MAIN FEATURES PROGRAMMABLE PARAMETERS

• Front push-bUtton panel made of polycarbonate • Two thresholdS


( antiscratch, oil and acid resistant ) • Time Reset
• Protection grade IP 65 • Inpuls multiplicatIon factor
• Acces to parameters with software key: Time • Count ( Up / Down )
Reset / Impuls Multiplier / Count / Decimal Point • Overcount
/ Restart / Autolearning / Count mode / Keys lock • Autolearning
/ Reset key function / Restart input / • Restart register
• Removable terminal connections
• Decimal point
• DIN 48 x 96 execution
• Reset key function
• Recessed assembly
• Keys lock
• Special retaining brackets
• Restart input

TECHNICAL FEATURES

• POWER SUPPLY : 24 - 110 - 220 Vac ( 50 / 60 Hz )


• SUPPLY TOLERANCE : + 10 % - 15 %
• ABSORPTION : 4 VA
• OPERATION TEMPERATURE : - 5 ł˚ C + 55 ˚ C
• CLIMATIC CONDITIONS : U.R. 95 % at 40 ˚ C ( without condensate )
• VISUALIZATION : 6 figures plus sign
• MULTIPLICATION FACTOR INPUT IMPULSES : from 0,00001 to 9,99999
• TYPE OF INPUTS : suitable for NPN bidirectional encoder ( PNP by request )
• COUNT FREQUENCY : up to 20 KHz
• IMPULS COUNT : on 4 fronts : x4 ( Standard )
: on 1 front : x1 ( by request )
• AUXILIARY INPUT SUPPLY : 12 Vdc - 100 mA available on terminal
• CONTROL INPUTS : reset counter - count restart - autolearning
• OUTPUTS : 2 relays - capacity of 5A - 250 Vac or 2 NPN transistors
35 Vdc - 100 mA
• RESET RELAY : manual or automatic with excitation time from 0,1 to 99,9
sec.
• PROGRAMMED DATA MEMORY : static ( without battery )

CET s.r.l. LBP62 PAGE 1


FRONT PUSH-BUTTON PANEL

D u r i n g p r o g r a m m i n g m o d e c u r s o r m o v e s t o t h e l e f t .
Y E L L O W
D u r i n g n o r m a l m o d e a l l o w s t e m p o r a r y v i s u a l i z a t i o n o f t h e p r o g r a m m e d d a t a

During programming mode increases the flashing figures.


Y E L L O W
During normal mode visualizes the previously set data on totalizer.

P R O G B L U E A c c e s s a n d q u i t f r o m t h e p r o g r a m m i n g m o d e .

E N T
D u r i n g p r o g r a m m i n g m o d e c o n f i r m s t h e d a t a a n d p a s s e s t o t h e n e x t ( E N T ) .
R E D
During normal mode resets the device ( RES ).
R E S

THRESHOLD PROGRAMMING
F O R T H R E S H O L D P R O G R A M M I N G A C C E S S P R O C E E D A S F O L L O W S :

P R E S S P U S H - B U T T O N P R O G T H E D I S P L A Y V I S U A L I Z E :

S 1 T H R E S H O L D S E T T I N G - P R O G R A M M A B L E F R O M 0 0 0 0 0 1 T O 9 9 9 9 9 9 .

- i f t h e d a t a s e t r e s u l t s t o b e = 0 t h e d e v i c e a c t s a s t o t a l i z e r , a u t o m a t i c a l l y

e x c l u d i n g t h e R e s e t T i m e a n d t h e O v e r c o u n t ( S U P )

- S 2 i s i n O F F S E T r e s p e c t S 1 ; i f S 1 i s e q u a l o r l o w e r t h a n S 2 , a u t o m a t i c a l l y

b e c o m e S 2 = S 1 - 1 .

P R O G E N T

Q U I T P R O G R A M M I N G

W I T H T H E K E Y S I N S E R T T H E N E W V A L U E S A N D C O N F I R M W I T HE N T

FUNCTIONING PARAMETERS PROGRAMMING

T H E P R O G R A M M A B L E P A R A M E T E R S A R E D I V I D E D I N T O T W O G R O U P S P R O T E C T E D B Y A 4 F I G U R E C O D E .

I N O R D E R T O O B T A I N A C C E S S T O P R O G R A M M I N G , P R O C E E D A S F O L L O W S :

P R E S S P U S H - B U T T O N P R O G F O R A B O U T 2 S E C S . T H E D I S P L A Y V I S U A L I Z E :

G R O U P 1 : E N T E R C O D E 2 3 5 7

E N T

S 2 T H R E S H O L D S E T T I N G - P R O G R A M M A B L E F O R M 0 0 0 1 T O 9 9 9 9

- i f t h e d a t a s e t r e s u l t s = 0 t h e S 2 t h r e s h o l d i s e x c l u d e d f r o m t h e w o r k i n g .

- i f t h e d a t a s e t r e s u l t s e q u a l o r h i g h e r t h a n S 1 , a u t o m a t i c a l l y b e c o m e S 2 = S 1 - 1

S 2 i s i n O F F S E T r e s p e c t S 1 , t h a t i s t h e r e a l S 2 = S 1 - S 2 . F o r e x a m p l e : S 1 = 1 0 0

S 2 = 2 0 . T h e r e a l v a l u e o f S 2 i s = 1 0 0 - 2 0 = 8 0

E N T

A U T O M A T I C T I M E R E S E T S E T T I N G - P R O G R A M M A B L E F R O M 0 , 1 T O 9 9 , 9 s e c .

- i f p r o g r a m m e d = 0 t h e R E S E T i s M A N U A L

- i f p r o g r a m m e d w i t h a v a l u e , t h e R E S E T i s A U T O M A T I C a n d t h e O V E R C O U N T

( S U P ) i s a u t o m a t i c a l l y e x c l u d e d .

E N T

M U L T I P L I E R O F T H E I M P U L S E S i s p r o g r a m m a b l e f r o m 0 , 0 0 0 0 1 t o 9 , 9 9 9 9 9

- i f p r o g r a m m e d = 0 i t a u t o m a t i c a l l y r e p r o g r a m m e s = 1 . I f a c o u n t v a l u e i s t o b e

d i v i d e d , s e t a n u m b e r l o w e r t h a n 1 o n t h e m u l t i p l i e r . F o r e x a m p l e , t o d i v i d e d b y 5
E N T
s e t 0 , 2 ( 1 : 5 = 0 , 2 ) ; t o d i v i d e d b y 8 s e t 0 , 1 2 5 ( 1 : 8 = 0 , 1 2 5 )

C O U N T P R O G R A M M I N G :

- U P = U P : t h e c o u n t i n c r e a s e s ( f r o m 0 t o S 1 )

- d n . = D O W N : c o u n t d e c r e a s e s ( f r o m S 1 t o 0 )

P R O G E N T

Q U I T P R O G R A M M I N G

P R E S S P U S H - B U T T O N R E S O U T S I D E P R O G R A M M I N G F O R N E W V A L U E E N T E R I N G A C C E S S

PAGE 2 LBP62 CET s.r.l.


FUNCTIONING PARAMETERS PROGRAMMING

P R E S S P U S H - B U T T O N P R O G . F O R A B O U T 2 S E C S . T H E D I S P L A Y V I S U A L I Z E S :

G R O U P 2 : E N T E R C O D E 2 4 1 3

E N T

O V E R C O U N T P R O G R A M M I N G : i n t h i s w o r k i n g m o d e w h e n t h e c o u n t

p a s s t h e S 1 v a l u e s e t o n t h e O U T P U T 1 a n d p r o c e e d o n t h e v i s u a l i z a t i o : n

i f t h e c o u n t r e t u r n u n d e r S 1 o r S 2 t h e O U T P U T S t u r n o f f .

i f i t i s o n i t a u t o m a t i c a l l y e x c l u e d t h e T i m e r e s e t

- Y . = O V E R C O U N T o n

- n . = O V E R C O U N T o f f

E N T

A U T O L E A R N I N G : i f i t i s Y . y e s , t h e t w o l e d s o n t h e f r o n t b l i n k i n g a n d w h e n

t h e i n p u t c o m m a n d i s c l o s e t h e d e v i c e m e m o r i z e a s S 1 t h e v a l u e o n t h e

d i s p l a y . I t c a n n o t m e m o r i z e n e g a t i v e v a l u e s .

- Y . = A U T O L E A R N I N G a c t i v e

- n . = A U T O L E A R N I N G e x c l u d e d

E N T

R E S T A R T R E G I S T E R : v a l u e p r o g r a m m a b l e f r o m 0 t o 9 9 9 9 9 9

I t c a n b e i n s e r t e d w i t h t h e f r o n t a l R E S k e y ( i f p r o g r a m m e d ) o r w i t h t h e

b a c k c o m m a n d i n i m p u l s i v e o r d i r e c t m o d e )

E N T

I t i s p o s s i b l e t o p r o g r a m m a D E C I M A L P O I N T o n t h e l a s t t h r e e d i g i t s

- 1 -> 999999 - 2 -> 99999.9

- 3 -> 9999.99 - 4 -> 999.999

E N T

I t ’ s p o s s i b l e t o s e l e c t t h e w o r k i n g m o d e o f t h e f r o n t a l E N T / R E S k e y :

- 1 - I N H I B I T R E S E T . I t i s p o s s i b l e t o r e s e t t h e d e v i c e o n l y f r o m t h e i n p u t

c o m m a n d

- 2 - A C T I V E R E S E T . I t i s p o s s i b l e t o r e s e t t h e d e v i c e f r o m t h e f r o n t k e y

a n d f r o m t h e i n p u t c o m m a n d

- 3 - I M P U L S I V E R E S T A R T t h e k e y w o r k i n g a s i m p u l s i v e R e s t a r t

E N T

K E Y L O C K : i n h i b i t t h e p o s s i b i l i t y t o m o d i f y t h e S 1 w i t h t h e k e y

- Y : L O C K a c c e s s t o S 1

- n : F R E E a c c e s s t o S 1

E N T

S e l e c t i o n o f t h e R E S T A R T I N P U T M O D E :

- I . I N P U L S I V E R E S T A R T ; i l R E S T A R T

- C . C O N T I N U O U S R E S T A R T ; w h e n t h e i n p u t c o m m a n d i s c l o s e t h e

d i s p l a y s h o w s t h e R e s t a r t v a l u e u p t o t h e i n p u t c o m m a n d i s o n

P R O G E N T

Q U I T P R O G R A M M I N G

P R E S S P U S H - B U T T O N R E S O U T S I D E P R O G R A M M I N G F O R N E W V A L U E E N T E R I N G A C C E S S

CET s.r.l. LBP62 PAGE 3


WORKING DIAGRAMS
WORKING IN MANUAL

O U T P U T 1 In MANUAL working the OUTPUT 1 is on


when the count is equal or higher than S1
O U T P U T 2 and it’s stay on up to a RESET command.
The OUTPUT 2 is on when the count is
R E S E T higher or equal than S2 and it’s stay on up
to a RESET command.
S 1
S 2

C O U N T

AUTOMATIC RESET WORKING

O U T P U T 1
The AUTOMATIC RESET working is the
same of the MANUAL one but when the S1
O U T P U T 2
value is over, the count and the OUTPUT2
are automatically resetted and the
R E S E T OUTPUT 1 is on all time long setted in " t.r."
The count restart the same working.
S 1
S 2

C O U N T

t.r. t.r. t.r.

OVERCOUNT WORKING

O U T P U T 1 In OVERCOUNT ( SUP.) working the


OUTPUTS 1 - 2 are on every time the
O U T P U T 2 count is equal or higher than the S1 and
S2 values. The S1 and S2 OUTPUTS are
R E S E T off every time the count is lower than S1
and S2 values. With a RESET command
the OUTPUTS turn off and the count
S 1
restart the same working.
S 2

C O U N T

In DOWN programmation the S1 programmed In the AUTOMATIC RESET working the "t.r." time
value is the count Start value and the OUTPUT 1 is reset must be lower than the time used from the
on when the count is = 0; the OUTPUT 2 is on count to arrive at the S1 value. Otherwise the
when the count is equal or lower than S2. OUTPUTS 1 - 2 wil be alwayas on.

The RESTART Register value is between 0 and If the learned threshold value with
999999. Every time the RESTART input is close the AUTOLEARNED ( APP ) input is lower than the
RESTART value is loaded on display visualization current count, the OUTPUTS go on. In the
contrary way, if the OUTPUTS are already on,
they turn off.

PAGE 4 LBP62 CET s.r.l.


COUNT DIAGRAMS
UP COUNTING

P H A S E 1

x 4

P H A S E 2

P H A S E 1

x 1

P H A S E 2

DOWN COUNTING

P H A S E 1

x 4

P H A S E 2

P H A S E 1

x 1

P H A S E 2

WIRING CONNECTIONS OUTPUT CHARACTERISTICS

O U T P U T 1 O U T P U T 2
RELAY :

LBP62S The RL1 - RL2 outputs have 5A -


TRANSISTOR OUTPUTS 250 VAC contacts
O O
G G
U U
N N
T T

2
D
1
D
STATIC :

1 9 1 8 1 7 1 6 1 5 1 4 The OUT 1 and OUT 2 outputs are


NPN in direct voltage with GND in
common together.
1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 The maximun voltage applied to its
outputs is 35 Vdc and its maximum
current is 100mA.

1 2 V d c
1 0 0 m A
0 2 4 1 1 0 2 2 0 C N T 1
R e s e t C N T 2

A C P O W E R R e s t a r t
A u t o l e a r n i n g

CET s.r.l. LBP62 PAGE 5


WIRING CONNECTIONS INPUT SIGNALS

O U T P U T 1 O U T P U T 2
LBP62
RELAY OUTPUTS R L 2 R L 1

1 9 1 8 1 7 1 6 1 5 1 4
C N T 1 C N T 2

6 1 1 1 2 7
1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3

N P N / P N P B I D I R E C T I O N A L E N C O D E R 1 2 V d c

P N P B Y R E Q U E S T

1 2 V d c
1 0 0 m A

0 2 4 1 1 0 2 2 0 C N T 1
R e s e t C N T 2

A C P O W E R R e s t a r t
A u t o l e a r n i n g

OVERALL DIMENSIONS ( mm )

F R O N T S I D E 1 0 M a x .

R E T A I N I N G
R E M O V A B L E

B R A C K E T S
T E R M I N A L
9 2
4 8

L 1 L 2
E N T
4 4

P R O G
R E S

e l e c t r o n i c c o u n t e r L B P

9 6 1 9 1 3 0 9

1 5 8

B A C K D R I L L T E M P L A T E

19 18 17 16 15 14
4 8

4 5

1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3

9 6

9 3

CET Control System S.a.s. Agent :


SS 211 Km 53,550
28071 Borgolavezzaro - No - ITALY
Tel : ++39 321-885180/885301/885807
Fax : ++39 321-885560

PAGE 6 LBP62 CET s.r.l.

You might also like