You are on page 1of 40

Topway

Brass distribution manifold

Technical sheet 10 · GB 10 comfort delivered by


A versatile and complete system
The Topway bar manifold, with its multitude of components and accesso-ries, is the perfect
solution to current system engineering needs. It offers flexible solutions for various system
configurations. This manifold makes it possible to set the temperature in any room through
the installation of electro-thermal actuators so as to automatically control each circuit using
a thermostat. The Topway manifold can be provided an extensive range of accessories, rang-
ing from adjustable drain taps to air valves and from electro-thermic heads to flow meters.
Now, even small houses can accommodate a truly advanced system.

Fast, easy and safe installation


Emmeti provides the installer with a system consisting of interchangeable components, thus
ensuring ease and speed of installation in safe manner. The Topway system has been engi-
neered for ease of installation and hence time savings to the installer, who can also assemble
complex sys-tems in self-contained areas, are considerable, for the greatest benefit of the
customer.
Index

50 mm
24 mm

Quality and reliability .................................................................................................................................................................................................................


50 mm 24x19 4

Topway, pre-assembled bar manifold with incorporated flow meters ...................................................................................................... 5

How to install your pre-assembled


24 mm 26 mm Topway ............................................................................................................................................................... 6
3/4”

24x19 Eurocone
Topway Compact, distribution manifold with lockshields/flow meters incorporated ...................................................................... 8
50 mm

24 mm
Topway, single bar distribution manifold ..................................................................................................................................................................... 10
24x19

Topway R, distribution manifold for radiators ............................................................................................................................................................. 12

Ball valves kit for Topway manifolds (all versions) .................................................................................................................................................. 18

Accessories for Topway manifolds (all versions) ...................................................................................................................................................... 19

Control T, electro-thermic heads ....................................................................................................................................................................................... 24

6T basic unit for electro-thermic heads ....................................................................................................................................................................... 25

Monoblocco and Three-pieces seals .............................................................................................................................................................................. 26

Accessories for seals ................................................................................................................................................................................................................ 30

Metalbox and Metalbox Plus, recessed galvanized metal box, telescopic....................................................................................................31

Termobox, plastic manifold box .......................................................................................................................................................................................... 36


3
Quality and reliability

High quality standard materials, sturdy components and a durable fini-


sh make the Topway System both reliable and functional: the longevity
of the system is increased and the need for ongoing maintenance is
decreased.
The company places great importance on quality throughout the fully
automated manufacturing process, thus, keeping the manufacturing
and fluid dynamic characteristics of a whole lot constant
All of the components are subject to stringent controls and additional
final acceptance tests are performed on the hydraulic bench to assess
perfor-mances in critical operating conditions**.
* Pre-assembled manifolds are 100% tested before packaging.

Customised comfort
Thanks to the Topway System, houses can be subdivided into various
unlimited areas, by simply applying thermoelectric heads for valves
monitoring purposes.
The plumber is thus able to regulate the temperature in every room
in a rational fashion, without architectural hindrances and without
requiring further operations, as the outlet box is the only tool involved.
In other words, the Topway header is the first, truly effective control-
ler of the whole heating system.

Long term savings


The bigger beginning investment for the purchase of the materials is
reward by the remarkable reduction of installation and management
costs.

Independent and tailor-made temperature monitoring in each room,


without waste, offers energy saving benefits visible throughout the
duration of the system, or rather: heat the right place at the right time.

EMMETI brings unparalleled financial benefits to your household.

4
Topway
100%
Pre-assembled bar manifold nickel-plated Tested

with flow meters included

The range Technical data


– 1”, 24x19 thread, takeoffs 50 mm (flow and return) from 2 to 12 Maximum operating temperature: 90 °C
ways, flow meters 0÷450 ℓ/min
mmor 0÷2,5 ℓ/min. Maximum operating pressure: 6 bar
– 1”, 3/4” Eurocone thread, takeoffs 50 mm (flow and return) Head thread: G 1” - 1”1/4
from 2 to 12 ways, flow meters 0÷4 ℓ/min. Side ways thread: 24x19 - 3/4” Eurocone
– 1”1/4, 24x19 thread, takeoffs 50 mm (flow and return) from Note: 24x19 thread: 24 mm diameter gas thread and
4 to 12 ways, flow meters 0÷4 ℓ/min. 19 screw threads per inch.
– 1”1/4, 3/4” Eurocone thread, takeoffs 50 mm (flow and re- Note: Seal on thread of heads ONLY with o-ring.
turn) from 6 to 12 ways, flow meters 0÷4 ℓ/min. DO NOT USE taperad threads.

Construction
All Topway manifold distribution heads are nickel/brass plated.
Brass header 24 mm through a bar
retrieved 26drawing
mm process UNI EN
12168 CW614N. Seals in EPDM 70. 3/4”
Topway pre-assembled manifold is supplied together with:
• Lockshields with
24x19flow meters included on inlet ( (0÷4 ℓ/min or
Eurocone
0÷2,5 ℓ/min).
• Manual adjustment valves set up to take thermo-electric
heads.
• n° 2 blanking plugs 1” or 1”1/4 complete with O-Ring.
• n° 2 water drain valves 1/2” with plugs.
• n° 2 Tecno-Varia air vent 1/2” with bleed (lateral + manual).
• n° 2 double metal holders 1” or 1”1/4.
Note: n° 2 1” or 1”1/4 Progress ball valves with red and blue but-
terfly handles, with or without thermometer holder and ther-
mometer, are supplied optionally.

5
How to install your pre-assembled Topway

A 2 3 4 5

Outlet

Inlet

7
8

1 Progress ball valve Note


2 Control T electro-thermic head It is advisable to fit a differential by pass valve to avoid hydraulic
3 SINTESI chronothermostat imbal-ances which can occur if one or more zones are excluded.
4 Tecno-Varia air vent valve Check the current flow across the thermostat contacts
in relation to the starting current absorbed by the ther-
5 Radiator
mo-electric valve-heads. In the event of overload, use a relay.
6 Drain valve
Thermo-electric valve-heads with auxiliary microswitches can
7 Full valve be used for switching off the pump when the valves are closed
8 Full lockshield (if the current absorp-tion of the pump exceeds the current flow
9 Multi-layer pipe across the contacts, use an intermediate relay).

6
Topway pre-assembled distribution manifold with lockshields with flow meters included

B
F L A

G1 o G1¼
200

E

C
50 24x19 D
G ¾ Eurocone

1” 1”1/4
A mm 26,5 30,5
B mm 51 58,5
C mm 56,5 60,5
D mm 81 89,5
E mm 361,5 371,5
F mm 97 135

Model 2 ways 3 ways 4 ways 5 ways 6 ways 7 ways 8 ways 9 ways 10 ways 11 ways 12 ways
1” L mm 174 224 274 324 374 424 474 524 574 624 674
1”1/4 L mm - - 282 332 382 432 482 532 582 632 682

7
Topway Compact
100%
distribution manifold Tested

with lockshields or flow meters included

The range Construction


–  1”, 24x19 thread, takeoffs 50 mm with valves (return) and All Topway Compact manifold distribution heads are nickel/
lockshields with flow meter incorporated (flow), and drain brass plated.
valves, from 2 to 12 ways Brass header retrieved through a bar drawing process UNI EN
50 mm 12168 CW614N. Seals in EPDM 70.
– 1”, 24x19 thread, takeoffs 50 mm with valves (return) and
lockshields (flow) and drain valves, from 2 to 12 ways The Topway Compact header is supplied together with:
24 mm • Lockshields or lockshields with flow meter incorporated
–  1”, 24x19 thread, takeoffs 50 mm with valves (return) and
(0÷4 ℓ/min).
lockshields with flow meter incorporated (flow) from 2 to 12
24x19 • Manual adjustment valves set up to take thermo-electric
ways
head.
–  1” 3/4” Eurocone thread, takeoffs 50 mm with valves (return) • n° 2 water drain valves 1/2” with plugs (where indicated).
and lockshields with flow meter incorporated (flow) from 2 • n° 2 double adjustable holders for installation in metal box or
to 12 ways wall.
Nota: nr. 2 1” Progress ball valves with red and blue butterfly
handles, with or without thermometer holder and thermometer,
are supplied optionally.

50 mm

24 mm
Technical data
Maximum operating temperature: 110 °C with lockshields;
90 °C with flow meters
24x19 Maximum operating pressure: 10 bar with lockshields;
6 bar with flow meters
Head thread: G 1”
Side ways thread: 24x19 - 3/4” Eurocone
Note: 24x19 thread: 24 mm diameter gas thread and 19 screw
threads per inch.
Note: seal on thread of heads ONLY with o-ring.
DO NOT USE taperad threads.

8
Topway Compact distribution manifold kit with lockshields with flow meters included,
adjustable supports

B
F L A POSITION A-A POSITION B-B
1” 1”
A mm 39 39
G1
B mm 66 66
C mm 69 65
D mm 96 92
G
E mm 320 320
E
F mm 97 97

G mm 200 210

50 C
24x19 D

Model 2 ways 3 ways 4 ways 5 ways 6 ways 7 ways 8 ways 9 ways 10 ways 11 ways 12 ways
1” L mm 165,5 215,5 265,5 315,5 365,5 415,5 465,5 515,5 565,5 615,5 665,5
Note: Pressure drops and values see the following pages

Topway Compact with bibcocks and lockshields with or without flow meters included,
adjustable supports

B
F L
A POSITION A-A POSITION B-B
A mm 39 39
B mm 66 66
G1
C mm 69 65
D mm 96 92
E mm 320 320
G E F mm 97 97
G mm 200 210

50 M 24x19
C
D
G ¾ Eurocone

Model 2 ways 3 ways 4 ways 5 ways 6 ways 7 ways 8 ways 9 ways 10 ways 11 ways 12 ways
1” L mm 114 164 214 264 314 364 414 464 514 564 614

Note: Pressure drops and values see the following pages

9
Topway
100%
single bar distribution manifold Tested

50 mm
50 mm

50 mm

The range Construction


50 mm
– 1”, thread 24x19, takeoffs 50 mm, with valves (return) from 2 All Topway distribution manifolds and accessories are nick-
to 12 ways el-plated. Brass header retrieved through a bar drawing
process UNI EN 12164 CW614N brass raw material.
– 1”1/4, thread 24x19, takeoffs 50 mm, with valves (return) 24 mm 26 mm
from 4 to 12 24 mm
ways 26 mm
3/4”
3/4”
– 1”, thread 3/4” Eurocone, takeoffs 50 mm, with valves (re-
turn) from 2 to 12 ways 24x19
Technical
24 mm data Eurocone
26 mm
24x19 Eurocone 3/4”
– 1”1/4, thread 3/4” Eurocone, takeoffs 50 mm, with valves (re- Max operating temperature: 110 °C (90 °C with flow meter)
turn) from 6 to 12 ways Max operating pressure: 10 bar (6 bar with flow meter)
24x19 Eurocone
– 1”, thread 24x19, takeoffs 50 mm, with lockshields (flow) from Head thread: G 3/4” - 1” - 1”1/4
2 to 12 ways24 mm 26 mm Side ways thread: 24x19 - 3/4” Eurocone
– 1”1/4 thread 24x19, takeoffs 50 mm,3/4”
with lockshields (flow) Note: 24x19 thread: 24 mm diameter gas thread and 19 screw
threads per inch.
from 4 to 12 ways
Note: seal on thread of heads ONLY with o-ring.
24x19
– 1”, thread 3/4” Eurocone
Eurocone, takeoffs 50 mm, with lockshields DO NOT USE taperad threads.
(flow) from 2 to 12 ways
– 1”1/4 thread 3/4” Eurocone, takeoffs 50 mm, with lockshields
(flow) from 6 to 12 ways
– 1”, thread 24x19, takeoffs 50 mm, with lockshields and flow
meters included (flow) from 2 to 12 ways
– 1”1/4, thread 24x19, takeoffs 50 mm, with lockshields and
flow meters included (flow) from 4 to 12 ways
– 1”, thread 3/4” Eurocone, takeoffs 50 mm, with lockshields
and flow meters included (flow) from 2 to 12 ways
– 1”1/4, thread 3/4” Eurocone, takeoffs 50 mm, with lockshields
and flow meters included (flow) from 6 to 12 ways
– 1”, thread 3/4” Eurocone, takeoffs 50 mm, with lockshields
and flow meters included (flow) from 2 to 12 ways
– 3/4”, thread 24x19, takeoffs 36 mm, from 2 to 12 ways
– 3/4”, thread 24x19, takeoffs 50 mm, from 2 to 12 ways
– 1”, thread 24x19, takeoffs 50 mm, from 2 to 12 ways
– 1”, thread 3/4” Eurocone, takeoffs 50 mm, from 2 to 12 ways
– 1”1/4, thread 24x19, takeoffs 50 mm, from 4 to 12 ways

10
Topway return manifold nickel-plated with valves
L
Ø38
2 3 4 5 6 7 8 9 10 11 12
Model

27
ways ways ways ways ways ways ways ays ays ways ways G 1/2

1” L mm 164 214 264 314 364 414 464 514 564 614 664
1”1/4 L mm 170 220 270 320 370 420 470 520 570 620 670
1/2”F
Note: threads takeoff 50 mm
50 mm 24x19
G 3/4 Eurocone

Topway flow manifold nickel-plated, with lockshields


L
30 mm

2 3 4 5 6 7 8 9 10 11 12
Model G 1/2
ways ways ways ways ways ways ways ways ways ways ways
1” L mm 164 214 264 314 364 414 464 514 564 614 664

20 mm
1”1/4 L mm 170 220 270 320 370 420 470 520 570 620 670
G 1/2
Note: threads takeoff 50 mm 50 mm 24x19
G 3/4 Eurocone

Topway flow manifold nickel-plated, with flow meters L

30 mm

75 MAX

2 3 4 5 6 7 8 9 10 11 12
Model ways ways ways ways ways ways ways ways ways ways ways G 1/2
1” L mm 164 214 264 314 364 414 464 514 564 614 664
1”1/4 L mm 170 220 270 320 370 420 470 520 570 620 670
20 mm

G 1/2
Note: threads takeoff 50 mm
50 mm 24x19
G 3/4 Eurocone

Topway distribution manifold nickel-plated, with takeoffs

2 3 4 5 6 7 8 9 10 11 12 G 1/2
Model
ways ways ways ways ways ways ways ways ways ways ways
3/4” L mm 85 121 157 193 229 265 301 337 373 409 445
Note: threads takeoff 36 mm
24x19
3/4” L mm 103 153 203 253 303 353 403 453 503 553 603 G 3/4 Eurocone
36-50 mm mod. 3/4”
1” L mm 114 164 214 264 314 364 414 464 514 564 614
50 mm mod. 1” and 1”1/4
1”1/4 L mm – – 220 270 320 370 420 470 520 570 620
Note: threads takeoff 50 mm

11
Topway R
distribution manifold for radiators

The range Construction


–  1”, 24x19 thread, takeoffs 50 mm (flow and return) from 2 to Topway R manifold distribution heads are nickel/brass plated.
12 ways Brass header retrieved through a bar drawing process TN UNI
50 mm EN 12168 CW614N. Seals in EPDM 70.
–  1”1/4, 24x19 thread, takeoffs 50 mm (flow and return) from 4
to 12 ways 24 mm The Topway R pre-assembled header is supplied together with:
• Manual adjustment valves set up to take thermo-electric
24x19 heads.
• n° 2 blanking plugs 1” complete with O-Ring.
Technical data • n° 2 double metal holders 1”
Maximum operating temperature: 110 °C Note: nr. 2 Progress ball valves 1” with red and blue butterfly
Maximum operating pressure: 10 bar handles, with pipe union with or without thermometer, are sup-
Head thread: G 1” plied optionally.
Side ways thread: 24x19
Note: 24x19 thread: 24 mm diameter gas thread and 19 screw
threads per inch.
Note: Seal on thread of heads ONLY with o-ring.
DO NOT USE taperad threads.

Topway R distribution manifold for radiators


B
F L A

1” 1”1/4
A mm 26,5 30,5
B mm 51 58,5
C mm 56,5 60,5
D mm 81 89,5
200

E
E mm 323 364
F mm 97 135

C
50 24x19
D

Model 2 ways 3 ways 4 ways 5 ways 6 ways 7 ways 8 ways 9 ways 10 ways 11 ways 12 ways
1” L mm 124 174 224 274 324 374 424 474 524 574 624
1”1/4 L mm - - 232 282 332 382 432 482 532 582 632

12
Manual valve (suitable for electrothermic heads)

9 1 Shutter body in brass UNI EN 12164 CW614N nickel plated


8 2 O-ring for shutter body steadying in EPDM
7
6 3 Shutter stem in brass UNI EN 12164 CW614N
1 4 Shutter steadying in EPDM
2 5 Washer for lock (gasket seal)
in brass UNI EN 12164 CW614N
6 O-ring for rod steadying in EPDM
3 7 Collar for shutter in brass UNI EN 12164 CW614N nickel plated
5 8 Spindle in steel AISI 304
4
9 Cap in blue ABS (RAL 5005)

Pressure drops valve with manual handwheel Valve with manual handwheel: Kv values

1000 2,50
0,5 Kv=1,24
1 Kv=1,80 2,00

1,5 Kv=2,05
1,50
2 Kv=2,20
Kv

2,5 Kv=2,32 1,00


∆p [mbar]

TA Kv=2,40
100 0,50

0,00
0 0,5 1 1,5 2 2,5 3

No. of turns for knob opening

10
10 100 1000
Q [l/h]

TA = All open.
The above values refer to water temperature at 15 °C.
∆p = ∆p supply + ∆p return

= No. of turns for knob opening

13
Transformable double regolating lockshield

2 1

Fig. B
Fig. A

Lockshield adjustment (Fig. A) Replacement of the regulator with a flow meter cartridg (Fig. B)
The lockshield is delivered in a partially OPEN position, to carry The Emmeti transformable lockshield allows you to add a flow
out the calibration: meter:
1 - Remove the cap 1; - on an operating system;
2 - Turn the cap 1 over, and, using the impression inside it, - with no water leakage;
manually turn the lockshield 2 anticlockwise until you feel - con una operazione semplice e rapida.
resistance; 1 - Close the lockshield using the cap A;
3 - With an allen key ch 4, screw completely, until it stops the 2 - Remove the regulator B g an Allen key and a screwdriver;
regulator 3; 3 - Insert the measuring cartridge C the ring nut D.
The lockshield is now ready for flow setting: 4 - Manually rotate the ring nut D counterclockwise until you
4 - Unscrew the regulator 3 anti-clockwise, by the desired feel resistance.
number of turns (see diagram); 5 -Calibrate the measuring cartridge C until the desired flow
5 - Insert the cap again. rate is reached (directly shown on the flow meter).
It is also possible to seal the cap in the position reached by using
6 -Raise the ring nut D l it clicks, indicating that it is in the correct
lead, exploiting the holes in the fins 4 to secure it directly to the position: it is now possible to close and open the circuit with-
manifold, thereby preventing any tampering. out chan-ging the calibration.

Lockshield pressure drops Lockshield + totally open valve pressure drops


1000 1000
∆p [mbar]
∆p [mbar]

100 100

0 Kv = 0,05
0 Kv= 0,05
0,5 K v =0,10
1 Kv = 0,26
0,5 Kv= 0,10
1,5 Kv=0,46 1 Kv= 0,26
2 Kv =0,75 1,5 kv=0,45
2,5 Kv=1,08 2 Kv =0,72
T.A. Kv= 1,2 2,5 Kv=0,98
10 T.A. Kv =1,07
10 100 1000 10
10 100 1000
Q [ℓ/h]
Q [ℓ/h]
TA = All open. The above values refer to water temperature at TA = All open. The above values refer to water temperature at
15 °C. 15 °C.
= No. of turns for opening adjustment device C ∆p = ∆p supply + ∆p return
= No. of turns for opening adjustment device C

14
Lockshield: Kv values Kv values at different lockshield openings,
with totally open valve

1,2
1,2

1 1

0,8 0,8

0,6
Kv

0,6

Kv
0,4 0,4

0,2 0,2

0 0
0 0,5 1 1,5 2 2,5 0 0,5 1 1,5 2 2,5
No. of turns for opening of lockshield adjustment screw No. of turns for opening of lockshield adjustment screw

Example of calculation:
Calculation of the pressure loss ∆p with a water flow rate Q of 200 ℓ/h determined by valve and lockshield with opening of 2.5
turns of the controller 3 .
1° method: use of pressure drop diagram Q = 200 ℓ/h ∆p = 40 mbar
the Kv represents the flow Q in m3/h at an ∆p equal to 1 bar: Kv = Q /√∆p
la relation that connects the ∆p (bar) to the flow Q (m3/h) is the following: ∆p = Q2 / Kv2
2° method: use of Kv diagram Kv = 0,98 Q = 0,2 m3/h
∆p = 0,2 2 / 0,982 = 0,04 bar

15
Lockshields with flow meters included

4
2
1

3 4

2 2

1 3
1

Step 1 and 2 Step 3

Flow regulation and interception device with set calibration Flow rate adjustment
memory and regulated flow display system. Simple, direct ca-
libration by means of indicator that displays the circuit flow. (do not use tools)
The special design also makes it possible to clean the window Flow meter is delivered in a partially OPEN position, to carry
or replace the entire measurement component with the mani- out the calibration:
fold under pressure. Step 1 manually rotate the ring nut 1 counterclockwise until
you feel resistance.
Technical data Step 2 calibrate using the adjuster 2 until the desired flow
Measurement field: 0 ÷ 4 ℓ/min or 0 ÷ 2,5 ℓ/min rate is reached (directly shown on the flow meter).
Indication error: ± 10% full-scale Step 3 raise the ring nut 1 until it clicks, indicating that it is in
Maximum operating pressure: 6 bar the correct positio: it is now possible to close and open
Maximum operating temperature: 90 °C the circuit without changing the calibration.
Pressure drops: Kv from 0,15 (1 ℓ/min) to 0,55 (4 ℓ/min)
Maximum pressure drop (off scale): Kv=9 Note: all the above operations must be performed manually.
Pressure test (25 °C max): 10 bar
It is also possible to seal the ring nut in the position reached
using a lead seal and the holes in the fins 3 to ensure it:
– directly to the manifold, preventing any tampering;
– to the flow meter, making it possible to close the flow with-
out modifying the set maximum opening calibration.

Flow meter cleaning


– Turn the ring nut 1 clockwise until the lockshield is com-
pletely closed.
– Remove the glass 4 by unscrewing it from the adjuster 2
with a 17 mm polygonal key.
– Clean the glass 4 and screw it back on the adjuster 2 .
– Turn the ring nut 1 manually counterclockwise until you
feel resistance.

16
Pressure drop flow meter 2,5 ℓ/min and 4 ℓ/min Pressure drop flow meters 4 ℓ/min
+ valve completely open

1000 1000

100 100

∆p [mbar]
∆p [mbar]

0 Kv=0,03
0,5 Kv=0,03
1 Kv=0,03
1,5 Kv=0,08
2 Kv=0,19
2,5 Kv=0,33
3 Kv=0,49
3,5 Kv=0,61
TA Kv=0,64 T.A.
10 10
10 100 1000 10 100 1000
Q [ℓ/h] Q [ℓ/h]

TA = All open. TA = All open.


The above values refer to water temperature at 15 °C. The above values refer to water temperature at 15 °C.
∆p = ∆p supply + ∆p return

= No. of turns for opening adjustment device 2 = No. of turns for opening adjustment device 2

Flow meter 2,5 ℓ/min and 4 ℓ/min: Kv values

0,7

0,6

0,5

0,4
Kv

0,3

0,2

0,1

0
0 0,5 1 1,5 2 2,5 3 3,5 4
No. of turns for opening adjustment device

17
Ball valves kit for Topway manifolds (all versions)
Tronchetti separati
Technical data Sealing O-Ring
Valve body thread with Female connection: UNI EN 10226-1 Upper shaft seal O-Ring: VITON 70 Sh A (ASTM D2240)
(ISO 7-1:1994) Lower shaft seal O-Ring: EPDM Peroxide 70 Sh A (ASTM D2240)
Male connection valve sleeve thread: UNI EN ISO 228-1 Shank seal O-Ring: EPDM Peroxide 70 Sh A (ASTM D2240)
Shank and nut thread: UNI EN ISO 228-1
TOTAL PASSAGE
Flow direction: in both directions
Minimum and maximum operating temperature: -20°C/+120°C **
Maximum pressure (T=120°C): 10 bar
Nominal pressure (T=20°C): see tables below
** In the absence of steam; use with water and glycol mixtures
for temperatures below 0 °C

The valves must be used in the fully open or closed position

Right-angle Progress ball valves with thermometers and Right-angle Progress ball valves with pipe union for
pipe unions thermometer and thermometers

Thermometer scale 0-80 °C - PN 30 bar - Size: 1 “ Thermometer scale 0-80 °C - PN 25 bar - Size: 1”1/4

Right-angle Progress ball valves with pipe union Straight Progress ball valve with thermometers and pipe unions

Size: 3/4” PN 40 bar; 1” PN 30 bar; 1”1/4 PN 25 bar Thermometer scale 0-80 °C - PN 30 bar - Size: 1”

Straight Progress ball valves with pipe union for thermometer Straight Progress ball valves with pipe union
and thermometers

Thermometer scale 0-80 °C - PN 25 bar - Size: 1”1/4 Size: 3/4” PN 40 bar; 1” PN 30 bar; 1”1/4 PN 25 bar

18
Accessories for Topway manifolds (all versions)
Grafico valvola di sovrapressione
Terminal kit with by-pass 0,6 7

0,5 6

valvola
5

position
0,4 4

p [bar]
3

Posizione
0,3
2

Valve
1
0,2 0

0,1

0
0 0,5 1 1,5 2 2,5 3

Q [m3/h]
1" 1"1/4

G 1 1/4 ISO 228-1


G 1 ISO 228-1

309

309
210 max.

210 max.
Size: 1” and 1”1/4
Maximum operating temperature: 110 °C.
Maximum operating pressure: 6 bar.
Thread UNI EN ISO 228-1

G 1 1/4 ISO 228-1


G 1 ISO 228-1

60
72
83 95

Extension kit for Topway manifolds Splitter fitting


A
Size:
M-F 1” - M-F 1”¼

C
Thread
UNI EN ISO 228-1

A A
B

B C
Model A
[mm] [mm]
72 mm 24x19 24x19 36 58
3/4" EK 3/4" EK 36 49,5

The extension kit for Topway manifolds is combined with the Splitter fitting for manifolds with 24x19 or 3/4“ Eurocone,
Progress angled valve kit in order to space the flow and return center distance 50 mm. Splitter outlets center distance: 36
pipes to have more space available both during installation and mm. Thread UNI EN ISO 228-1
operation (see diagram).

Pack with 12 red bands to lock regulator Varia air vent valve nickel-plated

Size: 1” - 1” 1/4 Size: 1/2”


With labels for identify circuits

19
Tecno-Varia air vent valve nickel-plated Drain valve nickel-plated

Size: 1/2” Size: 1/2”

Charge and drain valve, nickel-plated 1/2” with male Terminal pair with manual vent valve and adjustable tap
3/4” adjustable connection
36 mm
Size: 1” - 1/2”

38 mm

92 mm
G1

3/4”
Size: 1” with O-Ring.
Complete with 1/2” manual air vent valve and
1/2“ water filling / draining tap with adjustable 3/4” connection.

Kit thermostatic shutter 24x19 and 3/4” Eurocone Blue cap for valves

Size: for manifolds 1” and 1”1/4 Size: M30x1,5

Red cap for manifolds Tee union with pipe union for thermometer

Size: 24x19

Gas thread 24x19 in diameter


24 mm and 19 threads per inch

Thermometer Ø 40 Hand wheel for manual control

Size: 0 ÷ 80 °C

20
Instructions for the selection of lockshields/flow meter with a capacity on the basis of the manifold installed

A B C

= + = + = +
D D

Kit lockshield with incorporated Kit flow meter


flow meter 0÷4 ℓ/min
Size:
Size: 0 ÷ 2,5 ℓ/min
0 ÷ 4 ℓ/min A 0 ÷ 4 ℓ/min
C
0 ÷ 6 ℓ/min

Kit lockshield Lockshield / flow meter seat

Size:
for manifolds 1”
B for manifolds 1”1/4 D
24x19 and 3/4” Eurocone

Nickel-plated reduction
Nickel-plated blind plug
Size:
Size:
3/4” M x 3/8” F - 3/4” M x 1/2” F
1/2” M (*) - 3/4” M (*) - 1” M (*) - 1”1/4 M (*)
1” M x 3/8” F - 1” M x 1/2” F
3/4” F - 1” F
1” M x 3/4” F - 1”1/4 M x 1/2” F
24x19 F blind Monoblocco seal (*)
1”1/4 M x 1” F
(*) = with o-ring
With o-ring
Thread UNI EN ISO 228-1
Thread UNI EN ISO 228-1

Swivel nipple Nickel-plated nipple with O-Ring

Size: Size: 1” M x 1” M
1” M x 1” M - 1”1/4 M x 1”1/4 M 1”1/4 M x 1”1/4 M
1”1/4 M x 1” M (*) With o-ring
3/4” M x 3/4” M Thread UNI EN ISO 228-1
Thread UNI EN ISO 228-1
(*) reduction

Key for nipples CH 37 - 48 Insulating shells

Size:
1” - 1”1/4

In closed cell cross-linked polyethylene foam.


To be cut to size according to the number of manifold ways
to isolate.

21
Couple double metal holder Couple single plastic holder

Size: Size:
3/4” - 1” - 1”1/4 3/4” - 1” - 1”1/4

Couple double adjustable plastic holder Couple double metal holder


Size: Size:
3/4” - 1” (*) - 1”1/4 (**) 3/4” - 1” - 1”1/4

POS. A-A POS. B-B


B B
A A
POS. 3/4" 1" 1"1/4
A-A [mm] [mm] [mm]
A 39 39 44
B 62 66 76
30 mm

200 mm

26 mm

C 69 69 74
D 92 96 106
210 mm

210 mm
200 mm

30 mm 26 mm
POS. 3/4" 1" 1"1/4
B-B [mm] [mm] [mm]
C C A 39 39 44
D D B 62 66 76
C 65 65 70
For wall fixing
9,5 mm

8,2 mm

120 mm 30 mm 140 mm D 88 92 102


8,2 mm
18,2 mm

(*) When installing the cassette from 80 mm brick thickness to move the collars of
the brackets on the B-B references..
(**) Do not install in boxes for 80 mm brick thickness.

22
Expansion vessel kit for connection to Topway distribution manifold in Metalbox Plus

L
B
A
260

500
Complete with: Kit expansion vessel 10 liter can only be installed in boxes for
expansion vessel: 8, 10 litres; mounting plate with screws for partition of 120 mm. Width 260 mm x height 490 mm.
installation in metal box; copper pipe Ø18x1 prepared for con-
nection tap loading/unloading 1/2” diameter copper pipe Ø10x1
derivation with nut 3/8” for connection to expansion vessel;
monoblocco seal for copper pipe Ø18x1; shank 1/2” - 24x19
with O-Ring for connection to Topway manifold; gasket 3/8”.

Note:
Recommended number of ways of Topway 1“ manifolds: Recommended number of ways of Topway 1“1/4 manifolds:
- with 8-liter expansion vessel in Metalbox Plus for 80 and - with 8-liter or 10-liter expansion tank in Metalbox Plus for
120 mm partition 120 mm partition
- with 10-liter expansion tank in Metalbox Plus for 120 mm
partition

L N° A B B L N° A B B
[mm] ways [mm] [mm] [mm] [mm] ways [mm] [mm] [mm]
500 2 430 - - 500 2 430 - -
600 12 2 430 530 540 600 12 2 430 565 550
700 12 2 430 530 540 700 12 2 430 565 550
700 12 3 480 580 590 850 12 3 480 615 600
850 12 4 530 630 640 850 12 4 530 665 650
850 12 5 580 680 690 850 12 5 580 715 700
850 12 6 630 730 740 1000 12 6 630 735 720
1000 12 7 680 780 790 1000 12 7 680 815 800
1000 12 8 730 830 840 1000 12 8 730 865 850
1000 12 9 780 880 890 1200 12 9 780 915 900
1200 12 10 830 930 940 1200 12 10 830 965 950
1200 12 11 880 980 990 1200 12 11 880 1015 1000
1200 12 12 930 1030 1040 1200 12 12 930 1065 1050

1 With 1“ straight Progress kit 1 With 1“1/4 straight Progress kit


2 With Progress 1“ square kit 2 With Progress 1“1/4 square kit

23
Control T
electrothermic heads

1
2
J

8 9 5
3
4
6

The range Technical data


–  230 Vac, normally closed, plastic ring nut Normally closed models: the opening takes place with the
–  230 Vac, normally closed, metal ring nut power supply controlled by the thermostat.
–  24 Vac, normally closed, plastic ring nut Normally open models: the closure takes place with the
power supply controlled by the thermostat.
–  230 Vac, with auxiliary micro (1 A 250 Vac), normally closed,
Absorption: 3.45 VA (230 Vac) / 3 VA (24 Vac)
plastic ring nut
Protection: IP 40 (IP44 vertical position)
–  230 Vac, with auxiliary micro (1 A 250 Vac), normally closed, Cable length: 1 m
metal ring nut Auxiliary contact capacity: 1 A 250 Vac
–  24 Vac, with auxiliary micro (1 A 250 Vac), normally closed, Starting current: 0.25 A (mod.230 Vac) / 0.35 A (mod.24 Vac)
plastic ring nut Opening / closing time: 5-6 min.
–  230 Vac, normally open, plastic ring nut
–  24 Vac, normally open, plastic ring nut

Construction
A Polycarbonate case
2 Stainless steel spring
3 Indicator in PPA (35% FV)
4 Radial stop ring in steel
5 Polycarbonate shutter support
6 Polycarbonate base
7 M30x1.5 ring nut in PA 66 (50% FV) or in nickel-plated
brass UNI EN 12164 CW614N
8 PVC cable
9 1 A 250 V microswitch
J Wax expansion electrothermal actuator

24
Basic wiring box 6T
for electro-thermic heads

It is a device especially designed for the connection and con- Outputs


trol of electrothermic heads associated to circuits of low tem- • No. 6 independent outputs for the activation of normally
perature radiant heating systems or high and low temperature closed electrothermic heads
mixed systems (underfloor radiators). • Contact for low temperature zone circulator (230 Vac)
The system is integrated and is installed easily in the regu- • Free voltage contact for heat source activation
lation and distribution boxes of the underfloor boxes (Floor • Free voltage contact for remote alarm
Control Unit HE) and allows to manage the high temperature
zones (max 6 zones) and low temperature zones.
The basic wiing box 6T simplifies and optimizes the wiring and
connection of the electrothermic heads and relative thermo- Functions
stats; it turns a low temperature circulator on and off (with • Direct supply of the electrothermic heads (selectable at 230
dedicated relay) and activates the generator that powers the or 24 Vac).
system. It includes the safety thermostat for the deactivation • Jumper configuration of the electrothermic heads as high or
of the low temperature circulator and a remote alarm contact low temperature.
to signal the intervention of the safety thermostat. • Jumper configuration of the electrothermic heads to be as-
Each unit features on the back of the box a pre-drilled metal sociated to the thermostat/s.
strip to attach it inside the manifold cabinets with a depth of • Adjustable safety thermostat (30-60 °C) integrated in the
110 mm. board. When it switches, it opens the contact of the low tem-
perature circulator and (if set with jumper) the contact of the
heat source; it closes the remote alarm contact.
Inputs • Activation of low temperature circulator with or without de-
• Max. number of connectable thermostats: 6 lay (4 min.) compared to the activation of at least one low
• NTC probe (supplied) for the safety thermostat of the low temperature zones.
temperature zone: length of cable 1.5 m • Circulator anti-seizure function: every 24 h of inactivity of
the circulator, it will be activated for 15”.

25
Monoblocco and Three-pieces seals

Monoblocco seal 24x19 for copper pipe 3/4” Eurocone seal for copper pipe

Sizes: Ø 10 - Ø 12 - Ø 14 - Ø 15 - Ø 16 Sizes: Ø 12 - Ø 14 - Ø 15 - Ø 16

24x19 Standard seals for copper pipe

3
2

Size: Ø 18

1
Construction and Technical data
2 A Nut in nickel-plated brass UNI EN 12165 CW617N
2 B Adapter in brass UNI EN 12164 CW617N
3 C Ogive in peroxide EPDM

Maximum pressure: 10 bar


Maximum temperature: 120 °C

Maximum torque:
Construction and Technical data - Ø 12 mm = 35÷40 Nm (*) - 68÷80 Nm (**)
A Nut in nickel-plated brass UNI EN 12165 CW617N
B Metal components in brass UNI EN 12164 CW617N - Ø 14 mm = 35÷40 Nm (*) - 68÷80 Nm (**)
C O-Ring fitting in NBR - Ø 15 mm = 35÷40 Nm (*) - 68÷80 Nm (**)
- Ø 16 mm = 35÷40 Nm (*) - 68÷80 Nm (**)
Maximum pressure: 10 bar
(*) Annealed copper pipe
Maximum temperature: 100 °C
(**) Semi-hard copper pipe
Maximum torque:
- Ø 10 mm = 30÷35 Nm
- Ø 12 mm = 35÷40 Nm
- Ø 14 mm = 40÷45 Nm
- Ø 15 mm = 40÷45 Nm
- Ø 16 mm = 45÷50 Nm
- Ø 18 mm Standard seal = 50÷55 Nm
- Blind Monoblocco (plug) = 30÷35 Nm

26
Monoblocco seal 24x19 for multilayer pipe Monoblocco seal 3/4” Eurocone for multilayer pipe

Sizes: Sizes:
12x1,6 - 14x2 - 16x2 - 16x2,25 - 18x2 - 20x2 - 20x2,5 16x2 - 20x2
26x3 (*)
(*) thread M32x1,5

5
5
1
1 4
4 2
2 3
3

5 5
5 5

Construction and Technical data


A Nut in nickel-plated brass UNI EN 12165 CW617N
Construction and Technical data B Adapter in brass UNI EN 12164 CW614N
A Nut in nickel-plated brass UNI EN 12165 CW617N C Ring in PTFE
B Adapter in brass UNI EN 12164 CW614N 4 Serrated hose-clamp in brass UNI EN 12164 CW614N
C Ring in PTFE, dielectric 5 O-Ring seals in EPDM
4 Serrated hose-clamp in brass UNI EN 12164 CW614N
5 O-Ring seals in EPDM Maximum pressure: 10 bar
Maximum temperature: 100 °C
Maximum pressure: 10 bar
Maximum temperature: 100 °C Maximum torque:
- 16x2 mm = 30÷35 Nm
Maximum torque:
- 20x2 mm = 30÷35 Nm
- 12x1,6 mm = 30÷35 Nm
- 14x2 mm = 30÷35 Nm
- 16x2 mm = 30÷35 Nm
- 16x2,25 mm = 30÷35 Nm
- 18x2 mm = 30÷35 Nm
- 20x2 mm = 30÷35 Nm
- 20x2,5 mm = 30÷35 Nm
- 26x3 mm = 55÷60 Nm

27
Monoblocco seal 24x19 for plastic, PEX, PP pipe Monoblocco seal 3/4” Eurocone for plastic, PEX, PP pipe

Sizes:
12x1 - 12x2 - 15x1,7 - 16x1,5 - 16x2 - 16x2,2 - 17x2 - 20x2 - 25x2,3 (*) Sizes:
12x2 with O-ring
(*) Thread M32x1,5 16x2 with O-ring
17x2 with O-ring
20x2 with O-ring

3
3
1
4 1
4

2
2

Construction and Technical data


A Nut in nickel-plated brass UNI EN 12165 CW617N Construction and Technical data
B O-Ring seals in EPDM A Nut in nickel-plated brass UNI EN 12165 CW617N
C Adapter in brass UNI EN 12164 CW614N B O-Ring seals in EPDM
4 Serrated hose-clamp in brass C Adapter in brass UNI EN 12164 CW614N
UNI EN 12164 CW614N 4 Serrated hose-clamp in brass
UNI EN 12164 CW614N
Maximum pressure: 10 bar
Maximum temperature: 100 °C Maximum pressure: 10 bar
Maximum temperature: 100 °C
Maximum torque:
Maximum torque:
- 12x1 mm = 30÷35 Nm
- 12x2 mm con O-ring = 30÷35 Nm
- 12x2 mm = 30÷35 Nm
- 16x2 mm con O-ring = 30÷35 Nm
- 15x1,7 mm = 30÷35 Nm
- 17x2 mm con O-ring = 35÷40 Nm
- 16x1,5 mm = 30÷35 Nm
- 20x2 mm con O-ring = 35÷40 Nm
- 16x2 mm = 30÷35 Nm
- 16x2,2 mm = 30÷35 Nm
- 17x2 mm = 30÷35 Nm
- 20x2 mm = 30÷35 Nm
- 25x2,3 mm = 55÷60 Nm

28
Monoblocco seal 24x19 for plastic PB pipe Three-pieces 24x19 and 3/4” Eurocone for PEX, PERT and
Multilayer pipe

Size Ø 15 Sizes:
24x19: 12x2 - 14x2 - 17x2
When using Emmeti compression fittings for Polybutylene pipe, 3/4” EK: 12x2 - 14x2 - 17x2
please ansure you use the plastic pipe insert provided for by the
manufacturer of the pipe you are using..

2 5

1 1
4
3
5 2
4 3

4 5 5

Construction and Technical data Construction and Technical data


A Nut in nickel-plated brass UNI EN 12165 CW617N nichelato A Nut in nickel-plated brass UNI EN 12165 CW617N nickelato
B Collar in brass UNI EN 12164 CW614N B Adapter in brass UNI EN 12164 CW614N
C Serrated hose-clamp in brass C RIng in PTFE, dielectric
UNI EN 12164 CW614N 4 Serrated hose-clamp in brass
4 O-Ring seals in EPDM UNI EN 12164 CW614N
5 Adapter in brass UNI EN 12164 CW614N 5 O-Ring seals in EPDM

Maximum pressure: 10 bar Maximum pressure: 10 bar


Maximum temperature: 100 °C Maximum temperature: 100 °C

Maximum torque: Maximum torque:


Ø 15 mm = 30÷35 Nm - 12x2 mm = 30÷35 Nm
- 14x2 mm = 30÷35 Nm
- 17x2 mm = 30÷35 Nm

Female 24x19 - Male M32x1,5 fitting Straight Male 1/2 ”- Male M32x1.5 fitting

Sizes: Sizes:
24x19 - M32x1,5 1/2” - M32x1,5

Complete with O-Ring and adapter on Female side Complete with O-Ring

29
Accessories for Monoblocco

CH 27-30 open poligonaly key CH 38 key for Multilayer 26x3 Monoblocco seals

To be used for tightening Monobloc seals for multilayer pipe


26x3 on manifold outlets with 50 mm takeoffs.

CH 27-30 spanner for tightening takeoffs, until DN 18 pipes

30
Metalbox Plus
recessed zinc-coated metal cabinet, adjustable dept

Height 600 mm

Telescopic case
Door frame flush with the plaster
Telescopic base

Adjustable foot

L 500 L 600 L 700 L 850 L 1000 L 1200

Uses Accessory
Zinc-coated metal cassette with plastic frame and door, white Key lock
colour RAL 9010, for 120 mm brick thickness.
Suitable for flush mounting with adjustable depth.
It is supplied with a slotted screwdriver lock, height adjustable
feet from 0 to 100 mm and a rubble protection metal cover.
Frame and door fto fit flush with wall 3 mm..

31
Metalbox
recessed and external zinc-coated metal cabinet

Height 850 mm Height 700 mm

L 500 L 700 L 850 L 1000 L 1200

Recessed cabinet uses External cabinet uses


Zinc-coated metal cassette with plastic frame and door, white Zinc-coated metal cabinet with plastic cover and door,
colour RAL 9010, for 120 mm brick thickness. white colour RAL 9010.
Suitable for flush mounting with adjustable depth. External installation for surface mounting.
It is supplied with a slotted screwdriver lock, height adjustable It is supplied with a slotted screwdriver lock.
feet from 0 to 100 mm and a rubble protection metal cover.
Frame and door fto fit flush with wall 3 mm.

32
Dimensional data of Metalbox Plus recessed zinc-coated metal cabinet, adjustable depth
A
12 L 12 96 min 148 L 155 max
12

480
540
Altezza 600 mm
500
H600
700

Height 600 mm

Metalbox Plus from 80 to 120 Metalbox Plus from 80 to 120 Metalbox Plus from 80 to 120 mm Metalbox Plus from 80 to 120 mm
mm brick thickness (front view) mm brick thickness (side view) brick thickness (front body view brick thickness (side body view
+ frame + door) + frame + door)

Dimensional data of Metalbox zinc-coated metal cabinet external box

30 B 30 L 140
30
465

Altezza 700 mm
H700

Height 700 mm

Metalbox body for external Metalbox for external surface Metalbox for external surface
surface (front view) (front carter view + door) (side carter view + door)

Size H 600/H700/ H 600/H700/ H 600/H700/ H 600/H700/ H 600/H700/


H 600
[mm] H850 H850 H850 H850 H850
L 500 600 700 850 1000 1200
A 560 660 760 910 1060 1260
B 470 / 670 820 970 1170

Dimensional data of Metalbox recessed zinc-coated metal cabinet


A
12 L 12 110 L 168
12

690
740

Altezza 850 mm
700
H850
950

Height 850 mm

Metalbox from 120 mm Metalbox from 120 mm Metalbox from 120 mm brick thick- Metalbox from 120 mm brick thickness
brick thickness (front view) brick thickness (view side) ness (front body view + frame door) (side body view + frame + door)

Size H 600/H700/ H 600/H700/ H 600/H700/ H 600/H700/ H 600/H700/


H 600
[mm] H850 H850 H850 H850 H850
L 500 600 700 850 1000 1200
A 560 660 760 910 1060 1260
B 470 / 670 820 970 1170
33
Topway manifolds (all versions) + accessories - Dimensions in box
With Progress valves + thermometers

L M IN L MIN
B B
A A
500

50 50

480

200
200
H600

H700
700

Metalbox Plus H 600 (view from front)


Metalbox external surface H 700
L MIN (view from front)
B
A

50
200
700
H850
950

Metalbox H 850 (view from front)

Combined with 1” Topway manifolds in metal cabinet Combined with 1”1/4 Topway manifolds in metal cabinet

N° ways A [mm] B 1 [mm] B 2 [mm] L min [mm] N° ways A [mm] B 1 [mm] B 2 [mm] L min [mm]
2 172 270 280 500 2 182 316 300 500
3 222 320 330 500 3 232 366 350 600
4 272 370 380 500 4 282 416 400 600
5 322 420 430 500 5 332 466 450 700
6 372 470 480 600 6 382 516 500 700
7 422 520 530 600 7 432 566 550 850
8 472 570 580 700 8 482 616 600 850
9 522 620 630 700 9 532 666 650 850
10 572 670 680 850 10 582 716 700 1000
11 622 720 730 850 11 632 766 750 1000
12 672 770 780 1000 12 682 816 800 1000
Note: LMIN including dimensions of press fittings Note: LMIN including dimensions of press fittings
1 With straight Progress valve kit 1” with thermometers and con- 1 With straight Progress valve kit 1”1/4 with thermometers and connec-
nections tions
2 With square Progress valve kit 1” with thermometers and connec- 2 With square Progress valve kit 1”1/4 with thermometers and connec-
tions tions

34
With Progress valves + thermometers and by-pass terminal kit

L M IN L MIN
A A
500

480
50 50

200

200
H600

H700
700

Metalbox Plus H 600 (view from front)


Metalbox external surface H 700
L M IN (view from front)
A

50
200
700
H850
950

Metalbox H 850 (view from front)

Combined with 1” Topway manifolds in metal cabinet Combined with 1”1/4 Topway manifolds in metal cabinet

N° ways A 1 [mm] A 2 [mm] L min 1 [mm] L min 2 [mm] N° ways A 1 [mm] A 2 [mm] L min 1 [mm] L min 2 [mm]
2 357 367 500 500 2 415 395 600 500
3 407 417 500 500 3 465 445 600 600
4 457 467 600 600 4 515 495 700 600
5 507 517 600 600 5 565 545 850 700
6 557 567 700 700 6 615 595 850 700
7 607 617 700 700 7 665 645 850 850
8 657 667 850 850 8 715 695 850 850
9 707 717 850 850 9 765 745 1000 850
10 757 757 850 850 10 815 795 1000 850
11 807 817 1000 1000 11 865 845 1000 1000
12 857 867 1000 1000 12 915 895 1000 1000
Note: LMIN including dimensions of press fittings Note: LMIN including dimensions of press fittings
1 With straight Progress valve kit 1” with thermometers and con- 1 With straight Progress valve kit 1”1/4 with thermometers and con-
nections nections
2 With square Progress valve kit 1” with thermometers and connec- 2 With square Progress valve kit 1”1/4 with thermometers and connections
tions

35
Termobox
plastic box for manifolds

The range Construction


– L 310 ABS box
– L 460 PS shock-proof cover
Nylon PA 6 supports.
– L 610

Uses
Box for manifolds for built-in installation, suitable for hot
and cold water and for manifolds for floor systems up to 1”.
Runners are incorporated in the rear wall, appropriately
spaced, for the manifold supports. All side walls are equipped
with removable panels so that manifolds and pipes can be
easily adjusted. Supplied complete with plastic netting and
cover for protection during site work

36
Support kit for Topway manifolds in bars without mechanics

Size:
3/4” - 1”

Aluminum track for manifold supports,


complete with screws and plugs

Size:
400 mm
200 mm

Termobox with Topway manifolds: maximum number of ways

Termobox 1” A+C 3/4” A+C 3/4” A+C 1” B+C 3/4” B+C 3/4” B+C 1” A+B+C 3/4” +B+C 3/4” A+B+C
takeoff takeoff takeoff takeoff takeoff takeoff
50 mm 36 mm 50 mm 36 mm 50 mm 36 mm
310 x 310 2 ways 3 ways 4 ways - 2 ways 2 ways - - -
460 x 310 5 ways 6 ways 8 ways 4 ways 5 ways 6 ways 3 ways 4 ways 5 ways
610 x 310 8 ways 9 ways 12 ways 7 ways 8 ways 11 ways 6 ways 7 ways 9 ways

37
Notes

38
Notes

39
EMMETI S.p.A. Unipersonale Rev. 0_EMMETI_Data sheet_09.2022_IT/Creative Design Team_SR
9901028200001
Via Brigata Osoppo, 166 TO KNOW MORE
33074 Vigonovo frazione di Fontanafredda (PN) - Italia GO TO OUR SITE
Tel. 0434.567911 WWW.EMMETI.COM
Fax 0434.567901
www.emmeti.com
info@emmeti.com

Every care has been taken in the creation of this document.


No part of this document may be reproduced or disseminated without Emmeti Spa Unipersonale‘s express written consent.
The data contained in this publication may, for a found technical and / or commercial need,
undergo changes at any time and without notice.
Therefore Emmeti Spa Unipersonale is not responsible for any errors or inaccuracies contained therein. comfort delivered by

You might also like