Professional Documents
Culture Documents
SE Nombungo Lubango 60/15KV 41.7 G.652 0.275 Huawei OSN 9800 M24 2×10Gbps
SE Nombungo Quilemba 60/15KV 19.32 G.652 0.275 Huawei OSN 9800 M24 2×10Gbps
SE Nombungo Namibe 220/60KV 202 G.652 0.275 Huawei OSN 9800 M24 4×10Gbps
Lubango
170.0km 173.0km
49.75dB 50.58dB
Legends:
FOADM
Namibe
OLA
➢ The other DWDM Network to bear the office network and leasing the network to other users in the future, such as the VoIP, CCTV, Access
Control, OA, etc.
➢ The fiber type is G.652, fiber attenuation factor of 0.275 dB/KM, margin 3dB.
➢ Because the distance between the Belem de Dango and Nombungo sites is 343km, one hop of transmission equipment cannot directly
transmit data. Therefore, a repeater station is required. Assume that a station is added as a relay station in the middle. The relay station
requires infrastructure such as equipment rooms, air conditioners, and power supply.
➢ In SDH transmission network, the optical modules connected between the the SE Nombungo site and SE Belem do Dango, the SE Nombungo
site and Namibe sites are colored optical modules. DCMs are configured between the SE Nombungo site and Namibe sites. The information
about optical modules and DCMs needs to be updated after the site survey.
➢ Long-distance optical transmission is designed using Raman board. Raman amplifiers pose high requirements on the quality of optical cables.
To be specific, no connector is allowed within 40 km near the Raman amplifier. And fiber burning is always occurred if maintenance is not
correct.
➢ All of the configuration are proposed. The configuration will be updated based on fiber type, fiber attenuation factor, distance changed and
optical mode type.
VoIP VoIP
SCADA
SDH Plane SCADA
◼ SDH Plane: Two pairs of fibers (1+1) bear production operation such as relay protection.
◼ DWDM Plane: one pair of fibers bear Non-production business and lease line business.
170km
49.75dB
173km
50.58dB
202km
58.55dB
+Dummy Light B F
M4 170.00km 173.00km D48
8V A A106 S R03 A101 S S R03 A101 S A106
D D (E)
(E) R R R R
A 49.75dB 50.58dB A
X X X X M4
D48 A106 P A101 F R03 F A101 F R03 F A106 P A 8V
(E)
G652 G652 (E)
A F
+Dummy Light
*Nombungo Namibe
A +Dummy Light
M4
D 202.00km D48
8V A105 S R03 A101 S C F A106
A D (E)
(E) R R
P 58.55dB A
X X M4
D48 A106 X F C A101 F R03 F A105 P 8V
(E) F
G652 (E)
A
+Dummy Light
A A A
M4
D 41.70km D D48 M4 19.32km
8V A106 A106 D D D48
A A (E) 8V A106 A108
(E) A A (E)
14.47dB (E)
P P P 8.31dB P
M4 M4
D48 A106 X A106 X 8V D48 A108 X A106 X
(E) F F 8V
G652 (E) (E) F F
G652 (E)
A A A
Legend
Dispersion Compensation Dispersion Compensation Dispersion Compensation
Module,1525~1568nm(compensate Module,1525~1568nm(compensate Module,1525~1568nm(compensate
G.652 fiber),-319~- G.652 fiber),-635~- G.652 fiber),-953~-
A B C D48
48-Channel Demultiplexing Board
337ps/nm@1545nm(compensate 673ps/nm@1545nm(compensate 1009ps/nm@1545nm(compensate (E)
Dispersion Compensating
Fiber Amplifier,Pluggable Optical Fiber,1525~1568nm(For G.652 Fiber Amplifier,Pluggable Optical Fiber Amplifier,Pluggable Optical
A108
Amplifier, Extended C-band, Gain F
Fiber),-2001~- A106
Amplifier, Extended C-band, Gain A105
Amplifier, Extended C-band, Gain
8~14dB, Max 21.5dBm 1937ps/nm@1545nm(For 13~23dB, Max 21.5dBm 23~32dB, Max 23.8dBm Out,
Out,TNG3OACE108 120km),9.8dB,0.1dB,0.8ps,LC/UPC Out,TNG3OACE106 TNG3OACE105
Adapter,No Pigtail,266*238*45mm
FAN
Subrack_1
Subrack_1
OACE1
M DAP E2000 ODF
05(T) OACE101(R) R
4
P I
8
Subrack_2
OACE1 OACE1
01(1) 06(R) S C T
V R
0 L
- A
OACE1
DAPXF P 3
N T E 01(2) X
C C F
2 2
15 16 17 18 X X 19 20 21 22 23 24
1 1
P P
6 6
D D
4 4
8 8
- -
E E
1 2 3 4 5 6 71 72 7 8 9 10 11 12
FAN
C DAP DAP C
M
T OACE101(R) R D D T
4 Master- OSN 9800 M24:TO Nombungo
U P I 4 4 U
8 OACE1 OACE1
C T 8 8
V 01(1) S 06(1) PIU PIU EFI PIU PIU
P R 0 L - - P
- A
I OACE1 3 OACE1 E E I 100 101 102 103 104 105 106
E P
U 01(2) X 06(2) U
F
FAN
73/10 13/7 74/1
1 2 3 4 5 6 7 8 9 10 11 12
0 2 01
D D
A O
I 4 4
S P
DCM-652-A DCM-652-B T 8 8
T M
L - -
4 8
E E
T N
OSN 9800 M12:TO Lubango,Quilemba C C
13 14 15 16 17 18 19 20 21 22 2 2
X X
FAN 1 1
P P
M DAP DAP 6 6
A OACE1 OACE1 A OACE101(R) R
M 06(T) 06(T) M 4
U D D U P
A 4 O 4 8 OACE1 OACE1
X 4 4 X 01(1) S 05(1) C
S 8 OACE1 P OACE1 8 V R
8 8 0
T V 06(R) M 08(R) V - A
P - - P OACE1 P OACE1 3
4 - 8 - E 01(2) X 06(2)
I E E I
E DAPXF DAPXF E F
U U 1 2 3 4 5 6 71 72 7 8 9 10 11 12
73/10 13/7 74/1
1 2 3 4 5 6 7 8 9 10 11 12 FAN
0 2 01
DCM-652-A
DCM-652-A DCM-652-A
DCM-652-A DCM-652-C
DCM-652-A DCM-652-F
Nombungo-1
Namibe-1
Subrack_1 Subrack_1
E2000 ODF
Subrack_2
FAN
D D
A O
I 4 4
S P
T 8 8
T M
L - -
4 8
E E
T N
C C
13 14 15 16 17 18 19 20 21 22 2 2
X X
1 1
P P
M DAP DAP 6 6
OACE101(R) R
4
P
8 OACE1 OACE1
01(1) S 06(1) C
V R
0
- A
OACE1 P OACE1 3
E 01(2) X 06(2)
Master- OSN 9800 M12:TO Belem de Dango,Nombungo F
FAN 1 2 3 4 5 6 71 72 7 8 9 10 11 12
C C FAN
T OACE101(R) R OACE101(R) R T
A
U P P U
S
C C
S S T
P R 0 R 0 P DCM-652-F
A A 4
I P 3 P 3 I
U X X U
F F
73/10 13/7 74/1 DCM-652-A DCM-652-A
1 2 3 4 5 6 7 8 9 10 11 12
0 2 01
Master- OSN 9800 M24:TO Nombungo Master- OSN 9800 M24:TO Nombungo
PIU PIU EFI PIU PIU PIU PIU EFI PIU PIU
100 101 102 103 104 105 106 100 101 102 103 104 105 106
FAN FAN
N T N T
C C C C
2 2 2 2
13 14 15 16 17 18 X X 19 22 23 24 13 14 15 16 17 18 X X 19 22 23 24
1 1 1 1
P P P P
M OACE1 6 6 M OACE1 6 6
06(T) D 06(T) D
4 A O 4 A O
4 4
8 OACE1 S P 8 OACE1 S P
8 8
V 06(R) T M V 08(R) T M
- -
- 4 8 - 4 8
DAPXF E DAPXF E
E E
1 2 3 4 5 6 71 72 7 8 9 10 11 12 1 2 3 4 5 6 71 72 7 8 9 10 11 12
FAN FAN
Lubango-1 Quilemba-1
Master- OSN 1800 V Pro TO Repeater Master- OSN 1800 V Pro TO Repeater
13 DAP PA30 OACE101 14 13 DAP PA30 OACE101 14
11 AT8 12 FXSO12 11 AT8 12 FXSO12
9 SLNO 10 ELOM 9 SLNO 10 ELOM
7 EGS4 8 EFS8 F 7 EGS4 8 EFS8 F
18 PIU 16 SXCH A 18 PIU 16 SXCH A
17 PIU 15 SXCH N 17 PIU 15 SXCH N
5 AUX 6 DXM 5 AUX 6 DXM
3 4 3 4
OTPS TPS OTPS TPS
1 2 1 2
Fiber Management Tray Fiber Management Tray
Master- OSN 1800 V Pro TO Namibe, Quilemba, Lubango Master- OSN 1800 V Pro TO Namibe, Quilemba, Lubango Master- OSN 1800 V Pro Master- OSN 1800 V Pro
13 DAP PA30 OACE101 14 ELOM 13 DAP PA30 OACE101 14 ELOM 13 DAP PA30 OACE101 14 13 DAP PA30 OACE101 14
11 DAP OACE101 12 11 DAP OACE101 12 SLNO 11 ELOM 12 11 AT8 12 FXSO12
9 DAP OACE101 10 9 DAP OACE101 10 9 ELOM 10 9 SLNO 10 ELOM
7 8 F 7 8 F 7 8 F 7 EGS4 8 EFS8 F
18 PIU 16 SXCH A 18 PIU 16 SXCH A 18 PIU 16 SXCH A 18 PIU 16 SXCH A
17 PIU 15 SXCH N 17 PIU 15 SXCH N 17 PIU 15 SXCH N 17 PIU 15 SXCH N
5 AUX 6 5 AUX 6 5 AUX 6 5 AUX 6 DXM
3 4 3 4 3 4 3 4
OTPS TPS
1 2 1 2 1 2 1 2
Fiber Management Tray Fiber Management Tray Fiber Management Tray Fiber Management Tray
Master- OSN 1800 V Pro TO Namibe, Quilemba, Lubango Master- OSN 1800 V Pro TO Namibe, Quilemba, Lubango Master- OSN 1800 V Pro Master- OSN 1800 V Pro
13 14 AT8 13 14 AT8 13 DAP PA30 OACE101 14 13 DAP PA30 OACE101 14
11 12 FXSO12 11 12 FXSO12 11 ELOM 12 11 AT8 12 FXSO12
9 SLNO 10 EFS8 9 10 EFS8 9 ELOM 10 9 SLNO 10 ELOM
7 SLNO 8 EGS4 F 7 SLNO 8 EGS4 F 7 8 F 7 EGS4 8 EFS8 F
18 PIU 16 SXCH A 18 PIU 16 SXCH A 18 PIU 16 SXCH A 18 PIU 16 SXCH A
17 PIU 15 SXCH N 17 PIU 15 SXCH N 17 PIU 15 SXCH N 17 PIU 15 SXCH N
5 AUX 6 DXM 5 AUX 6 DXM 5 AUX 6 5 AUX 6 DXM
3 4 3 4 3 4 3 4
OTPS TPS OTPS TPS OTPS TPS
1 2 1 2 1 2 1 2
Fiber Management Tray Fiber Management Tray Fiber Management Tray Fiber Management Tray
ODCM04 ODCM06
ODCM06 ODCM06 ODCM06 ODCM06
ODCM04 ODCM06
Master- OSN 1800 V Pro Master- OSN 1800 V Pro Master- OSN 1800 V Pro
13 DAP PA30 OACE101 14 ELOM 13 DAP OACE101 14 13 DAP OACE101 14
11 AT8 12 FXSO12 11 AT8 12 FXSO12 11 AT8 12 FXSO12
9 SLNO 10 SL16Q 9 SLNO 10 SLNO 9 SLNO 10 SLNO
7 EGS4 8 EFS8 F 7 EGS4 8 EFS8 F 7 EGS4 8 EFS8 F
18 PIU 16 SXCH A 18 PIU 16 XCS A 18 PIU 16 XCS A
17 PIU 15 SXCH N 17 PIU 15 XCS N 17 PIU 15 XCS N
5 AUX 6 DXM 5 AUX 6 DXM 5 AUX 6 DXM
3 4 3 4 3 4
OTPS TPS OTPS TPS OTPS TPS
1 2 1 2 1 2
Fiber Management Tray Fiber Management Tray Fiber Management Tray
ODCM06 ODCM06
ODCM06 ODCM06
Optical
19 inch Rack
6in1
Ponder ETSI Rack
OSN 9800 M24 6 in 1
MS-OTN 1+1 /2+2 63A
(PDH/PKT/SDH/OTN)
Unique real split in the industry On-demand power supply
Liquid OTN
4.8T 10T B2B
Liquid OTN line
1+1 mode 1:3 mode Cluster
board
TDM
TDM tributary
board
Packet
OTN
TDM
ODU
OSN 1800 V Pro: 5 U MS-OTN
➢ 2.8T OTN/720G PKT PKT PKT
tributary
λ1
➢ 160G HO/20G LO SDH VC PKT
board