You are on page 1of 18

ENGINEERING DESIGN PLAN (EDP)

ENGINEERING DESIGN PLAN (EDP)

6500 2 NODE SHELF FOR COMMISSIONING (CEC)

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 1


ENGINEERING DESIGN PLAN (EDP)

LEGAL NOTICES
THIS DOCUMENT CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION OF CIENA CORPORATION AND ITS
RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE OR DISCLOSE ITS CONTENTS, OR
TO MANUFACTURE, USE, OR SELL ANYTHING THAT IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE, OR USE IN
WHOLE OR IN PART WITHOUT THE SPECIFIC WRITTEN AUTHORIZATION OF CIENA CORPORATION IS STRICTLY
FORBIDDEN.
EVERY EFFORT HAS BEEN MADE TO ENSURE THAT THE INFORMATION IN THIS DOCUMENT IS COMPLETE AND
ACCURATE AT THE TIME OF PUBLISHING; HOWEVER, THE INFORMATION CONTAINED IN THIS DOCUMENT IS
SUBJECT TO CHANGE.
While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing
CIENA PROVIDES THIS DOCUMENT “AS IS” WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS
OR IMPLIED. The information and/or products described in this document are subject to change without notice. For the most
up-to-date technical publications, visit www.ciena.com.
Copyright© 2015-2019 Ciena® Corporation – All Rights Reserved
The material contained in this document is also protected by copyright laws of the United States of America and other countries.
It may not be reproduced or distributed in any form by any means, altered in any fashion, or stored in a database or retrieval
system, without the express written permission of Ciena Corporation.
Security
Ciena cannot be responsible for unauthorized use of equipment and will not make allowance or credit for unauthorized use or
access.
Contacting Ciena
Corporate headquarters 410-694-5700 or 800 -921-1144 www.ciena.com
Customer technical support/warranty
In North America 1-800-CIENA24 (243-6224) Email: CIENA24@ciena.com
410-865-4961

In Europe, Middle East, 800-CIENA-24-7 (800-2436-2247) Email: CIENA24@ciena.com


and Africa +44-207-012-5508

In Asia-Pacific 800-CIENA-24-7 (800-2436-2247) Email: CIENA24@ciena.com


+81-3-6367-3989
+91-124-4340-600

In Caribbean and Latin 800-CIENA-24-7 (800-2436-2247) Email: CIENA24@ciena.com


America 410-865-4944 (USA)
Sales and General Information 410-694-5700 E-mail: sales@ciena.com

In North America 410-694-5700 or 800-207-3714 E-mail: sales@ciena.com

In Europe +44-207-012-5500 (UK) E-mail: sales@ciena.com

In Asia +81-3-3248-4680 (Japan) E-mail: sales@ciena.com

In India +91-124-434-0500 E-mail: sales@ciena.com

In Latin America 011-5255-1719-0220 (Mexico City) E-mail: sales@ciena.com

Training E-mail: learning@ciena.com

For additional office locations and phone numbers, please visit the Ciena website at www.ciena.com

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 2


ENGINEERING DESIGN PLAN (EDP)

Contents
1) SEATTLE TO VANCOUVER COMMISSIONING INFORMATION .......................................... 4
2) SHELF INVENTORY ................................................................................................................. 7
3) SHELF LEVEL VIEW ................................................................................................................ 9
4) OSRP PROVISIONING........................................................................................................... 11
5) PHOTONIC PROVISIONING.................................................................................................. 11
(a) Photonic Configuration Management. ........................................................................ 11
(b) Slot & TID Sequence................................................................................................... 12
(c) Adjacency Provisioning .......................................................................................... 13
6) SERVICE PROVISIONING ..................................................................................................... 14
(a) Sub Network Connections........................................................................................... 14
7) SHELF CONNECTIVITY ......................................................................................................... 15
(a) Photonic Network ........................................................................................................ 15
(b) OTS Schematic ....................................................................................................................... 16

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 3


ENGINEERING DESIGN PLAN (EDP)

1) COMMISSIONING INFORMATION

1.0 NE Identification

DEFAULT NE NAME: OME-000102030100 OME-000102030200


NE Type: 32-SLOT 32-SLOT
Release REL 1241Z.BA REL 1241Z.BA
NE Name: SEATTLE VANCOUVER
Extended NE Name: SEATTLE VANCOUVER
CLLI: SEATTLE VANCOUVER

2.0 NE Configuration

Shelf Number: 11 15
Shelf IP Address: 192.168.0.1 192.168.0.2
Site ID: 1 2
Site Name: SEATTLE VANCOUVER
Location:
TID Consolidation: ENABLE ENABLE
TID Consolidation Primary: ENABLE ENABLE
NE Mode: SONET SONET
IPv4 ON ON
IPv6 OFF OFF
IPv6 Hop Limit 64 64
IPv6 capability NO NO
GCC0 Mode : DISABLED DISABLED
NDP Mode ENABLE ENABLE
Alarm Correlation: OFF OFF
Bay Number: 0 0
Frame identification code:
Subnet name:
Shelf Synch YES YES

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 4


ENGINEERING DESIGN PLAN (EDP)

3.0 GNE Configuration

GNE: NO NO
Single Shelf IP: NO NO
GNE Group:
Primary:* NO NO
CONFIG (mandatory):

4.0 Auto Equipping

Enabled slots: 1-62 1-62

6.0 OSPF Router Provisionning

Router ID: 192.168.0.1 192.168.0.2


Route Summarisation: ON ON
Autonomous System Border
Router: OFF OFF
Opaque Filter OFF OFF
Shelf IP Re-distribution OFF OFF

8.0 Shelf IP Provisioning

IP Address: 192.168.0.1 192.168.0.2


Subnet Mask: 255.255.255.255 255.255.255.255
Routing Protocol: OSPF OSPF
Network Area: 1.1.1.1 1.1.1.1
Cost: 10 10
Dead Interval: 40 40
Hello Interval 10 10
Retransmit Interval: 5 5
Transmit Delay: 1 1
Priority: 1 1
AreaDefault Cost: 1 1
Area: OFF OFF
Authentication Type NULL NULL
Password:
Circuit Metric: 4 4
Opaque Link State Advertisement: ON ON

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 5


ENGINEERING DESIGN PLAN (EDP)

10.0 COLAN Provisioning

AID COLAN-1-X COLAN-1-X


IP Address: 192.168.0.1 192.168.0.2
Subnet Mask: 255.255.255.0 255.255.255.0
Proxy ARP: OFF OFF
Port Enabled: NO NO
Routing Protocol: NONE NONE
Network Area:
Cost:
Dead Interval:
Hello Interval
Retransmit Interval:
Transmit Delay:
Priority:
Area Default Cost:
Area:
Authentication Type
Password:
Circuit Metric (IISIS):

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 6


ENGINEERING DESIGN PLAN (EDP)

2) SHELF INVENTORY

SEATTLE

Shelf Physical
Shelf Name No. Slot No. Card Type PEC
SEATTLE 11 - 6500 32-Slot Packet-Optical Shelf Assembly NTK603AA
SEATTLE 11 1 MLA3 C-Band NTK552GA
SEATTLE 11 2 WSS Flex C-Band w/OPM 20x1 NTK553MA
SEATTLE 11 3 FILLED -
SEATTLE 11 4 CCMD12 C-Band NTK508FA
SEATTLE 11 31 OSC w/WSC 2 Port SFP 2 Port 10/100 BT NTK554BA
SEATTLE 11 31-1 OC-3 10-30dB CWDM 1511nm NTK592NB
SEATTLE 11 33 100G WL3 OCLD Metro w/EDFA 1xOTU4 C-Band NTK539UD
SEATTLE 11 34 100GMUX 10x10G MUX 10GE 10XSFP+ NTK529BA
SEATTLE 11 41 SP-2 NTK555EA
SEATTLE 11 43 Power Card 3x60A breakered NTK605CA
SEATTLE 11 44 Power Card 3x60A breakered NTK605CA
SEATTLE 11 45 Fan NTK607AA
SEATTLE 11 46 Fan NTK607AA
SEATTLE 11 47 Access Panel NTK605MA
SEATTLE 11 54 Fiber Interconnect Module (FIM) Type 4 NTK504CD

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 7


ENGINEERING DESIGN PLAN (EDP)

VANCOUVER

Shelf Physical
Shelf Name No. Slot No. Card Type PEC
VANCOUVER 15 - 6500 32-Slot Packet-Optical Shelf Assembly NTK603AA
VANCOUVER 15 1 MLA3 C-Band NTK552GA
VANCOUVER 15 2 WSS Flex C-Band w/OPM 20x1 NTK553MA
VANCOUVER 15 3 FILLED -
VANCOUVER 15 4 CCMD12 C-Band NTK508FA
VANCOUVER 15 21 100G WL3 OCLD Metro w/EDFA 1xOTU4 C-Band NTK539UD
VANCOUVER 15 22 100GMUX 10x10G MUX 10GE 10XSFP+ NTK529BA
VANCOUVER 15 38 OSC w/WSC 2 Port SFP 2 Port 10/100 BT NTK554BA
VANCOUVER 15 38-1 OC-3 10-30dB CWDM 1511nm NTK592NB
VANCOUVER 15 41 SP-2 NTK555EA
VANCOUVER 15 43 Power Card 3x60A breakered NTK605CA
VANCOUVER 15 44 Power Card 3x60A breakered NTK605CA
VANCOUVER 15 45 Fan NTK607AA
VANCOUVER 15 46 Fan NTK607AA
VANCOUVER 15 47 Access Panel NTK605MA
VANCOUVER 15 54 Fiber Interconnect Module (FIM) Type 4 NTK504CD

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 8


ENGINEERING DESIGN PLAN (EDP)

3) SHELF LEVEL VIEW

SEATTLE - 192.168.0.1

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 9


ENGINEERING DESIGN PLAN (EDP)

VANCOUVER – 192.168.0.2

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 10


ENGINEERING DESIGN PLAN (EDP)

4) OSRP PROVISIONING

OSRP Provisioning

Shelf Number: 11 15

OSRP ID: 1 1
Control Plane Type: L0 Provisioning L0 Provisioning

Node Name: SEATTLE VANCOUVER


Node ID: 0001 0002
OOB Local UDP Port: 51001 51001
TL1 IP Address: 192.168.0.1 192.168.0.2

5) PHOTONIC PROVISIONING
(a) Photonic Configuration Management.

Add OTS SEATTLE VANCOUVER

Shelf: 11 15
OTS: 1 1
Template Family: ROADM ROADM
Configuration: Channel access Channel access
Subtype: ROADM ROADM
OTS Optical system identifier: Dom0 Dom0
OTS Tx path identifier: 1 24
Rx Label: - -
Tx Label: - -
OSC: OSC-11-31-1 OSC-15-38-1
DOC site: TRUE TRUE
Associated OTS: - -
Provisioned Control Mode: Flexible Grid Capable Flexible Grid Capable
Autoroute: Disable Disable
CPS: ENABLE ENABLE
OSC OLF Only: DISABLE DISABLE
OSC Required: TRUE TRUE

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 11


ENGINEERING DESIGN PLAN (EDP)

(b) Slot & TID Sequence

NE SEATTLE VANCOUVER
SLOT SEQUENCE:
Sequence ID: SLOTSEQ-11-1-1 SLOTSEQ-15-1-1
Label: Main Main
Drop Sequence: LIM-11-1 LIM-15-1
WSS-11-2 WSS-15-2
Add Sequence: LIM-11-1 LIM-15-1
WSS-11-2 WSS-15-2

TID SEQUENCE: FIM-11-54 FIM-15-54


Sequence ID: TIDSLOTSEQ-11-54-1 TIDSLOTSEQ-15-54-1
Label : MPO MPO
Drop Sequence: WSS-11-2 WSS-15-2
Add Sequence WSS-11-2 WSS-15-2

Sequence ID: TIDSLOTSEQ-11-54-2 TIDSLOTSEQ-15-54-2


Label : MPO MPO
Drop Sequence: WSS-11-2 WSS-15-2
Add Sequence WSS-11-2 WSS-15-2

Sequence ID: TIDSLOTSEQ-11-54-10 TIDSLOTSEQ-15-54-10


Label : Out LC Out LC
Drop Sequence: CCMD12-11-4 CCMD12-15-4
Add Sequence CCMD12-11-4 CCMD12-15-4

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 12


ENGINEERING DESIGN PLAN (EDP)

(c) Adjacency Provisioning

NE SEATTLE VANCOUVER
ADJ-LINE:

Adjacency Type: LINE LINE


ADJ Facility Unit: Adj-11-1-5 Adj-15-1-5
Expected Far End Address
Format: TID-SH-SL-PRT TID-SH-SL-PRT
Expected Far End: VANCOUVER-15-1-8 SEATTLE-11-1-8
Non-Dispersion Shifted Non-Dispersion Shifted
Fiber Type Fiber Fiber
Target Span Loss (dB): 11.00 11.00

ADJ-TX:

ADJ Facility Unit: ADj-11-4-1 ADj-15-4-1


Node Type: 6500 6500
Expected Far End Address
Format: TID-SH-SL-PRT TID-SH-SL-PRT
Expected Far End: SEATTLE-11-33-1 VANCOUVER-15-21-1
Auto Discovered: Auto Auto
WL3 Modem 1xOTU4 C- WL3 Modem 1xOTU4 C-
Transmitter Type: Band (Colorless) Band (Colorless)
SEATTLE-VANCOUVER SEATTLE-VANCOUVER
Circuit Identifier 193.7125THz 193.7125THz

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 13


ENGINEERING DESIGN PLAN (EDP)

6) SERVICE PROVISIONING
(a) Sub Network Connections

Sub Network Connection:

Label: SEATTLE_VANCOUVER_193.7125THz
Local End Point:

Node: SEATTLE
End Point: ADj-11-4-3

Remote End Point:

Node: VANCOUVER
End Point: ADj-15-4-1

Primary State: IS

Center Frequency (THz): 193.7125

Routing List: NONE

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 14


ENGINEERING DESIGN PLAN (EDP)

7) SHELF CONNECTIVITY
(a) Photonic Network

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 15


ENGINEERING DESIGN PLAN (EDP)

(b) OTS Schematic

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 16


ENGINEERING DESIGN PLAN (EDP)

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 17


ENGINEERING DESIGN PLAN (EDP)

End of Lab

Copyright© 2015-2019 Ciena Corporation. All rights reserved. Revision A

October 2019 Page 18

You might also like