mRC-C-450-100/240 – mini Recirculating Chiller

compact water cooling system

450 W cooling capacity


(T WATER +25°C, T AMBIENT +25°C)
high cooling capacity in compact format
90 to 264 VAC universal power supply
temperature stability down to ±0.05 K
flow rate 1 to 5.5 lpm @1.5 to 0.5 bar
low vibration
automatic fill & drain
IoT enabled

THERMAL
MANAGEMENT
mRC-C-450-100/240
circuit breaker main dimensions [mm]

liquid coolant in filter


liquid coolant out

The mRC-C-450-100/240 mini recirculating chiller features a vapor key features


compression circuit and a closed, pressurized recirculating water circuit.  recirculating water chiller
On the refrigeration side, a miniature rotary compressor as well as  ideal for water cooling tasks up to 450 W
customized condensers and evaporators are utilized to reduce the size.  compact size, easy to be integrated in customer application
 90 to 264 VAC, 24 VDC derivative available
The compressor’s BLDC motor is speed controlled by an inverter,  PID parameters and fan speed adjustable
eliminating annoying switching noise of hot gas bypass known from ON/  smooth, low-noise operation
OFF compressors. Throughout its speed range, the compressor twin pump  valved and non-valved water connections available
design offers low vibration and low noise. Compact centrifugal pumps on
the water circuit side also contribute to the compact size. specifications
power supply 90 to 264 VAC
Since the water circuit is pressurized, the mRC-C-450-100/240 manages power consumption < 300 W
cooling capacity 300 W (TWATER = +20°C, TAMBIENT = +40°C)
with a very small tank – without the risk of cavitation in the smoothly to 500 W (TWATER = +20°C, TAMBIENT = +20°C)
operating centrifugal pump. Overpressure on the cooling system also ambient temperature range +10°C to +45°C
prevents the ingress of bacteria and oxygen and thus extends the set coolant temperature range +10°C to +30°C
maintenance intervals. temperature stability ±0.05 K continuous operation,
+2/-1.5 K over-/undershoot @250 W heat load ON/OFF
available pressure head 1.5 bar @1 lpm, 0.5 bar @5.5 lpm
The mRC-C-450-100/240 features full chiller power and up to 450 W cabinet bench-top
cooling capacity in a shoe box form factor. Its universal 90 to 264 VAC weight 13 kg
power supply allows it to be plugged in anywhere in the world. dimensions 350 mm × 280 mm × 230 mm, main body without filter
noise level 63 dBA (fan 40%, compressor 100%)
control local, USB/serial, internet (web browser) via Ethernet
interlock I/O alarms liquid level, tank pressure, coolant feed temperature,
coolant flow rate, condenser pressure
approval CE

mRC-C-450-100/240 – process & instrumentation diagram


Animated
process diagram
cooling performance / pressure head

mRC-C-450-100/240 cooling capacity mRC-C-450-100/240 pressure head vs. flow


(compressor 100 rps, fan 100%)

cooling capacity [W]

pressure head [bar]


coolant temperature [°C] flow [lpm]

Tamb: +20°C Tamb: +30°C Tamb: +40°C no filter + filter L=100, 20 µm + filter L=55, 20 µm

automatic fill & drain


Using automatic air and water pump technology integrated into the unit,
the cooling water in the tank and pipe system of the mRC-C-450-100/240
can be automatically filled and drained at the push of a button – without
the need for time-consuming tilting or removing the unit or the tank
from the system and avoiding annoying spills or leaks.

IoT ready

An integrated Ethernet interface allows access to system parameters of the mRC-C-450-100/240 as well as remote control of the cooling system via a web browser

 remote operation: • other: system internal temperature, time & date


• switch on/off • all data can be kept on memory card or/and in real-time database
• set regulation temperature
 remote service:
• set fan speed
• switch on/off components individually: compressor, heaters, fan,
 remote monitoring: pump, coolant and pressure valves
• water loop: temperature setpoint, inlet temperature, outlet tem- • setting of alarms thresholds
perature, cooling water flow, pressure, cooling water level in tank • setting of filling and draining timeout
• coolant loop: compressor speed setpoint, condenser temperature, • clear alarms
heater power, fan speed • PID settings
• current and voltage: supply voltage, control board current, com- • filling and draining procedure (not recommended, remote hands
pressor current, heater current, pump current, fan current, valves needed)
current • power-on-test on/off
• alarms: liquid level low, cooling loop over-pressure, outlet tem-
 remote update of firmware
perature out of range, flow out of range, supply voltage out
of range
enabling your ideas.
Optical, Power and Thermal Management Technologies

GERMANY ITALY SPAIN


AMS Technologies AG AMS Technologies S.r.l. AMS Technologies S.L.
Fraunhoferstr. 22 Via Copernico, 21 C/Filadors 35, 3o, 7a
82152 Martinsried, Germany 20025 Legnano (MI), Italy 08208 Sabadell, Spain

Copyright 2022 by AMS Technologies Rev. mRC-C-450-100/240_-_mini_Recirculating_Chiller _63-22-01


Phone + 49 (0) 89 895 77 0 Phone + 39 0331 596 693 Phone + 34 93 380 84 20

FRANCE NORDICS UNITED KINGDOM


AMS Technologies S.A.R.L. AMS Technologies Nordics AMS Technologies Ltd.
Silic 649 – Bâtiment Magnolia Azpect Photonics AB Nene House, Drayton Way
16, avenue du Québec Aminogatan 34 Daventry, Northamptonshire
91945 Courtaboeuf Cedex 431 53 Mölndal, Sweden NN11 8EA, United Kingdom
Phone + 33 (0) 1 64 86 46 00 Phone + 46 (0) 8 55 44 24 80 Phone + 44 (0)1455 556360

Download Brochure

info@amstechnologies.com
www.amstechnologies.com
www.amstechnologies-webshop.com

You might also like