You are on page 1of 7

SteelMaster Enquiry

Al Qiddiya Pump station_SB_R60


Enquiry Ref: 0.S22180FES_SB_R60

Presented by: Suyog Bhere


Friday, October 6, 2023

MEIA

Subset: PUMP STATION Protection: 60 Minutes

Sq M Kgs Litres
Total 3250.180 4136.844 3087.198

Subset: SUNSHADE Protection: 60 Minutes

Sq M Kgs Litres
Total 129.070 233.463 173.635

Subset: TES POLISHING Protection: 60 Minutes

Sq M Kgs Litres
Total 83.060 113.893 84.996

Report Totals Sq M Cans (Number x Can size) Kgs Litres

SteelMaster 60SB 3436.760 164 x 20.000 4377.377 3266.701

SteelMaster 120SB 25.550 4 x 20.000 106.823 79.128

Standard: BS.BS5950 - Def/Sto

SteelMaster 60SB - [r5_CF5170] \ SteelMaster 120SB - [r6_CF845]

Page 1
SteelMaster Enquiry
Al Qiddiya Pump station_SB_R60
Enquiry Ref: 0.S22180FES_SB_R60

Presented by: Suyog Bhere


Friday, October 6, 2023

MEIA

Unprotected Area 0

Notes:

Standard: BS-BS5950 (Default).

All surface area considered in this schedule is as per the client provided information.

Clients are advised to cross-check DFTs against relevant certifications where available.

Clients are advised to cross-check all measures and assumptions used to prepare this report. Jotun shall be advised of any discrepancies accordingly. Jotun cannot be held contractually responsible
for any errors.

All sections are considered to be exposed to fire on 4-sides and assumed to be designed as Column/ALM (Axially Loaded Member).

Members noted as “BRACING” are considered as secondary steel sections/wind bracings with a maximum section factor of 200 m-1 (as per BS 5950-8).

Fittings (connections, baseplates, stiffeners, etc.) are not considered in this schedule, they shall be treated with the same DFT as the main member to which they are connected.

Items such as tension rods, girts, purlins, cold-rolled steel sections are not included in this schedule.

We understand there are no cell beams with no holes in their webs in this project.

Standard: BS.BS5950 - Def/Sto

SteelMaster 60SB - [r5_CF5170] \ SteelMaster 120SB - [r6_CF845]

Page 2
SteelMaster Enquiry
Al Qiddiya Pump station_SB_R60
Enquiry Ref: 0.S22180FES_SB_R60

Presented by: Suyog Bhere


Friday, October 6, 2023

MEIA

Subset: PUMP STATION Protection: 60 Minutes

Steel Type Designation Exposure Length # Sq M Temp Use HP/A Product Name WFT DFT Kgs Litres Reference Notes

1 EU HE HE 140 A 4 Sides 0.510 520 Column/ALM 255 SteelMaster 60SB 1.082 0.800 0.740 0.552

2 EU HE HE 200 A 4 Sides 18.090 520 Column/ALM 210 SteelMaster 60SB 0.884 0.654 21.429 15.992

3 EU HE HE 240 A 4 Sides 124.720 520 Column/ALM 180 SteelMaster 60SB 0.779 0.576 130.190 97.157

4 EU IPE IPE 200 4 Sides 912.230 520 Column/ALM 270 SteelMaster 60SB 1.176 0.870 1437.528 1072.782

5 EU IPE IPE 240 4 Sides 168.290 520 Column/ALM 235 SteelMaster 60SB 0.990 0.733 223.253 166.607

6 EU IPE IPE 270 4 Sides 545.930 520 Column/ALM 225 SteelMaster 60SB 0.945 0.699 691.311 515.904

7 EU IPE IPE 330 4 Sides 273.110 520 Column/ALM 200 SteelMaster 60SB 0.849 0.628 310.706 231.870

8 EU IPE IPE 450 4 Sides 1044.470 520 Column/ALM 160 SteelMaster 60SB 0.709 0.525 992.309 740.529

9 Plate Angle 100x100x5 4 Sides 0.620 500 Column/ALM 200 SteelMaster 60SB 0.939 0.695 0.780 0.582 (BRACING* )

10 Plate Angle 150x100x5 4 Sides 0.140 500 Column/ALM 200 SteelMaster 60SB 0.939 0.695 0.176 0.131 (BRACING* )

11 UEA 100x75x6 4 Sides 0.180 520 Column/ALM 335 SteelMaster 60SB 1.687 1.248 0.407 0.304

12 Plate Angle 150x100x5 4 Sides 0.520 500 Column/ALM 200 SteelMaster 60SB 0.939 0.695 0.654 0.488 (BRACING* )

13 EQ 50x50x5 4 Sides 19.020 500 Column/ALM 200 SteelMaster 60SB 0.939 0.695 23.932 17.860 (BRACING* )

14 EQ 75x75x5 4 Sides 1.520 500 Column/ALM 200 SteelMaster 60SB 0.939 0.695 1.912 1.427 (BRACING* )

Standard: BS.BS5950 - Def/Sto

SteelMaster 60SB - [r5_CF5170] \ SteelMaster 120SB - [r6_CF845]

Page 3
SteelMaster Enquiry
Al Qiddiya Pump station_SB_R60
Enquiry Ref: 0.S22180FES_SB_R60

Presented by: Suyog Bhere


Friday, October 6, 2023

MEIA

Subset: PUMP STATION Protection: 60 Minutes

Steel Type Designation Exposure Length # Sq M Temp Use HP/A Product Name WFT DFT Kgs Litres Reference Notes

15 EQ 75x75x6 4 Sides 1.570 520 Column/ALM 340 SteelMaster 60SB 1.726 1.277 3.631 2.710

16 Plate CHS 114.3x6.3 4 Sides 5.480 520 Column/ALM 170 SteelMaster 60SB 2.055 1.521 15.090 11.261

17 Plate CHS 114.3x8 4 Sides 2.640 520 Column/ALM 135 SteelMaster 60SB 1.509 1.117 5.339 3.984

18 Plate CHS 114.3x6.3 4 Sides 71.150 520 Column/ALM 170 SteelMaster 60SB 2.055 1.521 195.925 146.213

19 Plate CHS 168.3x8 4 Sides 15.290 520 Column/ALM 130 SteelMaster 60SB 1.455 1.077 29.811 22.247

20 Plate SHS 40x3.2 4 Sides 0.870 500 Column/ALM 200 SteelMaster 60SB 3.179 2.352 3.706 2.766 (BRACING* )

21 EU UPN,U,UE UPN 160 4 Sides 1.180 520 Column/ALM 225 SteelMaster 60SB 0.945 0.699 1.494 1.115

22 EU UPN,U,UE UPN 220 4 Sides 42.650 520 Column/ALM 190 SteelMaster 60SB 0.814 0.602 46.521 34.717

Total 3250.180 4136.844 3087.198

Standard: BS.BS5950 - Def/Sto

SteelMaster 60SB - [r5_CF5170] \ SteelMaster 120SB - [r6_CF845]

Page 4
SteelMaster Enquiry
Al Qiddiya Pump station_SB_R60
Enquiry Ref: 0.S22180FES_SB_R60

Presented by: Suyog Bhere


Friday, October 6, 2023

MEIA

Subset: SUNSHADE Protection: 60 Minutes

Steel Type Designation Exposure Length # Sq M Temp Use HP/A Product Name WFT DFT Kgs Litres Reference Notes

1 EU IPE IPE 270 4 Sides 25.480 520 Column/ALM 225 SteelMaster 60SB 0.945 0.699 32.266 24.079

2 EU IPE IPE 300 4 Sides 75.050 520 Column/ALM 215 SteelMaster 60SB 0.901 0.667 90.611 67.620

3 EQ 50x50x5 4 Sides 2.990 500 Column/ALM 200 SteelMaster 60SB 0.939 0.695 3.763 2.808 (BRACING* )

4 Plate CHS 88.9x5 4 Sides 25.550 520 Column/ALM 210 SteelMaster 120SB 3.097 2.230 106.823 79.128

Total 129.070 233.463 173.635

Subset: TES POLISHING Protection: 60 Minutes

Steel Type Designation Exposure Length # Sq M Temp Use HP/A Product Name WFT DFT Kgs Litres Reference Notes

1 EU HE HE 160 A 4 Sides 24.550 520 Column/ALM 235 SteelMaster 60SB 0.990 0.733 32.567 24.304

2 EU IPE IPE 200 4 Sides 34.540 520 Column/ALM 270 SteelMaster 60SB 1.176 0.870 54.429 40.619

3 EQ 50x50x5 4 Sides 4.490 500 Column/ALM 200 SteelMaster 60SB 0.939 0.695 5.649 4.216 (BRACING* )

4 EU UPN,U,UE UPN 220 4 Sides 19.480 520 Column/ALM 190 SteelMaster 60SB 0.814 0.602 21.248 15.857

Total 83.060 113.893 84.996

Standard: BS.BS5950 - Def/Sto

SteelMaster 60SB - [r5_CF5170] \ SteelMaster 120SB - [r6_CF845]

Page 5
SteelMaster Enquiry
Al Qiddiya Pump station_SB_R60
Enquiry Ref: 0.S22180FES_SB_R60

Presented by: Suyog Bhere


Friday, October 6, 2023

MEIA

JSES Disclaimer
• The Jotun SteelMaster Enquiry System (JSES) has been developed to assist Jotun customers in the estimation of SteelMaster quantities required for intumescent paint
projects. Jotun have taken reasonable care and skill to ensure that, when used correctly, the JSES produces accurate guidance as to the volume of SteelMaster coatings
required. The information provided in this schedule should be verified with the relevant standards and certificates.

• Results are provided without any warranty of any kind, express or implied. Jotun accepts no liability
whatsoever for loss incurred by inaccurate or unreliable results received from the JSES and which is due to human operator input of inaccurate, estimated or erroneous
data.

• Where the operation of the JSES is dependent on third party data no liability is accepted by Jotun in respect of any third party material.

• Unless specifically noted elsewhere in this report, the Dry Film Thicknesses (DFT’s) assume the limiting temperatures as stipulated in the "ASFP Advisory Note" submitted
with this schedule.

• If the composite floor trapezoidal option has been utilised in the enquiry, the operator needs to be made aware that this may not be the most cost effective option. It is an
option to fill the voids between the top of the steel and the floor decking with fire stop blocks which may or may not prove to be a more suitable and competitive option for
the client. The operator should also be aware that for periods of fire resistance in excess of 90 minutes an increased paint film thickness is not an option and the voids must
be filled with fire stop blocks. In any event the operator is deemed to have satisfied themselves with the industry guidelines for these scenarios as laid out in the latest
revision of the ASFP 'Yellow Book.'

• All supplied intumescent thicknesses are theoretical only and the applicator is recommended to include for their normal loss factor (wastage/ coat back/ overspray etc.) in
addition to these quantities.

• Contractors must satisfy themselves with the accuracy of the square metre areas provided in this report.

• Primers and topcoats must be compatible with SteelMaster. SteelMaster should not be exposed to an environment which is outside the manufacturer’s guidance.
Discuss with Jotun for specific system recommendation.

• This schedule is produced using JSES software and cannot be altered or tampered with using any proprietary editing software, the users of this report can verify by
sending the copy of the schedule to FireEstimation@jotun.com

Standard: BS.BS5950 - Def/Sto

SteelMaster 60SB - [r5_CF5170] \ SteelMaster 120SB - [r6_CF845]

Page 6
SteelMaster Enquiry
Al Qiddiya Pump station_SB_R60
Enquiry Ref: 0.S22180FES_SB_R60

Presented by: Suyog Bhere


Friday, October 6, 2023

MEIA

• The information contained in this report is privileged information and has been produced under the terms of the JSES software license. This information must not be
passed on to any third party without written permission from Jotun.

Standard: BS.BS5950 - Def/Sto

SteelMaster 60SB - [r5_CF5170] \ SteelMaster 120SB - [r6_CF845]

Page 7