You are on page 1of 34

MAH

HARAS
SHTRAA STAT
TE BOA
ARD OF
F
TECH
HNICAL
L EDUCCATIO
ON,
MUUMBAII

MS
SBTE NOR
RMS AND D STA
ANDA
ARDS
S
OR EQ
FO QUIP PMEN NTS AND
A D
MA
ACH HINER RIES
(20122-201
13)

N
NAME O
OF THE COU
URSE / COURS
C SE GRO
OUP

ME
EDICA
AL ELEC
E CTRO
ONICS
S
(M
MU)

(AIC
CTE Approved Coursee)

1
MSBTE NORMS AND STANDARDS FOR EQUIPMENTS AND
MACHINERIES(2012-2013)
MEDICAL ELECTRONICS (MU)
LABWISE SUBJECT DISTRIBUTION

SR.NO. NAME OF LAB SUBJECT


1 ANALOG ELECTRONIC LAB Elements of Electronics MU2G
Electronics Devices & circuit MU3G
Linear Integrated Circuits MU4G
2 DIGITAL & MICROCONTROLLER LAB Principal Of Digital Techniques MU3G
Microcontroller MU5G
Embedded Systems MU6G
3 COMMUNICATION LAB Communication Techniques MU5G
4 MESURMENT LAB Electronics Measurement & Instruments MU3G
Biosensor MU4G
5 COMPUTER CENTER & HARWARE Computer fundamental- MU1G
LAB Programming In “C” MU3G
Visual Basics MU4G
Simulation Software MU5G
Computer Hardware & Networking MU5G
6 ELECTRONICS WORKSHOP Basic Workshop MU1G
Electronic workshop MU2G
Industrial PROJECT MU6G
7 HUMAN BIOLOGY & MEDICAL Human Biology MU4G
EQUIPMENT LAB Intensive care equipments MU6G
Medical Imaging Equipment MU6G
Therapeutic Equipment MU6G
Analytical Equipment MU5G
Diagnostic Equipment MU5G

2
INDEX
Sr.No. Title of Laboratory PageNo.
ANALOG ELECTRONIC LAB
1
DIGITAL & MICROCONTROLLER LAB
2
COMMUNICATION LAB
3
MESUREMENT LAB
4

COMPUTER CENTER & HARWARE LAB


5

ELECTRONICS WORKSHOP
6

HUMAN BIOLOGY & MEDICAL ELECTRONICS LAB


7

3
MSBTE NORMS AND STANDARDS FOR EQUIPMENT LIST OF
EQUIPMENT & MACHINERY
(Essential equipment/ Hand Tools) (Required for conducting the Practical)
1. Name of course/ Department:- Medical Electronics Dept.
2. Name of Laboratory: ANALOG ELECTRONIC LAB
3. Name of Subjects: Elements of Electronics MU2G
Electronics Devices & circuit MU3G
Linear Integrated Circuits MU4G

MinQtty
Sr. Name of Technical Specifications
No. Equipt./Machinery ./Nos.
Remark if any
1 Analog multimeter Suitable to measure AC/DC voltage , Current and Resistance Essential
DC voltage Range 400mV to 1000 V
AC Voltage Range 4V to 750 V 05
DC current 4 mA to 10A
AC current 4 mA to 10 A Resistance 400 Ohm to 40 Mohm
or any other better specifications and facilities
2 Digital multimeter 3.5 digit with R , V, I measurements, diode and BJT testing Essential

10
3 CRO Dual Channel, 4 Trace CRT / TFT based Essential
Bandwidth 20 MHz/30 Mhz Any other
X10 magnification 20 nS max sweep rate, Alternate triggering 10 Oscilloscope with
Component tester and with optional features such as Digital additional features
Read out , USB interface are also suitable
4 LCR Q Meter Parameter L-Q, C-D, R-Q and Z-Q Essential
Frequency 00 Hz, 120 Hz and 1 KHz
Accuracy Basic Accuracy : 0.3% 02
Display 5 digits display for both primary and secondary
parameters
L 100 Hz, 120 Hz 1 mH - 9999 H
1 KHz 0.1 mH - 999.9 H
Measurement C 100 Hz, 120Hz 1 pF - 9999 mF Range 1 KHz
0.1 pF - 999.9 mF
R, |Z| 0.0001V- 999.9 MV
D, Q 0.0001 – 9999
D% 0.0001% - 9999%
Test Level 120 Hz 0.3 Vrms (1 ±15%)
(Range Auto 1 KHz
and Open 100 Hz 0.42 Vrms (1±15%)
Circuit) Ranging Mod Auto and Hold
Equivalent Parallel and Series
Circuit Display Direct, DABS and D%
Correction Open and Short Zeroing
Terminals 5 terminals
Comparator 4 Bins : NG, P1, P2 and P3
D% -9999% - 99999%
4
L 0.0001 mH - 99999H
Limit Setup Nominal C 0.0001 pF - 99999 mF Range R
0.0001 V- 99999 MV
Z 0.0001 V- 99999 MV
Alarm Mode NG, P1, P2, P3 and OFF
Power Supply 9V battery or DC12V (100mA) adapter
5 Analog and Digital IC Suitable to test up to 40 pin IC analog and digital type Hunt Essential and can
tester mode facility be shared with
02 Analog
electronics lab
and digital
electronics lab.
6 Function Generator 1 MHz , sine, square, triangular, ramp and pulse generator Essential
Freq range 0.01 Hz to 1 Mhz, Output amplitude 20V open
circuited, Output impedance 50 ohms. Facility to indicate 06
output frequency & amplitude on dispay.
7 Lux meter Digital read out lux meter with output in LUX / Lumen unit 3 Essential
½ digit, hand held battery operated, having range of 0 to
50000 01
8 Bread Board Bread Board system with DC power output 5V, +/-12V & 0- Essential
Development 5V variable , digital voltmeter , ammeter , LED indicators 8 no
System , logic input switches 8 no, 7 segment display 2 no, clock 02
generator, Manual pulser, Breadboard with about 1,600 points,
Potentiometer, relay etc
9 Regulated power 0- 30 Volt, 2 A with digital display, with S.C. protection Essential
supply
06
10 Dual regulated power 0 to 30 V 2A/3 A dual DC regulated power supply with SC Essential
supply protection digital output meters for current and Voltage
06
11 Dual tracking power Dual tracking DC output 0 to 30 V and 2A /3 A current Essential
supply rating Digital output meters S C protection
06
*12 LDR trainer Kit Trainer kit to demonstrate principle of LDR and suitable to Essential
plot light intensity and Change in resistance characteristics
Along with kit Suitable Light source. LDR should be housed 01
in closed cabinet so that there is no effect of ambient light.

*13 Photo Diode Trainer Trainer kit to demonstrate principle of Photo Diode and Essential
kit suitable to plot light intensity and Change in resistance or
change in current characteristics Along with kit Suitable 01
Light source
*14 Trainer kit for HWR , Trainer kit shall consists of Following parts provided on PCB Essential
FWR without and with with connecting terminals & test points. Mains transformer
Capacitor and Inductor primary 230V A.C. Secondary centre tap 12-0-12VAC at 500 01
Filter mA. 4 diodes which can be interconnected by patch cords to
make HWR, FWR circuit, Filter Choke coil, filter Capacitors,
Load Resistors. Required configuration of rectifier and filter
can be assembled by patch cords. Waveforms can be observed
on CRO & various measurements can be done.
Line & load regulation can be found out.

5
*1 Trainer kit to verify Trainer kit to demonstrate superposition theorem with DC Essential
5 superstition theorem supply and test points
01
16 Trainer kit to verify Trainer kit to demonstrate Thevinin theorem with DC supply Essential
Thevinin theorem and test points
01
17 Trainer kit for CE Trainer kir suitable to plot I/p , O/P characteristic of NPN BJT Essential
configuration BJT in CE configuration with inbuilt DC supply and required
digital meters (4 No.) and various Test points 02
18 Trainer kit for JFET Trainer kir suitable to plot I/p , O/P characteristic of N Ch or P Essential
ch FET with inbuilt DC supply and required digital meters
(4 No.) and various Test point 02
19 Trainer kit for Trainer kir suitable to plot I/p , O/P characteristic of MOSFET Essential
MOSFET with inbuilt DC supply and required digital meters (4 No.)
and various Test point 02
20 Trainer kit for UJT Trainer kir suitable to plot V I characteristic of UJT with Essential
inbuilt DC supply and required digital meters (2 No.) and
various Test point 02
21 Trainer kit for single Trainer kit suitable to plot Frequency response of 2 stage Essential
stage and Multistage common emitter transistor amplifier circuit. Facility to meaure
BJT amplifier A1& A1xA2. Inbuilt DC supply and various Test points. 02
22 Trainer kit for single Trainer kit suitable to plot the frequency response of an Essential
tuned amplifier Transistorized L-C tuned (single) circuit amplifier. Centre
frequency above 400 Khz.( any other suitable frequency) 02
Inbuilt DC supply and various Test points.
23 Trainer kit for i) Trainer kit suitable to plot frequency response with & Essential
negative feedback without Voltage series feedback. Effect on gain and bandwidth
amplifier should be studied. Inbuilt DC supply and various Test points. 02
ii) Trainer kit suitable to plot frequency response with & each
without Voltage shunt feedback. Effect on gain and bandwidth
should be studied. Inbuilt DC supply and various Test points
iii) Trainer kit suitable to plot frequency response with &
without Current series feedback. Effect on gain and bandwidth
should be studied. Inbuilt DC supply and various Test points.
iv) Trainer kit suitable to plot frequency response with &
without Current shunt feedback. Effect on gain and bandwidth
should be studied. Inbuilt DC supply and various Test points.
24 Trainer kit for miller Transistorized circuit with facility to vary sweep rate. Inbuilt Essential
sweep generator DC supply and various Test points.
02
25 Trainer kit for BJT Trainer kit suitable to study the principle of transistorized Essential
series voltage series voltage regulator used in regulated power supplies.
regulator Measure the line & load regulation. Inbuilt unregulated DC 02
input & various test points.
26 Trainer kit for IC 723 Trainer kit suitable to study how the IC 723 can be used as Essential
voltage regulator variable voltage regulator in low/high mode. Measure the line
and load regulation. Inbuilt unregulated DC input & various 02
test points.
27 Trainer board for OP Trainer kit suitable to demonstrate the working of OPAMP Essential
AMP applications 741 in various modes like inverting amplifier, non-inverting
amplifier, adder, subtractor, integrator, differentiator etc. 02
Required R & C components are provided in trainer which can
6
be interconnected by patch cords to make the desired
configuration. 2 no variable DC regulated power supplies,
inbuilt offset adjust facility. Inbuilt DC regulated power
supply.
OR In dependent kits for various applications
28 Trainer board for IC ASTABLE, MONOSTABLE MULTIVIBRATOR USING IC Essential
555 multibirator 555.
Trainer consists of IC 555 and various components to built 02
circuit of Astable, Monostable multivibrator. Required R & C
components shall be available on trainer which can be
interconnected by patch cords to make the desired
configuration. Frequency can be varied. Inbuilt DC regulated
power supply.
29 Display board for Display board shall consists of various types of resistors with Essential
resistors proper label Covered with Glass / Transparent acrylic cover
Wall mount facility with locking facility 01
30 Display board for Display board shall consists of various types of inductors with Essential
Inductors proper label Covered with Glass / Transparent acrylic cover
Wall mount facility with locking facility 01
31 Display Board for Display board shall consists of various types of capacitors Essential
Capacitors resistors with proper label Covered with Glass / Transparent
acrylic cover Wall mount facility with locking facility 01
32 Display Board for Display board shall consists of various types of cables with 01 Essential
Cables proper label Covered with Glass / Transparent acrylic cover
Wall mount facility with locking facility
33 Display Board for Display board shall consists of various types of connectors 01 Essential
Connectors with proper label Covered with Glass / Transparent acrylic
cover Wall mount facility with locking facility
34 Display board for Display board shall consists of various types of switches and 01 Essential
switches and relay relay with proper label Covered with Glass / Transparent
acrylic cover Wall mount facility with locking facility
Note 1 : Laboratory shall have discrete components of various ratings -- such as resistors, capacitors , inductors , diodes, BJT, FET , LED ,
Photodiode, IC 741, IC 555, seven segment display, switches , transformers , breadboard and cables Components shall store in stack
component organizer.
Note 2 GENERAL SPECIFICATIONS FOR KITS.:-All the circuit components should be soldered on specially made PCB with facility for
connectors for easy servicing. Circuit components should be visible to students from transparent back panel. Every kit should be provided with
sample set of readings taken By Manufacturer for reference purpose which will ensure the proper performance of kit in future
Note 3 Trainer kit of sr. no shown with star mark shall be used only for demonstration These expt. Shall be perform on bread board.
.

MSBTE NORMS AND STANDARDS FOR EQUIPMENT


LIST OF EQUIPMENT & MACHINERY
(Essential equipment/ Hand Tools) (Required for conducting the Practical)
1. Name of course/ Department:- Medical Electronics Dept.
2.Name of laboratory : DIGITAL & MICROCONTROLLER LAB
3. Name of subjects : Principal Of Digital Techniques MU3G
Microcontroller MU5G
Embedded Systems MU6G
MinQtty./N
Sr. No. Name of Technical Specifications
Equipt./Machinery os.
7
Rem
ark if
any
1 Computer Systems Intel processor core i3 or i7 or latest with 10 Essenti
mother board Intel chipset 41/61/latest with 4 al
USB,1 serial port, 1 LPT port,2GB RAM DDR
III,500 GB Sata Hard disk, 16” or 18.5”
LCD/LED monitor, ATX cabinet with SMPS
and lock system, DVD writer, Keyboard, USB
mouse,1 Gigabit Network card/ latest
configurationLatest configuration

2 LCD / Data projector SVGA/XGA 800x600 Lamp Life Span 01 Essenti


(2000-2500 Hrs) 1200 /1500 Lumen (Min) al
with Screen and stand or Latest with better
lumens andadditional facility
3 Printer A4 Size laser printer 30 PPM 16 MB 01 Essenti
RAM 1200 DPI or latest al

4 Digital multimeter 3.5 digit with R , V, I measurements, 06 Essenti


diode and BJT testing al

5 CRO Dual Channel, 4 Trace CRT / TFT 08 Essenti


based Bandwidth 20 MHz/30 Mhz al
X10 magnification 20 nS max sweep Any
rate, Alternate triggering Component other
tester and with optional features such Oscillos
as Digital Read out , USB interface cope
with
addition
al
features
are also
suitable
6 Pulse Generator TTL pulse generator with variable 0 Essenti
frequency and duty cycle 4 al

7 IC tester Tests a wide range of Analog and Digital 0 Essenti


IC's such as 74 Series, 40/45 Series of 1 al
CMOS IC’s It can test Microprocessor
8085, 8086, Z80, 8051, 89c51 It tests
Peripherals like 8255, 8279, 8253,
8259, 8251, 8155,
8
6264,62256,8288,8284 t tests
Opamp,555, Transistor Arrays, Analog
switches, Opto
couplers and Others It tests 7 segment
display of common cathode & common
anode type IC testing 741 , 555 ,556 ,565
it has Auto search facility of IC’s
Test by: Truth table/sequence table
comparison ZIF: 40 pin DIP ZIF sockets
Keys: 28 cherry keys Key pad with
numerical & functional keys Display: 9
Digit Seven Segment Display Supply
Input Voltage: 230V ACAnalog, digital IC
testing 40 pins with hunt mode
8 Bread Board Bread Board system with DC power 0 Essenti
Development System output 5V, +/-12V & 0-5V variable , 6 al
digital voltmeter , ammeter , LED
indicators 8 no , logic input switches 8
no, 7 segment display 2 no, clock
generator, Manual pulser, Breadboard
with about 1,600 points, Potentiometer,
relay etc
9 Trainer kits for digital ICs Trainer kit shall consists of digital ICs for 02 Essenti
logic gates, flop flop, shift registers, al
counter along with toggle switches for
inputs and bi-colour LED at outputs, built
in power supply

10 Regulated power supply Floating DC Supply Voltages Dual DC 0 Essenti


: 2 x 0 - 30V; 0-2 A Automatic 2 al
Overload (Current Protection) Constant
Voltage & Constant Current Operation
Digital Display for Voltage and
Current Adjustable Current Limiter
Excellent Line & Load Regulation
DC Output : 2 × 0 - 30 V, 2 A
continuously Variable by means of
coarse and fine control s Current limit
: 100 mA - 2 A Continuously
adjustable 0 - 30 V Resolution :Voltage
: 10 mV Current : 5 mA Stability :
2.5 mV at 30 V / 2A Recovery Time :
<=50 μs
9
Load Regulation : <=(0.05 % + 10
mV)
Line Regulation : <=(0.05% +10mV)
Display : 3 digit for voltage & 3 digit
for current LED indication for Voltage
& Current
11 Trainer kit for ADC IC 8 bit output indicated on LED. Trainer 0 Essenti
0808/ ADC 0809 based on IC ADC0808. Built in analog 1 al
input varied by 10 turn potentiometer.
Built in DC power supply.
12 Trainer kit IC DAC IC Trainer based on IC 0800. 8 bit digital 0 Essenti
0800 input selected by switches & provision 1 al
for measurement of analog output.
Facility to study effect of change in
Reference voltage. Built in buffer
amplifier. Built in DC power supply
13 Trainer kit for 4 bit Counter 4 bit ripple counter SYNCHRONOUS 0 Essenti
using Flip Flops COUNTER. 1 al
IC 7476 based circuit. Input given by
switches and output indicated on LED.
Facility to select MOD 8 or MOD 16
mode. Built in DC power supply and
manual pulser with indicator.
14 Microcontroller Trainer Intel 89C51 Operating at 12 MHz. Essenti
kits( IC 8051 Based ) On board Crystal : 12 Mhz for al
Oscillator 1 & 1.8432 Mhz for
Oscillator 2.
On board GM 16C550 for
Asynchronous Serial Communication.
32 KB Onboard User Program
Memory.
12 KB Battery Backed Up User
program Memory.
16 KB Battery Backed Up User Data
Memory.
40 Characters X 2 Lines LCD Display
controlled by 89c2051.
Supports External ASCII Keyboard.
On board +5, +12, -12 V DC for
peripheral Card.
Timer Counter Chip (8253), 2 counters
10
available for User.
Two 8255 chips, Giving 48 TTL I/O
Lines. All Signals terminated on two
26 Pin FRC Connectors.
Port P1 pins brought out on 10 pin
connector for user interface.
Serial Port : RS-232 Compatible serial
port using 8250, signals terminated on
a 9-pin D type connector.
Address, data & control bus available
out on 50 pin FRC connector for
expansion.
Support following Modes Of Operation
i)Interrogation Mode : For interactive
dialog with system
ii)Assembler Mode : Line Assembler
inbuilt in monitor.
iii)Single Step Mode: Useful for Single
Stepping, inserting / removing
breakpoints and debugging.
Powerful Monitor Software with
standard commands like move, fill,
display/ modify registers, execute
Program, upload / download etc. Single
line assembler / disassembler.
Software LCD routines in EPROM :
Clear Screen, Row Column, Display
Character, Read Column, Read Row,
Display A Message, Cursor Off,
Cursor On, Read keyboard, Read
Keyboard & Display, Read Keyboard
Status, Read String & Display,
Keyboard Flush.
Kit should be housed in sturdy metallic
box with a transparent glass on top to
see the circuit.
15 Microcontroller simulation suitable simulation software to 1 Essenti
software perform microcontroller system al
programming
16 C compiler Suitable for microcontroller 1 Essenti
Programming
11
al

17 Embedded System trainer CPU: NXP- 89V51RD2 with crystal 1 Essenti


11.0592MHz. 0 al
On-Chip Internal Memory.
-64K Internal Flash Memory.
-1K Internal Data Memory.
Supports 12-clock (default) or 6-clock
mode selection via software or ISP.
Four interrupt priority levels.
Two switches are provided for
simulation of external interrupts(INT0
INT1).
All microcontroller Port lines are
connected to the IDC10 connectors for
further expansion.
Three 8-bit I/O ports available at IDC
26 connector for connecting extra
interfacing DYNA- PIO card.
On-Board ISP (in system
Programming) facility using Flash
protocol.
Windows Based ISP Programming
Software.
Compilers (Keil/MikroC).
18 Any one HDL software Suitable for basic VLSI programming 1 Essenti
al

19 FPGA trainer ADC , DAC and Steeper motor interface,VLSI 0 Essenti


development platform which will support 6 al
XILINXspartan2,board should consists of50K (quantit
gates,1728 logic cells,I/O ports 136,number of
y
pins 208,40 pin, 4 header connecter, Xilinx or
depends
any other equivalent software or system
on no.
of
students
obtaine
d the
subject)
20 UPS System 6 KVA Online, 6 Hrs. Backup 0 Desirab
2 le

12
ANNEXURE - I
MSBTE NORMS AND STANDARDS FOR EQUIPMENT
LIST OF EQUIPMENTS & MACHINERY
(Essential equipment/ Hand Tools) (Required for conducting the Practical)

1. Name of course/ Department:- Medical Electronics Dept.


2. Name of laboratory: COMMUNICATION LAB
3 Name of Subjects: Communication Techniques MU4G

Minimum
Sr No Name of the Equipment Technical Specification Remark
Quantity
1 Cathode Ray Dual Channel, 4 Trace 8 Essential
Oscilloscope CRT / TFT based Any other
Bandwidth 20 MHz/30 Oscilloscope
Mhz with
X10 magnification 20 additional
nS max sweep rate, features are
Alternate triggering also suitable
Component tester and
with optional features
such as Digital Read out
, USB interface
2 DSO Bandwidth : 50/100MHz TFT 1 Desirable
Colour LCD Dual Channel
Real Time Sampling: 1GSa/s
Equivalent Sampling 25GSa/s
Memory 1M pts 10 Waveforms
& 10 Setups can be stored
Autoset Function s 20 Auto
Measurement of Vpp, Vmax,
Vmin, Vtop, Vbase, Vamp,
Vavg, Vrms, Overshoot
Preshoot, Frequency,
Risetime, Falltime, Delay 1 -2,
Delay 1 -2, +Width, -Width,
+Duty, -Duty Mathematical
Functions : Add, Subtract,
Multiply & FFT Adjustable
Digital Filters (HPF, LPF, BPF
& BRF)
Cursor Measure : Auto, Manual,
Track Single shot triggering
mode Built-in FFT& USB
Interface Ultra scope: PC
control & Analysis Software
Interpolation sinx/x
Acquisition Modes : Normal,
Average, Peak detect or any
other better specifications
3 Digital Multimeter Min. 3 &1/2 Digitt with R , 6 Essential

13
V, I measurements, diode
and BJT testing
4 Power Supply 30V ,2A 4 Essential

5 Function Generator Frequency range 0.02Hz to 4 Essential


2MHz,20Vpp

6 PAM trainer kit i) PULSE 2 Essential


AMPLITUDE Can be shared
MODULATION. with other lab
Trainer kit suitable to
demonstrates the
principle of PAM using
OPAMP IC based
circuit with facility to
vary depth of
modulation. Inbuilt DC
supply and various
Test points.

ii)PULSE
AMPLITUDE
DEMODULATION.
Trainer kit suitable to
demonstrates the
principle of pulse
amplitude demodulation.
IC based circuit. This
unit should be matched
with PAM trainer &
original modulating
signal should be
obtained at output.
Inbuilt DC supply and
various Test points.
7 PWM trainer kit i) PULSE WIDTH 2 Essential
MODULATION. Can be shared
Trainer kit suitable to with other lab
demonstrates the
principle of PWM using
OPAMP IC based
circuit. Effect of change
in carrier and
modulating signal
amplitude & frequency
should be studied.
14
Facility to measure
pulse width under
steady input should be
provided. Inbuilt DC
supply and various
Test points.

ii) PULSE WIDTH


DEMODULATION.
Trainer kit suitable to
demonstrates the
principle of pulse width
demodulation using IC
based circuit. This unit
should be matched with
PWM trainer & original
modulating signal
should be obtained at
output. Inbuilt DC
supply and various
Test points
8 ASK,FSK,PSK trainer 4Study of Data Formats 2 Essential
kit 4Study of Amplitude Can be shared
Shift Keying 4Study of with other lab
Frequency Shift Keying
4Study of Phase Shift
Keying 4Study of
Differential Phase Shift
Keying 4Study of
Quadrature Phase Shift
Keying
Study of Differential
Quadrature Phase Shift
Keying
Technical Specifications
Carrier Demodulation
and
Data Reformatting
Receiver
Input : From Scientech
2156
Carrier Demodulation :
ASK - Rectifier Diode
FSK Detector
PSK / DPSK- Square
15
Loop Detector
QPSK - Fourth Power
Loop
Detector
Biphase Clock
Recovery : By PLL
Power Consumption : 6
VA (approximately)
Test Points : 39 (Gold
plated)
Interconnections : 2 mm
Sockets
Power Supply : 220/110
V, 50/60 Hz
9 PCM trainer kit i) STUDY OF 2 Essential
SAMPLING Can be shared
THEOREM. with other lab
Trainer kit suitable to
demonstrates the
principle of Sampling
theorem which is basic
of digital
communication system
by IC based circuit. Kit
should have built in
Clock generator, Pulse
generator Sample &
Hold circuit,
Microphone
Preamplifier & Filter
circuit. Also provided
with signal recovery
section. Effect of
aliasing should be
demonstrated. Inbuilt
DC supply and various
Test points.

ii) PULSE CODE


MODULATION.
Trainer kit suitable to
demonstrates the
principle of pulse code
modulation. Kit should
consist of Crystal based
16
clock generator, Divider
circuit, A to D converter
& parallel to serial
converter. Trainer
should give the pulse
code modulated signal
at output. Inbuilt DC
supply and various Test
points. Use of Storage
CRO is recommended
for observing PCM
signal.

iii) PULSE CODE


DEMODULATION.
Trainer kit suitable to
demonstrates the
principle of pulse code
demodulation using IC
based circuit. Kit
consists of serial to
parallel converter, D to
A converter, filter and
amplifier. This unit
should be matched with
PCM trainer & original
modulating signal
should be obtained at
output. Inbuilt DC
supply and various Test
points.
10 PPM trainer kit Onboard DPCM 2 Essential
Transmitter and receiver Can be shared
Onboard Signal with other lab
generator block
Onboard Audio input &
output processing
circuits
Clock and entire control
Signal section
Detailed signal
processing circuit with
complete data and
control signal flow
Signal generator block
17
Functions :
Sine and Square
O/P frequency range:
300Hz to 3.4
KHz
Audio blocks:Audio I/P
and O/P processing
circuits
Control signals
:R/W for ADC,
reset. Latch enables,
OEs.
Sampling frequency :
8 KHz
Total Bits per sample :5
bits including sign bit
Bandwidth
improvement
Compared to 8 bit PCM
:3 bits per
sample
69 Single Channel i) PULSE POSITION 1 Essential
Telemetry System MODULATION. Can be shared
Trainer Kit Trainer kit suitable to with other lab
demonstrates the
principle of pulse
position modulation
(PPM) using IC based
circuit. Facility to
measure output under
steady input should be
provided. Inbuilt DC
supply and various Test
points.
ii) PULSE POSITION
DEMODULATION.
Trainer kit suitable to
demonstrate the
principle of pulse
position demodulation.
IC based circuit. This
unit should be matched
with PPM trainer &
original modulating
signal should be
18
obtained at output.
Inbuilt DC supply and
various Test points.
7 Trainer kit for FM AC Source : 600Hz to 01 Essential
modulator using IC 566 2.5 KHz.
FM Modulator : VCO Can be shared
Low Pass Filter : with other lab
Butterworth Fourth
Order
Test Points
8 Trainer kit for FM AC Source : 600Hz to 01 Essential
demodulator using IC 2.5 KHz. Can be shared
564 FM Demodulator : PLL with other lab
Low Pass Filter :
Butterworth Fourth
Order
Test Points
71 Emitter / Base / Collector Kit to demonstrate 2 Essential
ModulationTrainer Kit modulation

ANNEXURE - I
MSBTE NORMS AND STANDARDS FOR EQUIPMENT
LIST OF EQUIPMENTS & MACHINERY
(Essential equipment/ Hand Tools) (Required for conducting the Practical)

1. Name of course/ Department:- Medical Electronics Dept.


2. Name of laboratory: MEASUREMENT LAB
3 Name of Subjects: Biosensor MU4G
Electronics Measurement & Instruments MU3G

Name of the Minimum


Sr No Technical Specification Remark
Equipment Quantity
1 Digital Multimeter 4.5 digit with R , V, I Essential
measurements, diode and
BJT testing 6
2 CRO Dual Channel, 4 Trace 08 Essential
CRT / TFT based Any other
19
Bandwidth 20 MHz/30 Oscilloscope
Mhz with additional
X10 magnification 20 features are
nS max sweep rate, also suitable
Alternate triggering
Component tester and
with optional features
such as Digital Read
out , USB interface
3 DSO Bandwidth : 50/100MHz TFT Essential
Colour LCD Dual Channel
Real Time Sampling: 1GSa/s
Equivalent Sampling 25GSa/s 02
Memory 1M pts 10 Waveforms
& 10 Setups can be stored
Autoset Function s 20 Auto
Measurement of Vpp, Vmax,
Vmin, Vtop, Vbase, Vamp,
Vavg, Vrms, Overshoot
Preshoot, Frequency,
Risetime, Falltime, Delay 1 -2,
Delay 1 -2, +Width, -Width,
+Duty, -Duty Mathematical
Functions : Add, Subtract,
Multiply & FFT Adjustable
Digital Filters (HPF, LPF, BPF
& BRF)
Cursor Measure : Auto, Manual,
Track Single shot triggering
mode Built-in FFT& USB
Interface Ultra scope: PC
control & Analysis Software
Interpolation sinx/x
Acquisition Modes : Normal,
Average, Peak detect or any
other better specifications
4 RF signal Generator 100 MHz, sine wave Essential

02
5 Function Generator 3 MHz , sine, square, Essential
triangular and pulse
generator 06
6 Regulated Power Floating DC Supply Essential
Supply Voltages Dual DC : 2 x
0 - 30V; 0-2 A 04
Automatic Overload
(Current Protection)
Constant Voltage &
Constant Current
Operation Digital
Display for Voltage and
Current Adjustable
20
Current Limiter
Excellent Line & Load
Regulation
DC Output : 2 × 0 - 30
V, 2 A continuously
Variable by means of
coarse and fine control
s Current limit : 100
mA - 2 A Continuously
adjustable 0 - 30 V
Resolution :Voltage :
10 mV Current : 5 mA
Stability : 2.5 mV at 30
V / 2A Recovery Time
: <=50 μs
Load Regulation :
<=(0.05 % + 10 mV)
Line Regulation :
<=(0.05% +10mV)
Display : 3 digit for
voltage & 3 digit for
current LED indication
for Voltage & Current
7 CRO trainer set CRO trainer board with Essential
block tracing facility
various test points 01
8 AF signal generator 1Mhz with variable Essential
amplitude and
frequency 02
9 Digital frequency DFM with time Essential
meter measurement 1MHz
range 02
10 Strain Gauge set up STRAIN GAUGE 1 Essential
TRAINER WITH Can be shared
INSTRUMENTATION with other lab.
AND INDICATOR
Trainer kit consists of
Whetstone bridge,
Cantilever type loading
arrangement, on which
2 strain gauges are
mounted, Weights up to
2Kg, DC amplifier,
Digital indicator in
terms of gms. Facility
21
to select Quarter and
Half bridge mode.
Should be housed in
transparent acrylic
cover so that strain
gauges are visible to
students. Inbuilt DC
regulated Power supply
etc
11 Potentiometer kits - For linear Rheostat 5 Essential
Linear & Angular from 25 ohms to 50
ohms can be used
For Angular,
Potentiometer of
different values from
10K to 100K can be
used.
12 DMM trainer Trainer shall Essential
demonstrate working of
DMM 02
13 LCR Q meter Parameter L-Q, C-D, R- Essential
Q and Z-Q
Frequency 00 Hz, 120 01
Hz and 1 KHz
Accuracy Basic
Accuracy : 0.3%
Display 5 digits
display for both
primary and secondary
parameters
L 100 Hz, 120 Hz 1 mH
- 9999 H
1 KHz 0.1 mH - 999.9
H
Measurement C 100
Hz, 120Hz 1 pF - 9999
mF Range 1 KHz 0.1
pF - 999.9 mF
R, |Z| 0.0001V- 999.9
MV
D, Q 0.0001 – 9999
D% 0.0001% - 9999%
Test Level 120 Hz 0.3
Vrms (1 ±15%)
(Range Auto 1 KHz
22
and Open 100 Hz 0.42
Vrms (1±15%)
Circuit) Ranging Mod
Auto and Hold
Equivalent Parallel and
Series
Circuit Display Direct,
DABS and D%
Correction Open and
Short Zeroing
Terminals 5 terminals
Comparator 4 Bins :
NG, P1, P2 and P3
D% -9999% -
99999%
L 0.0001 mH - 99999H
Limit Setup Nominal C
0.0001 pF - 99999 mF
Range R 0.0001 V-
99999 MV
Z 0.0001 V- 99999 MV
Alarm Mode NG, P1,
P2, P3 and OFF
Power Supply 9V
battery or DC12V
(100mA) adapter
14 Strain Gauge set up STRAIN GAUGE 1 Essential Can
TRAINER WITH be shared with
INSTRUMENTATION other lab.
AND INDICATOR
Trainer kit consists of
Whetstone bridge,
Cantilever type loading
arrangement, on which
2 strain gauges are
mounted, Weights up to
2Kg, DC amplifier,
Digital indicator in
terms of gms. Facility
to select Quarter and
Half bridge mode.
Should be housed in
transparent acrylic
cover so that strain
gauges are visible to
23
students. Inbuilt DC
regulated Power supply
etc
15 Temperature Trainer kit suitable to 1 May be shared
Measurement using measure the temperature with other lab
using K type Cr-Al
Thermocouple
Thermocouple housed in
S.S. type industrial
housing. Set up should be
provided with Heater
which can go upto 200
deg C with facility to vary
heater power, Required
instrumentation with
amplifier, 3 1/2 digit
digital indicator of
temperature, In built DC
regulated power supply
etc.
16 Displacement DISPLACEMENT 1 Essential Can be
Measurement using TRANSDUCER shared with
(LVDT TYPE) WITH other lab
LVDT Trainer
INSTRUMENTATION
AND DIGITAL
INDICATOR.
Trainer kit consists of
industrial grade LVDT
of +/- 20 mm with
instrumentation,
Micrometer with
resolution of 0.1 mm,
Digital indicator in
terms of voltage. Built
in Excitation signal, DC
regulated power supply.
Facility to vary
excitation frequency
and amplitude and
observe its effect on
LVDT performance.
17 Thermistor trainer Trainer kit suitable to 1 Essential Can be
measure the temperature shared with
using thermister Set other lab
up should be provided
with Heater which can
go upto 200 deg C with

24
facility to vary heater
power, Required
instrumentation
constant current source
with amplifier, 3 1/2
digit digital indicator of
temperature, In built DC
regulated power supply
etc.
18 RTD Trainer kit Trainer kit suitable to 1 Essential Can be
measure the temperature shared with other
using PT 100 type lab
R.T.D. housed in S.S.
type industrial housing.
Set up should be
provided with Heater
which can go upto 200
deg C with facility to
vary heater power,
Required
instrumentation
constant current source
with amplifier, 3 1/2
digit digital indicator of
temperature, In built DC
regulated power supply
etc.
19 Ultrasonic flow 1MHz /5 MHz 1 Essential
transducer Trainer kit ultrasonic sensor Can be shared
with other lab
20 Piezoelectric/Capacitive 1 MHz piezoelectric 1 Essential
transducer Trainer kit crystal with measuring Can be shared
for pressure accessories with other lab
measurement

21 PH Meter pH electrode with at least 5 Essential


three different buffer
solutions

MSBTE NORMS AND STANDARDS FOR EQUIPMENT


LIST OF EQUIPMENT & MACHINERY
(Essential equipment/ Hand Tools) (Required for conducting the Practical)
1. Name of course/ Department:- Medical Electronics Dept.

25
2.Name of laboratory : COMPUTER CENTER & HARDWARE LAB
3 Name of Subjects ; Computer fundamental- MU1G
Programming In ”C” MU3G
Visual Basics MU4G
Simulation Software MU5G
Computer Hardware & Networking MU5G

MinQtty./Nos.
Sr. Name of Technical Specifications
No. Equipt./Machine
ry Remar
k if any
1 Computer System Intel processor core i3 or i7 or latest with 20 Essential
mother board Intel chipset 41/61/latest
with 4 USB,1 serial port, 1 LPT port,2GB
RAM DDR III,500 GB Sata Hard disk, 16”
or 18.5” LCD/LED monitor, ATX cabinet
with SMPS and lock system, DVD writer,
Keyboard, USB mouse,1 Gigabit Network
card/ latest configuration or Latest
configuration (or higher version)
2 LCD / Data SVGA/XGA 800x600 Lamp Life 01 Essential
Projector Span (2000-2500 Hrs) 1200 /1500
Lumen (Min) with Screen and stand or
Latest with better lumens and
additional facility
3 Printer Laser Printer , 15ppm 01 Essential

4 Modem External Dial up with internet 01 Essential


connection ( Broadband or any
other high speed Connection )
5 24 Port Ethernet Switch ( 1Giga or 10 Gbps) 01 Essential
Switch

6 UPS 6 KVA Online, 6 Hrs. Backup 02 Desirable


7 Scanner A4 size flat bed type 02 Essential

8 Windows- 7 MS Windows 7 OS 01 with 20 user Essential


(Operating License
System)
9 MS-Office 2010 Standard edition 01 with 10 user Essential
License
10 Turbo C Standard edition 20 user Essential

11 MS Visual Standard edition 01 with user Essential


Studio License

26
12 Antivirus Any suitable and current version As per no. of Essential
Software system
13 MATLAB or Basic MATLAB with essential tool Box 10 User Essential
any other such as Simulink , Sim electronics Signal License
Processing , Control system toolbox, DSP ,
equivalent Communication system , Sim power
software

MSBTE NORMS AND STANDARDS FOR EQUIPMENT


LIST OF EQUIPMENT&MACHINES
(Essential equipment/ Hand Tools) (Required for conducting the practical)
1. Name of course/ Department:- Medical Electronics Dept.
2.Name of laboratory : ELECTRONICS WORKSHOP
3 Name of Subjects Basic Workshop Practice MU1G
Electronic workshop MU2G
Industrial Project MU6G
Sr. Name of Equipt Technical Specifications MinQtty.
No. ./Machinery /Nos.
Remark if
any
1 Display charts for Display char for symbols of various components 01 for Essential
symbols Safety charts wall mounted type with better visibility each
2 Temperature Accurate and advanced temperature Control with 02 Desirable
controlled micro controller technology User-friendly operation
soldering Gun Set / Read of temperature Increase and Decrease of
keys to set temperature once set the read temperature
will display after two seconds by default Temperature
control accuracy ± 1°C Last set value of temperature
is stored in memory
Power consumption 60 W Input voltage 170 to 270 V
(190 to 270V ) Temperature range 180 to 270 V ( 180
to 480 °C) Temp stability ± 10°C
Temp accuracy ± 1°C of tolerance at idling time Tip
to ground potential under 2 mv
Tip to ground resistance under 2 Ohms or better
specifications
3 Display chart Chart shall display wave soldering principle and 01 Desirable
for wave actual process photograph
soldering and
DIP soldering
4 Digital 3.5 digit /4.5 digit with R , V, I measurements, diode 05 Essential
Multimeter and BJT testing
5 Analog Suitable to measure AC/DC voltage , Current and 05 Essential
Multimeter Resistance
DC voltage Range 400mV to 1000 V
AC Voltage Range 4V to 750 V
DC current 4 mA to 10A
AC current 4 mA to 10 A Resistance 400 Ohm to 40
Mohm or any other better specifications and
facilities
27
7 CRO Dual Channel, 4 Trace CRT / TFT based 08 Essential
Bandwidth 20 MHz/30 Mhz suitable
X10 magnification 20 nS max sweep rate, Alternate
triggering Component tester and with optional
features such as Digital Read out , USB interface Any
other Oscilloscope with additional features are also
8 1 Mhz or / 3MHz Microcontroller Based Function 05 Essential
Pulse Generator with40MHz Frequency Counter with
Function Sine, Triangle, Square, Pulse, Pump and TTL outputs,
generator Modulations, 16X2 character LCD display20 Vpp
output and DC Offset 40 MHz Frequency Counter
with FM Modulation
9 Parameter L-Q, C-D, R-Q and Z-Q 02 Essential
Frequency 00 Hz, 120 Hz and 1 KHz
LCR Q meter Accuracy Basic Accuracy : 0.3%
Display 5 digits display for both primary and
secondary
parameters
L 100 Hz, 120 Hz 1 mH - 9999 H
1 KHz 0.1 mH - 999.9 H
Measurement C 100 Hz, 120Hz 1 pF - 9999 mF
Range 1 KHz 0.1 pF - 999.9 mF
R, |Z| 0.0001V- 999.9 MV
D, Q 0.0001 – 9999
D% 0.0001% - 9999%
Test Level 120 Hz 0.3 Vrms (1 ±15%)
(Range Auto 1 KHz
and Open 100 Hz 0.42 Vrms (1±15%)
Circuit) Ranging Mod Auto and Hold
Equivalent Parallel and Series
Circuit Display Direct, DABS and D%
Correction Open and Short Zeroing
Terminals 5 terminals
Comparator 4 Bins : NG, P1, P2 and P3
D% -9999% - 99999%
L 0.0001 mH - 99999H
Limit Setup Nominal C 0.0001 pF - 99999 mF Range
R 0.0001 V- 99999 MV
Z 0.0001 V- 99999 MV
Alarm Mode NG, P1, P2, P3 and OFF
Power Supply 9V battery or DC12V (100mA) adapter
10 Tests a wide range of Analog and Digital IC's such as 01 Essential
74 Series, 40/45 Series of
Analog digital CMOS IC’s It can test Microprocessor 8085, 8086,
IC tester Z80, 8051, 89c51 It tests Peripherals like 8255,
8279, 8253, 8259, 8251, 8155,
6264,62256,8288,8284 t tests Opamp,555,
Transistor Arrays, Analog switches, Opto
couplers and Others It tests 7 segment display of
common cathode & common anode type IC testing
741 , 555 ,556 ,565 it has Auto search facility of
IC’s
Test by: Truth table/sequence table comparison ZIF:
40 pin DIP ZIF sockets Keys: 28 cherry keys Key pad

28
with numerical & functional keys Display: 9 Digit
Seven Segment Display Supply Input Voltage: 230V
AC
11 Fixed power supply based on 7805 , 7812 with 500 05 each Essential
ma / 1A current rating
Simple Fixed
output regulated
Power supply
based on 78XX
12 Intel processor core i3 or i7 or latest with mother 05 Essential
board Intel chipset 41/61/latest with 4 USB,1 serial
Computer port, 1 LPT port,2GB RAM DDR III,500 GB Sata
System Hard disk, 16” or 18.5” LCD/LED monitor, ATX
cabinet with SMPS and lock system, DVD writer,
Keyboard, USB mouse,1 Gigabit Network card/ latest
configuration or Latest configuration (or or
higher version)
13 SVGA/XGA 800x600 Lamp Life Span 01 Essential
(2000-2500 Hrs) 1200 /1500 Lumen (Min) with
LCD / Data Screen and stand or Latest with better lumens and
projector additional facility
14 Analog Digital, Symbolic, RF, VHDL, MCU and 01 with 5 Essential
mixed- 4mode circuit simulation & PCB Design Easy user
PCB software to use schematic entry
Powerful Analysis Tools including
Circuit can be edited during operation
Develop, Run, Debug and Test VHDL & MCU
applications Unknown circuit parameters can be
determine
automatically so that network can produce a
predesigned target values Advanced presentation
tools Importing spice modes
15 This is a table top unit which serves as contact printer 01 Essential
for developing the films. The films are used for
PCB art work further PCB development.
negative , Operating Mode : Manual / Automatic
positive Timer : Adjustable from 1 Sec to 10 Sec with 1 sec
preparation interval Display : 16 x 2 LCD for timer and lamp
system status display Exposing area : 20” x 10” Buzzer : For
timer indication
Lamp indicator : Status of internal exposing lamp
16 The drill machine is used for making drills in the 01 Essential
PCB. This is provided with different
PCB bench size of drill bits for making drills in the PCB.
drilling m/c Supply : 230V AC ± 10%, 50Hz
RPM : 1500 which are adjustable in steps.
17 This is a table top unit for etching the PCB. This unit 01 Essential
removes unused copper from
PCB etching PCB. This removal is carried by a chemical process
system which takes place in the
machine. Machine Type : Spray Etching machine
Spray Motor : 0.6 HP chemical pump Timer :
Adjustable from 1 min to 30 min in interval of 5 min.
Display : 16 × 2 LCD for timer. Buzzer : For timer
29
indication
Dipping area : 12” × 10” Spray Mode : Automatic /
Manual or with any other better specifications
18 15 Watt , 05 Essential
25 Watt 01
Soldering Gun With various type of bit set and gun stand
40 Watt,
Laboratory shall have discrete components of various ratings -- such as resistors, capacitors , inductors , diodes,
BJT, FET , SCR, UJT, TRIAC, DIAC , LED , Photodiode, IC 741, IC 555, seven segment display, switches ,
transformers , breadboard and cables. Components shall store in stack component organizer.

ANNEXURE - I
MSBTE NORMS AND STANDARDS FOR EQUIPMENT
LIST OF EQUIPMENTS & MACHINERY
(Essential equipment/ Hand Tools) (Required for conducting the Practical)

1. Name of course/ Department:- Medical Electronics Dept.


2. Name of laboratory: MEDICAL ELECTRONICS LAB
3 Name of Subjects: Analytical Equipment MU5G
Diagnostic Equipment MU5G
Intensive care equipments MU6G
Medical Imaging Equipment MU6G
Therapeutic Equipment MU6G
Human Biology MU4G

Sr Minimum
Name of the Equipment Technical Specification Remark
No Quantity
1 Digital Storage Oscilloscope Bandwidth : 50/100MHz TFT Colour 2 Essential
LCD Dual Channel
Real Time Sampling: 1GSa/s
Equivalent Sampling 25GSa/s
Memory 1M pts 10 Waveforms & 10
Setups can be stored
Autoset Function s 20 Auto
Measurement of Vpp, Vmax, Vmin,
Vtop, Vbase, Vamp, Vavg, Vrms,
Overshoot Preshoot, Frequency,
Risetime, Falltime, Delay 1 -2, Delay 1
-2, +Width, -Width, +Duty, -Duty
Mathematical Functions : Add, Subtract,
Multiply & FFT Adjustable Digital
Filters (HPF, LPF, BPF & BRF)
Cursor Measure : Auto, Manual, Track
Single shot triggering mode Built-in
FFT& USB Interface Ultra scope: PC
control & Analysis Software
Interpolation sinx/x
Acquisition Modes : Normal, Average,
30
Peak detect or any other better
specifications
2 Cathode Ray Oscilloscope Dual channel, min freq. 20MHz 4 Essential

3 Digital Multimeter 3.5 digit /4.5 digit with R , V, I 4 Essential


measurements
8 1 Essential
Colorimeter may be shared
with other lab

9 1 Essential
Spectrophotometer may be shared
with other lab
10 1 Essential
Flame Photometer may be shared
Scrap equipments from with other lab
pathology labs or hospitals may
11 be procured for observing 1 Essential
Ultrasonic Cleaner internal parts & circuitry.

12 1 Essential
Centrifuge

13 1 Essential
Hot Air Oven

14 Autoclave 1 Essential

15 1 Essential
Sterilizer(Clinical)

16 1 Essential
Electrophoresis

17 Incinerator Visit can be arranged to 1 Desirable


Biowaste management plant
18 PH Meter pH electrode with at least three 5 Essential
different buffer solutions
19 Sphygmomanometer with Mercury Manometer 5 Essential
stethoscope
20 Pulse Oxymeter. May be procured (may be 1 Essential
second hand but in working
21 Plethysmograph. condition) equipments from 1 Essential
hospitals/manufacturing
companies else trainer kits can
22 Digital Temperature Meter 1 Essential
be used.

31
23 Respiration Rate Meter 1 Essential

24 ECG Using 12 Lead 1 Essential


Configurations

25 EEG Machine 1 Essential

26 Audiometer 1 Essential

27 GSR Meter. 1 Essential

28 Phonocardiogram 1 Essential

30 Nebulizer Sample uptake min. 25ulit/m 1 Essential


Gas flow range 0.6-1.2 lit/min
29 DC Defibrillators Hospital visit can be arranged to 1 Desirable
perform practical
31 Ventilator 1 Desirable

32 Anesthesia Machine 1 Desirable

33 Infusion Pump 1 Desirable

34 Central Monitor 1 Desirable

35 Hemodialysis Machine 1 Desirable

36 Temperature Control Baby 1 Desirable


Incubator

37 Bedside Monitor 1 Desirable

38 UV & IR lamp Trainer Kit IR Lamps- 1 Essential


250-500W (small lamps)
750-1000w(Large lamps)
UV lamps-
14-600w
39 Microwave Diathermy Freq. 433.92MHz -2450MHz 1 Essential
Machine Trainer Kit
41 Nerve & Muscle Stimulator Output voltage 0-150v 1 Essential
Trainer Kit Current upto 80mA

43 Solid State Cautery Machine Coagulation 150W 1 Essential


Cutting 400W
Trainer Kit /ESU Trainer Kit Freq.250KHz to 1 MHz

32
44 Ultrasound Therapy Trainer 1 MHz Frequency 1 Essential
Kit
45 Shortwave diathermy 500W ,freq. 27.12MHz 1 Essential
Machine Trainer Kit
46 CT scanner Visit can be arranged to 1 Desirable
Hospitals/Medical imaging
47 Ultrasound scanner centre for performing 1 Desirable
practical.
48 MRI scanner 1 Desirable

49 X-ray machine 1 Desirable

58 Endoscopy 1 Desirable

59 Linear array Ultrasound 1 Desirable


transducer.

60 Phase array Ultrasound 1 Desirable


transducer.

61 CCTV system used in 1 Desirable


fluoroscopy

62 Microscope Compound/ light 5 Essential

63 Human tissue slides Different tissues 25 Essential

64 Models & Charts Cardiovascular System 1 each Essential


Respiratory System
Digestive System
Urinary System
Nervous System
Reproductive system

65 Models & Charts of sub organs Cardiovascular System -Heart 1 each Essential
Respiratory System- Lungs
Digestive System- Alimentary
track

33
Urinary System - kidney,
Nervous System- brain
Reproductive system
Eye,ear Human body model

NOTE: The practicals under subject Human Biology can be performed in Pathology lab./ Science
college/ Hospitals.