Professional Documents
Culture Documents
Package Register & Basic Tuning Ver02
Package Register & Basic Tuning Ver02
(OPERATION LEVEL 1)
March 2013
r02
CONFIDENTIALITY
The information contained in this file may be confidential and legally
privileged. If you are not the intended recipient, don’t proceed further
and delete this file and destroy any copies. Any dissemination or use
of this information by a person other than the intended recipient is
unauthorized and may be illegal.
CONFIDENTIAL
REVISION INFORMATION
CONFIDENTIAL
PACKAGE REGISTER & BASIC TUNING
AOI Training
Mar 2013
r03
PACKAGE REGISTER
In this material, You will learn about Package register for each
component.
Please look through each page.
CONFIDENTIAL
• PKG Register
• Inspection Condition
• Basic Procedure for each component
PACKAGE REGISTER (1/2)
T T Lead
This is the first step of job programming. And most important point.
CONFIDENTIAL
PACKAGE REGISTER (2/2)
Set the Proper size for Body and Lead
Body Thickness
Lead Thickness
CONFIDENTIAL
INSPECTION CONDITION
Select the Algorithm and adjust the Inspect condition.
Inspect Condition
• Pad Overhang
• Coplanarity
• Dimension
• Missing
• Solder fillet
CONFIDENTIAL
INSPECTION CONDITION
Select the Algorithm and adjust the Inspect condition.
Each library component has Data Tabs. Select Pkg or Insp Cond and
select the inspection box and set the threshold values here.
CONFIDENTIAL
Defect Type and Setting
methods
INSPECTION CONDITION
Missing
Missing comp is
detected by
Volume and
Cad height.
Electrode crack
is detected with
Gray level
difference
CONFIDENTIAL
INSPECTION CONDITION
Pad overhang
Check the
offset difference
between CAD
and measured
value.
Two different
definitions are
available.
Center XY
option is often
use to detect
the center offset
difference.
CONFIDENTIAL
INSPECTION CONDITION
Body Coplanarity
Measure the
height of the
body at four
points.
Compare the
height
differences
along each axis
for X and Y.
CONFIDENTIAL
INSPECTION CONDITION
Lead Coplanarity
Measure the
height of the
Lead at one
point.
Compare the
height
differences.
CONFIDENTIAL
INSPECTION CONDITION
Solder Fillet
Measure the
volume of
solder joint or
height of the
solder joint at
the terminal or
lead toe.
3D:Volume or
Height
2D Steep:
Count the blue
pixel in the box
Bare copper:
Check for
copper color in
search area.
CONFIDENTIAL
INSPECTION CONDITION
Bridge
NG Case:
Cross Length: If
something is
longer than
setting value.
2D Color:
Something is
brighter than
Setting value.
3D Height:
Something is
higher than
Setting height.
String Value:
AND / OR
CONFIDENTIAL
INSPECTION CONDITION
Etc (OCV/R, Upside Down, Polarity, Electrode Crack)
OCV/R: Image
matching &
Pattern matching
Upside Down:
Check Gray value
for bright color.
Polarity:
Box: Check the
brightness of mark.
Dimple, Chamfer,
and Corner Case:
Measure height
change mode.
Crack Check:
Insp for crack on
the electrode with
Gray level
difference.
CONFIDENTIAL
Basic Procedure
PACKAGE (C & R CHIP) REGISTER AND BASIC TUNING
PKG Type Cop Image Algo Ins point Setting Order Detail Setting etc
1-1. Set the Body size( Width & Length) All inspection starts from this
1-2. Set the Electrode Size(Chip does not have Lead) point. If set proper comp size,
Chip
Body 1. PKG setting 1-3. Do "Component inspect and check the thickness of Body it means you would complete
Standard
and Lead.” programming around 70%.
1-4. Enter the Value of Width & Length & Thickness.
Body 3. Missing 3-1. Default value of Missing is set as 30%. Recommend is more than 80%
Body 4. Dimension 4-1. Length x Width x Height (Default is 50%~150%) Recommend is 80~130%
Body 5. PadOverhang 5-1. Select the mode(WCC, Center X&Y) (% or Metric)
CONFIDENTIAL
PACKAGE (TWO TERMINAL ) REGISTER AND BASIC TUNING
PKG Type Cop Image Algo Ins point Setting Order Detail Setting etc
1-1. Set the Body size( Width & Length) All inspection start s from this
1-2. Set the Electrode Size(Chip does not have Lead) point. If set proper comp size.
Standard Body 1. PKG setting 1-3. Do "Component inspect and check the thickness of Body It means you would complete
and Lead. programming around 70%.
1-4. Enter the Value of Width & Length & Thickness.
2-1. Select the Body location mode to Refer to Pre setting manual
Full 3D (Adaptive Height)
Body
2. Pre-setting 2-2. Set the Base Roi Expansion Edit. Component has two height
Lead
Mode: (Auto, Mouse, Keyboard) difference. So should use
2-3 Height Measure 75% Fixed height mode
Body 3. Missing 3-1. Default value of Missing is set as 30%. Recommend is more than 80%
Body 4. Dimension 4-1. Length x Width x Height (Default is 50%~150%) Recommend is 80~130%
Body 5. PadOverhang 5-1. Select the mode(WCC, Center X&Y) (% or Metric)
CONFIDENTIAL
PACKAGE (TWO TERMINAL ) REGISTER AND BASIC TUNING
PKG Type Cop Image Algo Ins point Setting Order Detail Setting etc
1-1. Set the Body size( Width & Length) All inspection start s from this
1-2. Set the Electrode Size(Chip does not have Lead) point. If set proper comp size.
Standard Body 1. PKG setting 1-3. Do "Component inspect and check the thickness of Body It means you would complete
and Lead. programming around 70%.
1-4. Enter the Value of Width & Length & Thickness.
2-1. Select the Body location mode to Refer to Pre setting manual
Full 3D (Adaptive Height)
Body
2. Pre-setting 2-2. Set the Base Roi Expansion Edit. omponent has two height
Lead
Mode: (Auto, Mouse, Keyboard) difference. So should use
2-3 Height Measure 75% Fixed height mode
Body 3. Missing 3-1. Default value of Missing is set as 30%. Recommend is more than 80%
Body 4. Dimension 4-1. Length x Width x Height (Default is 50%~150%) Recommend is 80~130%
Body 5. PadOverhang 5-1. Select the mode(WCC, Center X&Y) (% or Metric)
Lead 8. [Lead] coplanarity Set height above Lead thickness for detection. Selective
9. [Lead] pad
Lead Inward Lead Type No inspection
Overhang
Lead 10. [Lead] Bridge Inward Lead Type and Two terminal No inspection
Optional 11. OCV Select mode and choose proper illumination Add it
Optional 12 Polarity Select mode as a bar type. Choose proper illumination. Add it
Optional 13. Absence Verify NON-POP Location For no component.
CONFIDENTIAL
PACKAGE (TWO TERMINAL ) REGISTER AND BASIC TUNING
PKG Type Cop Image Algo Ins point Setting Order Detail Setting etc
1-1. Set the Body size( Width & Length) All inspection start s from this
1-2. Set the Electrode Size(Chip does not have Lead) point. If set proper comp size.
Standard Body 1. PKG setting 1-3. Do "Component inspect and check the thickness of Body It means you would complete
and Lead. programming around 70%.
1-4. Enter the Value of Width & Length & Thickness.
2-1. Select the Body location mode to Refer to Pre setting manual
Full 3D (Adaptive Height)
Body
2. Pre-setting 2-2. Set the Base Roi Expansion Edit. Component has two height
Lead
Mode: (Auto, Mouse, Keyboard) difference. So should use
2-3 Height Measure 75% Fixed height mode.
Body 3. Missing 3-1. Default value of Missing is set as 30%. Recommend is more than 80%
Body 4. Dimension 4-1. Length x Width x Height (Default is 50%~150%) Recommend is 80~130%
Body 5. Pad Overhang 5-1. Select the mode(WCC, Center X&Y) (% or Metric)
Lead
Overhang
10. [Lead] Bridge
No Lead Type
No Lead Type
No inspection
No inspection
Optional 11. OCV No character No inspection
Optional 12 Polarity Resistance band is required to inspect Add it
Optional 13. Absence Verify NON-POP Location For no component.
CONFIDENTIAL
REGISTER M.T(MULTI TERMINAL) AND BASIC TUNING
PKG Type Cop Image Algo Ins point Setting Order Detail Setting etc
Body 3. Missing 3-1. Default value of Missing is set as 30%. Recommend is more than 80%
Body 4. Dimension 4-1. Length x Width x Height (Default is 50%~150%) Recommend is 80~130%
Body 5. PadOverhang 5-1. Select the mode(WCC, Center X&Y) (% or Metric)
Lead 8. [Lead] coplanarity Not recommend when Lead top is covered by solder. Selective
9. [Lead] pad
Lead Not recommend when Lead top is covered by solder. Selective
Overhang
Lead 10. [Lead] Bridge Lead to lead is too wide Selective
Optional 11. OCV Select mode and choose proper illumination Selective
Optional 12 Polarity Select mode as a bar type. Choose proper illumination. Selective
Optional 13. Absence Verify NON-POP Location For no component.
CONFIDENTIAL
REGISTER M.L(MULTI LEAD) AND BASIC TUNING
PKG Type Cop Image Algo Ins point Setting Order Detail Setting etc
Body 3. Missing 3-1. Default value of Missing is set as 30%. Recommend is more than 80%
Body 4. Dimension 4-1. Length x Width x Height (Default is 50%~150%) Recommend is 80~130%
Body 5. PadOverhang 5-1. Select the mode(WCC, Center X&Y) (% or Metric)
Lead 8. [Lead] coplanarity Check the lead thickness first. Location of box is important. Required
9. [Lead] pad
Lead Not recommend when Lead top is covered by solder. Selective
Overhang
Lead 10. [Lead] Bridge Set the Cross length & 3D(Height) & 2D(Gray level) Required
Optional 11. OCV Select mode and choose proper illumination Selective
Optional 12 Polarity Select mode as a bar type. Choose proper illumination. Selective
Optional 13. Absence Verify NON-POP Location For no component.
CONFIDENTIAL
REGISTER M.L(MULTI LEAD) AND BASIC TUNING
PKG Type Cop Image Algo Ins point Setting Order Detail Setting etc
1-1. Set the Body size( Width & Length) All inspection start s from this
1-2. Set the Electrode Size(Chip does not have Lead) point. If set proper comp size.
Standard Body 1. PKG setting 1-3. Do "Component inspect and check the thickness of Body It means you would complete
and Lead. programming around 70%.
1-4. Enter the Value of Width & Length & Thickness.
Body 3. Missing 3-1. Default value of Missing is set as 30%. Recommend is more than 80%
Body 4. Dimension 4-1. Length x Width x Height (Default is 50%~150%) Recommend is 80~130%
Body 5. PadOverhang 5-1. Select the mode(WCC, Center X&Y) (% or Metric)
CONFIDENTIAL