ELEVATION TOP OF RAIL
RL: 21.942

ABUTMENT WALL
MATCHLINE

RL: 12.920

BASE OF RETAINING WALL


ABUTMENT PILE CAP

RETAINING WALL ELEVATION - MINT STREET TO OATS STREET (DOWN MAIN)


SCALE 1 : 250

1:250 (A1) / 1:500 (A3)


0 2.5m 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
As indicated DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ RETAINING WALL PLAN AND ELEVATION - SHEET 4
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00104
DATE 24.06.2022 PTA Drawing No: 04-S-72-0010 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
CARLISLE
STATION
OATS STREET
NT ET

04-S-72-0012
MI RE STATION
ST
WELSHPOOL

ET
RE
RUTLAND AVENUE

ST
WELSHP

TS
OOL ROA
D

OA

AL HWA
RAIL RESERVE

HIG
BA Y
QUEENS PARK

NY
BOUNDARY

AY
STATION

HW
HIG
T
EE
CANNINGTON

H
TR

AC
NS

LE
O
MI
LT EE
T STATION
A R
H ST
R F
A
WH
BECKENHAM
STATION
ET
CL ABUTMENT No.2 RE
ST
PRECAST RETAINING WALL PROPOSED M
IA

CH. 7300
VIADUCT PACKAGE DEFLECTION WALL (TYP.) PANELS ALONG DOWN MAIN DOWN MAIN ILL
W
REFER DRG 04-S-169-0001 TRANSITION SLABS
LOCALITY PLAN

ARMADALE NOTES:
PERTH (+ve CHAINAGE) 1. NOISE WALL NOT SHOWN
2. RIGID INCLUSION NOT SHOWN
3. WALL FLARE OUT FOR SIGNAL ZONE NOT SHOWN
4. TOP OF WALL ELEVATIONS SHALL BE DETERMINED
FROM THE TOP OF RAIL ELEVATION

CH. 7300
VIADUCT (MINT STREET
TO OATS STREET) LEGEND:
RETAINING WALL
VIADUCT / PSP BRIDGE
RAIL ALIGNMENT
RAIL RESERVE BOUNDARY

PRECAST RETAINING WALL PROPOSED RAIL RESERVE


PANELS ALONG UP MAIN UP MAIN BOUNDARY

MATCHLINE
RETAINING WALL PLAN - MINT STREET TO OATS STREET
SCALE 1 : 250

CL ABUTMENT No.2
TOP OF WALL ELEVATION MATCH THE
VIADUCT GIRDER TOP FLANGE LEVEL AND
THEN VARIES WITH TOP OF RAIL IN THE

04-S-72-0012
EMBANKMENT OR TOP OF FORMATION LEVEL
VIADUCT PACKAGE
REFER DRG 04-S-169-0001 870 60000 38000
(RW5.0) (RW5.0) (RW4.0)
TOP OF RETAINING WALL DESIGN GROUND LEVEL AT TOE
VIADUCT GIRDER
RL: 21.288 TBC ELEVATION VARIES WITH
TOP OF RAIL
PROPOSED TOP OF RAIL OF RETAINING WALL, SEE CIVIL
DRAWINGS FOR ELEVATION

ABUTMENT WALL
RL: 14.181

MATCHLINE
BASE OF RETAINING WALL
ABUTMENT PILE CAP

RETAINING WALL ELEVATION - MINT STREET TO OATS STREET (UP MAIN)


SCALE 1 : 250
1:250 (A1) / 1:500 (A3)
0 2.5m 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
As indicated DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ RETAINING WALL PLAN AND ELEVATION - SHEET 5
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00105
DATE 24.06.2022 PTA Drawing No: 04-S-72-0011 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
CARLISLE
STATION
OATS STREET
NT ET
MI RE STATION
ST
WELSHPOOL

T
04-S-72-0011

E
RE
RUTLAND AVENUE

ST
RAIL RESERVE WELSHP

TS
OOL ROA
D

OA
BOUNDARY

AL HWA
HIG
BA Y
QUEENS PARK

NY

AY
STATION

HW
HIG
T
EE
CANNINGTON

H
TR

AC
NS

LE
O
MI
LT EE
T STATION
A R
H ST
R F
A
WH
BECKENHAM
STATION
ET
RE
PRECAST RETAINING WALL PROPOSED LE ST
ARMADA AGE)

CH . 74 00
M
PANELS ALONG DOWN MAIN DOWN MAIN IN IA
(+ve CHA W
ILL

LOCALITY PLAN

NOTES:
1. NOISE WALL NOT SHOWN
2. RIGID INCLUSION NOT SHOWN
3. WALL FLARE OUT FOR SIGNAL ZONE NOT SHOWN
PERTH 4. TOP OF WALL ELEVATIONS SHALL BE DETERMINED
FROM THE TOP OF RAIL ELEVATION

CH . 74 00
LEGEND:
RETAINING WALL
VIADUCT / PSP BRIDGE
RAIL ALIGNMENT
RAIL RESERVE BOUNDARY

PRECAST RETAINING WALL PROPOSED RAIL RESERVE


PANELS ALONG UP MAIN UP MAIN BOUNDARY
MATCHLINE

RETAINING WALL PLAN - MINT STREET TO OATS STREET


SCALE 1 : 250
04-S-72-0011

4000 40000 28000


(RW4.0) (RW4.0) (RW3.0) (RW2.0)

TOP OF RETAINING WALL TRANSITION PANEL, TOP OF TOP OF RETAINING WALL


DESIGN GROUND LEVEL AT TOE
ELEVATION VARIES WITH WALL ROUNDED (TYP.) ELEVATION VARIES WITH
OF RETAINING WALL, SEE CIVIL
TOP OF RAIL TOP OF FORMATION LEVEL
PROPOSED TOP OF RAIL DRAWINGS FOR ELEVATION
1100 HIGH HANDRAIL
(TYP.)
MATCHLINE

BASE OF RETAINING WALL

RETAINING WALL ELEVATION - MINT STREET TO OATS STREET (UP MAIN)


SCALE 1 : 250
1:250 (A1) / 1:500 (A3)
0 2.5m 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
As indicated DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ RETAINING WALL PLAN AND ELEVATION - SHEET 6
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00106
DATE 24.06.2022 PTA Drawing No: 04-S-72-0012 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
CARLISLE
STATION
OATS STREET

04-S-72-0014
NT ET
MI RE STATION
ST
WELSHPOOL

T
RUTLAND AVENUE

E
RE
ST
WELSHP

TS
OOL ROA
D

OA
RAIL RESERVE

AL HWA
HIG
BOUNDARY

BA Y
QUEENS PARK

NY

AY
STATION

HW
HIG
T
EE
CANNINGTON

H
TR

AC
NS

LE
O
MI
LT EE
T STATION
A R
H ST
R F
A
WH
BECKENHAM
STATION
CL ABUTMENT No.2 ET
RE
PRECAST RETAINING WALL PROPOSED ST

CH. 7300
M
VIADUCT PACKAGE DEFLECTION WALL (TYP.) PANELS ALONG DOWN MAIN DOWN MAIN IA
ILL
W
REFER DRG 04-S-169-0001 TRANSITION SLABS
LOCALITY PLAN

ARMADALE
PERTH (+ve CHAINAGE) NOTES:
1. NOISE WALL NOT SHOWN
2. RIGID INCLUSION NOT SHOWN
3. WALL FLARE OUT FOR SIGNAL ZONE NOT SHOWN
4. TOP OF WALL ELEVATIONS SHALL BE DETERMINED
FROM THE TOP OF RAIL ELEVATION

CH. 7300
VIADUCT (MINT STREET
TO OATS STREET) LEGEND:
RETAINING WALL
VIADUCT / PSP BRIDGE
RAIL ALIGNMENT
RAIL RESERVE BOUNDARY

PRECAST RETAINING WALL PROPOSED RAIL RESERVE


PANELS ALONG UP MAIN UP MAIN BOUNDARY

MATCHLINE
RETAINING WALL PLAN - MINT STREET TO OATS STREET
SCALE 1 : 250

CL ABUTMENT No.2
22000 36000 26000

04-S-72-0014
(RW6.0) (RW5.0) (RW4.0)
VIADUCT PACKAGE TOP OF WALL ELEVATION MATCH THE
TOP OF RETAINING WALL DESIGN GROUND LEVEL AT TOE
REFER DRG 04-S-169-0001 VIADUCT GIRDER TOP FLANGE LEVEL AND
ELEVATION VARIES WITH OF RETAINING WALL, SEE CIVIL
THEN VARIES WITH TOP OF RAIL IN THE
VIADUCT GIRDER TOP OF RAIL DRAWINGS FOR ELEVATION
EMBANKMENT OR TOP OF FORMATION LEVEL PROPOSED TOP OF RAIL
RL: 22.288

ABUTMENT WALL

RL: 14.181

MATCHLINE
DEFLECTION WALL BASE OF RETAINING WALL
ABUTMENT PILE CAP

RETAINING WALL ELEVATION - MINT STREET TO OATS STREET (DOWN MAIN)


SCALE 1 : 250

1:250 (A1) / 1:500 (A3)


0 2.5m 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
As indicated DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ RETAINING WALL PLAN AND ELEVATION - SHEET 7
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00107
DATE 24.06.2022 PTA Drawing No: 04-S-72-0013 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
CARLISLE
STATION
OATS STREET
NT ET
MI RE STATION
ST
WELSHPOOL

ET
04-S-72-0013

RE
RUTLAND AVENUE

ST
WELSHP
RAIL RESERVE

TS
OOL ROA
D

OA
BOUNDARY

AL HWA
HIG
BA Y
QUEENS PARK

NY

AY
STATION

HW
HIG
T
EE
CANNINGTON

H
TR

AC
NS

LE
O
MI
LT EE
T STATION
A R
H ST
R F
A
WH
BECKENHAM
STATION
ET
RE
PRECAST RETAINING WALL PROPOSED LE ST
ARMADA AGE)

CH . 74 00
M
IA
PANELS ALONG DOWN MAIN DOWN MAIN IN ILL
(+ve CHA W

LOCALITY PLAN

NOTES:
1. NOISE WALL NOT SHOWN
2. RIGID INCLUSION NOT SHOWN
3. WALL FLARE OUT FOR SIGNAL ZONE NOT SHOWN
PERTH 4. TOP OF WALL ELEVATIONS SHALL BE DETERMINED
FROM THE TOP OF RAIL ELEVATION

CH . 74 00
LEGEND:
RETAINING WALL
VIADUCT / PSP BRIDGE
RAIL ALIGNMENT
RAIL RESERVE BOUNDARY

PRECAST RETAINING WALL PROPOSED RAIL RESERVE


PANELS ALONG UP MAIN UP MAIN BOUNDARY
MATCHLINE

RETAINING WALL PLAN - MINT STREET TO OATS STREET


SCALE 1 : 250
04-S-72-0013

4000 46000 28000


(RW4.0) (RW4.0) (RW2.0) (RW2.0)
TOP OF RETAINING WALL
ELEVATION VARIES WITH
TOP OF RAIL
TRANSITION PANEL, PROPOSED TOP OF RAIL TOP OF RETAINING WALL 1100 HIGH HANDRAIL DESIGN GROUND LEVEL AT TOE
TOP OF WALL ROUNDED ELEVATION VARIES WITH (TYP.) OF RETAINING WALL, SEE CIVIL
(TYP.) TOP OF FORMATION LEVEL DRAWINGS FOR ELEVATION
MATCHLINE

BASE OF RETAINING WALL

RETAINING WALL ELEVATION - MINT STREET TO OATS STREET (DOWN MAIN)


SCALE 1 : 250

1:250 (A1) / 1:500 (A3)


0 2.5m 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
As indicated DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ RETAINING WALL PLAN AND ELEVATION - SHEET 8
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00108
DATE 24.06.2022 PTA Drawing No: 04-S-72-0014 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
B CARLISLE
0042 STATION
OATS STREET
CL ABUTMENT NT ET
MI RE STATION
ST
RETAINING WALL RETURNS
AND TIE TO DEFLECTION WALL WELSHPOOL

T
ARCHITECTURAL SCREEN

E
RE
RETAINING WALL DEFLECTION WALL

ST
(TYP.) WELSHP
EDGE OF WALKWAY ARCHITECTURAL SCREEN

TS
OOL ROA
250 D

OA
MCR TROUGH WITH FRANGIBLE STEEL SUPPORT SETOUT CL ABUTMENT

AL HWA
GAP

HIG
BA Y
TRAFFICABLE LID STAIRS (TYP.) INDICATIVE ONLY (TYP.) BORED PILE (TYP.) QUEENS PARK

NY

AY
WALKWAY

STATION

HW
HIG
T
VIADUCT EE
CANNINGTON

H
TR

AC
HANDRAIL NS

LE
O
MI
LT EE
T STATION
A R
H ST
R F
A
A WH
BECKENHAM
UPVC DOWN PIPE AND
0037
OUTFALL TO DRAINAGE STATION
ET
GULLY ON CAP RE
ST
TRACK CL DOWN M
CENTRAL IA
APPROACH ILL
RUN-ON SLAB TRACK SLAB WITH DEFLECTION CL PILE CAP W
SLAB
UPSTANDS WALL
(BELOW) 4000
LOCALITY PLAN
TRACK CL UP ABUTMENT WALL

1100 HIGH VIADUCT BEAM


HANDRAIL (TYP.) IN-SITU CONCRETE
(TYP.)
ABUTMENT PILE CAP
WALKWAY

VIADUCT
HANDRAIL
EDGE OF
ABUTMENT WALKWAY
DRAINAGE CHANNEL MCR TROUGH WITH REAR STAND FENDER WALL
WITH TRAFFICABLE LID TRAFFICABLE LID DEFLECTION WALL (BELOW) (TYP.)

RETAINING WALL RETAINING W


ALL VIADUCT HANDRAIL TYPICAL PLAN - ABUTMENT PILECAP
EXTENSION (TYP.) SCALE 1 : 100
RETAINING WALL RETURNS
AND TIE TO DEFLECTION WALL CL ABUTMENT
200x13 NEOPRENE
BEARING STRIP
TRACK SLAB
TOP OF RAIL
TYPICAL PLAN - DEFLECTION WALL TO RETAINING WALL TRANSITION
SCALE 1 : 100

506
TOP OF WALL ELEVATION MATCH THE 200
VIADUCT GIRDER TOP FLANGE LEVEL AND SCREED WITH

400
THEM VARIES WITH TOP OF RAIL IN THE EPOXY GROUT

300
EMBANKMENT OR TOP OF FORMATION LEVEL CL ABUTMENT

VIADUCT GIRDER APPROACH SLAB


10000 2000 8500

300
25x25 CHAMFER (TYP.) VIADUCT GIRDER

300
(TYP.)

50
ABUTMENT WALL
SLAB TRACK GAP REAR UPSTAND
1200
506

SPHERICAL BEARING
700

(TYP.)
(TYP.) TOP OF RAIL 1

1350
1 400 BITUTHENE
600 5000 WPM
N24 SS DOWEL
20 AT 300 SPACING
400 ABUTMENT WALL
RUN-ON SLAB GAP WITH
SEALANT N24 REBARS BENT
WITH 250 DIA. PIN
APPROACH SLAB DRAINAGE DOWNPIPE,
1
REFER TO CIVIL DRAWING
0037

600
DEFLECTION WALL GROUND LEVEL
(BEYOND) ABUTMENT WALL
1000
MIN.

350

ABUTMENT
PILE CAP

BORED PILE 600


(TYP.)
1050 900

TYPICAL VIADUCT ABUTMENT

SECTION A DETAIL 1 1:100 (A1) / 1:200 (A3)


0 1m 2 3 4 5 6 7 8 9 10 11 12 13 14 15
SCALE 1 : 100 0037 SCALE 1 : 20 0037
REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
As indicated DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ ABUTMENT GENERAL ARRANGEMENT - SHEET 1
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00141
DATE 24.06.2022 PTA Drawing No: 04-S-72-0037 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
CL UP MAIN CL DOWN MAIN

10950 MIN.
OVERALL
2875 MIN. 5200 MIN. 2875 MIN.

CL UP MAIN
2875 MIN.

ARCHITECTURAL SCREEN
WITH HANDRAIL AND MCR
(TYP.) ARCHITECTURAL SCREEN
WITH HANDRAIL AND MCR
(TYP.)
1260 MAX

VIADUCT GIRDER
1200 MIN.

1260 MAX.
1200 MIN.
(TYP.)

(TYP.)
(TYP.)

2210
2210
VIADUCT GIRDER
(TYP.)
FENDER WALL
FENDER WALL (TYP.)
(TYP.) HANDRAIL
TRACK SLAB
TRACK SLAB (TYP.)
(TYP.)
ABUTMENT
ABUTMENT WALL ABUTMENT REAR STAND
REAR STAND
BEARING (TYP.)
RETAINING WALL
BEARING (TYP.)
DEFLECTION WALL

VARIES
TRACK DRAINAGE (BEHIND)
VARIES

DEFLECTION WALL DEFLECTION WALL


(BEHIND) (BEHIND) DOWNPIPE
ABUTMENT WALL
DESIGN GROUND
DOWNPIPE LEVEL

DESIGN GROUND

1000
MIN.
LEVEL

ABUTMENT
ABUTMENT DRAINAGE DRAINAGE OUTLET
OUTLET
1000
MIN.

IN-SITU PILECAP

TYPICAL ABUTMENT ELEVATION (CANNINGTON)

BORED PILE SECTION E


(TYP.) 0039
SCALE 1 : 50

TYPICAL ABUTMENT ELEVATION

1:50 (A1) / 1:100 (A3)


SECTION B 0 0.5m 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5

SCALE 1 : 50 0037
REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
1 : 50 DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ GENERAL SECTIONS - SHEET 1
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00151
DATE 24.06.2022 PTA Drawing No: 04-S-72-0042 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
CL DOWN MAIN CL PSP BRIDGE

B HANDRAIL (TYP.) FENCE HANDRAIL (TYP.), CL ABUTMENT


OPEN DRAINAGE 0043 INDICATIVE ONLY RETAINING WALL,
VIADUCT GIRDER
CHANNEL (BEHIND) HEIGHT VARIES
RETAINING WALL PSP BRIDGE
SEAT TYPE PSP ABUTMENT WITH
FINISHED GROUND
UPSTAND WITH GRANOR P2
LEVEL (BEHIND) PSP BRIDGE
HANDRAIL STRIPSEAL AT EACH ABUTMENT

(TYP.)
250

2163

179
1000
DEFLECTION WALL

300
(BEHIND) BEARING (TYP.)

PSP ABUTMENT
WALL
RETAINING WALL
IN-SITU ABUTMENT
(BEHIND), HEIGHT VARIES
WALL

800

VARIES
DESIGN GROUND
LEVEL
DESIGN GROUND
LEVEL
20
GAP

1000
MIN.
2000

800
IN-SITU PILE CAP
600 DIA. RIGID INCLUSION
(TYP.), GROUND IMPROVEMENT 500
UNDER FOOTING TO MAINTAIN (TYP.)
SETTLEMENT BETWEEN 6400
RIGID INCLUSION
VIADUCT AND PSP BRIDGE
(TYP.)

TYPICAL ELEVATION - PSP ABUTMENT WALL (FRONT) TYPICAL SECTION OF PSP ABUTMENT WALL

SECTION A SECTION B
SCALE 1 : 50 0038 SCALE 1 : 50 0043

1:50 (A1) / 1:100 (A3)


0 0.5m 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
1 : 50 DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ GENERAL SECTIONS - SHEET 2
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00152
DATE 24.06.2022 PTA Drawing No: 04-S-72-0043 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
CL DOWN MAIN CL UP MAIN

CL PSP BRIDGE

VIADUCT WALKWAY
EXTENSION (TYP.) THE INSIDE PROFILE OF THE
DEFLECTION WALL TO MATCH
THAT OF THE VIADUCT GIRDER
WING WALL, WALKWAY AND TAPERS IN PLAN (TYP.)
WALKWAY
(HEIGHT VARIES
FENCE ALONG THE
FINISHED GROUND LEVEL LENGTH)
FENCE ARCHITECTURAL SCREEN
HANDRAIL (TYP.) WITH HANDRAIL AND MCR
RETAINING (TYP.)
PSP ABUTMENT
WALL
WALL
OPEN DRAIN
HANDRAIL TRACK SLAB
(TYP.)
1 TRANSITION SLAB
3 (TYP.)
DEFLECTION WALL

ABUTMENT WALL
REAR UPSTAND
IN-SITU ABUTMENT
WALL

DEFLECTION WALL
(CENTRAL)

800 800

DESIGN GROUND
LEVEL (BEHIND)

IN-SITU PILE CAP

600 DIA. RIGID INCLUSION


(TYP.), GROUND IMPROVEMENT
UNDER FOOTING TO MAINTAIN BORED PILE (TYP.)
SETTLEMENT BETWEEN
VIADUCT AND PSP BRIDGE

TYPICAL ELEVATION - PSP AND VIADUCT ABUTMENT WALL (BACK)

SECTION B
SCALE 1 : 50 0038

1:50 (A1) / 1:100 (A3)


0 0.5m 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
1 : 50 DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ GENERAL SECTIONS - SHEET 3
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00153
DATE 24.06.2022 PTA Drawing No: 04-S-72-0044 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
CL DOWN MAIN CL UP MAIN

5200 MIN.

4355
3925
2140 2140

CL WALKWAY 1000 (TYP.)


FENCE
WALKWAY
2000 2000
MASH TEST LEVEL 5 NOISE SCREEN (TYP.)
CONCRETE BARRIER - (FINISHING TO URBAN DESIGN)
CONSTANT SLOPE WHERE REQUIRED
HANDRAIL INSTALLED OPEN DRAINAGE
TO MANUFACTURER'S CHANNEL

MAX.
1070
DETAIL (TYP.)
1100

1100 HIGH HANDRAIL, REFER TWO


RAIL HANDRAIL ON PTA
250

1 STANDARD DRG. No. 00-S-12-0001


3 FALL AND TYPICAL LAYOUT ON DRG. No.
LXRD-ALUA-000-CS-DRG-20004
CONCRETED SUBGRADE (TYP.)
RETAINING WALL (TYP.)
DRAINAGE CHANNEL RETAINING WALL/CONTAINMENT
WALL (TYP.)
CLASS 2 BACKFILL TO AS 4678 MCR TROUGH WITH (FINISHING TO URBAN DESIGN)
TRAFFICABLE LID (TYP.)

100 THICK COMPACTED GRAVELx


1000 WIDE MAINTENANCE
WALKWAY (TYP. ALL FRONT
AREAS OF RETAINING WALLS)

BLINDING ON
1000
MIN.

COMPACTED SOIL RIGID INCLUSION


(TYP.)

TYPICAL SECTION - RETAINING WALL

SECTION C
SCALE 1 : 50 0038

1:50 (A1) / 1:100 (A3)


0 0.5m 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
1 : 50 DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ GENERAL SECTIONS - SHEET 4
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00154
DATE 24.06.2022 PTA Drawing No: 04-S-72-0045 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
CL DOWN MAIN CL UP MAIN

5200 MIN.

CL DOWN MAIN CL UP MAIN

5200 MIN.
3680 4355
3250 3925
2140 2140

TOP OF WALL ELEVATION MATCH 3680 4355


CONCRETE SLAB WITH VIADUCT GIRDER TOP
2140 2140
(TYP.) FLANGE LEVEL AND THEN VARIES
WITH TOP OF RAIL IN THE
EMBANKMENT OR TOP OF
1000 (TYP.)
NOISE SCREEN FORMATION LEVEL
WALKWAY
(TYP.)
(TYP.)
1800

(TYP.)

1100 HIGH CONTINUOUS


1200

1200
HANDRAIL (TYP.)
TOP OF WALL ELEVATION
1100 HIGH HANDRAIL MATCH WITH VIADUCT
1% CONCRETE 1000 (TYP.)
1% (TYP.) GIRDER TOP FLANGE
LEVEL AND THEN VARIES SLAB WALKWAY
WITH TOP OF RAIL IN THE (TYP.)
FALL EMBANKMENT OR TOP OF
CONCRETED SUBGRADE
FORMATION LEVEL

(TYP.)
250
(TYP.) RETAINING WALL 1100 HIGH HANDRAIL
CORE DRAIN /CONTAINMENT WALL (TYP.)
ACO K300 TRENCH DRAIN WITH (TYP.)
TYPE 847D STAINLESS 1%
WEDGEWIRE HEELSAFE ANTI-SLIP
GRATE OR EQUIVALENT
150 DIA. PERFORATED SUBSOIL DRAIN FALL
PIPE (TYP.) MIN. 0.5% GRADE. MCR TROUGH WITH CONCRETED SUBGRADE
CORE DRAIN
SURROUNDED WITH AGGREGATE OR TRAFFICABLE LID (TYP.)
ACO K300 TRENCH DRAIN WITH TYPE
WRAPPED IN GEOFABRIC 150 DIA. PERFORATED SUBSOIL DRAIN
COMPACTED GRAVEL 1000 WIDE 847D STAINLESS WEDGEWIRE HEELSAFE COMPACTED GRAVEL 1000 WIDE
PIPE (TYP.) MIN. 0.5% GRADE.
MAINTENANCE WALKWAY (TYP.) ANTI-SLIP GRATE OR EQUIVALENT MAINTENANCE WALKWAY (TYP.)
SURROUNDED WITH AGGREGATE OR
WRAPPED IN GEOFABRIC MCR TROUGH WITH
TRAFFICABLE LID (TYP.)
(TYP.)
500

BLINDING ON INSITU TIE SLAB BLINDING ON


INSITU TIE SLAB COMPACTED SOIL COMPACTED SOIL
RIGID INCLUSION
(TYP.)

TYPICAL SECTION - STITCHED PRECAST RETAINING WALL TYPICAL SECTION - STITCHED PRECAST RETAINING WALL
1:50 1:50

1100 HIGH HANDRAIL (AT


LOCATIONS WHERE DROP
EXCEEDS WITH 1000)

CADASTRAL BOUNDARY
DRAIN

FORMATION LEVEL
LIMESTONE WALL BLOCK
(TYP.)

BLINDING

1:50 (A1) / 1:100 (A3)


0 0.5m 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5
TYPICAL SECTION - LIMESTONE RETAINING WALL
1:50 REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
1 : 50 DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ GENERAL SECTIONS - SHEET 5
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00155
DATE 24.06.2022 PTA Drawing No: 04-S-72-0046 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
CL DOWN MAIN CL UP MAIN CL DOWN MAIN CL UP MAIN

5200 MIN. 5200 MIN.

4475 5170

4045 4355 3680 4740


2745 3925 TOP OF WALL ELEVATION 3250 2745
MATCH WITH VIADUCT
2140 2140 2140 2140
GIRDER TOP FLANGE LEVEL
AND THEN VARIES WITH TOP
OF RAIL IN THE EMBANKMENT
OR TOP OF FORMATION
A A
SIM. LEVEL
0047
0047

1000 (TYP.) 1000 (TYP.)


CONCRETE SLAB
WALKWAY WALKWAY
(TYP.)
NOISE SCREEN NOISE SCREEN
(TYP.) CONCRETE (TYP.)
SLAB
(TYP.)
(TYP.)

(TYP.)
1200

1200
1200
1100 HIGH HANDRAIL
(TYP.)
1% 1100 HIGH HANDRAIL
1% (TYP.) 1%

FALL FALL
CONCRETED SUBGRADE CONCRETED SUBGRADE
(TYP.) RETAINING WALL/CONTAINMENT (TYP.) RETAINING WALL/
CORE DRAIN WALL (TYP.) CORE DRAIN CONTAINMENT WALL
ACO K300 TRENCH DRAIN WITH
(TYP.)
TYPE 847D STAINLESS ACO K300 TRENCH DRAIN WITH
WEDGEWIRE HEELSAFE ANTI-SLIP TYPE 847D STAINLESS
VARIES

VARIES
GRATE OR EQUIVALENT WEDGEWIRE HEELSAFE ANTI-SLIP
150 DIA. PERFORATED SUBSOIL DRAIN 150 DIA. PERFORATED SUBSOIL DRAIN GRATE OR EQUIVALENT
PIPE (TYP.) MIN. 0.5% GRADE. MCR TROUGH WITH PIPE (TYP.) MIN. 0.5% GRADE.
SURROUNDED WITH AGGREGATE OR TRAFFICABLE LID (TYP.) SURROUNDED WITH AGGREGATE OR COMPACTED GRAVEL
WRAPPED IN GEOFABRIC WRAPPED IN GEOFABRIC MCR TROUGH WITH
TRAFFICABLE LID (TYP.) 1000 WIDE MAINTENANCE
COMPACTED GRAVEL 1000 WIDE
WALKWAY (TYP.)
MAINTENANCE WALKWAY (TYP.)
(TYP.)

(TYP.)
500

500
BLINDING ON BLINDING ON
INSITU TIE SLAB COMPACTED SOIL INSITU TIE SLAB COMPACTED SOIL
RIGID INCLUSION RIGID INCLUSION
(TYP.) (TYP.)

DOWN MAIN SIGNAL - LOCAL WIDENING UP MAIN SIGNAL - LOCAL WIDENING

TYPICAL SECTION - STITCHED PRECAST RETAINING WALL TYPICAL SECTION - STITCHED PRECAST RETAINING WALL
1:50 1:50
850 (DOWN MAIN)
810 (UP MAIN)

2000
3000 LONG
HANDRAIL CONCRETE SLAB
WALKWAY

SIGNAL ZONE
1000

MCR TROUGH WITH


(TYP.)

TRAFFICABLE LIDS
20°

PRECAST RETAINING
WALL PANEL

PLAN - TYPICAL LOCAL WIDENING AT SIGNAL ZONE

SECTION A
SCALE 1 : 50 0047
1:50 (A1) / 1:100 (A3)
0 0.5m 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
1 : 50 DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ GENERAL SECTIONS - SHEET 6
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00156
DATE 24.06.2022 PTA Drawing No: 04-S-72-0047 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
430 NOTES:
1. NO RETAINING WALLS REQUIRED BELOW H≤1000mm.
2. ALLOW FOR STABILITY BRACING OF THE RETAINING WALL
PRIOR TO BACKFILLING.
3. SEE PLAN AND ELEVATION DRAWINGS FOR NOISE WALL
LOCATIONS.
4. ONLY WALLS WHERE H>3000mm ARE TO WITHSTAND IMPACT

1200
LOAD OF 500kN.
5. WEIGHT OF PRECAST WALL FOR HANDLING PURPOSES (DOES
2600 x 30 NOT INCLUDE IN-SITU CONCRETE)

1838
ARCHITECTURAL ZONE TOP OF RAIL LEVEL

REFER GENERAL ARRANGEMENT PLAN AND ELEVATION

638
FORMATION LEVEL FOR LOCATIONS OF RETAINING WALL

1962
700
8400 (MAX)
OVERALL

RETAINING HEIGHT
5000 - 6000
VARIES, 4000 (MAX)

PRECAST RETAINING
WALL PANEL GRADE S40

APPROXIMATE WEIGHT FOR 2m = 40.2 TONNE


WIDE PRECAST PANEL
REINFORCEMENT RATE = 220 kg/m3

500x500 CHAMFER INSITU STITCH POUR FOR


PRECAST WALLS
FINISH GROUND U-BAR
LEVEL
600
MIN.
500

50 BLINDING ON COMPACTED SOIL


2000 3750
PRECAST CAST IN SITU
5750
OVERALL

PRECAST RETAINING WALL PANEL RW6.0 1:20 (A1) / 1:40 (A3)


0 0.2m 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6 2.8 3
SCALE 1 : 20
REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
As indicated DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ RETAINING WALL CONCRETE DETAILS - SHEET 1
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00161
DATE 24.06.2022 PTA Drawing No: 04-S-72-0052 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
NOTES:
430
1. NO RETAINING WALLS REQUIRED BELOW H≤1000mm.
2. ALLOW FOR STABILITY BRACING OF THE RETAINING WALL
PRIOR TO BACKFILLING.
3. SEE PLAN AND ELEVATION DRAWINGS FOR NOISE WALL
LOCATIONS.
4. ONLY WALLS WHERE H>3000mm ARE TO WITHSTAND IMPACT
LOAD OF 500kN.
5. WEIGHT OF PRECAST WALL FOR HANDLING PURPOSES (DOES

1200
NOT INCLUDE IN-SITU CONCRETE)
430
2600 x 30

1838
ARCHITECTURAL ZONE TOP OF RAIL LEVEL

REFER GENERAL ARRANGEMENT PLAN AND ELEVATION


FOR LOCATIONS OF RETAINING WALL

638

1200
FORMATION LEVEL

2600 x 30

1838
ARCHITECTURAL ZONE TOP OF RAIL LEVEL

638
FORMATION LEVEL

1962
TOTAL PANEL HEIGHT

600
7350 (MAX)

TOTAL PANEL HEIGHT

1962
6280 (MAX)
RETAINING HEIGHT
4000 - 5000

RETAINING HEIGHT
500

3000 - 4000
PRECAST RETAINING
WALL PANEL GRADE S40
VARIES, 3000 (MAX)

APPROXIMATE WEIGHT FOR 2m = 33.1 TONNE


WIDE PRECAST PANEL PRECAST RETAINING
REINFORCEMENT RATE = 225 kg/m3 WALL PANEL GRADE S40 APPROXIMATE WEIGHT FOR 2m = 27.8 TONNE

VARIES, 2000 (MAX)


WIDE PRECAST PANEL
REINFORCEMENT RATE = 240 kg/m3

500x500 CHAMFER INSITU STITCH POUR FOR 500x500 CHAMFER


INSITU STITCH POUR FOR
PRECAST WALLS FINISH GROUND
FINISH GROUND PRECAST WALLS
LEVEL U-BAR
LEVEL U-BAR

MIN.
500

480
550
MIN.
500

50 BLINDING ON COMPACTED SOIL


50 BLINDING ON COMPACTED SOIL 2000 2000
2000 3000 PRECAST CAST IN SITU
PRECAST CAST IN SITU 4000
5000 OVERALL
OVERALL

PRECAST RETAINING WALL PANEL RW5.0 PRECAST RETAINING WALL PANEL RW4.0
SCALE 1 : 20 SCALE 1 : 20

1:20 (A1) / 1:40 (A3)


0 200mm 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
As indicated DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ RETAINING WALL CONCRETE DETAILS - SHEET 2
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00162
DATE 24.06.2022 PTA Drawing No: 04-S-72-0053 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
NOTES:
1. NO RETAINING WALLS REQUIRED BELOW H≤1000mm.
2. ALLOW FOR STABILITY BRACING OF THE RETAINING WALL
PRIOR TO BACKFILLING.
3. SEE PLAN AND ELEVATION DRAWINGS FOR NOISE WALL
LOCATIONS.
4. ONLY WALLS WHERE H>3000mm ARE TO WITHSTAND IMPACT
LOAD OF 500kN.
5. WEIGHT OF PRECAST WALL FOR HANDLING PURPOSES (DOES
380 NOT INCLUDE IN-SITU CONCRETE)

FORMATION LEVEL

250
REFER GENERAL ARRANGEMENT PLAN AND ELEVATION
FOR LOCATIONS OF RETAINING WALL
2600 x 30
ARCHITECTURAL ZONE
330
FORMATION LEVEL

250
TOTAL PANEL HEIGHT

RETAINING HEIGHT
2550 x 30

2000 - 3000
PRECAST RETAINING APPROXIMATE WEIGHT FOR 2m = 11.7 TONNE
3600 (MAX)

ARCHITECTURAL ZONE
WALL PANEL GRADE S40 WIDE PRECAST PANEL
REINFORCEMENT RATE = 200 kg/m3 PRECAST RETAINING

TOTAL PANEL HEIGHT

RETAINING HEIGHT
WALL PANEL GRADE S40

2000 (MAX)
2550 (MAX)
APPROXIMATE WEIGHT FOR 2m = 7.0 TONNE
WIDE PRECAST PANEL
REINFORCEMENT RATE = 200 kg/m3
500x500 CHAMFER FINISH GROUND
FINISH GROUND 500x500 CHAMFER
LEVEL
LEVEL

MIN.
500
MIN.
500

350
50 BLINDING ON COMPACTED SOIL
50 BLINDING ON COMPACTED SOIL
2000
2650 PRECAST
PRECAST

PRECAST RETAINING WALL PANEL RW3.0 PRECAST RETAINING WALL PANEL RW2.0
SCALE 1 : 20 SCALE 1 : 20

1:20 (A1) / 1:40 (A3)


0 200mm 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
As indicated DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ RETAINING WALL CONCRETE DETAILS - SHEET 3
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00163
DATE 24.06.2022 PTA Drawing No: 04-S-72-0054 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
PANEL PANEL PANEL

PRECAST SEGMENT
(TYP.) ARCHITECTURAL ZONE
(TYP.)

PRECAST CONCRETE
FOOTING (TYP.)

TOTAL PANEL HEIGHT


PRECAST L-WALL WITH
500x500 CHAMFER (TYP.)

IN-SITU BASE SLAB


(TYP.)

300x750 TIE SLAB AT 2000 c/c


2005 750
IN-SITU BASE SLAB
(TYP.) (TYP.) U-BAR (TYP.) (TYP.)

300x750 TIE SLAB AT


2000 c/c (TYP.)
PRECAST FOOTING 50 BLINDING ON COMPACTED SOIL
WIDTH

RETAINING WALL CONCEPTUAL USING PRECAST


L-SHAPED WALL
SCALE 1 : 50

TYPICAL PLAN - PRECAST RETAINING WALL


AND IN-SITU CONCRETE BASE
SCALE N.T.S

1:50 (A1) / 1:100 (A3)


0 0.5m 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
As indicated DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ RETAINING WALL CONCRETE DETAILS - SHEET 4
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00164
DATE 24.06.2022 PTA Drawing No: 04-S-72-0055 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
CL JOINT

40 DIA. GALV. SPIRAL GR S40 CONCRETE N24 REBAR 3N20 U-BAR (TYP.)
GROUT TUBE, INFILL WITH
GR S40 FLOWABLE GROUT 210 210
(TYP.)
A

100

150
0056

150

150
150

150
75
150 100
(TYP.)
B
0056

HALFEN LOOP
N28 REBAR

TYPICAL PRECAST RETAINING WALL


CONNECTION DETAIL AT TOP JOINT
SCALE 1 : 10

CL JOINT 40 DIA. GALV. SPIRAL


GROUT TUBE, INFILL WITH
800 GR S40 FLOWABLE GROUT
GR S40 CONCRETE
(TYP.)

160
225

140
120

130
70

N20 U-BAR
650 50 150 150 50
4N24 REBARS
20

JOINT DETAIL AT TOP OF RETAINING WALL (TYP.)

SECTION A
SCALE 1 : 10 0056

CL JOINT
30 ARCHITECTURAL
ZONE

N28 BAR
FRONT FACE 20 HALFEN HLB
GAP M-50/150

CL RETAINING WALL
200

HALFEN HLB MIX


BACK FACE
12x12 CHAMFER (TYP.) PRECAST RETAINING WALL
BACKING ROD AND
80
SEALANT, FULL LENGTH
(TYP.) INTERNAL DIMENSION

JOINT DETAIL IN VERTICAL FACE OF PRECAST RETAINING WALL (TYP.)

1:10 (A1) / 1:20 (A3)


SECTION B 0 100mm 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500
SCALE 1 : 10 0056
REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
1 : 10 DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ RETAINING WALL CONCRETE DETAILS - SHEET 5
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00165
DATE 24.06.2022 PTA Drawing No: 04-S-72-0056 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt
30mm ARCHITECTURAL CL POST
RECESS ZONE

CL POST CL POST CL POST CL POST


NOISE WALL PANEL
NOISE WALL
POST (TYP.)

NOISE WALL POST FRONT FACE OF


4390 NOM. (TYP.) FOOTING (TYP.)
PRECAST CONCRETE NOISE WALL NOISE WALL

2600 PANEL HEIGHT


PANEL PLACED ALTERNATIVELY
FRONT AND BACK (TYP.) NOISE WALL
POST (GLAV)
TRACK SIDE
TRACK SIDE CL RAIL

SECTION D 5000 (TYP.)


SCALE 1 : 50 0057

FINISHED GROUND
LEVEL

200
C
CL POST 4000 POST SPACING CL POST
0057
UNO NEOPRENE PAD (3mm THICK)
PANEL LENGTH PRECAST CONCRETE (TYP.)
NOISE WALL PANEL CL POST
CL POST

2000 (END 3 POSTS)


Ø600 GR N40, ALLOW FOR

1500 TYPICAL
3mm STEEL CASING
NOISE WALL POST
(TYP.)
PRECAST PANEL PRECAST PANEL PRECAST PANEL
DESIGN GROUND LEVEL
D
0057

PANEL STEP
PACKER
NOISE WALL POST
FOOTING (TYP.)

TYPICAL POST AND PANEL NOISE WALL ELEVATION SECTION C


1:50 SCALE 1 : 20 0057

3000 10000 GAP 3000


1100

TWO RAIL HANDRAIL,


REFER PTA STANDARD
DRG. No. 00-S-0001 (TYP.)
WALKWAY LEVEL

POST FOOTING
(TYP.)

TYPICAL HANDRAIL SETOUT ON EMBANKMENTS


1:25

REFERENCE DESIGN
VALIDATION REFERENCES SCALE DESIGNED VICTORIA PARK TO CANNING
M.SOOI
LEVEL CROSSING REMOVAL
As indicated DRAWN G.WIN
SIGNATURE
ZONE 0 - CIVIL STRUCTURES
CHECKED A.ISAAC
A01 24.06.22 ISSUED FOR 15% INTERNAL REFERENCE DESIGN MS GW AI WS DATUM PROJECT WIDE - ABUTMENTS & RETAINING WALLS
DATE APPROVED
REV DATE AMENDMENT DSN DRN CHK APP HORIZONTAL: PCG20 W.SCHWARZ RETAINING WALL CONCRETE DETAILS - SHEET 6
ORIG SIZE 0 10 20 30 40 50 100mm This document must not be copied without PTA's written DATE APPROVED
VERTICAL: AHD71
A1 AT ORIGINAL PLOT SIZE
permission, and the contents thereof must not be imparted
to a third party nor be used for any unauthorised purpose. Contractor No: LXR-PW-Z0-ST-RW-DWG-00166
DATE 24.06.2022 PTA Drawing No: 04-S-72-0057 Rev: A01
CAD DRAWING PATHNAME Autodesk Docs://AU-PS129931 - Inner Armadale Line Level Crossing - R22 - C22/LXR-PW-Z0-GN-ST-RW-M3D-00001.rvt

You might also like