Professional Documents
Culture Documents
L= 24 in L= 24 in
B= 18 in B= 24 in
n= 6.3 ft
DEPTH CHECK
Let
Depth, d= 18 in (5% of Total UNF column load)
For OK
Design Shear >Developed Beam Shear
Hence∅Vc1> Vu1
Then OK
STEEL CALCULATION
12 mm 28 12 mm 0.2 in2
16mm 18 16mm 0.31 in2
19 mm 13 19 mm 0.44 in2
20 mm 12 20 mm 0.49 in2
22 mm 9 22 mm 0.6 in2
25 mm 8 25 mm 0.75 in2
28 mm 6 28 mm 1 in2
32 mm 4 32 mm 1.27 in2
35 mm 4 35 mm 1.56 in2
38 mm 3 38 mm 1.77 in2
44 mm 2 44 mm 2.4 in2
Minimum Reinforcement
ρs(min)= 0.0033333333
Ld=
Net upward load per linear foot of the transverse beam, Qu= 41 k/ft
The moment at the edge of the Interior Beam, Mu= 317 k-ft
3799 k-in
PUNCHING SHEAR
STEEL CALCULATION
10 mm 20 10 mm 0.11 in2
12 mm 11 12 mm 0.2 in2
16mm 7 16mm 0.31 in2
19 mm 5 19 mm 0.44 in2
20 mm 4 20 mm 0.49 in2
22 mm 4 22 mm 0.6 in2
25 mm 3 25 mm 0.75 in2
28 mm 2 28 mm 1 in2
32 mm 2 32 mm 1.27 in2
35 mm 1 35 mm 1.56 in2
38 mm 1 38 mm 1.77 in2
44 mm 1 44 mm 2.4 in2
Minimum Reinforcement
ρs(min)= 0.0033333333
m= 0.833333 ft
30 2.5
Trans bar= 22 mm
Trans bar dia= 0.87 in
L= 47 in
3.916666667 ft
Longitudinal, d= 18 in
Transverse, d= 17.0 in
So, use 22mm bar
C= 155 kip
D= 201 kip
E= 121 kip
x= 3.6 ft
b=
L=
C=
T=
d=
∅=
λ=
f'c=
dreq= 2.7 in
dreq= 2.72 in
dpro= 20 in
OK
16 mm
0.63 in
0.94 in
1.2 ksf
10 ft
10 ft
18 in 1.5 ft
24 in
20 in 1.67 ft
0.75
1
4000 psi