CLIENT:
C:\Users\mahmoud_abdelkhalek\Documents\2970_ECG-B02-RVT-S_Mahmoud_Abdelkhalek.rvt
1 2 3 4
B1 B1 B1 B1
171550
300
LEAD CONSULTANT:
1000
1000 250
6650
TOC 100.650
1000
1000
2000 300
B1 A B1 A
1000
1000
Q Q
2000
500
500
1000 1000
1000 1000 1000 1000 SUB-CONSULTANT:
8585
8585
8185
8185
350 350 350 350
300
300
500 500
500 8185 8185 8185 8185 500
P P
350 350
8035
8035
8335
8335
NOTES:
TOC 104.500 TOC 104.500
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVLES ARE IN METERS
B1 C B1 C
UNLESS OTHERWISE NOTED.
2. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH RELEVANT
300
300
ARCHITECTURAL,CIVIL, MECHANICAL AND ELECTRICAL ENGINEERING
SERVICES DRAWINGS.
350 350 3. ALL DIMENSION ARE TO BE CHECKED AND VERIFIED BY THE
8335
8035
8035
8335
N CONTRACTOR PRIOR TO THE COMMENCEMENT OF CONSTRUCTION N
TOC 104.500 1000 1000
TOC 104.500 ON SITE & THIS DRAWING MUST NOT BE SCALED AND ONLY WRITTEN
OR CALCULATED DIMENSIONS ARE TO BE USED.
1000
1000
4. THE CONCRETE CYLINDER STRENGTH IS 32 N/MM2 AT 28 DAYS &
50510
50510
B1 D B1 D THE REINFORCEMENT STEEL YIELD STRENGTH IS 420 N/MM2
300
300
8035
8035
8335
7. THE DENSITY OF THE LIGHT WEIGHT CONCRETE PLACED ON THE
M TOC 104.500 TOC 104.500 TANK'S RAFT TO ACHIEVE THE REQUIRED SLOPES SHALL NOT EXCEED M
1000 1000
12KN/M3.
1000
1000
B1 E B1 E
300
300
350 350
8035
8035
8335
8335
500 500 TOC(100.650)
500 8185 TOC 104.500 8185 8185 TOC 104.500 8185 500
L 250MM THICK. L
B1 F B1 F
300
300
TOC(104.500)
350 350
8185
8185
8585
8585
1000 TOC 104.500
1000 1000
TOC 104.500 1000
350MM THICK.
1000
1000
1000
1000
K B1 G B1 G
TOC(105.100) K
500
500
85500 550 85500
350MM THICK.
171550
1
J3
ROOF FLOOR FRAMING PLAN 2 3 4
B1 B1 B1 B1
1 : 200
J 1
B1
2
B1
3
B1
4
B1
J
171550
T12-125 TOP
250
H H
T16-125 BOT
TOC 100.650
B1 A B1 A
8585
350 T16-125 BOT 350 350 T16-125 BOT
350
G L =6000
T12-125 TOP T12-125 TOP
L =6000 G
13500
13500
TOC 104.500 T16-125 BOT T16-125 BOT TOC 104.500
77800 77800
B1 B B1 B
T16-250
T16-250
L =6000
L =6000
350 T12-250 T12-250 350
8335
8335
L =6000 L =6000
T12-125 TOP T12-125 TOP
TOC 104.500 TOC 104.500
13500
13500
T16-125 BOT T16-125 BOT
F F
77800 77800
13-Feb-22 3:17:54 PM
B1 C B1 C KEY PLAN
T16-250
T16-250
L =6000
L =6000
350
350
8335
8335
T12-125 TOP
T12-250 T12-125 TOP T12-250
TOC 104.500 T16-125 BOT TOC 104.500
L =6000 T16-125 BOT L =6000
77800 77800
50510
50510
E B1 D B1 D
E
13500
13500
T16-250
T16-250
L =6000
L =6000
350 350
SHEET SIZE - ISO A0 (841* 1189 MM)
8335
8335
T12-125 TOP T12-250 T12-250 T12-125 TOP WATER TANK
ZONE 2A
TOC 104.500 T16-125 BOT L =6000 L =6000 T16-125 BOT TOC 104.500
13500
13500
77800 77800
B1 E B1 E
T16-250
T16-250
L =6000
L =6000
D D
350 350
8335
8335
T12-250 T12-125 TOP T12-125 TOP T12-250
L =6000 TOC 104.500 T16-125 BOT T16-125 BOT TOC 104.500 L =6000
77800 77800
B1 F B1 F
13500
13500
T16-250
T16-250
L =6000
L =6000
350 350
8585
8585
T12-125 TOP T12-125 TOP
RIYADH SEDRA 02
PROJECT DATA
TOC 104.500 T16-125 BOT T16-125 BOT TOC 104.500
RIYADH, KSA
B1 G B1 G
WATER TANK
B 171550 B
PROJECT
NORTH 1.7-SUPERSTRUCTURE REINFORCEMENT PLANS
1 2 3 4 30.00°
SCANNING SCALE
B1 B1 B1 B1
TRUE NORTH STRUCTURAL REINFORCEMENT PLANS
ROOF FLOOR RFT. PLAN
A3 COMPANY TOWNSHIP PROJECT/ PHASE CONTRACT ORIGNATOR STAGE DISCIPLINE BUILDING DRAWING SEQUENCE REV.
10 mm
THIS DRAWING AND THE DESIGN IT COVERS ARE THE PROPERTY OF THE ENGINEERING CONSULTANTS GROUP .THEY ARE MERELY LOANED ON THE BORROWER'S EXPRESSED AGREEMENT THAT THEY WILL NOT BE REPRODUCED, COPIED, LOANED, EXHIBITED NOR USED EXCEPT FOR LIMITED AND PRIVATE USE PERMITTED BY WRITTEN CONSENT GIVEN BY THE LENDER TO THE BORROWER.