Surface Preparation for

Concrete Surfaces
14-28
days for curing of concrete surfaces under
normal weather conditions before painting

Surface Preparation for New Masonry


efflorescence
water-containing dissolved
alkali salts brought to the surface

Surface Preparation for New Masonry


1:16
ratio of Boysen Masonry
Neutralizer B-44 to clean
water; application by
brush or roller

Surface Preparation for New Masonry


Let dry overnight.

Sand surface to remove white crystals.

Make sure surface to be painted should be clean


and dry, free from all possible contaminants.

Surface Preparation for New Masonry


Surface Preparation for New Masonry
Surface Preparation for New Masonry
Surface Preparation for New Masonry
Surface Preparation for New Masonry
Surface Preparation for New Masonry
2-3 mm

K-201 Permaplast

Exterior
Interior
High Performance
Acrylic Skimcoat
4 L Liquid mixed with
cement at 1:1 ratio

K-210 Permaplast
Interior
Only

2K Skimcoat

4 L Liquid and 28 kg bag


mixed with 8 L water

Surface Preparation for New Masonry


for surface imperfections on walls

If BARE surface, use SKIMCOAT.

If PAINTED surface, use PUTTY.

Surface Preparation for New Masonry


KONSTRUKT High Performance
Acrylic Skimcoat K-201
BOYSEN Acrytex Sealer B-1708
BOYSEN Matte Shield B-4600

Industrial Concrete Finishes


KONSTRUKT High Performance
Acrylic Skimcoat K-201
BOYSEN Acrytex Sealer B-1708
BOYSEN Acrytex Clear Coat B-1700

Industrial Concrete Finishes


Remove loose, scaling and peeling paint.

Check paint compatibility.

Scuff sand intact paint film.

Make sure surface to be painted should be clean


and dry, free from all possible contaminants.

Surface Preparation for Repainting of Concrete


Paint Systems for

Interior Concrete
Paint Systems for Interior Concrete
BOYSEN
BOYSEN Virtuoso
Permacoat
Healthy Home Silk Touch
Latex

Binder Acrylic

Solvent Water
*thin with not more than 500mL per gallon (4L) of paint

Recoating 2 hours
Interval *measured at 25oC and 50% relative humidity

Coverage 30-35 square meters


per 4L *depending on surface texture and porosity

Flat
Sheen Semi-Gloss Satin Matte
Gloss

Odor-less
Special Regular Latex
Odor-less
Anti-bacterial
Property Anti-bacterial
Easy-to-Clean
Recommended Paint System
Primer:
BOYSEN Permacoat Flat Latex B-701

Putty:
BOYSEN Masonry Putty B-7311 (<1mm)
BOYSEN Perma-putty B-7312 (<2mm)

Topcoat:
BOYSEN Permacoat Latex
BOYSEN Healthy Home
Virtuoso Silk Touch

Paint Systems for Interior Concrete


Paint Systems for

Exterior Concrete
Mixing Ratio:
6.5-7.5 kgs of Portland Cement
per gallon (4L) of Plexibond

Coverage Rate:
5-6 sqm. per gallon
(depends on surface profile)

Paint Systems for Exterior Concrete


1st Coat:
Boysen Elasti-kote Sealer B-5800

2nd Coat:
Boysen Elasti-kote Basecoat B-5805

Spot Putty:
Boysen Elasti-kote Putty B-5811

3th/4th Coat:
Boysen Elasti-kote Topcoat B-5815

Paint Systems for Exterior Concrete


Self-priming flexible coating

Capable of bridging
hairline cracks

Long term durability


and color retention

Paint Systems for Exterior Concrete


Paint Systems for Exterior Concrete
Recommended Paint System

Primer:
BOYSEN Acrytex Primer B-1705

Putty:
BOYSEN Acrytex Cast B-1711 (<1mm)

Topcoat:
BOYSEN Acrytex Topcoat
BOYSEN Wallguard
BOYSEN Permacoat Latex

Paint Systems for Exterior Concrete


Paint Systems for

Concrete Flooring
3 parts Primer : 1 part Catalyst/Curing Agent
(20 minutes Induction Time)
1 part Prepared Mixture : 1 part Epoxy Reducer

Primer Application for Concrete Flooring


Solvent-based Acrylic Water-based
For Interior only For Exterior & Interior
3:1 with Curing Agent 4:1 with Curing Agent

Paint Application for Concrete Flooring


Topcoat application should be done within 7 days;
otherwise, repriming is necessary

Curing Time: 3 days for foot traffic, 7 days for heavy-duty use

Paint Application for Concrete Flooring


BOYSEN Alkyd BOYSEN Reflectorized
Traffic Paint Traffic Paint

Paint Application for Concrete Flooring


Surface Preparation for

Wooden Surfaces
Hammer all nails deep enough to apply putty.

Sand rough wood until smooth.

Dust off surfaces then wipe with a clean rag.

Use Nation Wood Bleach 1 & 2 to even out tones.

Surface Preparation for Wooden Surfaces


Primer:
BOYSEN Flatwall Enamel B-800

Putty:
BOYSEN Plasolux Glazing Putty B-311

Topcoat:
BOYSEN Quick Drying Enamel

Thinner:
BOYSEN Paint Thinner B-0340
(max thinning ratio, 1:4 thinner to paint)

Paint Systems for Wooden Surfaces


Primer:
BOYSEN Lacquer Primer Surfacer B-305

Putty:
BOYSEN Lacquer Spot Putty B-306

Topcoat:
BOYSEN Automotive Lacquer B-1300

Thinner:
BOYSEN Lacquer Thinner B-50

Paint Systems for Wooden Surfaces


Tannin Staining

Paint Systems for Wooden Surfaces


Primer:
BOYSEN WoodPrime B-180

Putty:
BOYSEN Masonry Putty B-7311 (<1mm)

Topcoat:
BOYSEN Permacoat Latex
BOYSEN Healthy Home
Virtuoso Silk Touch

Paint Systems for Wooden Surfaces


1st Coat:
BOYSEN Oil Wood Stain

2nd Coat:
BOYSEN Lacquer Sanding Sealer

Final Coat:
BOYSEN Clear Gloss Lacquer
BOYSEN Dead Flat Lacquer

Stain and Varnish for Wooden Surfaces


Exterior Wood Stain

Water Repellent

Gives Wood Preserving Properties

Stain and Varnish for Wooden Surfaces


Surface Preparation for

Metal Surfaces
Wipe surface with rag soaked in paint thinner.

Etch surface with 10% Boysen Metal Etching


Solution B-71 (1:9 with water)

Let it stay for 10-15 minutes before rinsing with


water then prime immediately.

Surface Preparation for Metal Surfaces


Remove rust by wire brushing and sanding.

Apply Boysen Metal Etching Solution B-71.

Let it stay for 10-15 minutes.

Remove residue, wipe with solvent, then prime


immediately.

Surface Preparation for Rusted Metal


Metal Primers
Metal Topcoats
Metal Topcoats
Paint Problems & Solutions

Troubleshooting
Efflorescence
Improper curing of concrete and surface preparation
Presence of moisture in concrete
Fading
Wrong choice of colorants
Too much colorants
1:16 maximum ratio of Boysen Tinting
Color to respective paint
TOPCOAT TINTING COLOR

Boysen Permacoat Latex Boysen Latex Colors

Boysen Quick
Boysen Oil Tinting Colors
Drying Enamel

Boysen Acrytex
Boysen Acrytex
Tinting Colors

Boysen Automotive Boysen Lacquer


Lacquer Tinting Colors
Mildew
Exposure to cold climate, moisture, vegetation
Treat with 1:3 bleach solution
Blistering
Water seepage on walls
Poor surface preparation
Peeling
Absence of primer
Use of powdered materials (e.g. powdered skimcoat, patching compound)
Flaking
Interior paints used for exterior (e.g. Lacquer-type paints)
Application of solvent-based paint over water-based paint
Lap Marks
Overdilution of thinner/reducer
Wrong application technique
TOPCOAT PAINT THINNER NEEDED

4L Water-Based Paints ½ Liter of Clean Water


(e.g. Permacoat, Wallguard)

1L Boysen Acrytex
4L Boysen Acrytex Reducer B-1750
*if using brush or roller

1L Boysen Epoxy
4L Boysen Epoxy Enamel Reducer B-55
*if using brush or roller

4L Boysen Quick 1L Boysen Paint


Drying Enamel Thinner B-0340
*if using brush or roller

A can of Boysen Automotive A can of Boysen Lacquer


Lacquer B-1300 Thinner B-50
Saponification
Chemical reaction of oil with alkali
Enamel paints applied over concrete or fiber cement boards
Incompatible Systems
Use of product not intended for surface or condition
Wrong combination of paint system
Useful Tips
BOYSEN App
BOYSEN App
BOYSEN App
BOYSEN App
BOYSEN App
BOYSEN App
BOYSEN App
BOYSEN App
BOYSEN App
Boysen Permacoat Latex

Boysen Healthy Home

Virtuoso Silk Touch

Titan Superflex
Elastomeric Paint

Boysen Mix & Match Stations


The Color Library @ IKEA Pasay
Boysen Paints Philippines
Boysen Paints Philippines
Product Presentation
October 3, 2023

Engr. Deniel de los Reyes


Technical Service Department
Pacific Paint (Boysen) Philippines Inc.

You might also like