You are on page 1of 1

Technical specification

Gasketed Plate Heat Exchanger

Customer: Bergen Engines AS


Project ref: Bergen Engines standard article number
Line ref: B01052211.W
Model: T10-BFM Page: 1(1)
Date: 08.10.2021

Hot side Cold Side


Fluid: Oil SAE 40 Water
Density: kg/m³ 876,6 986,9
Specific heat capacity: kJ/(kg·K) 2,02 4,17
Thermal conductivity: W/(m·K) 0,124 0,642
Viscosity inlet: cP 23,1 0,569
Viscosity outlet: cP 35,0 0,532

Volume flow rate: m³/h 80,00 99,00


Inlet temperature: °C 76,4 47,6
Outlet temperature: °C 65,0 51,6
Pressure drop: kPa 63,7 20,5
Heat exchanged: kW 450,0
LMTD: K 20,9
Heat transfer coefficient: W/(m²·K) 620,6
Heat transfer area: m² 34,58
Relative directions of fluids: Countercurrent
Effective margin: % 15,4
Effective fouling resistance * 10000: m²·K/W 2,145

Connection positions and flow directions: S1->S2 S3->S4

Connections: S1,S2,S3,S4 Flange EN 1092-1 PN10 DN100 unlined


Number of passes: 1 1

Design pressure (MAWP): bar 10,0 10,0


Test pressure: bar 14,3 14,3
Design temperature max: °C 90,0 90,0
Design temperature min (MDMT): °C 0,0 0,0
Channel arrangement: 1*67 MNa 1*67 MWi

Pressure vessel approval: PED Article 4.3


Fluid danger group: No Danger No Danger
Has risky vapour pressure: No No

Number of plates: 135


Nominal A-dimension: mm 394
Extension capacity: 14 plates
Plate material/thickness: ALLOY 304/0,4 mm
Gasket material and attachment: NBRB ClipGrip™ NBRB ClipGrip™

Approx. outer dimensions (L x W x H) mm 1 010 x 480 x 1 050


Approx. weight, empty / operating: kg 397 / 479
Approx. weight, full of water: kg 484
Type of package: Skid base + box
Approx. packed weight: kg 451,1

The performance of the equipment is conditioned by the process media and process parameters being consistent with the provided customer data.

Data, specifications, and other kind of information of technological nature set out in this document and submitted by Alfa Laval to you (Proprietary
Information) are intellectual proprietary rights of Alfa Laval. The Proprietary Information shall remain the exclusive property of Alfa Laval and shall only
be used for the purpose of evaluating Alfa Laval's quotation. The Proprietary Informationmay not, without the written consent of Alfa Laval, be used or
copied, reproduced, transmitted or communicated or disclosed in any other way to a third party.

You might also like