Professional Documents
Culture Documents
Contents
1. Installation
1) How to set up in/output configuration according to number of doors. l4
2) Error occurs when installing SQL Database. l9
3) All the software have been installed, but error message appears and can’t log-in to the software. l 13
2. Management
1) Door does not open. l 16
2) Communication does not work. l 24
3) Response speed of Event has slowed. l 32
4) I would like to print T&A report, but I can’t find the report. l 33
5) I don’t know how to do a database backup. l 34
6) Can I recover a database backup file? l 37
7) How can I have a backup database automatically with arranged schedule? l 40
8) I have used the software for long time. The software has slowed down and “Database Insert Error”
message appears. l 47
3) All the software have been installed, but error message appears
Output Ports #1
iTDC Main Board
Door Lock for Door 1
Input Port #1,
Output for Reader #1
Input Ports #4
Door Contact for Door 2
Output to Output Port #4 Output Ports #2
Output Ports #3
Input Ports #2
Door Contact for Door 1 Door Lock for Door 2
Output to Output Port #2 Input Port #3,
Output for Reader #2
Input Ports #1
Exit Button for Door 1 Output Ports #4
Output to Output Port #1
Alarm for Door 2
Input Port #4,
Output for Reader #2
Output Ports #2
Output Ports #3
Input Ports #2 Door Lock for Door 2
Door Contact for Door 1 Input Port #3, Output for Reader #2
Output to Output Port #2
Output Ports #4
Input Ports #1
Exit Button for Door 1 Alarm for Door 2
Output to Output Port #1 Input Port #4, Output for Reader #2
① Did You Install SQL Server 2005 Express Edition as Indicated Below?
※ Following products must be installed to the computer prior to installing SQL Server 2005
Express Edition
ㆍMicrosoft .NET Framework 2.0
ㆍMS-XML6
ㆍCheck ” I accept the licensing terms ㆍClick Install ㆍInitial Installation Complete,
and conditions”, Click Next Click Next
ㆍBegin Installation of SQL Server, ㆍConfirm the SQL Server System ㆍInsert ”Name / Company “
Click Next Configuration Check, Click Next ㆍUn-check “Hide advanced configuration
options”, Click Next
ㆍSelect “Entire feature will be installed ㆍ Click Next ㆍSelect ”Default Instance”,
on local hard drive” for Database Service Click Next
and Client Components, Click Next
ㆍSelect ”Use the built-in System account” ㆍSelect ”Mixed Mode”, Insert Password, ㆍFor Collation, use the default setting
ㆍSelect ”Local System” Click Next or select the categories according to
ㆍCheck ”SQL Server 및 SQL Browser”, Click Next the language in use, Click Next
ㆍConfirm the Installation of all the ㆍClick Next when Installation is ㆍClick Finish
products Completed ㆍRestart the computer when the
Installation is completed
① After Installing the software, Did you Configure Database Server Definition?
: After installing the Database Server and iTDC PRO II S/W, you must configure Database Server
Definition as Below to Log-In to the software properly.
ㆍS/W screen for successful connection ㆍS/W screen for failed connection
4) I would like to print T&A report, but I can’t find the report.
8) I have used the software for long time. The software has slowed down
A4. Yes, events appear on the s/w. (Same as Answer ① & ② for Question A2)
A5. No, events do not appear on the s/w. (Same as Answer ③ & ④ for Question A2)
[Set up] >> [Set System Data] >> Use [Card Holders] to register ID information
[Access Control] >> Use [Card Holder Management] to register ID information
[Set up] >> [Set System Data] >> [Card Holders] [Access Control] >> [Card Holder Management]
The maximum distance of Wiegand cable between controller and reader is 150m, but it is
recommended to install the products within 30~40m for stable system operation.
※ Refer to the product manual for recommended cable and distance.
④ Are you using separate power source for reader and controller?
: When using separate power source for reader and controller, if the ground is not connected,
it may cause a potential difference between reader and controller and not transfer the data properly.
Connect ground wire when using separate power sources for reader and controller
FGR006
+12V ID40WA
GND
AC
+12V ID40WA
GND
AC
Ground
★ Bad fingerprint condition may cause timeout during fingerprint registration and may cause Fingerprint Error during identification.
★ When registering fingerprint using FGR006 or Hamster, the condition of the fingerprint can be checked on the software.
If the condition of the fingerprint is 3 or lower, it is recommended to use Verification (1:1) Mode.
Place your finger on the scanner when the RED LED lights up, and remove your finger when the
RED LED turns off.
: If the fingerprint is not identified properly, it may cause Fingerprint Error and the door will not open.
Refer to below information for proper way of registering and identifying fingerprint.
CORRECT INCORRECT
★ Bad fingerprint condition may cause timeout during fingerprint registration and may cause Fingerprint Error during identification.
INC400 ITDC
TX+
TX-
RX+
RX-
Baud Rate must be configured in same value as configured in the controller in same loop.
Please note that the Com Port may vary according to different PCs.
Baud Rate Out of the Port List, Select the Port Number
(i.e. COM1) for USB Serial Cable
FINGERPRINT
Controller Reader
Board ID Board ID
[System] >> [Controller Definition] [System] >> [Biometrics Reader Communication Definition]
※ PING TEST (Check if the network connection is stable, and check network respond speed.)
: START RUN ping +IP Address
※ IP Address
Insert the IP Address configured in TCP/IP Converter
Type : STATIC IP
ㆍSTATIC IP: Can only use STATIC IP for iTDC PRO S/W
ㆍ Consult with network specialist for configuring
IP Address, Gateway, Subnet Mask
ㆍClick the Refresh button to search all LAN Converter ㆍ IP Address : Can’t use same IP address within same network
ㆍInsert IP Address and Subnet Mask according to network ㆍBaud Rate: 9600 (iRecommended Comm. Speed for iTDC)
② Check if the Controller That Is Not Being Used is Configured in the Software
: If a controller that is not being used exists in the loop, the system uses polling method to request
communication, which could cause the communication to slow down.
You can increase the communication speed by deleting the controller that is not being used.
Daily Closing
Monthly Closing
Time & Attendance >> Daily Time & Attendance Data management
Annual Closing
Time & Attendance >> Monthly Time & Attendance Data management
Time & Attendance >> Annual Time & Attendance Data management
Step 3) Click [Add] button Step 5) Select location where you would like to store
the backed up database and type
file name.
Step 3) Type name of database you would like to restore. Step4) Click [Add] button
Select from device and Click [….] button.
Step 5) Select the file you have backed up Step 7) Click [Options] on the left & upper corner, select
and click [OK] button. the [Overwrite the existing database (WITH REPLACE)]
and click [OK] button.
This function is not supported when using Microsoft SQL Server 2005 Express Edition.
SQL Server Agent is needed for automatic maintenance function when using Microsoft SQL Server 2005
Step 1) Run Microsoft SQL 2005 Management Studio Step 1) On Object Explorer, Select Management and
log in with ID and Password. click right button >> Maintenance Plans Wizard.
Step 3) Click [Next] button Step 5) Set Maintenance plans according to automatic
maintenance plan.
Step4) After typing the name, click [change…]button Step6) Click [Next] button
for Schedule.
Step 7) Select what you will automatically manage. Step8) Place “Shrink Database” on the top and
*Shrink Database and Back up Database is usually “Back Up Database” as second.
checked for automatic management.
Click [Next] button.
Step 9) Choose “Select one or more” in Database Step 11) Click [Next] button
Step10) Select database you will manage and Step12) Choose “Select one or more” for database.
click [OK] button.
Step 13) Select database you will manage and Step14) Click [….] button in Folder category.
click [OK] button.
Step 15) Select folder you will stored backed up database Step16) Click [Next] button.
and click [OK] button.
① Delete Some of the Saved Data from the Database and Reduce the Log File.
: If the stored data exceeds the capacity of the database (over 70% of the total capacity) or large
information is stored in certain table, it may cause the software to slow down and search ability
speed to decrease. In this case, delete the data that is no longer needed and reduce the log file
to increase the software operation speed.
3. Technical Training
(Communication & System Integration)
1) Controller Overview
2) IN/OUT Configuration
3) System Configuration
4) Communication Cable
5) Controller Power Wiring
6) Initialization
7) FGR006 Reader Wiring
8) EXIT Button & Door Sensor Wiring
9) Door Lock Wiring
10) Board ID Setting for iTDC
11) Board ID Setting for FGR006
12) Communication Wiring
13) How to Install iTDC PRO S/W
2011 Jan IDTECK. © All rights reserved
4. Technical Training _Communication & System Integration (iTDC+FGR006+iTDC PRO II) 50
1) Controller Overview
Initialization Switch
Board ID Switch
Relay Output Port #1~4
RS232 Serial
LCD Connector
Communication Port
RS422 Serial
Communication Port
Keypad Connector
Power Port
1) Controller Overview
CPU
Event Memory
GAL IC
Program Memory
(Replaceable)
1) Controller Overview
1) Controller Overview
2) IN/OUTPUT Configuration
Input Ports #4
Door Lock for Door 1
Door Contact for Door 2
Output to Output Port #4
Output Ports #2
Output Ports #3
Input Ports #2 Door Lock for Door 2
Door Contact for Door 1
Output to Output Port #2
Output Ports #4
Input Ports #1
Exit Button for Door 1 Alarm for Door 2
Output to Output Port #1
2) IN/OUTPUT Configuration
2) IN/OUTPUT Configuration
2) IN/OUTPUT Configuration
Output Ports #2
Output Ports #3
Input Ports #2 Door Lock for Door 2
Door Contact for Door 1 Input Port #3, Output for Reader #2
Output to Output Port #2
Output Ports #4
Input Ports #1
Exit Button for Door 1 Alarm for Door 2
Output to Output Port #1 Input Port #4, Output for Reader #2
▶Configuration for Door 1 & 2 is done in a same way as configuring 1~2 door control.
2011 Jan IDTECK. © All rights reserved
58
4. Technical Training _Communication & System Integration (iTDC+FGR006+iTDC PRO II) 58
2) IN/OUTPUT Configuration
▶Configuration for Door 1 & 2 is done in a same way as configuring 1~2 door control.
2011 Jan IDTECK. © All rights reserved
4. Technical Training _Communication & System Integration (iTDC+FGR006+iTDC PRO II) 59
2) IN/OUTPUT Configuration
④ Software Configuration
ㆍThe basic configuration for Input /Output can be done in the management software.
3) System Configuration
① System Configuration
3) System Configuration
② Serial Communication
HOST DOOR A
iTDC
DOOR B
DOOR B
DOOR A
+12V ID40WA
+12V GND
AC
GND
ID40WA
3) System Configuration
③ TCP/IP Communication
Hub
TCP/IP Communication
HOST
iTDC
DOOR A
DOOR B
DOOR B
DOOR A
+12V ID40WA
+12V GND
AC
GND
ID40WA
4) Communication Cable
① Transmission Media
Transmission
media
Guided Unguided
(wired) (wireless)
4) Communication Cable
4) Communication Cable
③ Recommendation Cable
a. Data Cable : Applied for Card Reader (Wiegand), Controller (RS232, RS422, RS485, TCP/IP)
ㆍSTP : 24&22 AWG Twisted 2 Pair
ㆍFTP : 22 AWG Twisted 2 Pair
ㆍUPT : Category 5, Category 6
b. Signal & Control Cable (20&18 AWG) : Applied for Lock, Exit Button, PIR Sensor, Alarm
c. Power Cable (18AWG) : Applied for AC, DC
4) Communication Cable
④ Cable Distance
Maximum
No Description Recommendation Cable
Distance
iTDC/iTDC-SR Power (DC12V) Belden #9409, 18 AWG
① 3m
DC Power <--> iTDC 2 conductor, unshielded
System Configuration • The thicker wire is necessary if the user connects the reader
with high current consumption.
4) Communication Cable
⑤ Cable Grounding
• Definition
① To make an electric connection between electric devices and the ground
• Purpose
① To avoid lightening and static electricity
②To prevent Over flow of electricity or Over Voltage – Stable system operation
• Cable Grounding
① Ground Loop
4) Communication Cable
HUB
Shield
TCP/IP
Module
(IIM7100A)
① DC Power Output
Terminal
1 2
ㆍ1: DC +12V
ㆍ2: GND
⑤ Backup Battery
Connection Cable ② Power LED
12
ㆍRed : + Connector
ㆍBlack : - ㆍ1: +
ㆍ2: -
+12V
Back-up Battery(12V/7A)
2011 Jan IDTECK. © All rights reserved
4. Technical Training _Communication & System Integration (iTDC+FGR006+iTDC PRO II) 71
※ To activate the warning alarm, connect the signal to the input terminal
of the controller to notify the AC power cut off or low battery.
Input
1234
Terminal
Input
Terminal
ㆍ#1, #2 : Connect the signal to the input terminal of the controller to notify the AC power cut off
ㆍ#3, #4 : Connect the signal to the input terminal of contact of the controller to notify low battery
6) Initialization
PRESS
Initialize END
System Restart…
6) Initialization
※ Initialization of All Data from iTDC or Initialization of Only Certain Data from iTDC
: System Initialization, Card Data Initialization, Event Data Initialization, Time Schedule Initialization
FGR006
Diode
Diode
Diode
Diode
※ Board ID Configuration
Board ID is a distinctive address assigned to each unit.
Overlapping board IDs within a single communication loop will cause communication error.
1 1
1 2 3 4 5 6 7 8
0 1 2 3 4 5 6 7 8
0
1 1
2 2
4 4
8 8
16 16
32 32
64 64
128 128
ADDRESS VALUE Board ID : 1+2+16 = 19
ON 1
0
1 2 3 4 5 6 7 8
1
2
4
8
16
32
64
128
ADDRESS VALUE
R-
T-
HOST PC
CONVERTER
Max. 1200m
TX- (Yellow)
TX+ (Gray)
RX+ (Brown)
RX+
TX+
RX-
TX-
RX- (Blue)
iTDC #1
Board ID: 000 Connect iTDC #1 & iTDC #2
Cross Connection
RX+ <-> TX+
RX- <-> TX-
TX+ <-> RX+
TX- <-> RX-
2011 Jan IDTECK. © All rights reserved
4. Technical Training _Communication & System Integration (iTDC+FGR006+iTDC PRO II) 83
ㆍCheck ” I accept the licensing terms ㆍClick Install ㆍInitial Installation Complete,
and conditions”, Click Next Click Next
ㆍBegin Installation of SQL Server, ㆍConfirm the SQL Server System ㆍInsert ”Name / Company “
Click Next Configuration Check, Click Next ㆍUn-check “Hide advanced configuration
options” , Click Next
ㆍSelect “Entire feature will be installed ㆍ Click Next ㆍSelect ”Default Instance”,
on local hard drive” for Database Service Click Next
and Client Components, Click Next
ㆍSelect ”Use the built-in System account” ㆍSelect ”Mixed Mode”, Insert Password, ㆍFor Collation, use the default setting
ㆍSelect ”Local System” Click Next or select the categories according to
ㆍCheck ”SQL Server & SQL Browser”, the language in use, Click Next
Click Next
ㆍSelect ”Enable User Interface”, Click Next ㆍClick Next ㆍClick Install
2011 Jan IDTECK. © All rights reserved
4. Technical Training _Communication & System Integration (iTDC+FGR006+iTDC PRO II) 86
ㆍConfirm the Installation of all the ㆍClick Next when Installation is ㆍClick Finish
products Completed ㆍRestart the computer when the
Installation is completed
※ START Microsoft SQL Server 2005 Configuration Tools “SQL Server Surface Area Configuration”
ㆍSelect ”Surface Area Configuration for ㆍSelect ”Database Engine” ㆍSelect ”Database Engine”
Service and Connections” ㆍSelect ”Remote Connection” ㆍSelect ”Service”
ㆍSelect ”Using both TCP/IP and names pipes” ㆍClick ”Stop” to stop the SQL Server
ㆍClick ”Apply” ㆍWhen the SQL Server is stopped,
Click “Start” to restart the Server
ㆍDatabase Connection Configuration ㆍStarts generating a new database ㆍClick “Finish” to end the installation
ㆍInsert Server Name / IP Address ㆍClick “Connection Test” to check the ㆍS/W screen for successful connection
: If the iTDC PRO II and Database are connection status
installed on the same location,
insert “localhost”
ㆍS/W screen for failed connection 2011 Jan IDTECK. © All rights reserved
4. Technical Training _Communication & System Integration (iTDC+FGR006+iTDC PRO II) 91
a. Loop Definition
b. Controller Definition
d. Door/Reader Definition