Nov 2017

RLA Sample Kit


- How to send RLA samples to lab

Shell Marine(Great China)

1
OUR SAMPLE LABEL

2
① Completing the Sample Label: “SECTION 1”

1. Please fill the date of “Sample Taken”, “RLA


Machinery Code”* and check the “Sent to Lab”.
*Please refer to Vessel Machinery List issued by Shell.

2 2 0 8 1 7

A01


2. Please keep “SECTION 1” in your vessel for
your record. 3
① Completing the Sample Label: “SECTION 2”

1. The letters in red are must to


be filled.
2. The letters in blue are option
EVER BONNY to be filled. If these are in,
these information will be added
947789 in the analysis report, which
enables you to build up a
A01 1 3 0 4 1 8 meaningful database of used oil
analysis results for your
8,760
Argina S3 30 machinery.
380cSt
2,000
3.3
50

Note: Incorrectly completed labels will lead to samples being registered in the laboratories as
“unidentified”. An unidentified samples will cause delays in analysis or cannot be analyzed.
4
① Completing the Sample Label: “SECTION 3”

Cylinder Drain Oil samples ONLY


No For accurate analysis and interpretation of
cylinder drain oil samples,
7,850
all information must be provided.
1023

1023
For the samples other than cylinder drain oil
1023 samples, please leave “SECTION 3” blank.
1023

1.4

225

86

77

16

5
② Attaching “SECTION 4” to the Sample Bottle

1. Check that an air space has


been left above sample and that
the seal is tight.

4
2. Please detach the sample label
from top of “SECTION 4” and
attach to the sample bottle.

3. If “ISO 4406/4407” test is required, please prepare


ANOTHER sample bottle(2 bottles samples)and
attach the lower label in “SECTION 4” to this
sample bottle.
6
③ Attaching the Lab Address Label to the Envelope

1. Please attach the relevant laboratory coloured address label to


the plastic envelope.

7
④ Putting the Bottles and the Labels into the Envelope

1. Please put the sample bottles and “SECTION 2” & “SECTION 3” of


the label into the plastic envelope. (Please keep “SECTION 1” in
your vessel for your record.) 5 or 6 bottles can be put together into
each envelope.
2. Please seal the envelope using the two sealing strips.
8
⑤ Sending the Sample Bottles to Shell Laboratory

Agent Shell laboratory

1. Please hand over the envelopes with sample bottles to your agent
onshore.- MUST NOT hand over to delivery barge/truck.
2. The agent will send them to Shell laboratory.

*Please do NOT send the sample bottles to China & India labs outside
of respective country in case of expensive custom clearance caused
by.

9
Shell RLA Laboratory List

*Please do NOT send the sample bottles to Showa Shell Sekiyu


K.K. in Tokyo, Japan. There is no Shell RLA laboratory facility. Ausutralia
Shell Marine Laboratory
28 Reid Road
Perth International Airport
Newburn WA
Australia 6105
10
Phone: +61 893 733 609
Shell RLA Laboratory List

Ausutralia
Shell Marine Laboratory
28 Reid Road
Perth International Airport
Newburn WA
Australia 6105
Phone: +61 893 733 609

Attention:

Please do NOT send the sample bottles to China & India labs outside
of respective country in case of expensive custom clearance caused
by.中国和印度两家化验室仅接受本国港口寄送的油样

11
Instruction for ISO 4406/7 sampling
Customer retention Deliver with samples together( pls. do not stick on bottles) Stick on bottles

 Cleanliness Particle Count (ISO 4406/7) requires 2 sample bottles with the same sample number (SECTION 4).
1
 For ISO 4407 send samples to UK lab only, for ISO 4406 samples can be sent to any of our labs.
How to use Section 4 ?

Please Make sure:


 2 full bottles of sample taken
 Same sample number on each

 Keep in line with sample


number in section 2