I. Objective:
To determine and evaluate the quality of a pre-painted galvalume coil (PPGL) without
undergoing acid pre-treatment.

II. Result and Discussion

Table 2. Quality Evaluation Data

Quality Performance
ACTUAL

Gloss 73.2
Shade Matched
Cross Hatch Passed
Solvent Rub Passed
Coin Scratch Passed
Flexibility 1T
Pencil
2H - Passed
Hardness
Impact Test Passed

Visually acceptable, no defects visually found

After processing and evaluation of the coil, the PPGL without acid treatment exhibits the same
standard properties and result. The sample passed all the testing and no defects found.

TILE PROFILE

During roll forming testing the panel shows a good quality and no paint peel off. No other visible
defects found.

III. Conclusion and Recommendations

Upon initial trial run we therefore concluded that the used Hydrochloric acid (HCl) as used in
cleaning and surface treatment of the pre-painted galvalume coil has no significance. The coil exhibits
Prepared by: JMV
QA REPORT
Noted by:
PRODUCTION TRIAL OF PPGL COIL WITH NO ACID
Title PRE-TREATMENT Date: February 3, 2023
the same standard properties and no visible defects found. The trial coil can also be used by roll
forming.
For this reason, we recommend the non-usage of acid treatment on the coil coating process on
the next runs of the color coating line but we will also subject the trial coil in our accelerated
weathering test for additional evaluation and closely monitor the produced coil. The remaining
chemicals will be use in the wastewater treatment.