You are on page 1of 44

Electrode Product Catalog

Self-Shielded Flux-Cored Electrodes

www.lincolnelectric.com
About The Lincolnx
Electric Companyx
Lincoln’s Innershield® Wires
Lincoln Electric is the world’s leading Lincoln Electric is the Worldwide Leader in
Self-Shielded Flux-Cored (FCAW-S) Wire
manufacturer of welding equipment and A half century ago, Lincoln Electric changed the welding industry by
consumables. Our focus is on helping introducing the first self-shielded flux-cored wire. Vast improvements in
welding efficiency and quality were achieved, and Innershield® quickly
companies make their welding earned a reputation as an efficient alternative to stick welding.
operations more effective, more
Today, almost 50 years of Innershield® design and manufacturing
efficient, more profitable. We are
experience give every pound of Innershield® wire industry leading
dedicated to two equally important quality and performance.
goals: exceptional quality and
When Fabricators Think of Self-Shielded Flux-Cored Wire –
exceptional service. Our field support They Think Innershield®
Lincoln Electric has developed a reputation among fabricators as the
team –– with hundreds of field sales
leader in self-shielded flux-cored wire design, manufacture, and
engineers and thousands of innovation. Many industries rely on Innershield® for their most crucial
applications, including: structural, transportation, offshore, and marine.
knowledgeable and responsive Lincoln
For the portability of stick electrode and the productivity of wire electrode
distributors in countries all over the – welding fabricators choose Lincoln’s Innershield® Flux-Cored Wire.
world –– is the largest in the industry.
Proprietary Manufacturing Process
Innovative thinking. A quality, service- Lincoln Electric created and developed proprietary equipment to perfect
first attitude. Fresh approaches to the manufacture of this innovative product. Lincoln’s superior inspection
process helps you improve your quality and efficiency.
design, manufacturing, and packaging.
Worldwide strength. Here’s how our manufacturing process gives you the most consistent,
high-quality wire:
Choose Lincoln. • Proprietary techniques for inspecting incoming raw steel ensure the
chemistry of each coil.
• Steel is graded according to chemical composition and matched to
the most appropriate finished product.
• Steel chemistries are held to extremely tight tolerances to ensure
consistency in mechanical properties and arc performance.
• Fluxes are inspected and monitored to ensure a consistent blend of
chemical elements.
• Moisture levels are monitored throughout processing, and lubricants
are carefully selected to provide the lowest moisture content.

All this results in high quality, consistency, and unparalleled performance


from your Innershield® wire.

Innershield ® Wire
2 www.lincolnelectric.com
Self Shielded, Flux-Cored Wires

Contents Page
Wire Selection
Guide . . . . . . . . . . . . . . . . . . . . 4-7
High Speed Single
ISO 9001 and 14001 Certified Pass Welding . . . . . . . . . . . . . 8-13
Lincoln Electric is ISO 9001 and 14001 certified
and Innershield® is manufactured to standards for All-Position
environmental and quality management systems. Welding with
The result is a wire of consistently superior quality No Impact Properties . . . . . . 14-17
– time after time. All-Position
Welding with
FEMA 353 and AWS D1.8 Impact Properties . . . . . . . . 18-25
Many Innershield® electrodes meet lot waiver requirements for
FEMA 353 and AWS D1.8 welding codes, including Innershield® Flat and Horizontal
NR-311 Ni, NR-305, NR-232 and NR-233. These electrodes have Welding with
been tested in accordance with both codes and are capable of Impact Properties . . . . . . . . 26-29
depositing weld metal that delivers minimum CVN properties of
Flat and Horizontal
54 J at 21°C (40 ft•lbf at 70°F) at low and high heat input levels.
Welding with
A minimum of three lots of each electrode have been tested in
No Impact Properties . . . . . . 30-33
accordance to these guidelines and meet the lot waiver
specifications in AWS D1.8. FEMA 353 and AWS D1.8 certificates Pipe Fabrication . . . . . . . . . . 34-37
are available upon request and accessible online through
www.lincolnelectric.com/d1.8. Packaging . . . . . . . . . . . . . . . . . 38
Agency Approvals . . . . . . . . . . . 39
AWS Storing FCAW-S
D 1.8
Structural Welding Code
Electrodes . . . . . . . . . . . . . . . . . 40
Lincoln Electric
Seismic Supplement
Sales Offices . . . . . . . . . . . . . . . 43

Important Information On Our Website


Consumable AWS Certificates:
http://www.lincolnelectric.com/products/certificates/

Material Safety Data Sheets (MSDS):


http://www.lincolnelectric.com/product/msds/

ANSI Z49.1, E205 Safety Booklet, and other Arc


Welding Safety Materials:
http://www.lincolnelectric.com/community/safety/

D1.8 Resource Center:


http://www.lincolnelectric.com/D1.8

Safe Practices Article:


http://www.lincolnelectric.com/knowledge/articles/content/lenstaybl.asp

Innershield ® Wire
3 www.lincolnelectric.com
INNERSHIELD® WIRE SELECTION GUIDE

LOW TEMPERATURE IMPACT PROPERTIES

Diameter
Name AWS Classification in. (mm)
All Position
NR® -203MP E71T-8J 0.068 (1.7)
5/64 (2.0)
NR-203 Nickel (1%) E71T8-Ni1 5/64 (2.0)
NR-232 E71T-8 0.068 (1.7)
0.072 (1.8)
5/64 (2.0)
NR-233 E71T-8 1/16 (1.6)
0.072 (1.8)
5/64 (2.0)
Flat and Horizontal
NR-305 E70T-6 5/64 (2.0)
3/32 (2.4)
NR-311 Ni E70T-7-K2 5/64 (2.0)
3/32 (2.4)
7/64 (2.8)

AWS
HIGH DEPOSITION WITH NO LOW D 1.8
Structural Welding Code
TEMPERATURE IMPACT PROPERTIES Seismic Supplement

Diameter
Name AWS Classification in. (mm)
Flat and Horizontal
NR-311 E70T-7 5/64 (2.0) FEMA 353 AND AWS D1.8 COMPLIANT
3/32 (2.4)
Diameter
7/64 (2.8) Name AWS Classification in. (mm)
NS-3M E70T-4 5/64 (2.0) Flat and Horizontal
3/32 (2.4) NR-311-Ni E70T-7-K2 3/32 (2.4)
0.120 (2.8) NR-305 E70T-6 3/32 (2.4)

All Position
NR-232 E71T-8 0.068 (1.7)
SINGLE PASS ONLY WITH NO LOW 0.072 (1.8)
TEMPERATURE IMPACT PROPERTIES 5/64 (2.0)
Diameter NR-233 E71T-8 1/16 (1.6)
Name AWS Classification in. (mm) 0.072 (1.8)
Flat and Horizontal 5/64 (2.0)
NR-5 E70T-3 3/32 (2.4)
0.0120 (3.0)
NR-131 E70T-10 3/32 (2.4)
NR-152 E71T-14 0.062 (1.6) GENERAL FABRICATION WITH NO LOW
0.068 (1.7) TEMPERATURE IMPACT PROPERTIES
Diameter
Name AWS Classification in. (mm)
NR-211-MP E71T-11 0.030 (0.8)
0.035 (0.9)
PIPE FABRICATION
0.045 (1.1)
Diameter 0.068 (1.7)
Name AWS Classification in. (mm) 5/64 (2.0)
All Position 3/32 (2.4)
NR-207 E71T8-K6 0.068 (1.7) NR-212 E71TG-G 0.045 (1.1)
5/64 (2.0) 0.068 (1.7)
NR-208-H E91T8-G-H8 5/64 (2.0) 5/64 (2.0)

Innershield ® Wire
4 www.lincolnelectric.com
INNERSHIELD® WIRE SELECTION GUIDE

AWS Classification of Self-Shielded


Flux-Cored (Tubular) Wires

E71T-8 H16
Electrode

Tensile Strength X 10 ksi


0 = Flat, Horizontal
Position 1= All Position

Flux-Cored (tubular) electrode

Slag system, usability


and performance capabilities

Hydrogen Level:
H8 = less than 8 mL/100 g
H16 = less than 16 mL/100 g

Position of Welding, Polarity, and Application Requirements

AWS Welding
Classification Position(1) Current Application(2)

E70T-3 H and F DC+ S

E70T-4 H and F DC+ M

E70T-6 H and F DC+ M

E70T-7 H and F DC- M

E71T-8 H,F,VU,OH DC- M

E70T-10 H and F DC- S

E71T-11 H,F,VD,OH DC- M

E71T-14 H,F,VD,OH DC- S

E71T-G VU, OH Not Specified M

(1) (2)
H = Horizontal position S = Single pass only
F = Flat position M = Single or Multiple pass
OH = Overhead position
VU = Vertical-Up position
VD = Vertical-Down position

Innershield ® Wire
5 www.lincolnelectric.com
INNERSHIELD® WIRE SELECTION GUIDE

Electrode AWS Recommended General Page


Name Classification Positions Description No.

High Speed Single Pass Welding Wires

Innershield® NR-5 E70T-3 Flat & Innershield® NR-5 is designed for high speed single pass 8-9
Horizontal welding applications. It is recommended for flat and
horizontal positions with maximum steel thickness up to
4.8 mm (3/16 in.). For high productivity welding on thin
gauge material – choose Innershield® NR-5.

Innershield® NR-131 E70T-10 Flat & Innershield® NR-131 is designed for high deposition rates 10-11
Horizontal at high speeds. It is recommended for single pass welding
on material thicknesses of 2.8 mm (0.110 in.) or greater. For
both single and twin arc welding applications and automatic
roundabout positions – choose Innershield® NR-131.

Innershield® NR-152 E71T-14 All Position Innershield® NR-152 is designed for high speed welding 12-13
of specialty coated steels. It is recommended for single
pass welding on material thicknesses from 0.8 to 4.8 mm
(0.030 to 3/16 in.). For excellent arc characteristics on
galvanized or other coated steels – choose
Innershield® NR-152.

All Position Welding Wires with No Impact Properties

Innershield® NR-211-MP E71T-11 All Position Innershield® NR-211-MP is a versatile wire suitable for 14-15
all-position welding of light gauge or thin plate. It is
recommended for maximum plate thicknesses in the range
of 7.9 mm (5/16 in.) to 12.7 mm (1/2 in.). For an easy to use
general fabrication wire – choose Innershield® NR-211-MP.

Innershield® NR-212 E71TG-G All Position Innershield® NR-212 is designed with the same arc 16-17
characteristics of NR-211-MP, but for use on a larger range
of applications. It is recommended for single or multiple
pass welding on up to 19 mm (3/4 in.) thicknesses. For
smooth arc performance on a wide variety of applications
– choose Innershield® NR-212.

All Position Welding Wires with Impact Properties

Innershield® NR-203MP E71T-8J All Position Innershield® NR-203MP is designed to handle poor fit-up 18-19
on heavy wall tubes and gaps up to 9.5 mm (3/8 in.) with
6.4 mm (1/4 in.) offset. It is recommended for all position
welding on unlimited plate thicknesses. For a FCAW-S
electrode with impact properties capable of exceeding
27 J (20 ft•lbf) at -40°C (-40°F) and operability on materials
with poor fit-up – choose Innershield® NR-203MP.

Innershield® NR-203 E71T8-Ni1 All Position Innershield® NR-203 Nickel (1%) is designed to produce a 20-21
Nickel (1%) nickel bearing weld deposit with impact properties capable
of exceeding 27 J (20 ft•lbf) at -29°C (-20°F). It handles
poor fit-up in the vertical up position and welds gaps up to
9.5 mm (3/8 in.). For nickel bearing weld deposits and color
matching on weathering steels – choose Innershield®
NR-203 Nickel 1%.

Innershield® NR-232 E71T-8 All Position Innershield® NR-232 is designed for high deposition, 22-23
out-of-position welding for structural fabrication in seismic
AWS zones. It is recommended for single or multiple pass
D 1.8
Structural Welding Code welding of 4.8 mm (3/16 in.) and heavier carbon steel. For
Seismic Supplement

a high deposition FCAW-S wire with impact properties


capable of exceeding 27 J (20 ft•lbf) at -29°C (-20°F)
– choose Innershield® NR-232.

Innershield ® Wire
6 www.lincolnelectric.com
INNERSHIELD® WIRE SELECTION GUIDE

Electrode AWS Recommended General Page


Name Classification Positions Description No.

All Position Welding Wires with Impact Properties

Innershield® NR-233 E71T-8 All Position Innershield® NR-233 is a good choice for training or 24-25
novice welders while also meeting the mechanical property
AWS requirements listed in AWS D1.8. It is recommended for
D 1.8
Structural Welding Code
Seismic Supplement vertical up and overhead fillet and groove welds. For easy
out-of-position operability and impact properties capable
of exceeding 27 J (20 ft•lbf) at -29°C (-20°F) – choose
Innershield® NR-233.

Flat and Horizontal Welding Wires with Impact Properties

Innershield® NR-305 E70T-6 Flat & Innershield® NR-305 is designed for in-position, high 26-27
(1) (1) Horizontal deposition welding on carbon steel. It is recommended
AWS
D 1.8 in single or multiple pass, automatic and semiautomatic
Structural Welding Code
Seismic Supplement welding. For impact properties capable of exceeding
27 J (20 ft•lbf) at -29°C (-20°F) and excellent operator
appeal – choose Innershield® NR-305.

Innershield® NR-311 Ni E70T-7-K2 Flat & Innershield® NR-311 Ni is designed to provide a nominal 28-29
(1) (1) E80T-G-K2 Horizontal 1.5% nickel weld deposit with high deposition rates and
AWS
D 1.8 fast travel. It is recommended for flat and horizontal
Structural Welding Code
Seismic Supplement positions in single and multiple pass welding. For impact
properties capable of exceeding 27 J (20 ft•lbf) at -29°C
(-20°F) – choose Innershield® NR-311 Ni.

Flat and Horizontal Welding Wires with No Impact Properties

Innershield® NR-311 E70T-7 Flat & Innershield® NR-311 is designed for high deposition rates 30-31
Horizontal and fast travel speeds. It is recommended for fillet, lap and
butt welds on 3.2 mm (1/8 in.) and thicker steel, including
some low alloy steels in applications without impact
strength requirements. For high deposition rates, easy slag
removal and good bead shape – choose Innershield® NR-311.

Innershield® NS-3M E70T-4 Flat & Innershield® NS-3M is designed for very high deposition 32-33
Horizontal rates and increased resistance to hydrogen cracking and
porosity on steel containing sulfur or contaminates. It is
recommended for single or multiple pass welding on carbon
steel and some low alloy steels in applications without
impact strength requirements. For high deposition on less
than ideal welding surfaces – choose Innershield® NS-3M.

Cross Country Pipe Fabrication Welding Wires

Innershield® NR-207 E71T8-K6 All Position Innershield® NR-207 is designed for vertical down, hot, 34-35
fill and cap passes on standard cross-country pipelines and
arctic grade pipe. It is recommended for API Pipe Grades
X42 up to undermatching X70. For pipe welding up to X70
pipe – choose Innershield® NR-207.

Innershield® NR-208-H E91T8-G-H8 All Position Innershield® NR-208-H is designed to create high strength 36-37
weld deposits with yield strength test results exceeding
minimum AWS requirements. It is recommended for API
Pipe Grade X80. For up to X80 pipe welding applications
– choose Innershield® NR-208-H.

(1) Only 3/32 in. (2.4 mm) diameter is recommended for FEMA 353 and AWS D1.8 applications.

Note: All Innershield® wires are recommended for use with constant voltage (CV) power sources. To estimate ESO, subtract 1/4 in. (6.4 mm) from CTWD.

Innershield ® Wire
7 www.lincolnelectric.com
Innershield NR-5
®

High Speed Single Pass Welding Wire


(AWS E70T-3)
Innershield® NR-5 is designed for high speed single pass welding applications. It is recommended for
flat and horizontal positions with maximum steel thickness up to 4.8 mm (3/16 in.). For high productivity
welding on thin gauge material – choose Innershield® NR-5.

Key Features Welding Positions


• High travel speeds – Up to 4.3 m (170 in.) per minute. Flat and Horizontal
• Excellent protection of weld metal – Increased resistance
to porosity.
• Consistent bead appearance – Ideal for robotic welding Conformance
applications. AWS A5.20/A5.20M: 2005 E70T-3
ASME SFA-5.20 E70T-3

Typical Applications Maximum Plate Thickness


• 3 o’clock welding positions. Diameters - in. (mm) Maximum Plate Thickness - in. (mm)
3/32 (2.4), 0.120 (3.0) 3/16 (4.8)
• 100% penetration on welds with copper back-up.
• Sheet or thin gauge metal.
Warning: NR-5 is NOT recommended for welding multiple
• Propane cylinders. passes.
• Robotics and hard automation.

DIAMETERS/PACKAGING

600 lb (272.2 kg) 600 lb (272.2 kg)


Diameter Speed-Feed® Speed-Feed®
in. (mm) Drum Reel

3/32 (2.4) ED012699 ED012701


0.120 (3.0) ED012698

MECHANICAL PROPERTIES(1) - As Required per AWS A5.20/A5.20M: 2005


Transverse
Tensile Strength Longitudinal Hardness
MPa (ksi) Bend Test Rockwell B

Requirements
AWS E70T-3 480 (70) 180° over 3/4 in. Radius
min. No openings exceeding 1/8 in. —

Typical Performance 505 - 560 Passed 99


(75 - 80)

Innershield ® Wire
8 www.lincolnelectric.com
Innershield NR-5
®

High Speed Single Pass Welding Wire


(AWS E70T-3)

DEPOSIT COMPOSITION(1) - As Required per AWS A5.20/A5.20M: 2005

%C %Mn %Si %S %P %Al %Ti

Requirements
AWS E70T-3 Not Specified

Typical Performance(2) 0.17 - 0.22 0.95 - 1.11 0.34 - 0.40 0.008 - 0.02 0.01 - 0.02 0.07 - 0.12 0.40 - 0.49

TYPICAL OPERATING PROCEDURES

Diameter Approx.
Polarity Wire Feed Speed Voltage Current Melt-Off Rate Deposition Rate Efficiency
CTWD m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

3/32 in. (2.4 mm) 2.5 (100) 22-23 500 4.5 (9.9) 3.5 (7.8) 77
DC+ 3.8 (150) 23-34 435 6.7 (14.8) 5.6 (12.3) 83
32 mm (1 1/4 in.) 5.1 (200) 24-25 510 9.0 (19.8) 7.7 (16.9) 85
6.4 (250) 25-26 575 11.2 (24.7) 9.7 (21.4) 87

0.120 in. (3.0 mm) 3.3 (130) 22-23 500 8.2 (18.0) 7.6 (16.7) 93
DC+ 4.2 (165) 23-24 600 10.4 (23.0) 9.5 (20.9) 91
32 mm (1 1/4 in.) 6.5 (205) 24-25 700 12.9 (28.5) 11.6 (25.6) 90
6.5 (255) 25-26 800 16.1 (35.5) 14.3 (31.5) 90

(1) See test results disclaimer on pg. 42. (2) Chemistry of single pass welds are highly dependent upon base metal chemistry and dilution. Analysis shown are for information purposes only.

Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

Innershield ® Wire
9 www.lincolnelectric.com
Innershield NR-131
®

High Speed Single Pass Welding Wire


(AWS E70T-10)
Innershield® NR-131 is designed for high deposition rates at high speeds. It is recommended for single
pass welding on material thicknesses of 2.8 mm (0.110 in.) or greater. For both single and twin arc
welding applications and automatic roundabout positions – choose Innershield® NR-131.

Key Features Welding Positions


• Fast travels speeds and high deposition rates – Increased Flat and Horizontal
welding productivity.
• Maximum penetration – On fillet and lap joints.
Conformance
• Flat bead profile on butt welds – Quick and easy post weld
clean up. AWS A5.20/A5.20M: 2005 E70T-10
ASME SFA-5.20 E70T-10
• Joins dissimilar plate thickness – Even heat distribution for
penetration without burn through.
Warning: NR-131 is NOT recommended for multiple pass
welding.
Typical Applications
Single Arc:
• 3.2 mm (1/8 in.) and 4.8 mm (3/16 in.) fillet welds with travel
speeds up to 2.5 m/min (100 in/min.).
Twin Arc:
• 6.4 mm (1/4 in.) and 7.9 mm (5/16 in.) fillet welds with travel
speeds up to 1.9 m/min (75 in/min.).
• Sheet metal.
• Automotive.

DIAMETERS/PACKAGING

600 lb (272.2 kg)


Diameter Speed-Feed®
in. (mm) Reel

3/32 (2.4) ED012163

MECHANICAL PROPERTIES(1) - As Required per AWS A5.20/A5.20M: 2005


Transverse
Tensile Strength Longitudinal Hardness
MPa (ksi) Bend Test Rockwell B

Requirements
AWS E70T-10 480 (70) 180˚ over 3/4 in. Radius
min. No openings exceeding 1/8 in. —

Typical Performance 505 - 565 Passed 90


(75 - 80)

Innershield ® Wire
10 www.lincolnelectric.com
Innershield NR-131
®

High Speed Single Pass Welding Wire


(AWS E70T-10)

DEPOST COMPOSITION(1) - As Required per AWS A5.20/A5.20M: 2005

%C %Mn %Si %S %P %Al

Requirements
AWS E70T-10 Not Specified

Typical Performance(2) 0.22 - 0.26 0.42 - 0.65 0.20 - 0.27 0.005 - 0.007 0.007 - 0.02 1.18 - 1.49

TYPICAL OPERATING PROCEDURES

Diameter Approx.
Polarity Wire Feed Speed Voltage Current Melt-Off Rate Deposition Rate Efficiency
CTWD m/min (in./min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

3.8 (150) 25-26 390 6.5 (14.3) 5.3 (11.6) 81


3/32 in. (2.4 mm) 5.1 (200) 25-27 490 8.6 (19.0) 7.1 (15.6) 82
Single Arc, DC- 6.4 (250) 26-27 570 10.8 (23.7) 8.9 (19.6) 82
38 mm (1 1/2 in.) 8.9 (350) 26-28 720 15.0 (33.1) 33.6 (27.6) 83
10.8 (425) 27-28 810 18.2 (40.1) 15.2 (33.6) 83

3.3 (130) 25-26 550 11.1 (24.5) 8.1 (17.9) 72


3/32 in. (2.4 mm) 4.4 (175) 26-27 740 15.0 (33.0) 12.0 (26.4) 79
Twinarc, DC- 5.7 (225) 26-28 910 19.3 (42.5) 15.8 (34.8) 81
44 mm (1 3/4 in.) 7.0 (275) 27-29 1030 23.5 (51.9) 19.1 (42.0) 80
8.3 (325) 28-30 1090 27.9 (61.4) 21.9 (48.2) 78
(1) See test results disclaimer on pg. 42. (2) Chemistry of single pass welds are highly dependent upon base metal chemistry and dilution. Analysis shown are for information purposes only.

Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

Innershield ® Wire
11 www.lincolnelectric.com
Innershield NR-152
®

High Speed Single Pass Welding Wire


(AWS E71T-14)
Innershield® NR-152 is designed for high speed welding of specialty coated steels. It is recommended
for single pass welding on material thicknesses from 0.8 to 4.8 mm (0.030 to 3/16 in.). For excellent arc
characteristics on galvanized or other coated steels—choose Innershield® NR-152.

Key Features Welding Positions


• Soft, consistent arc – Less burn-through on thin materials. All Position
• Porosity resistant – On galvanized or other coated steel.
• Excellent overlapping capabillities – Even on roundabouts.
Conformance
• Ideal for robotic applications – Clean electrode burn-off for
AWS A5.20/A5.20M: 2005 E71T-14
minimal end clipping.
ASME SFA-5.20 E71T-14

Typical Applications Maximum Plate Thickness


• Spot or short intermittent welds on 0.8 mm (0.031 in.) and Diameters - in. (mm) Maximum Plate Thickness - in. (mm)
thicker sheet metal. 0.062 (1.6), 0.068 (1.7) 3/16 (4.8)
• Continuous welds on 1.2 mm (0.048 in.) and thicker sheet metal
in the 1.0 - 1.5 m/min (40 - 60 in./min) travel speed.
Warning: NR-152 is NOT recommended for welding multiple
• Continuous welds on galvanized or zinc coated carbon steel in
passes.
the 0.7 - 1.0 m/min (30 - 40 in./min) travel speed.
Note: The preferred drag angle is 15°, however, NR-152 is
• Automotive. capable of welding at zero drag angle, facilitating easy fixturing
• Transportation. in automatic applications.

DIAMETERS/PACKAGING

500 lb (226.8 kg)


Diameter 50 lb (22.6 kg) Speed-Feed®
in. (mm) Coil Drum

0.062 (1.6) ED012185 ED024301


0.068 (1.7) ED012186

MECHANICAL PROPERTIES(1) - As Required per AWS A5.20/A5.20M: 2005


Transverse
Tensile Strength Longitudinal Hardness
MPa (ksi) Bend Test Rockwell B

Requirements
AWS E71T-14 480 (70) 180° over 3/4 in. Radius
min. No openings exceeding 1/8 in. —

Typical Performance 480 - 550 Passed 93


(70 - 80)

Innershield ® Wire
12 www.lincolnelectric.com
Innershield NR-152
®

High Speed Single Pass Welding Wire


(AWS E71T-14)

DEPOSIT COMPOSITION(1) - As Required per AWS A5.20/A5.20M: 2005

%C %Mn %Si %S %P %Al

Requirements
AWS E71T-14 Not Specified

Typical Performance(2) 0.25 - 0.30 0.83 - 1.04 0.20 - 0.23 0.006 - 0.01 0.005 - 0.02 1.08 - 1.38

TYPICAL OPERATING PROCEDURES

Diameter Approx.
Polarity Wire Feed Speed Voltage Current Melt-Off Rate Deposition Rate Efficiency
CTWD m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

0.8 (30) 13-14 90 0.5 (1.3) 0.5 (1.2) 92


0.062 in. (1.6 mm) 1.0 (40) 14-15 115 0.8 (1.8) 0.7 (1.6) 88
DC- 1.3 (50) 15-16 140 0.9 (2.2) 0.9 (2.0) 90
16 mm (5/8 in.) 1.8 (70) 16-17 185 1.4 (3.1) 1.3 (2.8) 90
2.8 (110) 19-20 265 2.1 (4.8) 2.0 (4.4) 91

0.8 (30) 13-14 68 0.7 (1.6) 0.6 (1.4) 87


0.068 in. (1.7 mm) 1.0 (40) 13-14 95 0.9 (2.2) 0.9 (1.9) 86
DC- 1.3 (50) 14-15 120 1.2 (2.7) 1.1 (2.4) 88
19 mm (3/4 in.) 1.5 (60) 15-16 145 1.4 (3.3) 1.3 (2.9) 87
2.0 (80) 16-17 190 1.9 (4.4) 1.8 (3.9) 88
2.8 (110) 20-21 240 2.7 (6.0) 2.4 (5.4) 90

(1) See test results disclaimer on pg. 42. (2) Chemistry of single pass welds are highly dependent upon base metal chemistry and dilution. Analysis shown are for information purposes only.

Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

Innershield ® Wire
13 www.lincolnelectric.com
Innershield NR-211-MP
®

All Position Welding Wire with No Impact Properties


(AWS E71T-11)
Innershield® NR-211-MP is a versatile wire suitable for all-position welding of light gauge or thin plate. It
is recommended for maximum plate thicknesses in the range of 7.9 mm (5/16 in.) to 12.7 mm (1/2 in.).
For an easy to use general fabrication wire – choose Innershield® NR-211-MP.

Key Features Welding Positions


• Versatile application use – All position welding capability for a All Position
wide range of base material thickness. Note: 3/32 in. (2.4 mm) diameter is not recommended for
• Low spatter – High operator appeal and good bead out-of-position welding.
appearance.
• Easy slag removal – Higher producivity for multiple pass Conformance
welding. AWS A5.20/A5.20M: 2005 E71T-11
• Fast freezing characteristics – Accommodates poor fit-up. ASME SFA-5.20 E71T-11
ABS E71T-11
CWB W48 E491T-11-H16
DB EN 758 T42 Z S N 1
Typical Applications TUV EN 758 T42 A S N 1

• 3 o’clock welding positions.


• Welding application requiring copper back-up. Maximum Plate Thickness
• Sheet or thin gauge metal. Diameters - in. (mm) Maximum Plate Thickness - in. (mm)
0.030 (0.8), 0.035 (0.9), 5/16 (7.9)
• Propane cylinders.
0.045 (1.1)
• Robotics and hard automation.
0.068 (1.7), 5/64 (2.0), 1/2 (12.7)
3/32 (2.4)

DIAMETERS/PACKAGING

1 lb (0.5 kg) 1 lb (0.5 kg) 14 lb (6.4 kg)


Plastic Spool Plastic Spool Coil
Diameter 5 lb (2.3 kg) 10 lb (4.5 kg) 10 lb (4.5 kg) 56 lb (25.4 kg) 25 lb (11.3 kg) 50 lb (22.6 kg)
in. (mm) Master Carton Master Carton Plastic Spool Master Carton Steel Spool Coil

0.030 (0.8) ED031448


0.035 (0.9) ED027641 ED016354 ED030637
0.045 (1.1) ED016363 ED030638
0.068 (1.7) ED012506 ED030641 ED012507
5/64 (2.0) ED012508 ED030645 ED012509
3/32 (2.4) ED013869

MECHANICAL PROPERTIES(1) - As Required per AWS A5.20/A5.20M: 2005

Yield Strength(2) Tensile Strength Elongation Hardness


MPa (ksi) MPa (ksi) (%) Rockwell B

Requirements(3)
AWS E71T-11 400 (58) 480 - 655 20 —
min. (70 - 95) min.

Typical Performance 435 - 475 605 - 645 22 - 25 89 - 92


(63 - 69) (88 - 94)

Innershield ® Wire
14 www.lincolnelectric.com
Innershield NR-211-MP
®

All Position Welding Wire with No Impact Properties


(AWS E71T-11)

DEPOSIT COMPOSITION(1) - As Required per AWS A5.20/A5.20M: 2005

%C %Mn %Si %S %P %Al

Requirements
AWS E71T-11 0.30 max. 1.75 max. 0.60 max. 0.03 max. 0.03 max. 1.8 max.

Typical Performance 0.23 - 0.26 0.57 - 0.66 0.17 - 0.26 ≤0.01 ≤0.01 1.3 - 1.6

TYPICAL OPERATING PROCEDURES

Diameter Approx.
Polarity Wire Feed Speed Voltage Current Melt-Off Rate Deposition Rate Efficiency
CTWD m/min (in./min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

1.3 (50) 13 - 14 30 0.2 (0.5) 0.2 (0.4) 81


2.5 (100) 13 - 14 60 0.5 (1.1) 0.4 (0.8) 75
0.030 in. (0.8 mm)
3.8 (150) 14 - 15 80 0.7 (1.6) 0.6 (1.2) 78
DC-
5.1 (200) 14 - 15 100 1.0 (2.1) 0.8 (1.7) 81
13 mm (1/2 in.)
6.4 (250) 15 - 16 130 1.2 (2.6) 1.0 (2.1) 80
7.6 (300) 18 - 19 140 1.4 (3.2) 1.2 (2.6) 81

1.3 (50) 14 - 15 30 0.4 (0.8) 0.3 (0.7) 81


0.035 in. (0.9 mm) 1.8 (70) 15 - 16 60 0.5 (1.2) 0.5 (1.0) 83
DC- 2.8 (110) 16 - 17 115 0.7 (1.6) 0.6 (1.3) 78
16 mm (5/8 in.) 3.8 (150) 17 - 18 130 1.0 (2.2) 0.8 (1.7) 78
5.1 (200) 18 - 19 155 1.4 (3.0) 1.1 (2.5) 84

1.8 (70) 15-16 120 0.7 (1.6) 0.5 (1.1) 69


0.045 in. (1.1 mm)
2.3 (90) 16-17 140 1.0 (2.2) 0.8 (1.7) 77
DC-
2.8 (110) 17-18 160 1.2 (2.7) 1.0 (2.3) 85
16 mm (5/8 in.)
3.3 (130) 18-19 170 1.5 (3.2) 1.2 (2.7) 84

1.0 (40) 15-16 125 1.0 (2.1) 0.8 (1.7) 81


0.068 in. (1.7 mm)
1.9 (75) 18-19 190 1.8 (4.0) 1.5 (3.4) 85
DC-
3.3 (130) 20-21 270 3.2 (7.0) 2.8 (6.1) 88
19 - 32 mm (3/4 - 1 1/4 in.)
4.4 (175) 23-24 300 4.3 (9.4) 3.8 (8.4) 89

1.3 (50) 16-17 180 1.6 (3.5) 1.3 (2.9) 83


5/64 in. (2.0 mm)
1.9 (75) 18-19 235 2.4 (5.3) 2.0 (4.5) 85
DC-
3.0 (120) 20-21 290 3.8 (8.4) 3.4 (7.4) 88
19 - 32 mm (3/4 - 1 1/4 in.)
4.1 (160) 22-23 325 5.1 (11.2) 4.5 (10.0) 89

1.3 (50) 16-17 245 2.3 (5.0) 1.9 (4.2) 84


3/32 in. (2.4 mm)
1.9 (75) 19-20 305 3.4 (7.5) 2.9 (6.4) 85
DC-
2.5 (100) 20-21 365 4.5 (10.0) 3.9 (8.7) 87
19 - 32 mm (3/4 - 1 1/4 in.)
3.3 (130) 22-23 400 5.9 (12.9) 5.1 (11.3) 88
(1) See test results disclaimer on pg. 42. (2) Measured with 0.2% offset.
(3) The strength and elongation properties reported were obtained from a 2.8 mm (0.505 in.) tensile specimen artificially aged at 104°C (220°F) for 48 hours, as permitted by AWS A5.20-05. A naturally aged tensile specimen may
take months to achieve the specified properties. See AWS A5.20-05, paragraph A8.3. The time required for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry, the metallurgical
structure of the weld deposit and other factors.

Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

Innershield ® Wire
15 www.lincolnelectric.com
Innershield NR-212
®

All Position Welding Wire with No Impact Properties


(AWS E71TG-G)
Innershield® NR-212 is designed with the same arc characteristics of NR-211-MP, but for use on a larger
range of applications. It is recommended for single or multiple pass welding on up to 19 mm (3/4 in.)
thicknesses. For smooth arc performance on a wide variety of applications—choose Innershield® NR-212.

Key Features Welding Positions


• Accommodates many different base materials – A wide All Position
range of carbon steels, including coated steels.
• Fast freeze characteristics – Accommodate poor fit-up.
Conformance
AWS A5.29/A5.29M: 2005 E71TG-G
ASME SFA-5.20 E71TG-G
Typical Applications CWB E71TG-G
• Single or multiple pass welds.
• Welding of truck bodies, tanks, hoppers, racks and
scaffolding. Maximum Plate Thickness
• General fabrication. Diameters - in. (mm) Maximum Plate Thickness - in. (mm)
• Robotic welding applications. 0.045 (1.1), 0.068 (1.7), 3/4 (19.1)
5/64 (2.0)

DIAMETERS/PACKAGING

14 lb (6.4 kg)
Coil
Diameter 10 lb (4.5 kg) 56 lb (25.4 kg) 25 lb (11.3 kg) 50 lb (22.6 kg)
in. (mm) Plastic Spool Master Carton Steel Spool Coil

0.045 (1.1) ED026090 ED030639


0.068 (1.7) ED027803 ED030642
5/64 (2.0) ED027794 ED030646 ED026858

MECHANICAL PROPERTIES(1) - As Required per AWS A5.29/A5.29M: 2005

Yield Strength(2) Tensile Strength Elongation Hardness


MPa (ksi) MPa (ksi) (%) Rockwell B

Requirements(3)
AWS E71TG-G 400 (58) 480 - 655 20 —
min. (70 - 95) min.

Typical Performance 440 - 505 575 - 605 24 - 28 89 - 92


(64 - 74) (84 - 88)

Innershield ® Wire
16 www.lincolnelectric.com
Innershield NR-212
®

All Position Welding Wire with No Impact Properties


(AWS E71TG-G)

DEPOSIT COMPOSITION(1) - As Required per AWS A5.29/A5.29M: 2005

%C %Mn* %Si %S %P %Ni* %Cr* %Mo* %V* %Al

Requirements
AWS E71TG-G Not Specified 0.50 min 1.00 max. 0.030 max. 0.030 max. 0.50 min. 0.30 min. 0.20 min. 0.10 min. 1.8 max.

Typical Performance 0.06 - 0.11 0.84 - 1.55 0.20 - 0.33 ≤0.003 0.006 - 0.009 1.02 - 1.15 0.02 - 0.04 ≤0.02 — 1.3 - 1.6

NOTE: In order to meet the alloy AWS requirements of the G group, the weld deposit needs to have the minimum, as specified in the table, of only one of the elements marked with an asterisk.

TYPICAL OPERATING PROCEDURES

Diameter Approx.
Polarity Wire Feed Speed Voltage Current Melt-Off Rate Deposition Rate Efficiency
CTWD m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

1.4 (55) 14-15 75 0.5 (1.3) 0.5 (1.1) 84


0.045 in. (1.1 mm) 1.8 (70) 15-16 90 0.7 (1.6) 0.6 (1.4) 87
DC- 2.3 (90) 16-17 115 1.0 (2.1) 0.8 (1.8) 85
16 mm (5/8 in.) 2.8 (110) 17-18 135 1.2 (2.6) 1.0 (2.2) 84
3.3 (130) 18-19 155 1.4 (3.1) 1.2 (2.6) 83
4.1 (160) 19-20 170 1.6 (3.5) 1.4 (3.0) 85

1.5 (60) 16-17 145 1.4 (3.1) 1.1 (2.4) 77


0.068 in. (1.7 mm) 1.9 (75) 17-18 180 1.7 (3.8) 1.4 (3.2) 84
DC- 2.3 (90) 18-19 200 2.0 (4.5) 1.7 (3.8) 84
25 mm (1 in.) 3.0 (120) 19-20 230 2.7 (6.0) 2.3 (5.2) 86
3.8 (150) 20-21 255 3.3 (7.4) 2.9 (6.4) 86
4.4 (175) 22-23 275 3.9 (8.7) 3.4 (7.5) 86

1.5 (60) 16-17 200 1.7 (3.8) 1.5 (3.3) 86


5/64 in. (2.0 mm) 1.9 (75) 18-19 225 2.1 (4.7) 1.8 (4.1) 87
DC- 2.3 (60) 19-20 245 2.6 (5.7) 2.3 (5.0) 87
25 mm (1 in.) 2.8 (110) 20-21 275 3.2 (7.1) 2.8 (6.2) 87
3.3 (130) 21-23 300 3.7 (8.3) 3.3 (7.3) 87
3.8 (150) 22-23 325 4.3 (9.6) 3.8 (8.4) 87

(1) See test results disclaimer on pg. 42. (2) Measured with 0.2% offset.
(3) The strength and elongation properties reported were obtained from a 2.85 mm (0.505 in.) tensile specimen artificially aged at 104°C (220°F) for 48 hours, as permitted by AWS A5.29-05. A naturally aged tensile specimen may
take months to achieve the specified properties. See AWS A5.29-05. The time required for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry, the metallurgical structure of
the weld deposit and other factors.

Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

Innershield ® Wire
17 www.lincolnelectric.com
Innershield NR-203MP
®

All Position Welding Wire with Impact Properties


(AWS E71T-8J)
Innershield® NR-203MP is designed to handle poor fit-up on heavy wall tubes and gaps up to 9.5 mm
(3/8 in.) with 6.4 mm (1/4 in.) offset. It is recommended for all position welding on unlimited plate
thicknesses. For a FCAW-S electrode with impact properties capable of exceeding 27 J (20 ft•lbf)
at -40°C (-40°F) and operability on materials with poor fit-up – choose Innershield® NR-203MP.

Key Features Welding Positions


• Fast freezing slag – For all position welding. All Position
• Excellent wash-in – Reduced tendency to trap slag on
narrow weld joints.
• Root bead capability – Weld in grooves without backup bars.
Conformance
• Handles poor fit-up – On heavy wall tubes and gaps up
AWS A5.20/A5.20M: 2005 E71T-8J
to 9.5 mm (3/8 in.) with 6.4 mm (1/4 in.) offset.
ASME SFA-5.20 E71T-8J
ABS 3YSA
Lloyd’s 3S-3YS-H15
Typical Applications DNV III YMS (H10)
BV SA3YMH
• General plate fabrication, including bridge fabrication, hull plate
GL 3YSH15
and stiffener welding on ships and barges.
CWB W48 E491T-8
• Storage tanks.
• Structural fabrication.
• Offshore welding in TKY joints.

DIAMETERS/PACKAGING

14 lb (6.4 kg)
Coil
Diameter 56 lb (25.4 kg) 25 lb (11.3 kg)
in. (mm) Master Carton Steel Spool

0.068 (1.7) ED030640


5/64 (2.0) ED021604

MECHANICAL PROPERTIES(1) - As Required per AWS A5.20/A5.20M: 2005

Charpy V-Notch
Yield Strength(2) Tensile Strength Elongation J (ft•lbf) Hardness
MPa (ksi) MPa (ksi) (%) @ -29°C (-20°F) @ -40°C (-40°F) Rockwell B

Requirements(3)
AWS E71T-8J 400 480 - 655 22 Not 27 —
(58) min. (70 - 95) min. min. Specified (20) min.
Typical Performance 415 - 440 510 - 545 29 - 33 75 - 203 68 - 224 82 - 87
(60 - 64) (74 - 79) (55 - 150) (50 - 165)

Innershield ® Wire
18 www.lincolnelectric.com
Innershield NR-203MP
®

All Position Welding Wire with Impact Properties


(AWS E71T-8J)

DEPOSIT COMPOSITION(1) - As Required per AWS A5.20/A5.20M: 2005

%C %Mn %Si %S %P %Al

Requirements
AWS E71T-8J 0.30 max. 1.75 max. 0.60 max. 0.03 max. 0.03 max. 1.8 max.

Typical Performance 0.04 - 0.07 1.35 - 1.47 0.22 - 0.32 ≤0.01 ≤0.01 0.8 - 1.0

TYPICAL OPERATING PROCEDURES

Diameter Approx.
Polarity Wire Feed Speed Voltage Current Melt-Off Rate Deposition Rate Efficiency
CTWD m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

1.8 (70) 16-17 145 1.5 (3.3) 1.0 (2.3) 69


0.068 in. (1.7 mm) 2.3 (90) 18-19 180 1.9 (4.2) 1.5 (3.2) 76
DC- 3.0 (120) 20-21 225 2.5 (5.6) 2.0 (4.3) 76
25 mm (1 in.) 3.5 (140) 21-22 255 2.9 (6.4) 2.2 (4.8) 75
3.8 (150) 23-24 265 3.1 (6.8) 2.3 (5.1) 75

1.3 (50) 16-17 130 1.4 (3.1) 0.9 (1.9) 61


5/64 in. (2.0 mm) 1.8 (70) 18-19 180 2.0 (4.3) 1.3 (2.9) 67
DC- 2.3 (90) 19-20 220 2.5 (5.6) 1.9 (4.2) 75
25 mm (1 in.) 2.8 (110) 20-21 260 3.1 (6.8) 2.4 (5.3) 77
3.0 (120) 21-22 280 3.4 (7.4) 2.7 (5.9) 79
3.5 (140) 22-23 310 3.9 (8.7) 3.1 (6.8) 79

(1) See test results disclaimer on pg. 42. (2) Measured with 0.2% offset.
(3) The strength and elongation properties reported were obtained from a 2.8 mm (0.505 in.) tensile specimen artificially aged at 104°C (220°F) for 48 hours, as permitted by AWS A5.20-05. A naturally aged tensile specimen may take
months to achieve the specified properties. See AWS A5.20-05, paragraph A8.3. The time required for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry, the metallurgical structure of the
weld deposit and other factors.

Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

RADIOGRAPHIC GUIDELINES
The opacity of NR-203MP slag to x-ray is such that slag inclusions will normally appear lighter than the weld. Voids will normally appear darker than the weld.
When using gamma-radiography, slag inclusions and voids will normally appear darker than the weld. Improved x-ray film readability usually can be
obtained by slight over-exposure at an excitation potential consistent with good x-ray practice, but not over 240 KV. For detailed information on welding
techniques, procedure adjustments, and their effects on weld appearance and quality, request publication C3.2400 in.Innershield® Electrode - Semiautomatic
Production Welding Guide in..

Innershield ® Wire
19 www.lincolnelectric.com
Innershield NR-203 Nickel (1%)
®

All Position Welding Wires with Impact Properties


(AWS E71T8-Ni1)
Innershield® NR-203 Nickel (1%) is designed to produce a nickel bearing weld deposit with impact prop-
erties capable of exceeding 27 J (20 ft•lbf) at -29°C (-20°F). It handles poor fit-up in the vertical
up position and welds gaps up to 9.5 mm (3/8 in.). For nickel bearing weld deposits and color
matching on weathering steels—choose Innershield® NR-203 Nickel 1%.

Key Features Welding Positions


• Use on weathering steels – Where color match is important. All Position
• Produces nickel bearing weld deposit – Nominally
0.80 - 1.10%.
Conformance
• Handles poor fit-up – In the vertical up position, gaps up to
9.5 mm (3/8 in.). AWS A5.29/A5.29M: 2005 E71T8-Ni1
ASME SFA-5.29 E71T8-Ni1
• Root bead capability – Open groove welding without backup ABS 3YSA
bars. Lloyd’s 3S-3YS-H15
DNV III YMS (H10)
CWB E71T-8-Ni1
Typical Applications DB EN 758 T42 3 1 Ni Y N
TUV EN 758 T42 3 1 Ni Y N
• Roundabout groove welds on heavy wall tubular construction.
• Offshore welding applications.
• Bridges and other outdoor structural components made from
weathering steel.
• Structural fabrication.
• NACE applications.

DIAMETERS/PACKAGING

14 lb (6.4 kg)
Coil
Diameter 56 lb (25.4 kg) 50 lb (22.6 kg)
in. (mm) Master Carton Coil

5/64 (2.0) ED012385 ED012386

MECHANICAL PROPERTIES(1) - As Required per AWS A5.29/A5.29M: 2005

Charpy V-Notch
Yield Strength(2) Tensile Strength Elongation J (ft•lbf) Hardness
MPa (ksi) MPa (ksi) (%) @ -29°C (-20°F) Rockwell B

Requirements(3)
AWS E71T8-Ni1 400 (58) 480 - 620 20 27 (20) —
min. (70 - 90) min. min.
Typical Performance 450 - 480 545 - 575 27 - 32 81 - 156 86 - 90
As-welded (65 - 70) (79 - 83) (60 - 115)

Innershield ® Wire
20 www.lincolnelectric.com
Innershield NR-203 Nickel (1%)
®

All Position Welding Wires with Impact Properties


(AWS E71T8-Ni1)

DEPOSIT COMPOSITION(1) - As Required per AWS A5.29/A5.29M: 2005

%C %Mn %Si %S %P %Ni %Cr %Mo %V %Al

Requirements
AWS E71T8-Ni1 0.12 max. 1.50 max. 0.80 max. 0.030 max. 0.030 max. 0.80 - 1.10 0.15 max. 0.35 max. 0.05 max. 1.8 min.

Typical Performance 0.05 - 0.07 1.10 - 1.22 0.30 - 0.33 ≤0.010 0.005 - 0.008 0.89 - 1.05 0.02 - 0.03 0.01 - 0.02 ≤0.01 0.8 - 1.0

TYPICAL OPERATING PROCEDURES

Diameter Approx.
Polarity Wire Feed Speed Voltage Current Melt-Off Rate Deposition Rate Efficiency
CTWD m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

1.3 (50) 16-17 145 1.4 (3.0) 1.0 (2.3) 76


5/64 in. (2.0 mm) 1.8 (70) 18-19 195 2.0 (4.3) 1.5 (3.3) 76
DC- 2.3 (90) 19-20 240 2.5 (5.5) 2.0 (4.3) 78
25 mm (1 in.) 2.8 (110) 20-21 275 3.0 (6.7) 2.4 (5.3) 79
3.0 (120) 21-22 290 3.3 (7.3) 2.6 (5.8) 79
3.5 (140) 22-23 310 3.9 (8.5) 3.0 (6.9) 81

(1) See test results disclaimer on pg. 42. (2) Measured with 0.2% offset.
(3) The strength and elongation properties reported were obtained from a 2.8 mm (0.505 in.) tensile specimen artificially aged at 104°C (220°F) for 48 hours, as permitted by AWS A5.29-05. A naturally aged tensile specimen
may take months to achieve the specified properties. See AWS A5.29-05. The time required for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry, the metallurgical
structure of the weld deposit and other factors.

Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

Innershield ® Wire
21 www.lincolnelectric.com
Innershield NR-232
®

All Position Welding Wire with Impact Properties AWS


D 1.8
(AWS E71T-8) Structural Welding Code
Seismic Supplement

Innershield® NR-232 is designed for high deposition, out-of-position welding for structural fabrication
in seismic zones. It is recommended for single or multiple pass welding of 4.8 mm (3/16 in.) and heavier
carbon steel. For a high deposition FCAW-S wire with impact properties capable of exceeding 27 J
(20 ft•lbf) at -29°C (-20°F) – choose Innershield® NR-232.

Key Features Welding Positions


• Meets FEMA and D1.8 lot waiver requirements – Test All Position
results available at www.lincolnelectric.com/d1.8.
• Impact properties tested at -29°C (-20°F) – Exceeds
Conformance
minimum requirement.
AWS A5.20/A5.20M: 2005 E71T-8
• Fast freezing slag system – Supports high deposition rates ASME SFA-5.20 E71T-8
on out-of-position welding. ABS 3YSA
• Easy slag removal – In tight grooves. Lloyd’s 3S-3YS-H15
DNV III YMS (H15)
BV SA3YMH
Typical Applications GL 3YSH10
CWB W48 E491T-8
• Structural fabrication, including those subject to seismic DB EN 758 T42 3 Y N 2
requirements. TUV EN 758 T42 3 Y N 2
• General plate fabrication including bridges. FEMA 353
AWS D1.8
• Hull plate and stiffener welding on ships and barges.
NOTE: Innershield® NR-232 has a Military Grade Classification of MIL-71T-8AS for 0.068 in. (1.7 mm)
• Machinery parts, tanks, hoppers, racks and scaffolding. and 0.072 in. (1.8 mm) diameters only.

DIAMETERS/PACKAGING

13.5 lb (6.1 kg) 13.5 lb (6.1 kg)


Coil Coil Vaccum Sealed Foil Bag
Diameter 54 lb (24.5 kg) 54 lb (24.5 kg) 25 lb (11.3 kg) 25 lb (11.3 kg) 50 lb (22.6 kg)
in (mm) Master Carton Hermetically Sealed Pail Steel Spool Plastic Spool Coil

0.068 (1.7) ED012518 ED032531 ED030643 ED032533 ED012519


0.072 (1.8) ED012522 ED030232 ED030644 ED030949 ED012523
5/64 (2.0) ED012525 ED032532 ED030647 ED032534 ED012526

MECHANICAL PROPERTIES(1) - As Required per AWS A5.20/A5.20M: 2005

Charpy V-Notch
Yield Strength(2) Tensile Strength Elongation J (ft•lbf) Hardness
MPa (ksi) MPa (ksi) (%) @ -29°C (-20°F) Rockwell B

Requirements(3)
AWS E71T-8 400 (58) 480 - 655 22 27 (20) —
min. (70 - 95) min. min.

Typical Performance 460 - 520 575 - 615 25 - 31 47 - 75 87 - 90


(66 - 75) (83 - 89) (35 - 55)

Innershield ® Wire
22 www.lincolnelectric.com
Innershield NR-232
®

All Position Welding Wire with Impact Properties


(AWS E71T-8)

DEPOSIT COMPOSITION(1) - As Required per AWS A5.20/A5.20M: 2005

%C %Mn %Si %S %P %Al

Requirements
AWS E71T-8 0.30 max. 1.75 max. 0.60 max. 0.03 max. 0.03 max. 1.8 max.

Typical Performance 0.16 - 0.18 0.61 - 0.72 0.26 - 0.33 ≤0.01 ≤0.01 0.5 - 0.8

TYPICAL OPERATING PROCEDURES

Diameter Approx.
Polarity Wire Feed Speed Voltage Current Melt-Off Rate Deposition Rate Efficiency
CTWD m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

2.8 (110) 18-19 195 2.3 (5.0) 1.8 (3.9) 78


3.3 (130) 19-21 225 2.8 (6.2) 2.0 (4.6) 74
0.068 in. (1.1 mm) 3.8 (150) 19-21 250 3.2 (7.1) 2.4 (5.3) 75
DC- 4.3 (170) 20-22 270 3.5 (7.8) 2.8 (6.1) 78
19 - 32 mm (3/4 - 1 1/4 in.) 5.0 (195) 23-24 300 4.3 (9.4) 3.2 (7.0) 74
6.4 (250) 23-24 350 5.4 (11.8) 4.0 (9.0) 76
7.4 (320) 25-27 400 6.9 (15.2) 5.2 (11.4) 75

2.0 (80) 16-18 130 1.8 (4.0) 1.5 (3.3) 83


0.072 in. (1.8 mm) 3.5 (140) 18-21 225 3.1 (6.8) 2.5 (5.5) 81
DC- 3.9 (155) 19-22 240 3.3 (7.2) 2.7 (6.0) 83
19 - 32 mm (3/4 - 1 1/4 in.) 4.3 (170) 20-23 255 3.6 (8.0) 2.9 (6.5) 81
6.4 (250) 22-24 315 5.3 (11.7) 4.3 (9.6) 82
7.4 (290) 23-25 350 6.2 (13.6) 5.0 (11.0) 81

1.5 (60) 16-17 145 1.7 (3.7) 1.2 (2.7) 73


5/64 in. (2.0 mm) 2.9 (115) 19-20 260 3.2 (7.0) 2.5 (5.5) 78
DC- 3.0 (120) 19-20 270 3.3 (7.3) 2.6 (5.7) 78
19 - 32 mm (3/4 - 1 1/4 in.) 3.3 (130) 20-21 285 3.5 (7.8) 2.8 (6.2) 79
4.6 (180) 22-23 365 5.0 (10.9) 3.9 (8.7) 80

(1)
See test results disclaimer on pg. 42. (2) Measured with 0.2% offset.
(3)
The strength and elongation properties reported were obtained from a 2.8 mm (0.505 in.) tensile specimen artificially aged at 104°C (220°F) for 48 hours, as permitted by AWS A5.20-05. A naturally aged tensile
specimen may take months to achieve the specified properties. See AWS A5.20-05, paragraph A8.3. The time required for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry,
the metallurgical structure of the weld deposit and other factors.
NOTE: FEMA and AWS D1.8 structural steel seismic supplement test data can be found on this product at www.lincolnelectric.com.

Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

FEMA 353 & AWS D1.8


This electrode has been tested in accordance with FEMA 353 & AWS D1.8 - Structural Welding Code – Seismic Supplement and is capable of depositing weld metal that delivers minimum
CVN properties of 54 J at 21°C (40 ft•lbf at 70°F) at low and high heat input levels. As required by the AWS classification, it meets a minimum CVN of 27 J at -29°C (20 ft•lbf at -20°F), when
tested in accordance with AWS 5.20-05. This electrode will also deposit metal that will meet the requirements for H16 as tested according to AWS A4.3. FEMA and AWS D1.8 certificates are
available upon request.

Innershield ® Wire
23 www.lincolnelectric.com
Innershield NR-233
®

All Position Welding Wire with Impact Properties AWS


D 1.8
(AWS E71T-8) Structural Welding Code
Seismic Supplement

Innershield® NR-233 is a good choice for training or novice welders while also meeting the
mechanical property requirements listed in AWS D1.8. It is recommended for vertical up and
overhead fillet and groove welds. For easy out-of-position operability and impact properties
capable of exceeding 27 J (20 ft•lbf) at -29°C (-20°F) – choose Innershield® NR-233.

Key Features Welding Positions


• Meets FEMA 353 and AWS D1.8 lot waiver requirements – All Position
Test results available at www.lincolnelectric.com/d1.8.
• Impact properties tested at -29°C (-20°F) – Exceed minimum
requirement. Conformance
• Easy to operate – Accommodates low operator skill in training. AWS A5.20/A5.20M: 2005 E71T-8
ASME SFA-5.20 E71T-8
ABS E71T-8
FEMA 353
AWS D1.8
Typical Applications
• Seismic structural steel erection.
• General structural steel erection.
• Ship and barge fabrication. Note: Innershield® K126 Gun Assembly requires a specific gun tube
• Vertical up and overhead fillets and groove welds. assembly for better wire feeding of NR-233 wire.

DIAMETERS/PACKAGING

12.5 lb (5.7 kg)


Plastic Spool Vaccum Sealed Foil Bag
Diameter 50 lb (22.6 kg) 25 lb (11.3 kg) 25 lb (11.3 kg)
in. (mm) Master Carton Plastic Spool Plastic Spool

1/16 (1.6) ED030933 ED030934 ED031576


0.072 (1.8) ED031030 ED031577
5/64 (2.0) ED033039 ED033024

MECHANICAL PROPERTIES(1) - As Required per AWS A5.20/A5.20M: 2005

Charpy V-Notch
Yield Strength(2) Tensile Strength Elongation J (ft•lbf) Hardness
MPa (ksi) MPa (ksi) (%) @-29ºC (-20ºF) Rockwell B

Requirements(4)
AWS E71T-8 400 (58) 480 - 655 22 27 (20) —
min. (70 - 95) min. min.

Typical Performance 435 - 455 575 - 595 26 - 29 34 - 54 87 - 89


(63 - 66) (83 - 86) (25 - 40)

Innershield ® Wire
24 www.lincolnelectric.com
Innershield NR-233
®

All Position Welding Wire with Impact Properties


(AWS E71T-8)

DEPOSIT COMPOSITION(1) - As Required per AWS A5.20/A5.20M: 2005

%C %Mn %Si %S %P %Al

Requirements
AWS E71T-8 0.30 max. 1.75 max. 0.60 max. 0.03 max. 0.03 max. 1.8 max.

Typical Performance 0.15 - 0.20 0.61 - 0.65 0.17 - 0.21 ≤0.03 ≤0.01 0.5 - 0.6

TYPICAL OPERATING PROCEDURES

Diameter Approx.
Polarity Wire Feed Speed Voltage Current Melt-Off Rate Deposition Rate Efficiency
CTWD m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

3.8 (150) 17-19 220 2.4 (5.3) 1.9 (4.2) 80


1/16 in. (1.6 mm) 5.1 (200) 19-21 245 3.2 (7.1) 2.5 (5.4) 76
DC- 6.4 (250) 21-23 270 4.0 (8.9) 3.0 (6.6) 74
25 mm (1 in.) 7.6 (300) 23-25 295 4.7 (10.4) 3.5 (7.7) 75
8.9 (350) 25-27 315 5.6 (12.3) 4.3 (9.4) 77

2.5 (100) 17-18 184 2.0 (4.5) 1.6 (3.6) 80


0.072 in. (1.8 mm) 3.8 (150) 18-19 250 3.1 (6.7) 2.5 (5.4) 80
DC- 5.1 (200) 20-21 295 4.0 (8.9) 3.2 (7.1) 81
19 - 25 mm (3/4 - 1 in.) 6.4 (250) 22-23 330 5.1 (11.2) 4.0 (8.9) 79
7.6 (300) 23-24 355 6.1 (13.4) 4.8 (10.6) 79

2.3 (90) 18-19 210 2.2 (4.9) 1.8 (4.1) 82


5/64 in. (2.0 mm) 3.2 (125) 19-20 260 3.2 (7.0) 2.6 (5.6) 81
DC- 3.8 (150) 20-21 300 3.8 (8.4) 3.0 (6.7) 80
19 - 25 mm (3/4 - 1 in.)(3) 5.1 (200) 21-22 340 5.1 (11.2) 4.1 (9.0) 81
6.1 (240) 22-23 380 6.1 (13.3) 4.9 (10.8) 81
(1)
See test results disclaimer on pg. 42. (2) Measured with 0.2% offset. (3) CTWD for 5/64 in. (2.0 mm) for 5.1 and 6.1 m/min (200 and 240 in/min.) is 25 - 32 mm (1 - 1 1/4 in.).
(4)
The strength and elongation properties reported were obtained from a 2.8 mm (0.505 in.) tensile specimen artificially aged at 220°F (104°C) for 48 hours, as permitted by AWS A5.20-05. A naturally aged tensile
specimen may take months to achieve the specified properties. See AWS A5.20-05, paragraph A8.3. The time required for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry,
the metallurgical structure of the weld deposit and other factors.
NOTE: For horizontal welding, subtract 1 volt. NOTE: FEMA and AWS D1.8 structural steel seismic supplement test data can be found on this product at www.lincolnelectric.com.

Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

FEMA 353 & AWS D1.8


This electrode has been tested in accordance with FEMA 353 & AWS D1.8 - Structural Welding Code – Seismic Supplement and is capable of depositing weld metal that delivers minimum
CVN properties of 54 J at 21°C (40 ft•lbf at 70°F) at low and high heat input levels. As required by the AWS classification, it meets a minimum CVN of 27 J at -29°C (20 ft•lbf at -20°F), when
tested in accordance with AWS 5.20-05. This electrode will also deposit metal that will meet the requirements for H16 as tested according to AWS A4.3. FEMA and AWS D1.8 certificates are
available upon request.

Innershield ® Wire
25 www.lincolnelectric.com
Innershield NR-305
®

Flat and Horizontal Welding Wire with Impact Properties (1)


AWS
(1)

D 1.8
(AWS E70T-6) Structural Welding Code
Seismic Supplement

Innershield® NR-305 is designed for in-position, high deposition welding on carbon steel. It is
recommended in single or multiple pass, automatic and semiautomatic welding. For impact properties
capable of exceeding 27 J (20 ft•lbf) at -29°C (-20°F) and excellent operator appeal – choose
Innershield® NR-305.

Key Features Welding Positions


• 3/32 in. (2.4 mm) diameter meets FEMA 353 and AWS D1.8 Flat and Horizontal
lot waiver requirements –Test results available at
www.lincolnelectric.com/d1.8.
• High deposition rates – In the flat and horizontal positions. Conformance
• High efficiency electrode – Smooth arc and low spatter AWS A5.20/A5.20M: 2005 E70T-6
ASME SFA-5.20 E70T-6
levels.
ABS 2YSA / E70T-6
• Welds on lightly rusted or primed plate. DNV II YMS
DB EN 758 T42 O W N 3
TUV EN 758 T42 O W N 3
Typical Applications FEMA 353 3/32 in. (2.4 mm) only
AWS D1.8 3/32 in. (2.4 mm) only
• Structural fabrication, including those subject to seismic
requirements [3/32 in. (2.4 mm) only].
• General plate fabrication including bridges and offshore rigs.
• Shipyards
• Stiffener welding on ships and barges.
• Welding over tack welds made with stick electrodes.

DIAMETERS/PACKAGING

Vacuum Sealed Foil Bag Vaccum Sealed Foil Bag


Diameter 25 lb (11.3 kg) 25 lb (11.3 kg) 50 lb (22.6 kg) 50 lb (22.6 kg)
in. (mm) Steel Spool Plastic Spool Coil Plastic Spool

5/64 (2.0) ED030648


3/32 (2.4) ED030971 ED012593 ED030005

MECHANICAL PROPERTIES(2) - As Required per AWS A5.20/A5.20M: 2005

Charpy V-Notch
Yield Strength(3) Tensile Strength Elongation J (ft•lbf) Hardness
MPa (ksi) MPa (ksi) (%) @ -29°C (-20°F) Rockwell B

Requirements(4)
AWS E70T-6 400 (58) 480 - 655 22 27 (20) —
min. (70 - 95) min. min.
Typical Performance 465 - 535 565 - 620 24 - 28 27 - 41 88 - 93
As-welded (68 - 77) (82 - 90) (20 - 30)

Innershield ® Wire
26 www.lincolnelectric.com
Innershield NR-305
®

Flat and Horizontal Welding Wire with Impact Properties


(AWS E70T-6)

DEPOSIT COMPOSITION(2) - As Required per AWS A5.20/A5.20M: 2005

%C %Mn %Si %S %P %Al

Requirements
AWS E70T-6 0.30 max. 1.75 max. 0.60 max. 0.03 max. 0.03 max. 1.8 max.

Typical Performance 0.06 - 0.09 1.08 - 1.57 0.20 - 0.27 ≤0.01 ≤0.01 0.9 - 1.1

TYPICAL OPERATING PROCEDURES

Diameter Approx.
Polarity Wire Feed Speed Voltage Current Melt-Off Rate Deposition Rate Efficiency
CTWD m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

4.4 (175) 21-23 295 8.5 (10.5) 4.0 (8.8) 84


5/64 in. (2.0 mm) 5.6 (220) 22-24 345 6.0 (13.3) 5.0 (11.1) 83
DC+ 6.6 (260) 23-25 385 7.1 (15.7) 5.9 (13.1) 83
35 - 51 mm (1 3/8 - 2 in.) 7.1 (280) 24-26 404 7.7 (16.9) 6.4 (14.2) 84
7.6 (300) 25-27 420 8.2 (18.1) 6.9 (15.2) 84
8.3 (325) 25-27 435 8.9 (19.7) 7.4 (16.4) 83

3/32 in. (2.4 mm) 4.1 (160) 21-23 330 6.0 (13.3) 5.0 (11.0) 82
DC+ 6.1 (240) 24-26 425 9.1 (20.0) 7.6 (16.7) 83
54 mm (2 1/4 in.) 7.6 (300) 27-29 475 11.3 (25.0) 9.5 (21.0) 84
10.2 (400) 33-35 525 15.2 (33.4) 12.7 (28.0) 83

(1)
Only 3/32 in. (2.4 mm) diameter is recommended for FEMA 353 and AWS D1.8 applications. (2) See test results disclaimer on pg. 42. (3) Measured with 0.2% offset.
(4)
The strength and elongation properties reported were obtained from a 2.8 mm (0.505 in.) tensile specimen artificially aged at 104°C (220°F) for 48 hours, as permitted by AWS A5.20-05. A naturally aged tensile specimen
may take months to achieve the specified properties. See AWS A5.20-05. The time required for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry, the metallurgical
structure of the weld deposit and other factors.
NOTE: FEMA and AWS D1.8 structural steel seismic supplement test data can be found on this product at www.lincolnelectric.com.

Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

FEMA 353 & AWS D1.8


This electrode has been tested in accordance with FEMA 353 & AWS D1.8 - Structural Welding Code – Seismic Supplement and is capable of depositing weld metal that delivers minimum
CVN properties of 54 J at 21°C (40 ft•lbf at 70°F) at low and high heat input levels. As required by the AWS classification, it meets a minimum CVN of 27 J at -29°C (20 ft•lbf at -20°F), when
tested in accordance with AWS 5.20-05. This electrode will also deposit metal that will meet the requirements for H16 as tested according to AWS A4.3. FEMA and AWS D1.8 certificates are
available upon request.

Innershield ® Wire
27 www.lincolnelectric.com
Innershield NR-311 Ni
®

Flat and Horizontal Welding Wire with Impact Properties (1)


AWS
(1)

D 1.8
(AWS E70T-7-K2, E80T-G-K2) Structural Welding Code
Seismic Supplement

Innershield® NR-311 Ni is designed to provide a nominal 1.5% nickel weld deposit with high deposition
rates and fast travel. It is recommended for flat and horizontal positions in single and multiple pass
welding. For impact properties capable of exceeding 27 J (20 ft•lbf) at -29°C (-20°F) – choose
Innershield® NR-311 Ni.

Key Features Welding Positions


• 3/32 in. (2.4 mm) diameter meets FEMA 353 and AWS D1.8 Flat and Horizontal
lot waiver requirements – Test results available at
www.lincolnelectric.com/d1.8.
Conformance
• High deposition rates and fast travel speeds.
AWS A5.29/A5.29M: 2005 E70T-7-K2 / E80T-G-K2
• Produces a nominal 1.5% nickel deposit – Impact properties ASME SFA-5.29 E70T-7-K2 / E80T-G-K2
tested at -29°C (-20°F). ABS 2YSA
• Color match – On weathering steel applications. Lloyd’s 2S-2YS
DNV II YMS
BV SA2YM
GL 2YS
Typical Applications DB EN 758 T42 2 1 / 5Ni WN5
• Fillet and lap welds. TUV EN 758 T42 2 1 / 5Ni WN5
FEMA 353 3/32 in. (2.4 mm) only
• Horizontal butt welds such as column-to-column structural
AWS D1.8 3/32 in. (2.4 mm) only
connections.
• Deep groove welds.
• Square edge butt welds.
• Structural fabrication, including applications involving seismic
requirements.
• Weathering steels.

DIAMETERS / PACKAGING

Vacuum Sealed Foil Bag


Diameter 25 lb (11.3 kg) 50 lb (22.6 kg) 50 lb (22.6 kg)
in. (mm) Steel Spool Coil Coil

5/64 (2.0) ED030650


3/32 (2.4) ED017822 ED032530
7/64 (2.8) ED017824

MECHANICAL PROPERTIES(2) - As Required per AWS A5.29/A5.29M: 2005

Charpy V-Notch
Yield Strength(3) Tensile Strength Elongation J (ft•lbf) Hardness
MPa (ksi) MPa (ksi) (%) @-29°C (-20°F) Rockwell B

Requirements(4)
AWS E70T-7-K2 400 (58) 480 - 620 20 27 (20) —
AWS E80T-G-K2 min. (70 - 90) min. min.

Typical Performance 470 - 515 575 - 615 27 - 30 41 - 87 88 - 93


(68 - 75) (83 - 89) (30 - 65)

Innershield ® Wire
28 www.lincolnelectric.com
Innershield NR-311 Ni
®

Flat and Horizontal Welding Wire with Impact Properties


(AWS E70T-7-K2, E80T-G-K2)

DEPOSIT COMPOSITION(2) - As Required per AWS A5.29/A5.29M: 2005

%C %Mn %Si %S %P %Ni %Cr %Mo %V %Al

Requirements
AWS E70T-7-K2 0.15 0.50 - 1.75 0.80 0.030 0.030 1.00 - 2.00 0.15 0.35 0.05 1.8
AWS E80T-G-K2 max. max. max. max. max. max. max. max.

Typical Performance 0.06 - 0.08 1.25 - 1.40 0.18 - 0.22 ≤0.003 0.005 - 0.008 1.29 - 1.56 0.03 - 0.04 ≤0.03 — 1.0 - 1.3

TYPICAL OPERATING PROCEDURES

Diameter Approx.
Polarity Wire Feed Speed Voltage Current Melt-Off Rate Deposition Rate Efficiency
CTWD m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

2.5 (100) 21-23 170 2.5 (5.5) 1.8 (3.9) 70


5/64 in. (2.0 mm) 3.3 (130) 24-26 205 3.3 (7.2) 2.4 (5.2) 72
DC- 4.1 (160) 25-27 235 4.0 (8.8) 2.9 (6.5) 73
32 mm (1 1/4 in.) 5.1 (200) 26-28 270 5.0 (11.0) 3.8 (8.3) 75
6.1 (240) 27-29 295 6.1 (13.3) 4.5 (10.0) 75

1.9 (75) 20-22 200 2.8 (6.2) 1.9 (4.2) 67


0.3/32 in. (1.3 mm) 2.5 (100) 21-23 245 3.8 (8.3) 2.7 (5.9) 71
DC- 3.1 (125) 23-25 285 4.7 (10.4) 3.4 (7.5) 72
38 mm (1 1/2 in.) 3.8 (150) 25-27 330 5.7 (12.5) 4.1 (9.1) 72
4.4 (175) 26-28 365 6.6 (14.5) 4.9 (10.8) 74
5.1 (200) 27-29 390 7.6 (16.6) 5.6 (12.3) 74

2.5 (100) 22-24 310 5.2 (11.4) 3.8 (8.4) 73


7/64 in. (2.8 mm) 3.5 (140) 24-26 370 7.2 (15.8) 5.4 (11.8) 74
DC- 4.3 (170) 26-28 430 8.9 (19.5) 6.6 (14.5) 74
44.5 mm (1 3/4 in.) 5.1 (200) 28-30 470 10.4 (22.8) 7.7 (17.0) 74
6.1 (240) 29-31 520 12.4 (27.2) 9.2 (20.4) 75

(1)
Only 3/32 in. (2.4 mm) diameter is recommended for FEMA 353 and AWS D1.8 applications. (2) See test results disclaimer on pg. 42. (3) Measured with 0.2% offset.
(2)
The strength and elongation properties reported were obtained from a 2.8 mm (0.505 in.) tensile specimen artificially aged at 104°C (220°F) for 48 hours, as permitted by AWS A5.29-05. A naturally aged tensile specimen may
take months to achieve the specified properties. See AWS A5.29-05. The time required for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry, the metallurgical structure
of the weld deposit and other factors.
NOTE: FEMA and AWS D1.8 structural steel seismic supplement test data can be found on this product at www.lincolnelectric.com.

Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

FEMA 353 & AWS D1.8


This electrode has been tested in accordance with FEMA 353 & AWS D1.8 - Structural Welding Code – Seismic Supplement and is capable of depositing weld metal that delivers minimum
CVN properties of 54 J at 21°C (40 ft•lbf at 70°F) at low and high heat input levels. As required by the AWS classification, it meets a minimum CVN of 27 J at -29°C (20 ft•lbf at -20°F), when
tested in accordance with AWS 5.20-05. This electrode will also deposit metal that will meet the requirements for H16 as tested according to AWS A4.3. FEMA and AWS D1.8 certificates are
available upon request.

Innershield ® Wire
29 www.lincolnelectric.com
Innershield NR-311
®

Flat and Horizontal Welding Wire with No Impact Properties


(AWS E70T-7)
Innershield® NR-311 is designed for high deposition rates and fast travel speeds. It is recommended
for fillet, lap and butt welds on 3.2 mm (1/8 in.) and thicker steel, including some low alloy steels in
applications without impact strength requirements. For high deposition rates, easy slag removal and
good bead shape – choose Innershield® NR-311.

Key Features Welding Positions


• High deposition rates and fast travel speeds. Flat and Horizontal
• Optimal toe wash-in – Great stackability.
• Deep penetration – For thick base material applications.
Conformance
• High resistance to cracking – For welding high sulfur steels.
AWS A5.20/A5.20M: 2005 E70T-7
ASME SFA-5.20 E70T-7
ABS E70T-7
CWB W48 E492T-7
Typical Applications
• Horizontal butt welds, such as column-to-column structural
connections not subject to seismic requirements.
• General fabrication and assembly welding.

DIAMETERS/PACKAGING

14 lb (6.4 kg)
Coil
Diameter 56 lb (25.4 kg) 25 lb (11.3 kg) 50 lb (22.6 kg) 600 lb (272.2 kg) 600 lb (272.2 kg)
in. (mm) Master Carton Steel Spool Coil Speed-Feed® Reel Speed-Feed®Drum

5/64 (2.0) ED014464 ED030649 ED014459


3/32 (2.4) ED012629 ED012628
7/64 (2.8) ED012632 ED012633

MECHANICAL PROPERTIES(1) - As Required per AWS A5.20/A5.20M: 2005

Yield Strength(2) Tensile Strength Elongation Hardness


MPa (ksi) MPa (ksi) (%) Rockwell B

Requirements(3)
AWS E70T-7 400 (58) 480 - 655 22 —
min. (70 -95) min.
Typical Performance 420 - 475 600 - 645 23 - 26 88 - 92
(61 - 69) (87 - 93)

Innershield ® Wire
30 www.lincolnelectric.com
Innershield NR-311
®

Flat and Horizontal Welding Wire with No Impact Properties


(AWS E70T-7)

DEPOSIT COMPOSITION(1) - As Required per AWS A5.20/A5.20M: 2005

%C %Mn %Si %S %P %Al

Requirements
AWS E70T-7 0.30 max. 1.75 max. 0.60 max. 0.03 max. 0.03 max. 1.8 max.

Typical Performance 0.25 - 0.29 0.44 - 0.51 0.09 - 0.12 ≤0.01 ≤0.01 1.4 - 1.7

TYPICAL OPERATING PROCEDURES

Diameter Approx.
Polarity Wire Feed Speed Voltage Current Melt-Off Rate Deposition Rate Efficiency
CTWD m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

5/64 in. (2.0 mm) 2.5 (100) 20-23 190 2.9 (6.4) 2.3 (5.0) 78
DC- 4.1 (160) 24-28 275 4.7 (10.3) 3.6 (8.0) 78
38 mm (1 1/2 in.) 6.1 (240) 25-29 355 7.0 (15.4) 5.6 (12.4) 80
7.6 (300) 27-31 410 8.8 (19.3) 7.2 (15.8) 82

1.9 (75) 20-23 200 3.2 (7.0) 2.5 (5.4) 77


3/32 in. (2.4 mm) 3.4 (135) 23-26 300 5.9 (13.1) 4.6 (10.2) 78
DC- 3.8 (150) 24-27 325 6.6 (14.6) 5.2 (11.4) 78
45 mm (1 3/4 in.) 5.3 (210) 26-28 400 9.3 (20.4) 7.5 (16.5) 81
6.9 (270) 28-30 450 11.9 (26.2) 10.0 (22.0) 84

2.5 (100) 23-26 325 5.4 (12.0) 4.5 (10.0) 83


7/64 in. (2.8 mm) 3.7 (145) 25-27 400 8.1 (17.8) 6.6 (14.5) 82
DC- 4.4 (175) 26-28 450 9.8 (21.5) 8.2 (18.0) 83
45 mm (1 3/4 in.) 6.1 (240) 30-32 550 13.4 (29.5) 11.6 (25.5) 86
7.6 (300) 32-34 625 16.7 (36.9) 15.0 (33.0) 89

(1) See test results disclaimer on pg. 42. (2) Measured with 0.2% offset.
(3) The strength and elongation properties reported were obtained from a 2.8 mm (0.505 in.) tensile specimen artificially aged at 104°C (220°F) for 48 hours, as permitted by AWS A5.20-05. A naturally aged tensile
specimen may take months to achieve the specified properties. See AWS A5.20-05, paragraph A8.3. The time required for the natural aging of weld deposits is dependent upon ambient conditions,
weldment geometry, the metallurgical structure of the weld deposit and other factors.

Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

Innershield ® Wire
31 www.lincolnelectric.com
Innershield NS-3M
®

Flat and Horizontal Welding Wire with No Impact Properties


(AWS E70T-4)
Innershield® NS-3M is designed for very high deposition rates and increased resistance to hydrogen
cracking and porosity on steel containing sulfur or contaminates. It is recommended for single or
multiple pass welding on carbon steel and some low alloy steels in applications without impact strength
requirements. For high deposition on less than ideal welding surfaces – choose Innershield® NS-3M.

Key Features Welding Positions


• Extremely high deposition rates. Flat and Horizontal
• Resists cracking – On high sulfur steel.
• Resists porosity – On mildly rusty, oily or dirty plate.
• Soft, low penetrating arc – For minimal base material add Conformance
mixture. AWS A5.20/A5.20M: 2005 E70T-4
ASME SFA-5.20 E70T-4
CWB W48 E492T-4
TUV EN 14700
Typical Applications
• Open groove welds.
• Structural fabrication (with no seismic requirements).
• Machinery bases and heavy equipment repair.
• Installing wear plates.
• Multiple pass fillet and lap welds.
• Corner welds and single pass butt welds.
• 6.4 - 12.7 mm (1/4 - 1/2 in.) single pass fillet and lap welds.

DIAMETERS / PACKAGING

14 lb (6.4 kg)
Coil 600 lb (272.2 kg)
Diameter 56 lb (25.4 kg) 50 lb (22.6 kg) Speed-Feed®
in. (mm) Master Carton Coil Drum

5/64 (2.0) ED012739 ED012740


3/32 (2.4) ED012736 ED012735
0.120 (3.0) ED012732 ED012731

MECHANICAL PROPERTIES(1) - As Required per AWS A5.20/A5.20M: 2005

Yield Strength(2) Tensile Strength Elongation Hardness


MPa (ksi) MPa (ksi) (%) Rockwell B

Requirements(3)
AWS E70T-4 400 (58) 480 - 655 22 —
min. (70 - 95) min.

Typical Performance 415 - 450 580 - 620 25 - 28 87 - 91


(60 - 65) (84 - 90)

Innershield ® Wire
32 www.lincolnelectric.com
Innershield NS-3M
®

Flat and Horizontal Welding Wire with No Impact Properties


(AWS E70T-4)

DEPOSIT COMPOSITION(1)) - As Required per AWS A5.20/A5.20M: 2005

%C %Mn %Si %S %P %Al

Requirements
AWS E70T-4 0.30 max. 1.75 max. 0.60 max. 0.03 max. 0.03 max. 1.8 max.

Typical Performance 0.21 - 0.25 0.37 - 0.53 0.25 - 0.29 ≤0.01 ≤0.01 1.3 - 1.6

TYPICAL OPERATING PROCEDURES

Diameter Approx.
Polarity Wire Feed Speed Voltage Current Melt-Off Rate Deposition Rate Efficiency
CTWD m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

5/64 in. (2.0 mm) (5.1) 200 29-31 280 (5.5) 12.2 (4.6) 10.1 83
DC+ (6.1) 240 30-32 315 (6.7) 14.8 (5.5) 12.1 82
54 mm (2 1/4 in.) (6.6) 260 30-32 330 (7.3) 16.0 (6.0) 13.2 83
(7.6) 300 31-33 350 (8.4) 18.6 (6.9) 15.2 82

(2.8) 110 28-30 250 (4.6) 10.1 (3.7) 8.2 81


3/32 in. (2.4 mm) (3.8) 150 29-31 300 (6.4) 14.0 (5.3) 11.7 84
DC+ (4.7) 185 30-32 350 (7.9) 17.4 (6.6) 14.6 84
76 mm (3 in.) (5.8) 230 31-33 400 (9.8) 21.6 (8.3) 18.3 85
(7.0) 275 32-34 450 (11.8) 26.0 (10.0) 22.0 85

0.120 in. (3.0 mm) (3.5) 140 28-30 380 (9.0) 19.8 (7.0) 15.5 78
DC+ (4.4) 175 29-31 450 (11.2) 24.6 (9.1) 20.0 81
76 mm (3 in.) (5.1) 200 30-32 500 (12.7) 28.0 (10.5) 23.2 83
Electrical Stickout: (7.6) 300 31-33 550 (14.2) 31.4 (11.9) 26.2 83
2 - 3/4 in. (70 mm)

0.120 in. (3.0 mm) (5.3) 210 35-37 450 (13.2) 29.0 (11.3) 25.0 86
DC+ (6.4) 250 36-38 500 (15.6) 34.5 (13.2) 29.0 84
102 mm (4 in.) (7.6) 300 37-39 550 (18.8) 41.5 (15.4) 34.0 82
Electrical Stickout: (9.0) 355 38-40 600 (22.2) 49.0 (18.0) 39.5 81
3 - 3/4 in. (95 mm)

(1) See test results disclaimer on pg. 42. (2) Measured with 0.2% offset.
(3) The strength and elongation properties reported were obtained from a 2.8 mm (0.505 in.) tensile specimen artificially aged at 104°C (220°F) for 48 hours, as permitted by AWS A5.20-05. A naturally aged tensile
specimen may take months to achieve the specified properties. See AWS A5.20-05, paragraph A8.3. The time required for the natural aging of weld deposits is dependent upon ambient conditions,
weldment geometry, the metallurgical structure of the weld deposit and other factors.

Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

Innershield ® Wire
33 www.lincolnelectric.com
Innershield NR-207
®

Cross Country Pipe Fabrication Welding Wire


(AWS E71T8-K6)
Innershield® NR-207 is designed for vertical down, hot, fill and cap passes on standard cross-country
pipelines and arctic grade pipe. It is recommended for API Pipe Grades X42 up to undermatching X70.
For pipe welding up to X70 pipe – choose Innershield® NR-207.

Key Features Welding Positions


• Improved productivity – Over SMAW on pipeline projects. All Position
• Optimal performance – On vertical down, hot, fill and cap
passes on standard cross country and arctic grade pipelines.

Typical Applications Conformance


• Standard cross-country pipelines. AWS A5.29/A5.29M: 2005 E71T8-K6
ASME SFA-5.29 E71T8-K6
• Arctic grade pipe up to undermatched X70.
ABS E71T8-K6
DNV III YMS (H15)
BV SA3YMH
GL 2YSH15
TUV EN 758 T42 3 1Ni Y N 1 H15

DIAMETERS/PACKAGING

14 lb (6.4 kg)
Coil
Diameter 56 lb (25.4 kg)
in. (mm) Hermetically Sealed Pail

0.068 (1.7) ED016312


5/64 (2.0) ED012438

MECHANICAL PROPERTIES(1) - As Required per AWS A5.29/A5.29M: 2005

Charpy V-Notch
Yield Strength(2) Tensile Strength Elongation J (ft•lbf) Hardness
MPa (ksi) MPa (ksi) (%) @ -29°C (-20°F) Rockwell B

Requirements(3)
AWS E71T8-K6 400 (58) 480 - 620 20 27 (20) —
min. (70 - 90) min. min.

Typical Performance 415 - 445 520 - 545 29 - 33 81 - 237 84 - 87


(60 - 64) (75 - 79) (60 - 175)

Innershield ® Wire
34 www.lincolnelectric.com
Innershield NR-207
®

Cross Country Pipe Fabrication Welding Wire


(AWS E71T8-K6)

DEPOSIT COMPOSITION(1) - As Required per AWS A5.29/A5.29M: 2005

%C %Mn %Si %S %P %Ni %Cr %Mo %V %Al

Requirements
AWS E71T8-K6 0.15 max. 0.50 - 1.50 0.80 max. 0.030 max. 0.030 max. 0.40 - 1.00 0.20 max. 0.15 max. 0.05 max. 1.8 max.

Typical 0.05 - 0.07 0.87 - 0.96 0.23 - 0.27 ≤0.003 0.004 - 0.008 0.73 - 0.83 0.02 - 0.03 0.02 - 0.03 ≤0.01 0.9 - 1.1
Performance

TYPICAL OPERATING PROCEDURES

Diameter Approx.
Polarity Wire Feed Speed Voltage Current Melt-Off Rate Deposition Rate Efficiency
CTWD m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

2.0 (80) 17-18 190 1.7 (3.8) 1.3 (3.0) 79


0.068 in. (1.7 mm) 2.6 (105) 18-19 230 2.2 (5.3) 1.8 (4.0) 80
DC- 3.0 (120) 19-20 245 2.5 (5.7) 2.0 (4.5) 79
25 mm (1 in.) 3.5 (140) 21-22 275 3.0 (6.8) 2.4 (5.5) 81
4.4 (175) 21-22 295 3.6 (8.0) 2.9 (6.4) 80

1.7 (70) 17-18 205 2.0 (4.5) 1.5 (3.4) 76


5/64 in. (2.0 mm) 2.0 (80) 18-19 225 2.3 (5.1) 1.7 (3.9) 76
DC- 2.2 (90) 18-19 240 2.6 (5.8) 2.0 (4.5) 78
25 mm (1 in.) 2.7 (110) 20-21 275 3.1 (7.0) 2.4 (5.5) 79
3.3 (130) 20-21 300 3.7 (8.3) 2.9 (6.5) 78

(1) See test results disclaimer on pg. 42. (2) Measured with 0.2% offset.
(3) The strength and elongation properties reported were obtained from a 2.8 mm (0.505 in.) tensile specimen artificially aged at 104°C (220°F) for 48 hours,as permitted by AWS A5.29-05. A naturally aged tensile specimen
may take months to achieve the specified properties. See AWS A5.29-05. The time required for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry, the metallurgical
structure of the weld deposit and other factors.

Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

Innershield ® Wire
35 www.lincolnelectric.com
Innershield NR-208-H
®

Cross Country Pipe Fabrication Welding Wire


(AWS E91T8-G-H8)
Innershield® NR-208-H is designed to create high strength weld deposits with yield strength test
results exceeding minimum AWS requirements. It is recommended for API Pipe Grade X80. For up
to X80 pipe welding applications – choose Innershield® NR-208-H.

Key Features Welding Positions


• Improved productivity over SMAW – On pipeline projects. All Position
• High yield strength – Weld deposits capable of exceeding
80,000 psi.
Conformance
AWS A5.29/A5.29M: 2005 E91T8-G-H8
Typical Applications ASME SFA-5.29 E91T8-G-H8
• Standard cross-country pipelines.
• API Pipe Grade up to undermatched X80.

DIAMETERS/PACKAGING

14 lb (6.4 kg)
Coil
Diameter 56 lb (25.4 kg)
in. (mm) Hermetically Sealed Pail

5/64 (2.0) ED023366

MECHANICAL PROPERTIES(1) - As Required per AWS A5.29/A5.29M: 2005

Charpy V-Notch
Yield Strength(2) Tensile Strength Elongation J (ft•lbf) Hardness
MPa (ksi) MPa (ksi) (%) @ -29°C (-20°F) Rockwell

Requirements(3)
AWS E91T8-G-H8 538 (78) 620 - 758 17 Not —
min. (90 - 110) min. Specified

Typical Performance 555 - 600 630 - 670 24 - 27 54 - 129 91 - 95


(81 - 87) (91 - 97) (40 - 95)

Innershield ® Wire
36 www.lincolnelectric.com
Innershield NR-208-H
®

Cross Country Pipe Fabrication Welding Wire


(AWS E91T8-G-H8)

DEPOSIT COMPOSITION(1) - As Required per AWS A5.29/A5.29M: 2005

Diffusible Hydrogen
%C %Mn %Si %S %P %Ni %Cr %Mo %V %Al (mL/100g)

Requirements
AWS E91T8-G-H8 Not Specified 0.50 min. 1.00 max. 0.030 max. 0.030 max. 0.50 min. 0.30 min. 0.20 max. 0.10 min. 1.8 min. 8.0 max.

Typical 0.04 - 0.07 1.48 - 2.02 0.11 - 0.31 ≤0.003 0.004 - 0.010 0.71 - 0.98 0.02 - 0.03 ≤0.04 ≤0.01 0.9- 1.2 ≤8
Performance

TYPICAL OPERATING PROCEDURES

Diameter Approx.
Polarity Wire Feed Speed Voltage Current Melt-Off Rate Deposition Rate Efficiency
CTWD m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

1.7 (70) 16-17 195 1.8 (4.0) 1.4 (3.2) 81


5/64 in. (2.0 mm) 2.0 (80) 17-18 220 2.1 (4.6) 1.7 (3.9) 84
DC- 2.2 (90) 18-19 235 2.5 (5.4) 2.0 (4.5) 84
25 mm (1 in.) 2.7 (110) 19-20 270 2.9 (6.5) 2.4 (5.5) 85
3.3 (130) 19-20 295 3.5 (7.6) 2.9 (6.5) 85

(1)
See test results disclaimer on pg. 42. (2) Measured with 0.2% offset.
(2)
The strength and elongation properties reported were obtained from a 2.8 mm (0.505 in.) tensile specimen artificially aged at 220°F (104°C) for 48 hours,as permitted by AWS A5.29-05. A naturally aged tensile
specimen may take months to achieve the specified properties. See AWS A5.29-05. The time required for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry,
the metallurgical structure of the weld deposit and other factors.
NOTE: In order to meet the alloy requirements of the G group, the weld deposit needs to have the minimum, as specified in the table, of only one of the elements marked with an asterisk.

Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

Innershield ® Wire
37 www.lincolnelectric.com
Packaging
Lincoln Electric’s Innershield® self-shielded flux-cored wires are Packaging Shown:
available in a variety of packaging options to meet your specific 1. 10 lb. (4.5 kg) - Plastic Spool
application requirements.
2. 600 lb. (272.2 kg) - Speed-Feed® Drum
Bulk packaging includes Speed-Feed® drums and reels built to 3. 600 lb. (272.2 kg) - Speed-Feed® Reel
deliver consistent performance in conventional automation and 4. 1 lb. (0.5 kg) Plastic Spool, 5 lb. (2.3 kg)
Master Carton
robotic applications, as well as semiautomatic applications.
Speed-Feed® drums must be rotated for proper wire payoff. 5. 13.5 lb (6.1 kg) Coil, 54 lb. (24.5 kg)
Master Hermetically Sealed Pail
Small packaging configurations include spools and coils from 6. 25 lb. (11.3 kg) Steel Spool
1 - 50 lb. (0.4 - 23 kg). Several packages are available in either 7. 25 lb. (11.3 kg) - Plastic Spool with
hermetically sealed pails or vacuum sealed foil bags to meet Vaccum Sealed Foil Bag
FEMA 353 and AWS D1.8 package requirements. 8. 50 lb. (22.6 kg) - Coil

1 2 3

4 5 6 7 8

Innershield ® Wire
38 www.lincolnelectric.com
Agency Approvals
AGENCY APPROVALS(1)

FEMA 353
AWS and
Product(2) Class ABS Lloyd’s DNV BV GL CWB DB TUV AWS D1.8

NR-5 E70T-3

NR-131 E70T-10

NR-152 E71T-14

NR-211-MP E71T-11 E71T-11(3) W48 E491T-11(2) EN 758 T42 Z S N 1 EN 758 T42 A S N 1

NR-212 E71TG-G E71TG-G(3)

NR-203MP E71T-8J 3YSA(4) 3S-3YS-H15 III YMS SA3YMH 3YSH15 W48 E491T-8
(H10)

NR-203 E71T8-Ni1 3YSA 3S-3YS-H15 III YMS E71T-8-Ni1(3) EN 758 T42 3 1 Ni Y N EN 758 T42 3 1 Ni Y N
Nickel (1%) (H10)

NR-232(6) E71T-8 3YSA(5) 3S-3YS-H15 III YMS SA3YMH 3YSH10 W48 E491T-8 EN 758 T42 3 Y N 2 EN 758 T42 3 Y N 2 All
(H15) Diameters

NR-233 E71T8 E71T-8(3) All


(1/16 in. to Diameters
0.072 in. only)

NR-305 E70T-6 2YSA II YMS EN 758 T42 O W N 3 EN 758 T42 O W N 3 3/32 in.
(5/64 in. only) only

E70T-6(3)
(3/32 in. only)

NR-311 Ni E70T-7-K2 2YSA 2S-2YS II YMS SA2YM 2YS EN 758 T42 2 1, EN 758 T42 2 1, 3/32 in.
E80T-G-K2 5Ni WN5 5Ni WN5 only

NR-311 E70T-7 E70T-7(3) W48 E492T-7

NR-3M E70T-4 W48 E492T-4 EN 14700

NR-207 E71T8-K6 E71T-8-K6(3) III YMS SA3YMH 2YSH15 EN 758 T42 3 1Ni Y N 1 H15
(H15)

NR-208-H E91T8-G-H8

(1) Approvals are updated periodically. Consult your local Lincoln district office for the latest Approval/Grade revision. (2) For diameters 0.035 in. (0.9 mm), 0.045 in. (1.1 mm), 0.068 in. (1.7 mm), 5/64 in. (2.0 mm) only.
(3) To AWS rules. (4) Vertical Up and OH 0.040 - 5/64 in. (1.0 - 2.0 mm) diameters only. Vertical down for 0.068 in. (1.7 mm) and 5/64 in. (2.0 mm) (5) Non-low hydrogen wire. Requires special approval for high strength steel.
(6) Innershield® NR-232 has a Military Grade Classification of MIL-71T-8AS for 0.068 in. (1.7 mm) and 0.072 in. (1.8 mm) diameters only.

ABS: American Bureau of Shipping CWB: Canadian Welding Bureau


Lloyd’s: Lloyd’s Register of Shipping FEMA 353: Federal Emergency
DNV: Det Norske Veritas Management Agency
GL: Germanischer Lloyd AWS D1.8: Seismic Welding Guidelines
BV: Bureau Veritas

Innershield ® Wire
39 www.lincolnelectric.com
STORAGE RECOMMENDATIONS FOR FLUX-CORED (FCAW-G AND FCAW-S) ELECTRODES

Lincoln Electric flux-cored electrodes perform best when 3. When not in use, electrodes should be placed in original
kept dry and stored properly. Electrode should be used packaging and sealed as best as possible.
directly from the original, undamaged package, and when
4. If exposed to moisture conditions, discard any rusty
stored in accordance to the conditions listed below.
electrode.
When proper procedures are not followed, consumables
5. For applications in which the weld metal hydrogen must
may show signs of moisture. These include porosity, a rough
be controlled (usually 8 mL or lower), or where shipping
bead surface or slag that is unusually difficult to remove.
and storage conditions are not controlled or known, only
The following minimum precautions should be taken to hermetically sealed packaging is recommended.
safeguard the electrode after opening the original package:
6. After exposure, hydrogen levels can be reduced by
1. It is recommended to use electrodes within one week conditioning the electrode. Electrodes may be
of opening the original package. conditioned at a temperature of 100ºC ± 14ºC (250ºF ±
25ºF) for a period of 6 to 12 hours, cooled and then
2. Open electrodes should not be exposed to damp
stored in seal poly bags (4 mL minimum thickness) or
moisture conditions or extremes in temperature and/or
equivalent. Electrode on plastic spools should not be
humidity where surface condensation can occur.
heated at temperatures in excess of 65ºC (150ºF).

Innershield ® Wire
40 www.lincolnelectric.com
NOTES

Innershield ® Wire
41 www.lincolnelectric.com
NOTES

T E S T R E S U LT S
Test results for mechanical properties, deposit or electrode composition and diffusible hydrogen levels were obtained from a weld produced and tested according to prescribed
standards, and should not be assumed to be the expected results in a particular application or weldment. Actual results will vary depending on many factors, including, but not
limited to, weld procedure, plate chemistry and temperature, weldment design and fabrication methods. Users are cautioned to confirm by qualification testing, or other appropri-
ate means, the suitability of any welding consumable and procedure before use in the intended application.

C U S T O M E R A S S I S TA N C E P O L I C Y
The business of The Lincoln Electric Company® is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet the needs of
our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for information or advice about their use of our products. Our employees respond to
inquiries to the best of their ability based on information provided to them by the customers and the knowledge they may have concerning the application. Our employees, however, are not
in a position to verify the information provided or to evaluate the engineering requirements for the particular weldment. Accordingly, Lincoln Electric does not warrant or guarantee or assume
any liability with respect to such information or advice. Moreover, the provision of such information or advice does not create, expand, or alter any warranty on our products. Any express or
implied warranty that might arise from the information or advice, including any implied warranty of merchantability or any warranty of fitness for any customers’ particular purpose is
specifically disclaimed.

Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole responsibility of the
customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com for any updated information.

Innershield ® Wire
42 www.lincolnelectric.com
DISTRICT SALES OFFICES

U.S.A. ILLINOIS MINNESOTA OKLAHOMA VIRGINIA


CHICAGO 60440-3538 MINNEAPOLIS 55369-5455 OKLAHOMA CITY 73139-2432 VIRGINIA BEACH 23455-7216
ALABAMA (630) 783-3600 (763) 391-8384 (405) 616-1751 (757) 870-5508
BIRMINGHAM 35124-1156 BLOOMINGTON 61704-1510 TULSA 74146-1622 DANVILLE 24541-6785
(205) 988-8232 (309) 838-3717 MISSISSIPPI (918) 622-9353 (434) 441-0227
DOTHAN 36303-5533 JACKSON 39212-9635 HAMPTON ROADS 23455-7216
(334) 782-1074 INDIANA (601) 372-7679 OREGON (757) 870-5508
MOBILE 3652-5323 FT. WAYNE 46825-1551 Contact VANCOUVER, WA
(251) 377-8574 (260) 484-4422 MISSOURI (360) 693-4712 WASHINGTON
INDIANAPOLIS 46250-5536 KANSAS CITY (KS) VANCOUVER 98661-8023
ALASKA (317) 845-8445 66214-1629 PENNSYLVANIA (360) 693-4712
Contact VANCOUVER, WA EVANSVILLE 47711-2340 (913) 894-0888 PHILADELPHIA 19008-4310 SPOKANE 99005-9637
(360) 693-0155 (216) 287-0227 ST. LOUIS 63038-0069 (610) 543-9462 (509) 953-7399
SOUTH BEND 46530-7384 (563) 386-6522 PITTSBURGH 15001-4800
ARIZONA (574) 271-3473 SPRINGFIELD 65804-2309 (724) 857-2750 WASHINGTON DC
PHOENIX 85260-1745 (417) 773-2657 ERIE 16506-1566 Contact PHILADELPHIA
(480) 348-2004 IOWA (216) 469-1059 (610)543-9462
CEDAR RAPIDS 52402-3160 MONTANA HARRISBURG 17104-1422
ARKANSAS (319) 362-6804 Contact VANCOUVER, WA (717) 213-9163 WEST VIRGINIA
LITTLE ROCK 72032-4371 DAVENPORT 52806-1344 (360) 693-4712 BARBOURSVILLE 25504-9665
(501) 764-0480 (563) 386-6522 RHODE ISLAND (304) 736-5600
DES MOINES NEBRASKA Contact BOSTON MA
CALIFORNIA (563) 386-6522 OMAHA 68046-7031 (508) 788-9353 WISCONSIN
LOS ANGELES 90670-4062 (402) 203-6401 GREEN BAY 54302-1829
(562) 906-7700 KANSAS SOUTH CAROLINA (920) 435-1012
N. CALIFORNIA 95762-5706 KANSAS CITY 66214-1629 NEW HAMPSHIRE FLORENCE 29063-8468 MILWAUKEE 53051-1103
(916) 939-8788 (913) 894-0888 Contact BOSTON MA (803) 331-4340 (262) 650-9364
WICHITA 67235-9261 (508) 788-9353
COLORADO (316) 789-5954 SOUTH DAKOTA
DENVER 80112-5115 OMAHA 68046-7031 NEW MEXICO SIOUX FALLS 571110-4004 CANADA
(303) 792-2418 (402) 203-6401 ALBUQUERQUE 87120-5360 (262) 227-2807 ALBERTA
(505) 890-6347 CALGARY
CONNECTICUT KENTUCKY TENNESSEE
NORTH HAVEN 06238-1090 (403) 253-9600/
LOUISVILLE 47112-7025 NEW YORK MEMPHIS 38119-5811 (877) 600-WELD
(860) 742-8887 (502) 727-7335 BUFFALO 14228-1035 (901) 683-6260 WINNIPEG
(716) 574-2292 NASHVILLE 37228-1708 (204) 488-6398
DELAWARE LOUISIANA SYRACUSE 13057-9313 (615) 291-9926
Contact PHILADELPHIA, PA BATON ROUGE 70808-3150 (315) 432-0281 TRI-CITIES 37659-5693
(610) 543-9462 BRITISH COLUMBIA
(225) 922-5151 (423) 612-1204 VANCOUVER
HOUMA 70364-2516 NORTH CAROLINA (604) 945-7524
FLORIDA (225-773-5614 CHARLOTTE 28273-3552 TEXAS
JACKSONVILLE 32216-4634 LAFAYETTE 70507-3126 (704) 588-3251 DALLAS 76051-7602
(904) 642-3177 MARITIMES
(337) 886-1090 RALEIGH 27540-9649 (817) 329-9353 NEWBRUNSWICK
MIAMI 33178-1175 SHREVEPORT 75692-9313 (704) 301-0565 LUBBOCK 76902-1151
(305) 888-3203 (506) 849-4474
(318) 518-4099 (325) 260-3667
ORLANDO 32714-1954 NORTH DAKOTA ENNIS 75119-4940
(407) 788-8557 MANITOBA
MAINE Contact MINNEAPOLIS, MN (903) 343-7918 WINNIPEG
TAMPA Contact BOSTON MA (763) 391-8384 HOUSTON 77060-3143
(888) 935-3860 (204) 488-6398
(508) 788-9353 (281) 847-9444
OHIO MONTGOMERY 77316-2429 ONTARIO
GEORGIA MARYLAND BEDFORD (713) 724-2350
ATLANTA 30122-3811 MISSISSAUGA
BALTIMORE 21044-5675 (216) 407-9538 (905) 565-5600
(888) 935-3860 (410) 443-1091 AKRON UTAH
SAVANNAH 31324-3866 TORONTO
MASSACHUSETTS (216) 383-2662 MIDVALE 84047-3759 (416) 421-2600/
(912) 656-1978 BOSTON 01581-2658 CINCINNATI 45242-3706 (801) 233-9353 (800) 268-6114
(508) 788-9353 (513) 554-4440
HAWAII CLEVELAND 44117-2525 VERMONT
Contact LOS ANGELES, CA QUEBEC
MICHIGAN (216) 383-2662 Contact BOSTON MA MONTREAL
(562) 906-7700 DETROIT 48393-4700 COLUMBUS 43221-4073 (508) 788-9353 (450) 654-3121
(248) 348-2575 (614) 488-7913
IDAHO GRAND RAPIDS 49512-3924 TOLEDO 43551-1914
Contact SALT LAKE CITY, UT (616) 942-8780 (419) 874-6331
(801) 233-9353

International Headquarters
LATIN AMERICA EUROPE RUSSIA, AFRICA & ASIA PACIFIC
Miami, Florida U.S.A. Barcelona, Spain MIDDLE EAST Shanghai
Phone: (305) 888-3203 Phone: 34 91 816 4266 Cleveland, Ohio U.S.A. Phone: 86 21 6602 6620
Phone: (216) 481-8100 Australia
Phone: 61 2 9772 7222

The Harris Products Group


®

4501 Quality Place, Mason, Ohio 45040 U.S.A. • Web Site: www.harrisproductsgroup.com
Consumables: ph: 1-800-733-8912, fax: (513) 754-8778 • Equipment: ph: 1-800-241-0804, fax: (770) 535-0544

Innershield ® Wire
43 www.lincolnelectric.com
THE LINCOLN ELECTRIC COMPANY
22801 St. Clair Avenue • Cleveland, OH U.S.A. • 44117-1199
Phone: +1.216.481.8100 • www.lincolnelectric.com
C3.2000 7/09 © The Lincoln Electric Co. All Rights Reserved. Printed in the U.S.A.