Professional Documents
Culture Documents
EC
ON
19775
IT
BOA
ARCH
RD
N
ER
SE
IK
ND
L . E
ST
A J ORG
TE LA
O F MA R Y
08.08.2023
ROOF DECK
(2) #10 SCREWS @
EA. BRACE, TYP.
TENANT IMPROVEMENTS
H
MTL STUDS @ 48" o/c AS REQD.
RT
NO
SCALE: 1/8" = 1'-0"
5/8" GYP. BD. ON 18 GA 3-5/8"
®
MTL STUDS @ 16" o/c, RE: SPECS. (2) #6 SCREWS @ EA. BRACE, TYP.
18 GA TRACK W/ #6 SCREWS
EA. SIDE, TYP.
2'-8" 2'-8" 2'-10"
ASSISTANT
CONFERENCE MANAGERS QUALITY OFFICE CENTER DIRECTOR VESTIBULE
RE: RCP TRAINING 114 113 100
117 115
116
5/8" GYP. BD. ON 18 GA 3 5/8"
MTL STUDS @ 16" o/c TO 3'-0 1/2"
ROOF ASSEMBLY
RE: RCP
EMPLOYEE LOUNGE
134 10'-0"
CLG. GRID, RE: RCP
SUPPLY
RE: RCP
1,098 SF
4'-6" OR GREATER TO MIDSPAN 124
3'-5"
6'-10"
STATION #5
2'-3"
106
4'-7"
2'-3"
14'-0" 4'-0" STATION #4
SCALE: 1" = 1'-0" 105
4'-7"
2'-3"
3'-6"
18 GA TRACK W/ #6 (2) #10 SCREWS @ 16" o/c, TYP. EXIT ACCESS RECEPTION
SCREWS, EA SIDE 133 101
STATION #3
30'-0"
2'-3"
4'-7"
104
CORRIDOR
4'-7"
2'-3"
ROOF DECK 125
(2) #10 SCREWS @ TOILET STATION #2
132 103
EA. BRACE, TYP.
4'-7"
2'-3"
12 1'-6"
L4x4x16GAx12" LONG BENT PLT. 1'-4" 4'-0" 4'-0" 1'-4"
W/ (2) #10 SCREWS INTO ROOF DECK 12
2'-3"
STATION #1
1'-6"
6'-10"
102
TOILET JAN/MECH 3
3'-5"
18 GA 3-5/8" MTL STUDS @ 48" o/c, 131 FREEZER #2 DONOR FLOOR A2.2
126
4'-0"
ALTERNATING SIDES, TYP. 123 54 BEDS
118
PLASMA
1'-6"
PROCESSING
2'-1" 5'-7" 2'-4"
UP
TOILET 120
UP
130 10'-0"
"
4'-0"
8'-0"
'-0
18 GA 3-5/8"
R8
CONFIDENTIAL
MTL STUDS @ 48" o/c AS REQD.
2'-0"
FREEZER #1 THESE PLANS ARE THE CONFIDENTIAL PROPERTY AND
RACK CONTAIN EXCLUSIVE DESIGNS OF THE ARCHITECT. ANY
5/8" GYP. BD. ON 18 GA 3 5/8" MTL STUDS 121
5/8" GYP. BD. ON 18 GA 3-5/8" EQUIPMENT 4'-0" 4'-0" USE OF THESE DRAWINGS OR THE INFORMATION
@ 16" o/c TO ROOF ASSEMBLY 2'-0" 4'-0" 2'-0"
MTL STUDS @ 16" o/c, RE: SPECS. REPAIR CONTAINED HEREIN FOR ANY REASON OTHER THAN AS
ELEC./I.T. 119 EQ. EQ. EXPRESSLY AUTHORIZED BY ARCHETYPE DESIGN
PROVIDE 3-5/8" 18 GA BIOWASTE GROUP, INC. IS STRICTLY PROHIBITED. THESE
127 EXAM #4 EXAM #3 EXAM #2 EXAM #1
RE: ELEC. FOR ACCENT LIGHTING TO MATERIAL 128
EQ. EQ.
TRACK AT MIDSPAN FOR LIFT 112 111 110 109 WOMEN DRAWINGS HAVE BEEN DISTRIBUTED WITH THE
TOTAL SPANS IN EXCESS OF 9'-0". BE INSTALLED IN THIS AREA. UNDERSTANDING THAT ANYONE RECEIVING OR
12 129 108
PROVIDE (1) #6 SCREW AT EA. OTHERWISE OBTAINING POSSESSION OF THEM WILL BE
12 EXPRESSLY NOTIFIED OF THEIR CONFIDENTIAL NATURE
MEMBER. AT SPLICE LOCATIONS
EITHER LAP MEMBERS OR ABUT
W/ (2) #6 SCREWS EA. END OF RE: RCP
9" DATE
EA. MEMBER
07 NOVEMBER 2022
SCALE
1/8" = 1'-0"
JOB NO.
CLG. GRID (ATC), RE: RCP
1'-0"
22-026
SHEET
5/8" GYP. BD. ON 18 GA 3-5/8"
MTL STUDS @ 16" o/c, RE: SPECS.
DIMENSIONED
4'-6" OR GREATER TO MIDSPAN
H
SUSPENDED SOFFIT FRAMING DETAIL
2
RT
NO
SCALE: 1/8" = 1'-0"
SCALE: 1" = 1'-0" REFLECTED CEILING