The document describes an experiment to obtain the voltage-current (V-I) characteristics of a fluorescent lamp. The apparatus required includes a voltmeter, ammeter, fluorescent lamp, choke, starter, and auto-transformer. The procedure involves connecting the circuit and increasing the auto-transformer output voltage until the lamp lights up, recording meter readings at different voltages, and plotting graphs of voltage across the lamp versus current and voltage across the choke versus current. Precautions include making tight connections, using proper meter ranges, avoiding parallax error, and slowly increasing the auto-transformer voltage.
The document describes an experiment to obtain the voltage-current (V-I) characteristics of a fluorescent lamp. The apparatus required includes a voltmeter, ammeter, fluorescent lamp, choke, starter, and auto-transformer. The procedure involves connecting the circuit and increasing the auto-transformer output voltage until the lamp lights up, recording meter readings at different voltages, and plotting graphs of voltage across the lamp versus current and voltage across the choke versus current. Precautions include making tight connections, using proper meter ranges, avoiding parallax error, and slowly increasing the auto-transformer voltage.
The document describes an experiment to obtain the voltage-current (V-I) characteristics of a fluorescent lamp. The apparatus required includes a voltmeter, ammeter, fluorescent lamp, choke, starter, and auto-transformer. The procedure involves connecting the circuit and increasing the auto-transformer output voltage until the lamp lights up, recording meter readings at different voltages, and plotting graphs of voltage across the lamp versus current and voltage across the choke versus current. Precautions include making tight connections, using proper meter ranges, avoiding parallax error, and slowly increasing the auto-transformer voltage.
Aim: To obtain the V-I characteristics of a Fluorescent Lamp. Apparatus required: S.No Name of the Range/ Type Quantity equipment Specification 1 Voltmeter (0-300) V MI 3 2 Ammeter (0-1) A MI 1 3 Fluorescent lamp 36W, Discharge 1 4 Choke 230V, 40W Core type 1 5 Starter 20-65 W, Glow- 1 1-ɸ, (230-250)V, Type 6 1- Phase Auto I/P: 1-ɸ, 230V Core type 1 Transformer O/P: (0-270)V,10A 7 Connecting wires 1.5 Sq.mm Copper Required
Procedure:
1. Connect the circuit as per circuit diagram.
2. With the autotransformer at zero output position, close the DPST switch. 3. Increase the output voltage of the autotransformer in steps until the lamp lights up. Note down the meter readings. 4. When the lamp starts to glow, increase the autotransformer output voltage until the rated voltage of the lamp is obtained i.e.230V, enter the readings of the meters in Tabular column. 5. Decrease the supply voltage in steps until the lamp extinguishes. At each step record the meter readings. Circuit Diagram: Tabular column: S VS IL V Choke V Lamp Lamp No (Volts) (Amps) (Volts) (Volts) condition Incr Decr Incr Decr Incr Decr Incr Decr Incr Decr
Vs = Supply Voltage, VL = Voltage across the lamp
VC = Voltage across the choke, IL = Current through the lamp
Graph : Plot the graph (VL vs IL) & (VC vs IL).
Precautions:
1. All the connections should be tight
2. Use proper ranges of the meters. 3. Take the readings without parallax error. 3. All the connections should be tight. 4. Increase the output voltage of the auto transformer very slowly while starter / lamp is blinking.