Professional Documents
Culture Documents
50 mm
24 mm
24x19 Eurocone
Topway Compact, distribution manifold with lockshields/flow meters incorporated ...................................................................... 8
50 mm
24 mm
Topway, single bar distribution manifold ..................................................................................................................................................................... 10
24x19
Customised comfort
Thanks to the Topway System, houses can be subdivided into various
unlimited areas, by simply applying thermoelectric heads for valves
monitoring purposes.
The plumber is thus able to regulate the temperature in every room
in a rational fashion, without architectural hindrances and without
requiring further operations, as the outlet box is the only tool involved.
In other words, the Topway header is the first, truly effective control-
ler of the whole heating system.
4
Topway
100%
Pre-assembled bar manifold nickel-plated Tested
Construction
All Topway manifold distribution heads are nickel/brass plated.
Brass header 24 mm through a bar
retrieved 26drawing
mm process UNI EN
12168 CW614N. Seals in EPDM 70. 3/4”
Topway pre-assembled manifold is supplied together with:
• Lockshields with
24x19flow meters included on inlet ( (0÷4 ℓ/min or
Eurocone
0÷2,5 ℓ/min).
• Manual adjustment valves set up to take thermo-electric
heads.
• n° 2 blanking plugs 1” or 1”1/4 complete with O-Ring.
• n° 2 water drain valves 1/2” with plugs.
• n° 2 Tecno-Varia air vent 1/2” with bleed (lateral + manual).
• n° 2 double metal holders 1” or 1”1/4.
Note: n° 2 1” or 1”1/4 Progress ball valves with red and blue but-
terfly handles, with or without thermometer holder and ther-
mometer, are supplied optionally.
5
How to install your pre-assembled Topway
A 2 3 4 5
Outlet
Inlet
7
8
6
Topway pre-assembled distribution manifold with lockshields with flow meters included
B
F L A
G1 o G1¼
200
E
G½
C
50 24x19 D
G ¾ Eurocone
1” 1”1/4
A mm 26,5 30,5
B mm 51 58,5
C mm 56,5 60,5
D mm 81 89,5
E mm 361,5 371,5
F mm 97 135
Model 2 ways 3 ways 4 ways 5 ways 6 ways 7 ways 8 ways 9 ways 10 ways 11 ways 12 ways
1” L mm 174 224 274 324 374 424 474 524 574 624 674
1”1/4 L mm - - 282 332 382 432 482 532 582 632 682
7
Topway Compact
100%
distribution manifold Tested
50 mm
24 mm
Technical data
Maximum operating temperature: 110 °C with lockshields;
90 °C with flow meters
24x19 Maximum operating pressure: 10 bar with lockshields;
6 bar with flow meters
Head thread: G 1”
Side ways thread: 24x19 - 3/4” Eurocone
Note: 24x19 thread: 24 mm diameter gas thread and 19 screw
threads per inch.
Note: seal on thread of heads ONLY with o-ring.
DO NOT USE taperad threads.
8
Topway Compact distribution manifold kit with lockshields with flow meters included,
adjustable supports
B
F L A POSITION A-A POSITION B-B
1” 1”
A mm 39 39
G1
B mm 66 66
C mm 69 65
D mm 96 92
G
E mm 320 320
E
F mm 97 97
G½
G mm 200 210
50 C
24x19 D
Model 2 ways 3 ways 4 ways 5 ways 6 ways 7 ways 8 ways 9 ways 10 ways 11 ways 12 ways
1” L mm 165,5 215,5 265,5 315,5 365,5 415,5 465,5 515,5 565,5 615,5 665,5
Note: Pressure drops and values see the following pages
Topway Compact with bibcocks and lockshields with or without flow meters included,
adjustable supports
B
F L
A POSITION A-A POSITION B-B
A mm 39 39
B mm 66 66
G1
C mm 69 65
D mm 96 92
E mm 320 320
G E F mm 97 97
G mm 200 210
G½
50 M 24x19
C
D
G ¾ Eurocone
Model 2 ways 3 ways 4 ways 5 ways 6 ways 7 ways 8 ways 9 ways 10 ways 11 ways 12 ways
1” L mm 114 164 214 264 314 364 414 464 514 564 614
9
Topway
100%
single bar distribution manifold Tested
50 mm
50 mm
50 mm
10
Topway return manifold nickel-plated with valves
L
Ø38
2 3 4 5 6 7 8 9 10 11 12
Model
27
ways ways ways ways ways ways ways ays ays ways ways G 1/2
1” L mm 164 214 264 314 364 414 464 514 564 614 664
1”1/4 L mm 170 220 270 320 370 420 470 520 570 620 670
1/2”F
Note: threads takeoff 50 mm
50 mm 24x19
G 3/4 Eurocone
2 3 4 5 6 7 8 9 10 11 12
Model G 1/2
ways ways ways ways ways ways ways ways ways ways ways
1” L mm 164 214 264 314 364 414 464 514 564 614 664
20 mm
1”1/4 L mm 170 220 270 320 370 420 470 520 570 620 670
G 1/2
Note: threads takeoff 50 mm 50 mm 24x19
G 3/4 Eurocone
30 mm
75 MAX
2 3 4 5 6 7 8 9 10 11 12
Model ways ways ways ways ways ways ways ways ways ways ways G 1/2
1” L mm 164 214 264 314 364 414 464 514 564 614 664
1”1/4 L mm 170 220 270 320 370 420 470 520 570 620 670
20 mm
G 1/2
Note: threads takeoff 50 mm
50 mm 24x19
G 3/4 Eurocone
2 3 4 5 6 7 8 9 10 11 12 G 1/2
Model
ways ways ways ways ways ways ways ways ways ways ways
3/4” L mm 85 121 157 193 229 265 301 337 373 409 445
Note: threads takeoff 36 mm
24x19
3/4” L mm 103 153 203 253 303 353 403 453 503 553 603 G 3/4 Eurocone
36-50 mm mod. 3/4”
1” L mm 114 164 214 264 314 364 414 464 514 564 614
50 mm mod. 1” and 1”1/4
1”1/4 L mm – – 220 270 320 370 420 470 520 570 620
Note: threads takeoff 50 mm
11
Topway R
distribution manifold for radiators
1” 1”1/4
A mm 26,5 30,5
B mm 51 58,5
C mm 56,5 60,5
D mm 81 89,5
200
E
E mm 323 364
F mm 97 135
C
50 24x19
D
Model 2 ways 3 ways 4 ways 5 ways 6 ways 7 ways 8 ways 9 ways 10 ways 11 ways 12 ways
1” L mm 124 174 224 274 324 374 424 474 524 574 624
1”1/4 L mm - - 232 282 332 382 432 482 532 582 632
12
Manual valve (suitable for electrothermic heads)
Pressure drops valve with manual handwheel Valve with manual handwheel: Kv values
1000 2,50
0,5 Kv=1,24
1 Kv=1,80 2,00
1,5 Kv=2,05
1,50
2 Kv=2,20
Kv
TA Kv=2,40
100 0,50
0,00
0 0,5 1 1,5 2 2,5 3
10
10 100 1000
Q [l/h]
TA = All open.
The above values refer to water temperature at 15 °C.
∆p = ∆p supply + ∆p return
13
Transformable double regolating lockshield
2 1
Fig. B
Fig. A
Lockshield adjustment (Fig. A) Replacement of the regulator with a flow meter cartridg (Fig. B)
The lockshield is delivered in a partially OPEN position, to carry The Emmeti transformable lockshield allows you to add a flow
out the calibration: meter:
1 - Remove the cap 1; - on an operating system;
2 - Turn the cap 1 over, and, using the impression inside it, - with no water leakage;
manually turn the lockshield 2 anticlockwise until you feel - con una operazione semplice e rapida.
resistance; 1 - Close the lockshield using the cap A;
3 - With an allen key ch 4, screw completely, until it stops the 2 - Remove the regulator B g an Allen key and a screwdriver;
regulator 3; 3 - Insert the measuring cartridge C the ring nut D.
The lockshield is now ready for flow setting: 4 - Manually rotate the ring nut D counterclockwise until you
4 - Unscrew the regulator 3 anti-clockwise, by the desired feel resistance.
number of turns (see diagram); 5 -Calibrate the measuring cartridge C until the desired flow
5 - Insert the cap again. rate is reached (directly shown on the flow meter).
It is also possible to seal the cap in the position reached by using
6 -Raise the ring nut D l it clicks, indicating that it is in the correct
lead, exploiting the holes in the fins 4 to secure it directly to the position: it is now possible to close and open the circuit with-
manifold, thereby preventing any tampering. out chan-ging the calibration.
100 100
0 Kv = 0,05
0 Kv= 0,05
0,5 K v =0,10
1 Kv = 0,26
0,5 Kv= 0,10
1,5 Kv=0,46 1 Kv= 0,26
2 Kv =0,75 1,5 kv=0,45
2,5 Kv=1,08 2 Kv =0,72
T.A. Kv= 1,2 2,5 Kv=0,98
10 T.A. Kv =1,07
10 100 1000 10
10 100 1000
Q [ℓ/h]
Q [ℓ/h]
TA = All open. The above values refer to water temperature at TA = All open. The above values refer to water temperature at
15 °C. 15 °C.
= No. of turns for opening adjustment device C ∆p = ∆p supply + ∆p return
= No. of turns for opening adjustment device C
14
Lockshield: Kv values Kv values at different lockshield openings,
with totally open valve
1,2
1,2
1 1
0,8 0,8
0,6
Kv
0,6
Kv
0,4 0,4
0,2 0,2
0 0
0 0,5 1 1,5 2 2,5 0 0,5 1 1,5 2 2,5
No. of turns for opening of lockshield adjustment screw No. of turns for opening of lockshield adjustment screw
Example of calculation:
Calculation of the pressure loss ∆p with a water flow rate Q of 200 ℓ/h determined by valve and lockshield with opening of 2.5
turns of the controller 3 .
1° method: use of pressure drop diagram Q = 200 ℓ/h ∆p = 40 mbar
the Kv represents the flow Q in m3/h at an ∆p equal to 1 bar: Kv = Q /√∆p
la relation that connects the ∆p (bar) to the flow Q (m3/h) is the following: ∆p = Q2 / Kv2
2° method: use of Kv diagram Kv = 0,98 Q = 0,2 m3/h
∆p = 0,2 2 / 0,982 = 0,04 bar
15
Lockshields with flow meters included
4
2
1
3 4
2 2
1 3
1
Flow regulation and interception device with set calibration Flow rate adjustment
memory and regulated flow display system. Simple, direct ca-
libration by means of indicator that displays the circuit flow. (do not use tools)
The special design also makes it possible to clean the window Flow meter is delivered in a partially OPEN position, to carry
or replace the entire measurement component with the mani- out the calibration:
fold under pressure. Step 1 manually rotate the ring nut 1 counterclockwise until
you feel resistance.
Technical data Step 2 calibrate using the adjuster 2 until the desired flow
Measurement field: 0 ÷ 4 ℓ/min or 0 ÷ 2,5 ℓ/min rate is reached (directly shown on the flow meter).
Indication error: ± 10% full-scale Step 3 raise the ring nut 1 until it clicks, indicating that it is in
Maximum operating pressure: 6 bar the correct positio: it is now possible to close and open
Maximum operating temperature: 90 °C the circuit without changing the calibration.
Pressure drops: Kv from 0,15 (1 ℓ/min) to 0,55 (4 ℓ/min)
Maximum pressure drop (off scale): Kv=9 Note: all the above operations must be performed manually.
Pressure test (25 °C max): 10 bar
It is also possible to seal the ring nut in the position reached
using a lead seal and the holes in the fins 3 to ensure it:
– directly to the manifold, preventing any tampering;
– to the flow meter, making it possible to close the flow with-
out modifying the set maximum opening calibration.
16
Pressure drop flow meter 2,5 ℓ/min and 4 ℓ/min Pressure drop flow meters 4 ℓ/min
+ valve completely open
1000 1000
100 100
∆p [mbar]
∆p [mbar]
0 Kv=0,03
0,5 Kv=0,03
1 Kv=0,03
1,5 Kv=0,08
2 Kv=0,19
2,5 Kv=0,33
3 Kv=0,49
3,5 Kv=0,61
TA Kv=0,64 T.A.
10 10
10 100 1000 10 100 1000
Q [ℓ/h] Q [ℓ/h]
= No. of turns for opening adjustment device 2 = No. of turns for opening adjustment device 2
0,7
0,6
0,5
0,4
Kv
0,3
0,2
0,1
0
0 0,5 1 1,5 2 2,5 3 3,5 4
No. of turns for opening adjustment device
17
Ball valves kit for Topway manifolds (all versions)
Tronchetti separati
Technical data Sealing O-Ring
Valve body thread with Female connection: UNI EN 10226-1 Upper shaft seal O-Ring: VITON 70 Sh A (ASTM D2240)
(ISO 7-1:1994) Lower shaft seal O-Ring: EPDM Peroxide 70 Sh A (ASTM D2240)
Male connection valve sleeve thread: UNI EN ISO 228-1 Shank seal O-Ring: EPDM Peroxide 70 Sh A (ASTM D2240)
Shank and nut thread: UNI EN ISO 228-1
TOTAL PASSAGE
Flow direction: in both directions
Minimum and maximum operating temperature: -20°C/+120°C **
Maximum pressure (T=120°C): 10 bar
Nominal pressure (T=20°C): see tables below
** In the absence of steam; use with water and glycol mixtures
for temperatures below 0 °C
Right-angle Progress ball valves with thermometers and Right-angle Progress ball valves with pipe union for
pipe unions thermometer and thermometers
Thermometer scale 0-80 °C - PN 30 bar - Size: 1 “ Thermometer scale 0-80 °C - PN 25 bar - Size: 1”1/4
Right-angle Progress ball valves with pipe union Straight Progress ball valve with thermometers and pipe unions
Size: 3/4” PN 40 bar; 1” PN 30 bar; 1”1/4 PN 25 bar Thermometer scale 0-80 °C - PN 30 bar - Size: 1”
Straight Progress ball valves with pipe union for thermometer Straight Progress ball valves with pipe union
and thermometers
Thermometer scale 0-80 °C - PN 25 bar - Size: 1”1/4 Size: 3/4” PN 40 bar; 1” PN 30 bar; 1”1/4 PN 25 bar
18
Accessories for Topway manifolds (all versions)
Grafico valvola di sovrapressione
Terminal kit with by-pass 0,6 7
0,5 6
valvola
5
position
0,4 4
p [bar]
3
Posizione
0,3
2
Valve
1
0,2 0
0,1
0
0 0,5 1 1,5 2 2,5 3
Q [m3/h]
1" 1"1/4
309
309
210 max.
210 max.
Size: 1” and 1”1/4
Maximum operating temperature: 110 °C.
Maximum operating pressure: 6 bar.
Thread UNI EN ISO 228-1
60
72
83 95
C
Thread
UNI EN ISO 228-1
A A
B
B C
Model A
[mm] [mm]
72 mm 24x19 24x19 36 58
3/4" EK 3/4" EK 36 49,5
The extension kit for Topway manifolds is combined with the Splitter fitting for manifolds with 24x19 or 3/4“ Eurocone,
Progress angled valve kit in order to space the flow and return center distance 50 mm. Splitter outlets center distance: 36
pipes to have more space available both during installation and mm. Thread UNI EN ISO 228-1
operation (see diagram).
Pack with 12 red bands to lock regulator Varia air vent valve nickel-plated
19
Tecno-Varia air vent valve nickel-plated Drain valve nickel-plated
Charge and drain valve, nickel-plated 1/2” with male Terminal pair with manual vent valve and adjustable tap
3/4” adjustable connection
36 mm
Size: 1” - 1/2”
38 mm
92 mm
G1
3/4”
Size: 1” with O-Ring.
Complete with 1/2” manual air vent valve and
1/2“ water filling / draining tap with adjustable 3/4” connection.
Kit thermostatic shutter 24x19 and 3/4” Eurocone Blue cap for valves
Red cap for manifolds Tee union with pipe union for thermometer
Size: 24x19
Size: 0 ÷ 80 °C
20
Instructions for the selection of lockshields/flow meter with a capacity on the basis of the manifold installed
A B C
= + = + = +
D D
Size:
for manifolds 1”
B for manifolds 1”1/4 D
24x19 and 3/4” Eurocone
Nickel-plated reduction
Nickel-plated blind plug
Size:
Size:
3/4” M x 3/8” F - 3/4” M x 1/2” F
1/2” M (*) - 3/4” M (*) - 1” M (*) - 1”1/4 M (*)
1” M x 3/8” F - 1” M x 1/2” F
3/4” F - 1” F
1” M x 3/4” F - 1”1/4 M x 1/2” F
24x19 F blind Monoblocco seal (*)
1”1/4 M x 1” F
(*) = with o-ring
With o-ring
Thread UNI EN ISO 228-1
Thread UNI EN ISO 228-1
Size: Size: 1” M x 1” M
1” M x 1” M - 1”1/4 M x 1”1/4 M 1”1/4 M x 1”1/4 M
1”1/4 M x 1” M (*) With o-ring
3/4” M x 3/4” M Thread UNI EN ISO 228-1
Thread UNI EN ISO 228-1
(*) reduction
Size:
1” - 1”1/4
21
Couple double metal holder Couple single plastic holder
Size: Size:
3/4” - 1” - 1”1/4 3/4” - 1” - 1”1/4
200 mm
26 mm
C 69 69 74
D 92 96 106
210 mm
210 mm
200 mm
30 mm 26 mm
POS. 3/4" 1" 1"1/4
B-B [mm] [mm] [mm]
C C A 39 39 44
D D B 62 66 76
C 65 65 70
For wall fixing
9,5 mm
8,2 mm
(*) When installing the cassette from 80 mm brick thickness to move the collars of
the brackets on the B-B references..
(**) Do not install in boxes for 80 mm brick thickness.
22
Expansion vessel kit for connection to Topway distribution manifold in Metalbox Plus
L
B
A
260
500
Complete with: Kit expansion vessel 10 liter can only be installed in boxes for
expansion vessel: 8, 10 litres; mounting plate with screws for partition of 120 mm. Width 260 mm x height 490 mm.
installation in metal box; copper pipe Ø18x1 prepared for con-
nection tap loading/unloading 1/2” diameter copper pipe Ø10x1
derivation with nut 3/8” for connection to expansion vessel;
monoblocco seal for copper pipe Ø18x1; shank 1/2” - 24x19
with O-Ring for connection to Topway manifold; gasket 3/8”.
Note:
Recommended number of ways of Topway 1“ manifolds: Recommended number of ways of Topway 1“1/4 manifolds:
- with 8-liter expansion vessel in Metalbox Plus for 80 and - with 8-liter or 10-liter expansion tank in Metalbox Plus for
120 mm partition 120 mm partition
- with 10-liter expansion tank in Metalbox Plus for 120 mm
partition
L N° A B B L N° A B B
[mm] ways [mm] [mm] [mm] [mm] ways [mm] [mm] [mm]
500 2 430 - - 500 2 430 - -
600 12 2 430 530 540 600 12 2 430 565 550
700 12 2 430 530 540 700 12 2 430 565 550
700 12 3 480 580 590 850 12 3 480 615 600
850 12 4 530 630 640 850 12 4 530 665 650
850 12 5 580 680 690 850 12 5 580 715 700
850 12 6 630 730 740 1000 12 6 630 735 720
1000 12 7 680 780 790 1000 12 7 680 815 800
1000 12 8 730 830 840 1000 12 8 730 865 850
1000 12 9 780 880 890 1200 12 9 780 915 900
1200 12 10 830 930 940 1200 12 10 830 965 950
1200 12 11 880 980 990 1200 12 11 880 1015 1000
1200 12 12 930 1030 1040 1200 12 12 930 1065 1050
23
Control T
electrothermic heads
1
2
J
8 9 5
3
4
6
Construction
A Polycarbonate case
2 Stainless steel spring
3 Indicator in PPA (35% FV)
4 Radial stop ring in steel
5 Polycarbonate shutter support
6 Polycarbonate base
7 M30x1.5 ring nut in PA 66 (50% FV) or in nickel-plated
brass UNI EN 12164 CW614N
8 PVC cable
9 1 A 250 V microswitch
J Wax expansion electrothermal actuator
24
Basic wiring box 6T
for electro-thermic heads
25
Monoblocco and Three-pieces seals
Monoblocco seal 24x19 for copper pipe 3/4” Eurocone seal for copper pipe
Sizes: Ø 10 - Ø 12 - Ø 14 - Ø 15 - Ø 16 Sizes: Ø 12 - Ø 14 - Ø 15 - Ø 16
3
2
Size: Ø 18
1
Construction and Technical data
2 A Nut in nickel-plated brass UNI EN 12165 CW617N
2 B Adapter in brass UNI EN 12164 CW617N
3 C Ogive in peroxide EPDM
Maximum torque:
Construction and Technical data - Ø 12 mm = 35÷40 Nm (*) - 68÷80 Nm (**)
A Nut in nickel-plated brass UNI EN 12165 CW617N
B Metal components in brass UNI EN 12164 CW617N - Ø 14 mm = 35÷40 Nm (*) - 68÷80 Nm (**)
C O-Ring fitting in NBR - Ø 15 mm = 35÷40 Nm (*) - 68÷80 Nm (**)
- Ø 16 mm = 35÷40 Nm (*) - 68÷80 Nm (**)
Maximum pressure: 10 bar
(*) Annealed copper pipe
Maximum temperature: 100 °C
(**) Semi-hard copper pipe
Maximum torque:
- Ø 10 mm = 30÷35 Nm
- Ø 12 mm = 35÷40 Nm
- Ø 14 mm = 40÷45 Nm
- Ø 15 mm = 40÷45 Nm
- Ø 16 mm = 45÷50 Nm
- Ø 18 mm Standard seal = 50÷55 Nm
- Blind Monoblocco (plug) = 30÷35 Nm
26
Monoblocco seal 24x19 for multilayer pipe Monoblocco seal 3/4” Eurocone for multilayer pipe
Sizes: Sizes:
12x1,6 - 14x2 - 16x2 - 16x2,25 - 18x2 - 20x2 - 20x2,5 16x2 - 20x2
26x3 (*)
(*) thread M32x1,5
5
5
1
1 4
4 2
2 3
3
5 5
5 5
27
Monoblocco seal 24x19 for plastic, PEX, PP pipe Monoblocco seal 3/4” Eurocone for plastic, PEX, PP pipe
Sizes:
12x1 - 12x2 - 15x1,7 - 16x1,5 - 16x2 - 16x2,2 - 17x2 - 20x2 - 25x2,3 (*) Sizes:
12x2 with O-ring
(*) Thread M32x1,5 16x2 with O-ring
17x2 with O-ring
20x2 with O-ring
3
3
1
4 1
4
2
2
28
Monoblocco seal 24x19 for plastic PB pipe Three-pieces 24x19 and 3/4” Eurocone for PEX, PERT and
Multilayer pipe
Size Ø 15 Sizes:
24x19: 12x2 - 14x2 - 17x2
When using Emmeti compression fittings for Polybutylene pipe, 3/4” EK: 12x2 - 14x2 - 17x2
please ansure you use the plastic pipe insert provided for by the
manufacturer of the pipe you are using..
2 5
1 1
4
3
5 2
4 3
4 5 5
Female 24x19 - Male M32x1,5 fitting Straight Male 1/2 ”- Male M32x1.5 fitting
Sizes: Sizes:
24x19 - M32x1,5 1/2” - M32x1,5
Complete with O-Ring and adapter on Female side Complete with O-Ring
29
Accessories for Monoblocco
CH 27-30 open poligonaly key CH 38 key for Multilayer 26x3 Monoblocco seals
30
Metalbox Plus
recessed zinc-coated metal cabinet, adjustable dept
Height 600 mm
Telescopic case
Door frame flush with the plaster
Telescopic base
Adjustable foot
Uses Accessory
Zinc-coated metal cassette with plastic frame and door, white Key lock
colour RAL 9010, for 120 mm brick thickness.
Suitable for flush mounting with adjustable depth.
It is supplied with a slotted screwdriver lock, height adjustable
feet from 0 to 100 mm and a rubble protection metal cover.
Frame and door fto fit flush with wall 3 mm..
31
Metalbox
recessed and external zinc-coated metal cabinet
32
Dimensional data of Metalbox Plus recessed zinc-coated metal cabinet, adjustable depth
A
12 L 12 96 min 148 L 155 max
12
480
540
Altezza 600 mm
500
H600
700
Height 600 mm
Metalbox Plus from 80 to 120 Metalbox Plus from 80 to 120 Metalbox Plus from 80 to 120 mm Metalbox Plus from 80 to 120 mm
mm brick thickness (front view) mm brick thickness (side view) brick thickness (front body view brick thickness (side body view
+ frame + door) + frame + door)
30 B 30 L 140
30
465
Altezza 700 mm
H700
Height 700 mm
Metalbox body for external Metalbox for external surface Metalbox for external surface
surface (front view) (front carter view + door) (side carter view + door)
690
740
Altezza 850 mm
700
H850
950
Height 850 mm
Metalbox from 120 mm Metalbox from 120 mm Metalbox from 120 mm brick thick- Metalbox from 120 mm brick thickness
brick thickness (front view) brick thickness (view side) ness (front body view + frame door) (side body view + frame + door)
L M IN L MIN
B B
A A
500
50 50
480
200
200
H600
H700
700
50
200
700
H850
950
Combined with 1” Topway manifolds in metal cabinet Combined with 1”1/4 Topway manifolds in metal cabinet
N° ways A [mm] B 1 [mm] B 2 [mm] L min [mm] N° ways A [mm] B 1 [mm] B 2 [mm] L min [mm]
2 172 270 280 500 2 182 316 300 500
3 222 320 330 500 3 232 366 350 600
4 272 370 380 500 4 282 416 400 600
5 322 420 430 500 5 332 466 450 700
6 372 470 480 600 6 382 516 500 700
7 422 520 530 600 7 432 566 550 850
8 472 570 580 700 8 482 616 600 850
9 522 620 630 700 9 532 666 650 850
10 572 670 680 850 10 582 716 700 1000
11 622 720 730 850 11 632 766 750 1000
12 672 770 780 1000 12 682 816 800 1000
Note: LMIN including dimensions of press fittings Note: LMIN including dimensions of press fittings
1 With straight Progress valve kit 1” with thermometers and con- 1 With straight Progress valve kit 1”1/4 with thermometers and connec-
nections tions
2 With square Progress valve kit 1” with thermometers and connec- 2 With square Progress valve kit 1”1/4 with thermometers and connec-
tions tions
34
With Progress valves + thermometers and by-pass terminal kit
L M IN L MIN
A A
500
480
50 50
200
200
H600
H700
700
50
200
700
H850
950
Combined with 1” Topway manifolds in metal cabinet Combined with 1”1/4 Topway manifolds in metal cabinet
N° ways A 1 [mm] A 2 [mm] L min 1 [mm] L min 2 [mm] N° ways A 1 [mm] A 2 [mm] L min 1 [mm] L min 2 [mm]
2 357 367 500 500 2 415 395 600 500
3 407 417 500 500 3 465 445 600 600
4 457 467 600 600 4 515 495 700 600
5 507 517 600 600 5 565 545 850 700
6 557 567 700 700 6 615 595 850 700
7 607 617 700 700 7 665 645 850 850
8 657 667 850 850 8 715 695 850 850
9 707 717 850 850 9 765 745 1000 850
10 757 757 850 850 10 815 795 1000 850
11 807 817 1000 1000 11 865 845 1000 1000
12 857 867 1000 1000 12 915 895 1000 1000
Note: LMIN including dimensions of press fittings Note: LMIN including dimensions of press fittings
1 With straight Progress valve kit 1” with thermometers and con- 1 With straight Progress valve kit 1”1/4 with thermometers and con-
nections nections
2 With square Progress valve kit 1” with thermometers and connec- 2 With square Progress valve kit 1”1/4 with thermometers and connections
tions
35
Termobox
plastic box for manifolds
Uses
Box for manifolds for built-in installation, suitable for hot
and cold water and for manifolds for floor systems up to 1”.
Runners are incorporated in the rear wall, appropriately
spaced, for the manifold supports. All side walls are equipped
with removable panels so that manifolds and pipes can be
easily adjusted. Supplied complete with plastic netting and
cover for protection during site work
36
Support kit for Topway manifolds in bars without mechanics
Size:
3/4” - 1”
Size:
400 mm
200 mm
Termobox 1” A+C 3/4” A+C 3/4” A+C 1” B+C 3/4” B+C 3/4” B+C 1” A+B+C 3/4” +B+C 3/4” A+B+C
takeoff takeoff takeoff takeoff takeoff takeoff
50 mm 36 mm 50 mm 36 mm 50 mm 36 mm
310 x 310 2 ways 3 ways 4 ways - 2 ways 2 ways - - -
460 x 310 5 ways 6 ways 8 ways 4 ways 5 ways 6 ways 3 ways 4 ways 5 ways
610 x 310 8 ways 9 ways 12 ways 7 ways 8 ways 11 ways 6 ways 7 ways 9 ways
37
Notes
38
Notes
39
EMMETI S.p.A. Unipersonale Rev. 0_EMMETI_Data sheet_09.2022_IT/Creative Design Team_SR
9901028200001
Via Brigata Osoppo, 166 TO KNOW MORE
33074 Vigonovo frazione di Fontanafredda (PN) - Italia GO TO OUR SITE
Tel. 0434.567911 WWW.EMMETI.COM
Fax 0434.567901
www.emmeti.com
info@emmeti.com