Professional Documents
Culture Documents
Detcon UniTox ™
SPECIFICATIONS
Sensor Type
Electrochemical Fuel Cell
Measurement Range
0-100 ppm Ammonia
Universal Transmitter Module
Other ranges available with Intelligent Sensor Module
Repeatability
±2% FS Standard 4-20 mA Output
Response/Clearing Time
T90 <90 seconds
Span Drift DESCRIPTION
<2% signal loss per month Detcon Model DM-202-NH3 sensor is designed to
Operating Temperature Range
Sensor: -40°C to +50°C; -40°F to +122°F
detect and monitor NH3 in air over the range
Transmitter: -20°C to +55°C; -4°F to +131°F 0-100 ppm. The sensor assembly consists of an
Operating Humidity Range Intelligent Sensor Module with electrochemical sensor,
15-90% RH non-condensing and a Universal Transmitter Module packaged in a
Output
Linear 4-20 mA DC molded fiberglass enclosure. Its universal design allows
Input Voltage complete interchangeability of any Intelligent Sensor
11.5-30 VDC Module resulting in reduced maintenance costs.
2 wire loop-powered
Power Consumption + Intrinsically Safe design
<1/2 watts @ 24 VDC + NEMA 4X weatherproof enclosure
Electrical Classification
NEMA 4X Class 1, Div. 1, Groups A, B, C, D + CSA/NRTL (US OSHA Certified); Class I, Div. 1, Groups A, B, C, & D
Sensor Life/Warranty + 2 wire loop powered
Sensor: 2 year warranty + Plug and Play field exchangeable Intelligent Sensor Module
Transmitter: 2 year warranty + Universal Transmitter Module adapts to any Intelligent Sensor Module
+ Modules for up to 40 different gas types available
DIMENSIONS + No electrolyte maintenance
+ Automatic span calibration
5 1/2" + Non-Intrusive and simple menu interface
4 3/4"
+ Built-in system diagnostics
1/4"
Mounting Hole Removable rain cover Twist-off collar to exchange
2 1/4" to replace plug-in sensor Intelligent Sensor Module
3 1/4"
3 1/4" Deep
Electrochemical
plug-in sensor
Universal
Intelligent
Transmitter
8" Sensor Module
Module
www.detcon.com R112403