A 05.06.

23 Indicative lighting layout shown


B 06.11.23 Updated as per client email 01.11.23

"AC." Denotes ceiling panels to


AC. remain blank to allow
maintenance access to top of
point of use water heater

Lights to WCs to be PIR STORE


sensor controlled GF022

WC GF017
Ae A A
2550
B
Be B
A A A A A A A A A SWITCH
AC.
2450 Dis. WC B ROOM
B B GF021 GF023
2450 2450 2450
AC.
Be

2450 GF015 GF016


A A A A A A 2450 Ae A A A
LOBBY 2450
GF018 Be
A Be 2450 GF024

A Ae A Ae Ae A A Ae Ae Ae
2450 Ae 2450
CORRIDOR
GF019
Ae A A

CPD Ae 2450
GF020
Ae Ae
2450 Ae
KITCHEN
2450 GF026
A LOBBY
A GF014 GF030

Be 2450 Ae
STORE
GF031
A

A
GF013

2450
A A

A Ae
2450

PRIMARY works above GF025


green dashed line. No
works below line aside
from external door and
window replacement A A

PRIMARY works above green


dashed line. No works below
line aside from external door
and window replacement
N

REFLECTED CEILING PLAN


Scale 1:50
PROPOSED CEILING TILES
Square hatch denotes proposed areas to receive new suspended ceiling. Any existing
ceiling tiles or grids within these areas to be carefully stripped out and carted away. For
0 1 2 3 4 (metres) 5 ceiling tile type see drawing 012 Finishes Plan. New 600x600 LED lighting to all areas
of new suspended ceiling grid.

SHADOW BATTEN
38mm x 50mm shadow batten to be installed around perimeter, to be primed using
Dulux Trade Quick Drying Primer undercoat and finished with 2no. coats of Dulux
Satinwood, colour to be RAL7016 anthracite grey.

CEILING VOID
Contractor to identify any superfluous elements such as redundant
M&E/services/pipework/wiring/trunking etc. and carefully remove and cart away.
Builders clean and wipe down trusses and ledges to remove dust. Fire detection to be
installed to all ceiling voids.

NOTES
1234 denotes proposed ceiling height, ceiling heights to each room to be confirmed,
2450mm height shown for costing purposes. GENERAL NOTES:

Contractor to ensure all materials and elements are


installed to manufacturers instructions / recommendations
CHADWICK
and current building regulations. This drawing pack is to
LIGHTING
Contractor to allow for all new lighting, wiring and switches etc. Light levels to
be read as one entity and be fully coordinated. All
Architects drawings to be read in conjunction with all
DES GN
achieve 500 lux. Lighting layout shown is indicative only. other associated specialist sub-contractors drawings. In
the event of any conflicting information the contractor is to
seek clarification from the Architect prior to ordering of
A - 600 x 600 modular recessed LED luminaire. NVC Sterling UGR19 LED materials. At no time will additional costs be considered
A
light ref. NST/UGR19/66/LO/840 or similar approved. due to works because of lack of coordination. IF IN
DOUBT ASK, DO NOT ASSUME.

Ae - 600 x 600 emergency modular recessed LED luminaire with 3 hour The Contractor is to allow for ALL making good of
Ae battery back up. NVC Sterling UGR19 LED light ref. NST/UGR19/66/LO/840 rooms/corridors/lobbies in areas of disruption including
and N/REC/M3/PACK or similar approved. area adjacent to the primary site where windows and

making good to all new window/door locations for


B - Circular LED downlighter, die cast aluminium bezel. NVC Wisconsin ref. re-plastering, skim and paint finish to walls and making Client.
B
NWS20/LED/840 or similar approved. good of floors in areas of disruption.

Be - Circular LED emergency downlighter with 3 hour battery backup. Die


Be
cast aluminium bezel. Ref. NWS20/LED/M40/840 or similar approved.
University Hospitals of Leicester
NHS Trust

Project.

Drawing Title.

Drawing Status.

TENDER
Scale. Date. Dwg No.