WIND LOAD CALCULATION AS PER BNBC 2020 (ARCHED ROOF)

INPUT Enclosure Condition:


Length (Parallel to wind), L = 58 m INPUT
Length (Normal to wind), B = 46 m Prepared By : Ao = 324 Sq.m 1. Ao > 1.1Aoi False
Bay Spacing = 6.36 m Ag = 648 Sq.m 2. Ao > 0.37 m2 or Ao > 0.01Ag True
End Column Spacing = 5.72 m Aoi = 852 Sq.m 3. Aoi/Agi <=0.20 False
Building Location = Chattogram Agi = 100 Sq.m 4. Ao >=0.8Ag False
Wind Speed, V (m/sec) = 80 m/sec Ref. Table 6.2.8 Fully Enclosed Condition
Exposure Type = B
Rise 2.030
Span 22.380
r= 0.091
Condition = Roofs on Elevated Structure Kz qz(kN/m2)
Importance Category, I = II Ref. Table 6.2.9 22.85 1.19 3.97
Wind Directioally Factor, Kd = Main Wind Force Resisting System Ref. Table 6.2.12 18.55 1.14 3.79
Topographic Factor, Kzt = 1 Ref. Sec. 2.4.7.2 14.75 1.08 3.61
Cyclone Prone Regions = 2 Height, (m) 10.95 1.02 3.39
Importance Factor, I = 1 Ref. Table 6.2.9 7.15 0.93 3.09
Kd = 0.85 3.35 0.85 2.83
Velocity Pressure, qz (kN/m2) = 0.000613KzKztKdV2I Ref.Eqn. 6.2.17 0 0.85 2.83
Gust Effect Factor, G = 0.85 Ref. Sec. 2.4.8

OUTPUT
Windward Wall Windward Quartar Leeward Leeward Wall Side wall
Height (m) (Kn/m) Centre Half Quartar (Kn/m) (Kn/m)
Cp01 Cp02
22.85 12.62
18.55 11.85
14.75 11.07
WL1(+int) 10.95 10.11 -23.85 0.00 -21.51 -15.27 -14.15 -17.59
7.15 8.84
3.35 7.72
0 7.72
Perpendicular to ridge
22.85 21.71
18.55 20.94
14.75 20.15
WL1(-int) 10.95 19.19 -14.76 0.00 -12.42 -6.18 -5.06 -9.42
7.15 17.93
3.35 16.80
0 16.80
Roof Side wall
Height (m) Windward Wall Leeward Wall (Kn/m)
From To For CP01 For CP02
22.85 11.35 0 11.425 -23.85 -8.40
18.55 10.66 11.425 22.85 -23.85 -8.40
14.75 9.96 22.85 45.7 -15.27 -8.40
WL1(+int) 10.95 9.09 45.7 End -10.98 -8.40 -13.73 -19.56
7.15 7.95
3.35 6.94
0 6.94
Parallel to ridge
22.85 19.52 0 11.425 -14.76 3.18
18.55 18.83 11.425 22.85 -14.76 3.18
14.75 18.13 22.85 45.7 -6.18 3.18
WL1(-int) 10.95 17.26 45.7 End -3.18 3.18 -5.56 -10.47
7.15 16.12
3.35 15.11
0 15.11
p Calculation (kN/m2)
Perpendicular to ridge
p (+ve) = qGCp-qi(GCpi)

Windward Windward Quartar Centre Leeward Leeward Side wall


Wall Cp-01 Cp-02 Half Quartar Wall (Kn/m)

1.98 -3.75 0.00 -3.38 -2.40


1.86
1.74
1.59 -2.22 -3.08
1.39
1.21
1.21

p (-ve) = qGCp-qi(GCpi)
Windward Windward Quartar Centre Leeward Leeward Side wall
Wall Cp-01 Cp-02 Half Quartar Wall (Kn/m)
3.41 -2.32 0.00 -1.95 -0.97
3.29
3.17
3.02 -0.80 -1.65
2.82
2.64
2.64

Pressure (kN/m)
Windwar Windward Quartar Centre Leeward Leeward Side wall
Height (m)
d Wall Cp-01 Cp-02 Half Quartar Wall (Kn/m)
22.85 12.62 -23.85 0.00 -21.51 -15.27
18.55 11.85
14.75 11.07
10.95 10.11 -14.15 -17.59
7.15 8.84
3.35 7.72
0.00 7.72
22.85 21.71 -14.76 0.00 -12.42 -6.18
18.55 20.94
14.75 20.15
10.95 19.19 -5.06 -9.42
-5.06 -9.42
7.15 17.93
3.35 16.80
0.00 16.80

Windwar Roof Leeward Side wall


Height (m)
d Wall Wall (Kn/m)
From To For CP1 For CP2
22.85 11.35 0 11.425 -23.85 -8.40
18.55 10.66 11.425 22.85 -23.85 -8.40
14.75 9.96 22.85 45.7 -15.27 -8.40
10.95 9.09 45.7 End -10.98 -8.40 -13.73 -19.56
7.15 7.95
3.35 6.94
0.00 6.94
22.85 19.52 0 11.425 -14.76 0.68
18.55 18.83 11.425 22.85 -14.76 0.68
14.75 18.13 22.85 45.7 -6.18 0.68
10.95 17.26 45.7 End -1.89 0.68 -5.56 -10.47
7.15 16.12
3.35 15.11
0.00 15.11
culation (kN/m2)
Parallel to ridge
p (+ve) = qGCp-qi(GCpi)

Windward Roof Leeward Side wall


Wall Wall (Kn/m)
From To For CP1 For CP2

1.98 0 11.425 -3.75 -1.32


1.86 11.425 22.85 -3.75 -1.32
1.74 22.85 45.7 -2.40 -1.32
1.59 45.7 End -1.73 -1.32 -2.40 -3.08
1.39
1.21
1.21

p (-ve) = qGCp-qi(GCpi)
Windward Roof Leeward Side wall
Wall Wall (Kn/m)
From To For CP1 For CP2
3.41 0 11.425 -2.32 0.11
3.29 11.425 22.85 -2.32 0.11
3.17 22.85 45.7 -0.97 0.11
3.02 45.7 End -0.30 0.11 -0.97 -1.65
2.82
2.64
2.64

As per Code Minimum Wind Pressure = 0.5 kN/m2


Minimum Pressure (kN/m)
Height Windward Windward Quartar Centre Half Leeward Leeward Side wall
(m) Wall Cp-01 Cp-02 Quartar Wall (Kn/m)
22.85 3.18 -3.18 0 -3.18 -3.18
18.55 3.18
14.75 3.18
10.95 3.18 -3.18 -2.86
7.15 3.18
3.35 3.18
0.00 3.18
22.85 3.18 -3.18 0 -3.18 -3.18
18.55 3.18
14.75 3.18
10.95 3.18 -3.18 -2.86
-3.18 -2.86
7.15 3.18
3.35 3.18
0.00 3.18

Height Windward Roof Leeward Side wall


(m) Wall Wall (Kn/m)
From To For CP1 For CP2
22.85 2.86 0 11.425 -3.18 -3.18
18.55 2.86 11.425 22.85 -3.18 -3.18
14.75 2.86 22.85 45.7 -3.18 -3.18
10.95 2.86 45.7 End -3.18 -3.18 -2.86 -3.18
7.15 2.86
3.35 2.86
0.00 2.86
22.85 2.86 0 11.425 -3.18 3.18
18.55 2.86 11.425 22.85 -3.18 3.18
14.75 2.86 22.85 45.7 -3.18 3.18
10.95 2.86 45.7 End -3.18 3.18 -2.86 -3.18
7.15 2.86
3.35 2.86
0.00 2.86
Wall Pressure coefficients,Cp Roof Pressure Coefficients
Surface L/B Cp Use With
Windward Wall All Values 0.8 qz Condition
0 -0.5
1 -0.5 qh
Leeward Wall 2 -0.3
4 -0.2 Roofs on Elevated Structure
100 -0.2
Side Wall All Values -0.7 qh Roofs Springing From ground level
* When rise to span ratio is 0.2 <= r <= 0.3 alternate co
for the windward Quarter
Horizontal distance from
Normal to 0 to h/
ridge for <=0.5 h/2 to
Ɵ<100 and
Parallel to h to 2h
ridge for >2h
all Ɵ
0 to h/
>=1.0
>h/2

L/B h/L
1.26 0.394 WWW

0.80

L/B h/L
0.79 0.50 WWW
0.80

WWW
0.80
oof Pressure Coefficients, Cp, for use with qh
Cpe
Rise to Span Ratio,
r Windward Centre Leeward
Quarter Half Quarter

0 < r <= 0.2 -0.90 - 0.7 - r -0.50


0.2 < r <= 0.3* 1.5r - 0.3 - 0.7 - r -0.50
0.3 < r <= 0.6 2.75r - 0.7 - 0.7 - r -0.50
0 < r <= 0.6 1.4r - 0.7 - r -0.50
0.2 <= r <= 0.3 alternate coefficient given by (6r -2.1) shall also be used

Horizontal distance from Windward Edge Cp


0 to h/2 -0.9 -0.18
h/2 to h -0.9 -0.18
h to 2h -0.5 -0.18
>2h -0.3 -0.18
0 to h/2 -1.3 -0.18
>h/2 -0.7 -0.18

r= 0.091
Cp1(Perpendicular to Ridge) Ɵ<10 0

Windward Quartar Centre Leeward LWW SW


Cp-01 Cp-02 Half Quartar Roofs Springing From gr
-0.90 0.00 -0.79 -0.50 -0.45 -0.70

Cp1 (Parallel to Ridge)


0 to h/2 h/2 to h h to 2h >2h LWW SW
-0.90 -0.90 -0.50 -0.30 -0.50 -0.70
Cp2 (Parallel to Ridge)
0 to h/2 h/2 to h h to 2h >2h LWW SW
-0.18 -0.18 -0.18 -0.18 -0.50 -0.70
Quartar
Roofs on Elevated Structure -0.900