Professional Documents
Culture Documents
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Wind Analysis Based on UBC 1997
INPUT DATA
Exposure category = 2 Exp. C
Importance category = 2 Hazardous
Basic wind speed V = 100 mph
Building height to eave he = 14 ft
Building height to ridge hr = 28 ft
Building length L = 150 ft
Building width B = 110 ft
DESIGN SUMMARY
Horizontal pressure = 43.88 psf ,for roof
= 40.73 psf ,for wall
Upward pressure = 23.63 psf
Total horizontal force on building length = 134.91 kips
Total horizontal force on building width = 65.15 kips
Total upward force = 389.83 kips
Overturning moment on building length = 2384.00 ft-kips
Overturning moment on building width = 959.94 ft-kips
ANALYSIS
Importance factor Iw = 1.15
Mean roof height h = 21.0 ft
Hgt-exp-gust factor Ce = 1.14 ,for roof
1.06 ,for wall
Stagnation pressure qs = 25.7 psf
Pressure coefficients Cq = 1.30 horizontal any direction (Method 2, Table 16-H)
= 0.70 upward
ELEMENT & COMPONENT LOADS
0.8 @ bottom )