You are on page 1of 32

iT500 Internet Thermostat

INSTALLER MANUAL
1. Product compliance & safety information

These instructions are applicable to the SALUS Controls model stated on the front cover of this manual
only, and must not be used with any other make or model.

This accessory must be fitted by a competent person, and installation must comply with the guidance
provided in the current IEE Wiring Regulations and current Building Regulations. Failure to comply with
the requirements of these publications could lead to prosecution.

Always isolate the AC Mains supply before installing or working


on any components that require 230 VAC 50Hz supply.

When fitting batteries, do not mix old and new batteries together.
Do not use rechargeable batteries.

Please leave these instructions with the end user where they should be kept in a safe place for future
reference.

02 iT500 Installer Manual


2. Installation of the iT500RX Receiver

1 2 3

Loosen the screws at the bottom Unclip the front of the unit. Fit the back of the receiver unit to the wall
of the receiver unit. using the fittings supplied.

4 5 6

Wire up the receiver using one of the Clip the front of the unit back on by aligning the Securely screw the front of the receiver in place.
schematics on pages 4 and 5 fittings and pushing into place.

iT500 Installer Manual 03


3. WIRING SCHEMATICS FOR SYSTEM CONFIGURATIONS

A Volt Free - Combination Boiler


C 2 x CH Zones - Volt Free Combination Boiler

BOILER

230V 230V BOILER


0V
230V

OV - 230v
230
B 230V Switching - Combination Boiler

A One central heating zone only.


BOILER

B One central heating zone only.


230V
C Two central heating zones. +
230V
iT300 Sensor required for this configuration.

04 iT500 Installer Manual


3. WIRING SCHEMATICS FOR SYSTEM CONFIGURATIONS
D 230 V Switching - S Plan F 230 V Switching - Y Plan

C 2

2 1 C
230V
230V
230V 230V
230V 230V BOILER BOILER

Permanent
230V
230
230

E 2 x CH Zones - 230 V Switching Combination Boiler

D One central heating zone +


plus hot water.
E Two central heating zones. +
230V
iT300 Sensor required for this configuration.
230V 230V BOILER

F One central heating zone +


Permanent
plus hot water.
230

230

iT500 Installer Manual 05


4. Installation of wall bracket docking (optional)
1 2 3

Attach the wall mounting bracket to a After first ensuring that the bracket Once clipped into place, ensure the unit is
suitable wall using the fittings supplied is secure, clip the iT500 into place by securely seated on the bracket.
and the built in level. aligning the recess on the back of the unit
For best results mount the
to the bracket and clipping into place.
i iT500 1.5m from ground level.

5. Desk mount option iT500

For the desk mounted option, simply clip


the clear stand supplied separately into
06 iT500 Installer Manual the back of the unit.
6. Connecting the Gateway to your existing router

Flashing red light


on setup.

i You require port 80 and 2165 UDP open on the router Constant green light when the iT500 is
connected to the SALUS Controls Server.

iT500 Installer Manual 07


7. Inserting the batteries in the iT500 Thermostat

1 2 3

Remove the battery cover from Make a note of the serial number printed With the unit face down, insert the first
the base of the iT500 Thermostat. in the base of the iT500 Thermostat. battery supplied into the right hand side
of the base of the iT500 Thermostat.

4 5 6

Insert the second battery supplied into the left Ensure the batteries are fitted securely Replace the battery cover to the
hand side of the base of the iT500 Thermostat. in the base of the iT500 Thermostat. base of the iT500 Thermostat.

Why not make a note of your STA


number here for future reference. S T A

08 iT500 Installer Manual


8. Setting up the iT500 Thermostat
After powering up iT500 for the first time the display will go through the following sequence.

1 4

OTA* Revision number

2
The globe icon will appear when the unit
automatically connects to the internet via the
SALUS iTG500 Gateway.
This should take approximately 20 seconds. i
* Over The Air operated software

iT500 Software revision

iT500 Installer Manual 09


9. LCD Overview
LCD ICONS DESCRIPTION FUNCTION
Day of the week Displays the number of the day of the week. 1 being Monday
Temperature indicator Displays set or measured temperature
Clock display Displays time
Program number indicator Displays the number of the active (selected) program
Heat mode indicator Indicates heating output is turned on*
OR Heat zone indicator Indicates heating zone*
Hot water indicator Indicates hot water control*
Hot water mode indicator Indicates hot water output is turned on*
RF signal indicator Indicates the unit is transmitting a wireless signal to the
iT500RX or is receiving the signal from the iT300*
Touch lock indicator Indicates touch lock is activated
Battery status Indicates battery is low
Holiday indicator Indicates holiday operation mode is selected
Internet indicator Indicates connection to iTG500 and SALUS server
Cooling indicator Indicates cooling output is on*
ON indicator Hot water continuously on*
Once indicator Hot water is on once*
AUTO indicator Automatic program mode
OFF indicator Off mode
Setting indicator Manual override or settings mode

* System configuration specific.


10 iT500 Installer Manual
Selecting
your system
configuration
OR
Based on your system
wiring on page 4.
B
i
If the iT500 is to be used
in the UK for single zone
heating then there is no
need to enter system
C
configuration setup, please
proceed to page 15. i
A B C
i See page 12
Note! This menu should
only be entered by the
installer as changes can
have a detrimental effect OR

on your heating system.


A
i
At any time press and hold
for 5 seconds to
return to the home screen.
iT500 Installer Manual 11
Now that you have selected your system configuration you can continue with the rest of the installation setup.
A B + C +

OR OR OR

Select for heating application Select for heating application Select for heating application

Select for cooling application* Select for cooling application* Select for cooling application*

OR OR OR

Centigrade to Fahrenheit Centigrade to Fahrenheit Centigrade to Fahrenheit

GMT Time setting** GMT Time setting** GMT Time setting**


12 iT500 Installer Manual * Cooling can only be selected if your system supports this.
** Please refer to the following page for your region.
10. European Time Zones
GMT GMT+1 Hour GMT+2 Hour GMT+3 Hour

UK AUSTRIA BELGIUM ESTONIA BULGARIA RUSSIA*


IRELAND POLAND DENMARK TURKEY LITHUANIA
PORTUGAL GERMANY SWEDEN CYPRUS BELARUS*
ICELAND* CZECH NORWAY GREECE FINLAND
SPAIN MALTA ROMANIA MOLDOVA

i FRANCE
ITALY
SWITZERLAND
CROATIA
SERBIA
BOSNIA
RUSSIA
UKRAINE
LATVIA

The countries marked with * do not LUXEMBOURG SLOVENIA


observe Daylight Saving Time HOLLAND iT500 Installer Manual 13
Now that you have selected your system configuration you can continue with the rest of the installation setup.
DST (daylight saving time) ON will automatically change your time from summer to winter.
A B + C +

OR OR OR

11. Pairing the iT500 with the iT500RX Receiver

14 iT500 Installer Manual


1 2 3

Using a paper clip, insert into the hole The bottom switch will show a constant red
marked SYNC at the bottom of the light when the iT500RX Receiver is ready to
iT500RX Receiver. Then work through the pair. Now go to the iT500 Thermostat.
screen sequence shown on the next page.

4 5 6

When the iT500RX Receiver and the iT500 Thermostat


i are paired then the light will be green.
FAILSAFE MODE: In the event of RF signal loss, your system will be Press OR
switched on for 4 minutes, then off for 11 minutes. If you want to
to return to home screen.
disable FAILSAFE MODE when RF link has been lost then move the
slide switch on the iT500RX to either the manual or off position.
iT500 Installer Manual 15
Receiver LED colours

The bottom switch will show a constant red When the iT500RX Receiver and the iT500
light when the iT500RX Receiver is ready to Thermostat are powered and paired then the
pair. light will be green.

Flashing blue light indicates a heat call/Hot FAILSAFE MODE: In the event of RF signal
water call loss, your system will be switched on for 4
minutes, then off for 11 minutes. If you want
to disable FAILSAFE MODE when RF link has
been lost then move the slide switch on the
iT500RX to either the manual or off position.
16 iT500 Installer Manual
i
12. Fitting the wall bracket and mounting the iT300 Used for 2
central heating
Note: iT300 purchased separately. Can only be used if your
system supports two central heating zones. See pages 4 and 5.
zones only

1 2 3

Remove the battery cover on the back of Insert the 2x AAA batteries supplied into Replace the battery cover.
the iT300 unit. the iT300 unit.

3 4 5

Attach the wall mounting bracket to a Align the grooves on the back of the iT300 Once in place, ensure the unit is securely
suitable wall using the fittings supplied. unit and slide onto the bracket. seated on the bracket.

iT500 Installer Manual 17


13. Pairing the iT300 to the receiver

1 2 3

To pair the iT300 to the receiver, insert a A red light will flash in the top right
paperclip or similar object into the hole on hand corner of the iT300.
the left hand side of the iT300 for 2 seconds.

4 5 6

The iT500 has successfully paired with the


iT300 when the antenna stops flashing.
Press OR

i The iT300 should be installed in the area of the house that to return to home screen.
the second zone will be controlled from, ie. Upstairs. Please note the red LED on the iT300 will
continue to flash and eventually timeout.

18 iT500 Installer Manual


14. Registering and operating your iT500 online
1

Go to the SALUS controls website. www.salus-controls.com and select your relevant country

© Salus Controls 2012 Privacy Policy Disclaimer Site Map

Click on the register iT500 icon on the left hand side of your country’s website

iT500 Installer Manual 19


14. Registering and operating your iT500 online
3 4

Click on REGISTER Fill in the online form and click REGISTER

The above screen will show and a confirmation email will be sent to you

20 iT500 Installer Manual


14. Registering and operating your iT500 online
6 7

You will receive a confirmation email. Click


on the link to complete your registration.

© Salus Controls 2012 Privacy Policy Disclaimer Site Map

Now use your username and password to log in.


8 9

© Salus Controls 2012 Privacy Policy Disclaimer Site Map © Salus Controls 2012 Privacy Policy Disclaimer Site Map

Enter the iT500 STA number (Please refer to page 8). Then press REGISTER. Your iT500 will appear as above and is now ready to be controlled or viewed
via your PC or Smartphone. Just click on the iT500 icon on your PC.
iT500 Installer Manual 21
15. Download Smartphone App
Once you have registered your iT500 online you can also download the smartphone App from the iPhone App Store or the Android App
Store depending on which kind of Smartphone you are using. Find the iT500 App on the App Store and click download. The App will
automatically download to your Smartphone and once downloaded you can begin controlling your iT500 Thermostat.

www.salus-controls.com Go to the salus-controls.com website.

Click on the relevant App Store Icon.

Find the SALUS iT500 App and click download.

22 iT500 Installer Manual


16. Adding or renaming the iT500 in your device list

Enter your user ID and password. When you first open the iT500 App If you add more than 1 iT500 to your If you forget your password, follow
Press your iT500 will appear in the device device list, you may wish to rename the on screen instructions.
list and you can begin controlling it the iT500 to “DOWNSTAIRS” for
with your Smartphone. example. Click on
and enter a new name.

i
For full information on PC and Smartphone
operation please refer to the user manual.

iT500 Installer Manual 23


Trouble shooting
Q. Can I operate the heating using the iT500 unit if I have no internet connection?
A. Yes, most functions can be operated from the iT500 unit.
Q. Why do my iT500 buttons not work?
A. Check that the screen lock is not active. If active, there will be a padlock visible in the top of the LCD. Disable
by pressing and holding top two left keys on the iT500.
Q. Why does my heating never come on?
A. Check that the iT500 is in AUTO mode, ‘AUTO’ should be visible at the bottom right on display. If showing
‘OFF’ press the TICK and SETTINGS buttons, then use the UP/DOWN arrow keys to change OFF to AUTO then
TICK to confirm.
Q. I’ve tried doing the software upgrade (Green Button appeared on the iT500 web page) but it failed...
A. Check the gateway is plugged into the router and it has a green light.
A. Position the iT500 within 1 meter of the SALUS Gateway unit.
A. If you receive the message ‘Failed’ please try running the OTA again.
(Due to internet speed this may take several attempts)
Q. Where do I download my Smartphone app to control the iT500?
A. If you have an iPhone, please search for iT500 on the app store, if you have an Android; search for iT500
on Google play.
Q. What does the Smartphone App do?
A. It lets you control the iT500 remotely over the internet. You have full remote access to your heating
control giving both temporary and program changes.

24 iT500 Installer Manual


Trouble shooting
Q. I can’t access my iT500 on my PC or Smartphone after registering it?
A. Check you received your confirmation email from SALUS and clicked on it.
A. Check you entered the correct email and password as used on registration.
A. Ensure you added your device STA number which is located in the battery compartment of the iT500.
You should see an image of your device after log-in, click on it to access.
Q. I have installed the device and registered online but my heating is not coming on.
A. Check that the top slide switch on the receiver unit is in the AUTO position.
A. Perform a quick installation check by putting the top slide switch to Manual position, and the bottom
slide switch to CH. The boiler should fire, if not the iT500 receiver may be wired incorrectly. Please contact
your installer.
Q. My receiver has a flashing blue light... what is that?
A. A flashing Blue light is normal indication that the iT500 thermostat is asking for heat and the boiler
should be on.
Q. My receiver has a flashing Yellow light... what is that?
A. A flashing Yellow light is fault indication. The iT500 receiver unit has lost communication with the
thermostat. Check the thermostat distance from its receiver, and check for major metalwork in its
communication path (such as fridge/freezers). Reposition the thermostat to improve communication.
Once it establishes communication again the fault will clear automatically.

iT500 Installer Manual 25


Trouble shooting
Q. The App says my iT500 is OFFLINE and my iT500 does not have the internet globe indicator on the
screen, why is this?
A. Check that you have the power supply turned ON to the gateway and it has a steady green light showing.
The green light indicates you are connected to the SALUS server.
A. If you have all the above, remove a battery from the iT500 and replace after 10 seconds. This will reboot the
iT500 and bring you back online.
Q. I’ve just plugged the SALUS gateway into my Belkin and the gateway has a solid RED light,
what is this?
A. The gateway must be connected to a network that has DHCP enabled, it must be connected to a network
that has the firewall ports 80 (UDP/TCP) and 2165 (TCP) open. (You may need to contact your internet provider
to assist you changing your router settings.)
Q. I have a new BT Hub 5 router and the gateway has a solid red light.
A. BT Hub 5 uses ports 3 and 4.
Q. Just had the iT500 installed and my heating isn’t coming on?
A. Have you paired the thermostat with the receiver, please see page 15 in the installer manual on how to do this.

26 iT500 Installer Manual


17. Warranty
SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall
perform in accordance with its specification, for a period of two years from the date of installation. SALUS Controls
sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.

Customer Name: .............................................................................................................................

Customer Address: ..........................................................................................................................

............................................................................... Post Code: ........................................................

Tel No: ........................................................ Email: .........................................................................

Engineers Company: .......................................................................................................................

Tel No: ......................................................... Email: ........................................................................

Installation Date: ..........................................................................................................................

....

Engineers Name: ............................................................................................................................

iT500 Installer Manual 27


SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road,
Dodworth, Barnsley S75 3SP
UK.
SALES: T: +44 (0) 1226 323961
E: sales@salus-tech.com
TECHNICAL: T: +44 (0) 1226 323961
E: tech@salus-tech.com

www.salus-controls.com

SALUS Controls is a member of the Computime Group


Maintaining a policy of continuous product development SALUS
Controls plc reserve the right to change specification, design and
materials of products listed in this brochure without prior notice.
Issue Date: Sept 2013

00086/2
Introducere O zonă Instalare. Pasul 2 - Termostat
2a Cazan cu contacte fără potențial de încălzire
SALUS iT500 este un termostat programabil, controlabil prin internet, cu opțiuni
pentru controlul apei calde (cu boiler extern) sau a două zone de încălzire 1
(necesită senzorul iT300).

Conformitatea produsului

iT500 Termostat cu
BOILER
Acest produs este în conformitate cu următoarele directive europene: EMC 2014/30/EU,
LVD 2014/35/EU, RED 2014/53/EU și RoHS 2011/65/EU. Textul integral al Declarației de
Conformitate UE este disponibil la urmatoarea adresa de internet: www.saluslegal.com
comandă prin internet 868.0-868.6MHz; <13dBm

Informații de siguranță
0V
230V S T A -
Utilizați în conformitate cu reglementările UE și reglementările naționale. Numai O zonă Înainte de introducerea bateriilor, vă rugăm să notați numărul STA, deoarece veți
pentru utilizare în interior. Mențineți dispozitivul complet uscat. Deconectați avea nevoie de acesta pentru înregistrarea dispozitivului pe aplicație.
echipamentul înainte de a îl curăța cu un prosop uscat. 2b Cazan cu conexiune 230V
230V Switching - Combination Boiler
de încălzire

Deconectați dispozitivele de la sursa de alimentare, înainte de a lucra la


oricare dintre componentele care necesită 230V. 2
Funcțiile butoanelor BOILER

230V
230V

Asocierea termostatului cu receptorul


1 4 O zonă
2c Conexiune 230V - Plan S de încălzire
1a 1b
+
2 Control A.C.M
5

3 6 sau
Ghid de instalare
C 2

230V

230V 230V BOILER

1 Confirmați opțiunea și treceți la ecranul următor. 2 3


V003
Data publicării: Noiembrie 2018 Permanent
2 Mergeți la ecranul anterior sau țineți apăsat pentru a reveni 230V
la ecranul principal.
230

3 Accesați meniul Setări.


www.saluscontrols.ro O zonă
Pentru ghidul de instalare în format PDF, vă rugăm accesați:
4 Mergeți în sus sau navigați printre opțiuni. 2d Conexiune 230V - Plan Y de încălzire
+
Control A.C.M
enumerate în această broșură fără notificare prealabilă. 5 Atunci când butonul este apăsat, ecranul LCD se luminează.
rezervă dreptul de a modifica specificațiile, design-ul și materialele produselor Se introduce o agrafa de hârtie în LED-ul roșu va indica faptul că
Menținând politica de continuă dezvoltare a produsului, SALUS Controls își gaura marcată SYNC. receptorul este gata pentru
6 Mergeți în jos sau navigați printre opțiuni.
asociere.
SALUS Controls este membru Computime Group
4 5
i Pentru a accesa Meniul Setări, apăsați
simultan butoanele următoare:

Instalare. Pasul 1 - Receptor


Apăsați Apăsați
www.saluscontrols.ro 1
6 7
3

E: tehnic@saluscontrols.ro
T: 0364 435 696

România Apăsați sau pentru


Cluj-Napoca a reveni la ecranul principal.
Strada Traian Vuia 126
SALUS Controls România SRL Montați și conectați receptorul folosind următoarele Cand receptorul și termostatul
diagrame electrice: sunt asociate, LED-ul va fi verde.
Instalare. Pasul 3 - Gateway TPI Pornire optimizată

6 7 TPI este un algoritm avansat care are rolul de a menține temperatura ambientală cât mai aproape de
Pornire optimizată este o 1
valoarea dorită de utilizator. Algoritmul evaluează în mod permanent orice fluctuații de temperatură
care apar și pornește/oprește încălzirea într-o manieră proactivă, pentru a preveni abaterile nedorite ale funcție prin care termostatul se
temperaturii. Prin faptul că reduce supraîncălzirea aerului din încăperi, TPI poate aduce o economie de adaptează treptat la mediul în
energie și un plus de comfort. care este instalat. Spre exemplu,
când programele de încălzire
stabilite de dvs. includ fluctuații
Nu activați TPI atunci când sursa de căldură este un echipament pentru care nu se recomandă mari de temperatură, această
porniri/opriri frecvente (ex. cazane pe peleți, centrale termice de putere mare). Pentru centrale murale se funcție permite termostatului
recomanda cel mult TPI cu 6 cicluri pe ora. să pornească încălzirea în avans,
pentru a se asigura ca obtineti
temperatura dorită în cel mai
Operațiuni generale scurt timp de la activarea unui
program (interval) nou.
Există 3 setări ale programelor: Pornire optimizată este activată
1. Automat (7 zile, 5-2 zile, 24 ore); 2. Manual; 3. Oprit. în mod implicit. Pentru a
dezactiva funcția, folosiți pașii
1. Automat următori.

2 3
Conectați Gateway-ul la router. Gateway-ul este conectat la serverul de comandă
Salus atunci când LED-ul este verde. Setări ale termostatului prin aplicație

Funcții disponibile în aplicație:


Înregistrare
• Formatul temperaturii • Pas de afișaj
• Formatul ceasului • Calibrare temperatură
Descărcați aplicația iT500 Plus, creați-vă un cont și înregistrați-vă produsul. • Fusul orar • Modul Automat/Manual/Off
Urmariți indicațiile de pe ecran pentru a parcurge toți pașii. • Ora de vară/iarnă • Modul de Vacanță
• Modul Încălzire/Răcire • Mod Locație
• Interval de temperatură • Pornire amânată

1 iT500 Plus iOdată ce simbolul


1 2
apare pe ecranul
LCD, termostatul TOATE 5/2 INDIVIDUAL
este online și poate fi Setați un program Setați un program Setați un program zilnic
adaugat pe aplicație. pentru toată săptămâna pentru zilele lucrătoare (diferit pentru fiecare zi).
(același in fiecare zi). și altul pentru weekend.

Protecție anti-îngheț
2. Manual
2 3
În modul manual nu se va ține cont de 1
programul stabilit. Anulați modul manual
setând Modul Automat sau cel Oprit. Temperatura poate fi setată în
intervalul 5-9 °C.

3. Oprit Pentru a activa funcția de


Protecție anti-îngheț, selectați
Modul Vacanță sau cel Oprit
Când termostatul este oprit, funcție de folosind aplicația.
Protecție Anti-îngheț este activată în mod
implicit.

3 4
Mod Locație

Modul Locație este o funcție Dacă Modul Locație este


automată care poate schimba activat, puteți muta butonul
setările de încălzire în funcție glisant pentru a seta limita
de distanța dvs. față de casă. distanței.

4 5 1 2 2 3

Personalizați setările în funcție de preferințele dumneavoastră. Ora și


data se vor actualiza automat odată ce sunteți conectat la internet.
Setați modul (încălzire/răcire). Modul Încălzire este folosit pentru a
controla un cazan. Modul Răcire este folosit pentru a controla un sistem
de răcire. În Modul Răcire, puteți alege un interval de temperatură între
± 0.5 °C și ± 0.25 °C. În Modul Încălzire, puteți alege pe deasupra între un
nivel de confort scăzut (TPI - 6 cicluri pe oră) și un nivel de confort sporit
(TPI - 9 cicluri pe oră). De asemenea, pentru a calibra temperatura,
puteți folosi un interval de ± 3 °C.
Salus iT500. Ghid rapid pentru actualizarea versiunii de firmware
O nouă versiune de software este disponibilă pentru termostatul Salus iT500. Aceasta activează următoarele funcții noi:
w w w.saluscontrols.ro
- Modificarea histerezei de la +/- 0.5 °C la +/- 0.25 °C – asigură reducerea fluctuațiilor temperaturii ambientale;
- Modificarea pasului de afișare a temperaturii: temperatura va fi afișată cu pași de 0.1°C (în locul valorii standard de 0.5°C); Tel: 0364 435 696
E-mail: office@saluscontrols.ro
- Calibrarea temperaturii afișate în funcție de influențe externe. Temperatura afișată poate fi ajustată cu până la +/- 3°C.

Actualizare firmware Setări

1 2 3 4 1 2 3 4

iT500 Plus

Asigurați-vă că aveți ultima


versiune a aplicației descărcată
din Google Play Store sau Apple
Apăsați simbolul meniu. Apăsați “Administrare Apăsați “OK”. Apăsați simbolul meniu. Apăsați “Setări”. Alegeți chenarul din dreptul Alegeți o opțiune și apăsați
App Store.
dispozitive”. “Precizia temperaturii”. “OK”.

5 6 7 8 5 6 TPI – este un algoritm avansat care are rolul de a menține temperatura


ambientală cât mai aproape de valoarea dorită de utilizator. Algoritmul
evaluează în mod permanent orice fluctuații de temperatură care apar
și pornește/oprește încălzirea într-o manieră proactivă, pentru a preveni
abaterile nedorite ale temperaturii. Prin faptul că reduce supraîncălzirea
aerului din încăperi, TPI poate aduce o economie de energie și un plus de
comfort.
Important: NU activați TPI atunci când sursa de căldură este un echipament
pentru care nu se recomandă porniri/opriri frecvente (ex. cazane pe peleți,
centrale termice de putere mare). Pentru centrale murale se recomanda cel
mult TPI cu 6 cicluri pe ora.
Calibrarea temperaturii – este o funcție care permite utilizatorului să ajusteze
temperatura afișată de termostat, pentru a compensa anumiți factori. Spre
exemplu, daca amplasați termostatul mai jos decat înălțimea optimă (1.5m),
puteți calibra temperatura citită astfel încât termostatul să afișeze cu 0.5°C
sau 1.0°C mai mult (cât se presupune că ar fi la înălțimea optimă).
Pornire optimizată – este o funcție prin care termostatul se adaptează
treptat la mediul în care este instalat. Spre exemplu, când programele de
încălzire stabilite de dumneavoastră includ fluctuații mari de temperatură,
această funcție permite termostatului să pornească încălzirea în avans,
Apăsați “ACTUALIZARE Apăsați “Actualizare”. Dispozitivul este în curs de Dispozitivul a fost actualizat. Alegeți o valoare pentru Pentru a efectua modificările pentru a se asigura ca obtineti temperatura dorită în cel mai scurt timp de la
FIRMWARE”. actualizare. “Toleranță afișaj”. dorite, apăsați “SALVARE”. activarea unui program (interval) nou.
Model No: iT500
Internet Enabled Thermostat
iT500 Internet Enabled Programmable Thermostat with options for hot water control and two zone heating.

Features Technical Data


• Internet control via PC or Smartphone Thermostat iT500TX
• Local control
Supply 2 x AA Batteries
• Wall or surface mount thermostat
Scale 5-35 Deg C
• Touch controls on thermostat
• Frequency 868 MHz Gateway iTG500
• Heat/Cool Supply 5V (adaptor included)
• 2 x Volt Free Outputs Ethernet cable included
• Optional hot water control
Receiver iT500RX

Optional two zone heating with the Supply 230Vac 50Hz


addition of iT300* sensor Switch Rating 5 (3) A SPDT x 2
(sold separately)
Output 0 -230V

Sensor iT300 (Optional Extra)


Supply 2x AAA Batteries

Included in the box of the iT500

iT300 Sensor*

www.salus-tech.com 00077