You are on page 1of 6

From: ROLLECHIM Simone Ferron

To: Vijayanand Rajagopalan


Subject: Re: on phthalic anhydride technology
Date: Wednesday, March 23, 2022 10:10:22 PM

[CAUTION] EXTERNAL EMAIL ..

The content of phthalic acid is higher when naphthalene or mixed feed (naphthalene + o-X) is
used.
Catalyst technology is indeed improving year after year, with the aim to increase the
conversion to PA and to reduce or minimize the formation of by-products.
Reaction operating conditions are also very important to keep the content of by-products at
its minimum.
Due to the physical properties of phthalic acid, the removal by distillation is not possible, for
this reason the dehydration is used.

Simone Ferron
Technical Director | Process & Engineering Department

ROLLECHIM S.R.L.
Via Della Scienza, 11
36050 Sovizzo (Vicenza) ITALY
Phone: +39 0444 551955
Mobile: +39 328 7198 472
E-mail: simone.ferron@rollechim.com
Skype: simonerollechim

RISERVATEZZA/CONFIDENTIALITY
Il contenuto di questa e-mail e dei file allegati è RISERVATO e da considerarsi utilizzabile solamente dalla persona o dalla
società cui è indirizzato. Se avete ricevuto questa e-mail per errore, siete pregati di rimandarla al mittente e di eliminarla
(Legge italiana 196/2003).
The content of this e-mail and any attached files is CONFIDENTIAL and intended solely for the use of the individual or
company to whom it is addressed. If you have received this e-mail in error, please return it to the sender and delete it (Italian
Law 196/2003).

Save a tree...please don't print this e-mail unless you really need to

Il 23/03/2022 17:29, Vijayanand Rajagopalan ha scritto:

Simone, the decomposer exists only to convert phthalic acid to phthalic anhydride. But
amounts of phthalic acid formed in the exit of reactoris reported to be very low.
Where is phthalic acid exactly formed? Any idea? Is it because of PA getting
hydrolyzed?

Vijay

From: ROLLECHIM Simone Ferron <simone.ferron@rollechim.com>


Sent: Wednesday, March 23, 2022 9:43 PM
To: Vijayanand Rajagopalan <Vijayanand.Rajagopa@ihsmarkit.com>
Subject: Re: on phthalic anhydride technology

[CAUTION] EXTERNAL EMAIL ..

Hi, in the modern process technology the post-reactor is highly recommended by any
PA catalyst producer,
it is definitely suggested not to remove the post-reactor.

Simone Ferron
Technical Director | Process & Engineering Department

ROLLECHIM S.R.L.
Via Della Scienza, 11
36050 Sovizzo (Vicenza) ITALY
Phone: +39 0444 551955
Mobile: +39 328 7198 472
E-mail: simone.ferron@rollechim.com
Skype: simonerollechim

RISERVATEZZA/CONFIDENTIALITY
Il contenuto di questa e-mail e dei file allegati è RISERVATO e da considerarsi utilizzabile solamente dalla
persona o dalla società cui è indirizzato. Se avete ricevuto questa e-mail per errore, siete pregati di
rimandarla al mittente e di eliminarla (Legge italiana 196/2003).
The content of this e-mail and any attached files is CONFIDENTIAL and intended solely for the use of the
individual or company to whom it is addressed. If you have received this e-mail in error, please return it to
the sender and delete it (Italian Law 196/2003).

Save a tree...please don't print this e-mail unless you really need to

Il 22/03/2022 12:11, Vijayanand Rajagopalan ha scritto:


Simone, in case we don’t want to have a postreactor and have just one
main reactor, can we still get 110g PA/xylene yield overall, with 99.8%
minimum purity? Wanted to know
What is the best yield and quality possible without post reactor

Vijayanand

From: ROLLECHIM Simone Ferron <simone.ferron@rollechim.com>


Sent: Tuesday, March 22, 2022 12:40 PM
To: Vijayanand Rajagopalan <Vijayanand.Rajagopa@ihsmarkit.com>
Subject: Re: on phthalic anhydride technology

[CAUTION] EXTERNAL EMAIL ..

Hi, the mentioned dehydration reactor 80 m3 is for one reactor 50k t/y,
therefore in a 100-120k t/y PA Plant we suggest 2 dehydration reactors,
one for each reaction train.

Best regards.
Simone Ferron
Technical Director | Process & Engineering Department

ROLLECHIM S.R.L.
Via Della Scienza, 11
36050 Sovizzo (Vicenza) ITALY
Phone: +39 0444 551955
Mobile: +39 328 7198 472
E-mail: simone.ferron@rollechim.com
Skype: simonerollechim

RISERVATEZZA/CONFIDENTIALITY
Il contenuto di questa e-mail e dei file allegati è RISERVATO e da considerarsi utilizzabile
solamente dalla persona o dalla società cui è indirizzato. Se avete ricevuto questa e-mail per
errore, siete pregati di rimandarla al mittente e di eliminarla (Legge italiana 196/2003).
The content of this e-mail and any attached files is CONFIDENTIAL and intended solely for
the use of the individual or company to whom it is addressed. If you have received this e-
mail in error, please return it to the sender and delete it (Italian Law 196/2003).

Save a tree...please don't print this e-mail unless you really need to

Il 21/03/2022 19:09, Vijayanand Rajagopalan ha scritto:


Hi Simone, thanks for discussion and your inputs on
Rollechim technology today.
Just had a 1clarification. You mentioned that for a 100-
130KTA plant size, we use 2 reactors and 2 rollechem
condenser trains(each train has 4 condenser units).
But is the thermal treatment vessel of 80 m3 is just ONE
vessel for both the lines? Or do you need one 80 m3 thermal
treatment vessel for EACH 60-65KTA reactor? In which case
2 such vessels will be needed for the 120KTA capacity?
Thanks
Vijayanand

From: Vijayanand Rajagopalan


Sent: Monday, March 21, 2022 1:08 PM
To: ROLLECHIM Simone Ferron
<simone.ferron@rollechim.com>
Subject: RE: on phthalic anhydride technology

+91 9611999880
Iam 4.5 hrs ahead of you, you can call me between 7.30 and
10.30 am your time

Vijayanand

From: ROLLECHIM Simone Ferron


<simone.ferron@rollechim.com>
Sent: Monday, March 21, 2022 12:47 PM
To: Vijayanand Rajagopalan
<Vijayanand.Rajagopa@ihsmarkit.com>
Subject: Re: on phthalic anhydride technology

[CAUTION] EXTERNAL EMAIL ..

   Dear Mr. Vijayanand,

please share your mobile number and I will call you back in
the morning through WhatsApp.

Best regards.

Simone Ferron
Technical Director | Process & Engineering Department

ROLLECHIM S.R.L.
Via Della Scienza, 11
36050 Sovizzo (Vicenza) ITALY
Phone: +39 0444 551955
Mobile: +39 328 7198 472
E-mail: simone.ferron@rollechim.com
Skype: simonerollechim

RISERVATEZZA/CONFIDENTIALITY
Il contenuto di questa e-mail e dei file allegati è RISERVATO e da
considerarsi utilizzabile solamente dalla persona o dalla società cui è
indirizzato. Se avete ricevuto questa e-mail per errore, siete pregati di
rimandarla al mittente e di eliminarla (Legge italiana 196/2003).
The content of this e-mail and any attached files is CONFIDENTIAL and
intended solely for the use of the individual or company to whom it is
addressed. If you have received this e-mail in error, please return it to the
sender and delete it (Italian Law 196/2003).

Save a tree...please don't print this e-mail unless you really need to

Il 21/03/2022 07:26, Vijayanand Rajagopalan ha scritto:

Dear Simone, please let me know a suitable


time when I can call you regarding this
(Germany time)

Vijayanand

From: Vijayanand Rajagopalan


Sent: Wednesday, February 23, 2022 7:43 PM
To: simone.serron@rollechim.com
Cc: enquiries@rollechim.com
Subject: on phthalic anhydride technology
Importance: High

Dear Simone,

I am with IHS Markit and we are currently


reviewing phthalic anhydride tech
improvements which we publish in form of
reports and are widely read by our subscribers
within petrochemical/oil&gas industries.
I had just called your company to enquire
about technical details(shareable) regarding
continuous dehydration and switch condensers
technologies
And wonder if you have any case studies/lant
data which illustrated how they work and
whether you use any additives in thermal
decomposition and so on.
I also wanted to get an idea of cost range for
these equipment roughly, say for a 100KTA
capacity or plant or any capacity close to this
number, just to get an idea.

Let me know if you can share any details


regarding this. I can call you later too if you
provide a phone number

Thanks
Vijayanand
IHS Markit

The information contained in this message is intended only for


the recipient, and may be a confidential attorney-client
communication or may otherwise be privileged and confidential
and protected from disclosure. If the reader of this message is
not the intended recipient, or an employee or agent responsible
for delivering this message to the intended recipient, please be
aware that any dissemination or copying of this communication is
strictly prohibited. If you have received this communication in
error, please immediately notify us by replying to the message
and deleting it from your computer. S&P Global Inc. reserves the
right, subject to applicable local law, to monitor, review and
process the content of any electronic message or information
sent to or from S&P Global Inc. e-mail addresses without
informing the sender or recipient of the message. By sending
electronic message or information to S&P Global Inc. e-mail
addresses you, as the sender, are consenting to S&P Global Inc.
processing any of your personal data therein.

The information contained in this message is intended only for the recipient, and
may be a confidential attorney-client communication or may otherwise be
privileged and confidential and protected from disclosure. If the reader of this
message is not the intended recipient, or an employee or agent responsible for
delivering this message to the intended recipient, please be aware that any
dissemination or copying of this communication is strictly prohibited. If you have
received this communication in error, please immediately notify us by replying to
the message and deleting it from your computer. S&P Global Inc. reserves the
right, subject to applicable local law, to monitor, review and process the content of
any electronic message or information sent to or from S&P Global Inc. e-mail
addresses without informing the sender or recipient of the message. By sending
electronic message or information to S&P Global Inc. e-mail addresses you, as the
sender, are consenting to S&P Global Inc. processing any of your personal data
therein.

The information contained in this message is intended only for the recipient, and may be a
confidential attorney-client communication or may otherwise be privileged and confidential and
protected from disclosure. If the reader of this message is not the intended recipient, or an employee
or agent responsible for delivering this message to the intended recipient, please be aware that any
dissemination or copying of this communication is strictly prohibited. If you have received this
communication in error, please immediately notify us by replying to the message and deleting it from
your computer. S&P Global Inc. reserves the right, subject to applicable local law, to monitor, review
and process the content of any electronic message or information sent to or from S&P Global Inc. e-
mail addresses without informing the sender or recipient of the message. By sending electronic
message or information to S&P Global Inc. e-mail addresses you, as the sender, are consenting to
S&P Global Inc. processing any of your personal data therein.

The information contained in this message is intended only for the recipient, and may be a confidential attorney-client
communication or may otherwise be privileged and confidential and protected from disclosure. If the reader of this
message is not the intended recipient, or an employee or agent responsible for delivering this message to the intended
recipient, please be aware that any dissemination or copying of this communication is strictly prohibited. If you have
received this communication in error, please immediately notify us by replying to the message and deleting it from your
computer. S&P Global Inc. reserves the right, subject to applicable local law, to monitor, review and process the
content of any electronic message or information sent to or from S&P Global Inc. e-mail addresses without informing
the sender or recipient of the message. By sending electronic message or information to S&P Global Inc. e-mail
addresses you, as the sender, are consenting to S&P Global Inc. processing any of your personal data therein.

You might also like