You are on page 1of 12

DAILY PAINTING INSPECTION REPORT

COMPANY QATARGAS DATE : 1/28/2019


LTC-C-MNT-1650-14
CONTRACTOR DPIS REPORT NO: XE/PNT/QG3/00
SUBCONTRACTOR ˗ QG CONTRACT REF NO. RFI No: N/A

QG WO NO. 10999756 QG SAP NO. ….. Location Ref: QG3 UTILITY

Description
Abrading,Washing and Application of Finalcoat for Internal side which includes Shell,Top/Bottom Dish and Manway cover of Wet Air Receiver Vessel for 5
V9501A .

Wash Degreasing ABRASIVE BLAST CLEAN Blast Profile HAND TOOL POWER TOO
Surface Preparation
Yes N/A N/A N/A N/A N/A

Abrasive: N/A
Air Quality for Undercoat water
Yes Salt level N/A Yes
Blasting/Painting washing
Batch: N/A
PAINT SYSTEM Primer Mid Coat Top Coat
1 Midcoat
st
2 Midcoat
nd

IM-03 WFT WFT WFT N/A WFT 220-250 µm


DFT DFT DFT N/A DFT 452-458 µm

Paint Hempadur 85671

Batch:829010816
Hempel Paints Comp A
Best Before:01-2020

Paint Curing Agent 97371

Batch:078055745
Hempel Paints Comp B
Best Before:05-2019

QUALITY TESTS AS PER QG Dust level Grade Stripe Coats Inter-coat Interval
ITP Yes Maintained
DFT Readings in µm Adhesion test Coating Defects
Visual
N/A
455 452 456 458 455 457 456 456 No
INSP’n RESULTS PAINTING REPAIRS PAINTING WORK REJECTED PAINTING WORK ACCEPTED Yes

Web Bulb ˚C Dry ˚C


Bulb Dew Point Relative Steel Temp.
Time Inspector Comments Profile Tape
˚C Humidity % ˚C

8:30 AM 19 25 16 62 27

10:30 AM 21 28 19 59 29

2:00 PM 18 27.9 15 50 31

3:30 PM 26.5 31.5 25 69 32

PAINT INSP’N REPORT PAINTING INSPECTED & PREPARED BY PAINTING CONTRACTOR INSPECTED & REVIEWED BY QATAR GAS
CONTRACTOR
POSITION PAINTING INSPECTOR PAINTING INSPECTOR
SIGNATURE

NAME Ritesh D.N


DATE
1/28/2019
XE/PNT/QG3/003
N/A

QG3 UTILITY

h includes Shell,Top/Bottom Dish and Manway cover of Wet Air Receiver Vessel for 59-

POWER TOOL

N/A

TOTAL
Avg. DFT in µm

456 µm

Inter-coat Interval
Maintained
Coating Defects

No
Yes

Profile Tape

INSPECTED & REVIEWED BY QATAR GAS

PAINTING INSPECTOR
DAILY PAINTING INSPECTION REPORT

COMPANY QATARGAS DATE : 1/27/2019


LTC-C-MNT-1650-14
CONTRACTOR DPIS REPORT NO: XE/PNT/QG3/00
SUBCONTRACTOR ˗ QG CONTRACT REF NO. RFI No: N/A

QG WO NO. 10999756 QG SAP NO. ….. Location Ref: QG3 UTILITY

Description
Abrading,Washing and Application of 1st Midcoat for Internal side which includes Shell,Top/Bottom Dish and Manway cover of Wet Air Receiver Vessel fo
V9501A .

Wash Degreasing ABRASIVE BLAST CLEAN Blast Profile HAND TOOL POWER TOO
Surface Preparation
Yes N/A N/A N/A N/A N/A

Abrasive: N/A
Air Quality for Undercoat water
Yes Salt level N/A Yes
Blasting/Painting washing
Batch: N/A
PAINT SYSTEM Primer Mid Coat Top Coat
1 Midcoat
st
2 Midcoat
nd

IM-03 WFT WFT 220-250 µm WFT N/A WFT N/A


DFT DFT 313-322 µm DFT N/A DFT N/A

Paint Hempadur 85671

Batch:829010816
Hempel Paints Comp A
Best Before:01-2020

Paint Curing Agent 97371

Batch:078055745
Hempel Paints Comp B
Best Before:05-2019

QUALITY TESTS AS PER QG Dust level Grade Stripe Coats Inter-coat Interval
ITP Yes Maintained
DFT Readings in µm Adhesion test Coating Defects
Visual
N/A
315 313 320 322 318 320 315 318 No
INSP’n RESULTS PAINTING REPAIRS PAINTING WORK REJECTED PAINTING WORK ACCEPTED Yes

Web Bulb ˚C Dry ˚C


Bulb Dew Point Relative Steel Temp.
Time Inspector Comments Profile Tape
˚C Humidity % ˚C

8:30 AM 18.9 26 16 53 28

10:30 AM 20.1 27 19 61 30

2:00 PM 21 28.3 18 54 31.4

3:30 PM 22 30.3 19 55 30.8

PAINT INSP’N REPORT PAINTING INSPECTED & PREPARED BY PAINTING CONTRACTOR INSPECTED & REVIEWED BY QATAR GAS
CONTRACTOR
POSITION PAINTING INSPECTOR PAINTING INSPECTOR
SIGNATURE

NAME Ritesh D.N


DATE
1/27/2019
XE/PNT/QG3/002
N/A

QG3 UTILITY

hich includes Shell,Top/Bottom Dish and Manway cover of Wet Air Receiver Vessel for 59-

POWER TOOL

N/A

TOTAL
Avg. DFT in µm

318 µm

Inter-coat Interval
Maintained
Coating Defects

No
Yes

Profile Tape

INSPECTED & REVIEWED BY QATAR GAS

PAINTING INSPECTOR
DAILY PAINTING INSPECTION REPORT

COMPANY QATARGAS DATE : 1/26/2019


LTC-C-MNT-1650-14
CONTRACTOR DPIS REPORT NO: XE/PNT/QG3/00
SUBCONTRACTOR ˗ QG CONTRACT REF NO. RFI No: N/A

QG WO NO. 10999756 QG SAP NO. ….. Location Ref: QG3 UTILITY

Description
Degreasing,High pressure washing,Blasting and Priming of Internal side which includes Shell,Top/Bottom Dish and Manway cover of Wet Air Receiver Ves
59-V9501A .

Wash Degreasing ABRASIVE BLAST CLEAN Blast Profile HAND TOOL POWER TOO
Surface Preparation
Yes Yes Sa2.5 77 µm N/A N/A

Abrasive: Garnet 30-60


Air Quality for Undercoat water
Yes Salt level 2.5µg/cm² N/A
Blasting/Painting washing
Batch: VA#101/18
PAINT SYSTEM Primer Mid Coat Top Coat
1 Midcoat
st
2 Midcoat
nd

IM-03 WFT 220-250 µm WFT N/A WFT N/A WFT N/A


DFT 150-154 µm DFT N/A DFT N/A DFT N/A

Paint Hempadur 85671

Batch:829010816
Hempel Paints Comp A
Best Before:01-2020

Paint Curing Agent 97371

Batch:078055745
Hempel Paints Comp B
Best Before:05-2019

QUALITY TESTS AS PER QG Dust level Grade Stripe Coats Inter-coat Interval
ITP Yes N/A
2
DFT Readings in µm Adhesion test Coating Defects
Visual
N/A
152 150 151 153 154 150 153 152 No
INSP’n RESULTS PAINTING REPAIRS PAINTING WORK REJECTED PAINTING WORK ACCEPTED Yes

Web Bulb ˚C Dry ˚C


Bulb Dew Point Relative Steel Temp.
Time Inspector Comments Profile Tape
˚C Humidity % ˚C

8:30 AM 17.5 25 15 53 25

10:30 AM 19 27 16 55 26

2:00 PM 20 29 16 48 30.1

3:30 PM 20.5 31 18 46.9 32

PAINT INSP’N REPORT PAINTING INSPECTED & PREPARED BY PAINTING CONTRACTOR INSPECTED & REVIEWED BY QATAR GAS
CONTRACTOR
POSITION PAINTING INSPECTOR PAINTING INSPECTOR
SIGNATURE

NAME Ritesh D.N


DATE
1/26/2019
XE/PNT/QG3/001
N/A

QG3 UTILITY

de which includes Shell,Top/Bottom Dish and Manway cover of Wet Air Receiver Vessel for

POWER TOOL

N/A

TOTAL
Avg. DFT in µm

152 µm

Inter-coat Interval
N/A
Coating Defects

No
Yes

Profile Tape

INSPECTED & REVIEWED BY QATAR GAS

PAINTING INSPECTOR

You might also like