You are on page 1of 1

TỦ ĐIỆN TRẠM SẠC TĐ.

TSXĐ
TỪ TRẠM BIẾN ÁP TBA MỚI CẤP ĐẾN
CÁP CẤP NGUỒN CU/XLPE/PVC (3x1Cx240)+(1CX120)MM2+E120MM2
/SOURCE CABLE LUỒN TRONG 01 ỐNG HDPE D195/150, CHÔN NGẦM

CHỈ THỊ
CC TĐ.TSXĐ
3x2A (1600x800x500)mm

TỦ ĐIỆN LOẠI LẮP NGOÀI TRỜI


MCCB
MÁY CẮT TỔNG
3P
/ MAIN CB
400A
50kA
Pđ = 185 kW , Kđt = 0.9
THANH CÁI Ptt = 167 kW
/ BUS BAR

MÁY CẮT LỘ RA MCCB MCCB MCCB RCBO MCB MCB MCB


4P 4P 4P 2P 1P 1P 1P
/ OUTGOING CB
175A 175A 175A 16A 10A 10A 20A
42kA 42kA 42kA 6kA 6kA 6kA 6kA
30mA
ĐIỀU KHIỂN
/ CONTROL

LỘ RA / OUT CODE

Cu/XLPE/PVC (3Cx50+25)mm2+E(1x25)mm2 ® ¾

Cu/XLPE/PVC (3Cx50+25)mm2+E(1x25)mm2

Cu/XLPE/PVC (3Cx50+25)mm2+E(1x25)mm2

Cu/PVC/PVC (2x2.5)+E(1x2.5)mm2

Cu/PVC/PVC (2x2.5)+E(1x2.5)mm2

Cu/PVC/PVC (2x2.5)+E(1x2.5)mm2
CHÔN NGẦM, ỐNG HDPE D85/65

CHÔN NGẦM, ỐNG HDPE D85/65

CHÔN NGẦM, ỐNG HDPE D85/65

CHÔN NGẦM, ỐNG HDPE D32/25

CHÔN NGẦM, ỐNG HDPE D32/25

CHÔN NGẦM, ỐNG HDPE D32/25


CÁP NGUỒN/
CÁCH LẮP ĐẶT
CABLE /
HOW TO INSTALL

PHA ABC ABC ABC A B C A


/PHASE
CẤP NGUỒN HỆ THỐNG ĐIỆN NHẸ
TRỤ SẠC DC 60KW ( TRỤ 1)

TRỤ SẠC DC 60KW ( TRỤ 2)

TRỤ SẠC DC 60KW ( TRỤ 3)

PHỤ TẢI
BIỂN NHẬN DIỆN

/LOAD
CHIẾU SÁNG

DỰ PHÒNG

CÔNG SUẤT (kW) /CAP (kW) 60.0 60.0 60.0 - - - -

GHI CHÚ:
- CÁP TRUNG THẾ TỪ ĐIỂM ĐẤU NỐI ĐIỆN LỰC ĐẾN TRẠM BIẾN ÁP XÂY MỚI TẠM TÍNH 250M,
SỐ LƯỢNG CHÍNH XÁC THEO THỰC TẾ THI CÔNG
- KÍCH THƯỚC TỦ ĐIỆN PHÂN PHỐI TRẠM SẠC XE SẼ ĐƯỢC CẬP NHẬT
THEO THỰC TẾ THIẾT BỊ NHÀ THẦU CHẾ TẠO
- KÍCH THƯỚC TỦ ĐIỆN PHÂN PHỐI SẼ ĐƯỢC THAY ĐỔI THEO THIẾT BỊ NHÀ THẦU SẢN XUẤT
- ĐỐI VỚI TRẠM SẠC CẤP ĐIỆN TỪ ĐIỆN LỰC THÌ KHÔNG CẦN TRANG BỊ CÔNG TƠ ĐIỆN
- CHI TIẾT TRẠM BIẾN ÁP XEM HỒ SƠ TRẠM BIẾN ÁP
- CẤU HÌNH THAY ĐỔI THEO THỎA THUẬN ĐẤU NỐI VÀ YÊU CẦU ĐIỆN LỰC ĐỊA PHƯƠNG