Service Ras Tanura Plant NO. RTR-27 Service NO.
PUMP PUMP
Mfr. SAUDI MECHANICAL INDUSTRIES CO. Mfr.
Type: CENTRIFUGAL VERT. SUBMERSIBLE Model SK8LC-7 stages Type: Model
Mfr. Ser. No. Equip. No. Mfr. Ser. No. Equip. No.
Order No. 085-01499 Data Sheet No. Order No. Data Sheet No.
Drawings: Drawings:
Pres: Suction kPa(abs) Disch. kPa(abs) Pres: Suction kPa(abs) Disch. kPa(abs)
Mfr. Max. Pres. Rating kPa(ga) Mfr. Max. Pres. Rating kPa(ga)
L/s 32 (508 GPM) Speed 3500 RPM L/s Speed RPM
DESCRIPTION
Imp. Dia.: Install. 5.85 inch Max. 5.94 inch Imp. Dia.: Install. Max.
Inlet: Size 6 in. ASME Class kPa(ga) Facing Inlet: Size in. ASME Class kPa(ga) Facing
Outlet: Size 6 in. ASME Class 150 kPa(ga) Facing Outlet: Size in. ASME Class kPa(ga) Facing
Mat'l.: Case ASTM A743 CF3M Imp. ASTM A743 CF3M Mat'l.: Case Imp.
Mat'l.: Cyl. Piston Mat'l.: Cyl. Piston
Lining Lining
1050 psi or 7239 kPa for BOWL
Hydrotest kPa(ga) Shut Off Head 773 ft (235.6) m Hydrotest kPa(ga) Shut Off Head m
345 psi or 2379 kPa for COLUMN & HEAD (ACT. IMP. DIA.)
DRIVER DRIVER
Order No. Data Sheet No. Order No. Data Sheet No.
Drawings: Drawings:
MOTOR TURBINE MOTOR TURBINE
ATE
125 HP (1 SF)
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FU
DA
kW kW kW kW
Speed 3500 RPM Overspeed Set RPM Speed RPM Overspeed Set RPM
REV.
480
NO.
ENGINEER
Phase 3 Pres. Outlet kPa(ga) Phase Pres. Outlet kPa(ga)
Mat'l Case Mat'l Case
DATE:
Mat'l Rotor Mat'l Rotor
PROJECT
ENGINEER
OPERATING LIMITS
DATE:
(Consult Engineering before exceeding these limits)
CERTIFIED
Design Pres.1475 kPa (214 psi), 494 ft kPa(ga) 31 OC Design Pres. kPa(ga) OC
DATE:
Max. Safe Speed For Unit Max. Safe Speed For Unit
Test Pressure kPa(ga) Test Pressure kPa(ga)
OPERATION
DATE:
CONTROL NUMBER
VERIFICATION
SAFETY PRECAUTIONS
Note below any special hazards, recommendations, inspections, or tests that are important for the above equipment.
EDSD
DATE:
BY:
C) NO. ________________________________
EVISION CERTIFICATION
S INDICATES THAT REV. NO. ___________
PROVAL/CERTIFICATION REQUIREMENTS,
THIS DRAWING IS COVERED, FOR ALL
SAFETY INSTRUCTION SHEET - PUMPS DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
SIS
A E
BY D
THIS
OF T
RE
APP
(DCC
EDSD/2742-M-0800.XLS
Saudi Aramco 6880-ENG (09/2000)
PMT OPRNS
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
CONTINUOUS INTERMITTENT STAND BY FLOW 21 %
2. ATTENDED UNATTENDED
OF THE RATED CAPACITY
3. PUMP FUNCTION: .1 BOWL ASSEMBLY DIFF. HEAD Ft 729 494 442 346
4. PUMP OPERATING MODE: INDIVIDUALLY IN PARALLEL
.2 COLUMN AND HEAD LOSS Ft 0.64 8.85 12.1 16.47
1. LIQUID PUMPED: GROUND WATER TDS 3564 ppm .5 VEL. IN COLUMN Ft/s 1.25 5.68 6.25 7.38
620.1
304.5
10.4
5. LUBRICANT: WATER
HEAD ABOVE DATUM Ft 485
.1 SAUDI ARAMCO EQUIV.:
BOWL ASSEMBLY
DIFFERENTIAL HEAD Ft 494 6. LEVEL READING GAUGE VENDOR STOCK NONE
DATE
Ft
Ft
Ft
DISCH. ELEVATION C
CONSTRUCTION DATA
L Ft 1.15
0 F
NO.
Ft
REV
DRAWDOWN
Ft in
DATE: 210.64 .3 MINIMUM DIAMETER in 4.69 4.69
PROJECT
ENGINEER
PUMPING LEVEL
Ft 258.93 .4 IMPELLER EYE AREA sq in 8.39 8.39
.5 EYE ENTRANCE VELOCITY Ft/s 19.43 19.43
DATE:
MIN. SUBMERGENCE Ft 11.5 .6 PERIPHERAL EYE VEL. Ft/s 89.28 89.28
REQUIRED ABOVE
CERTIFIED CL OF FIRST STAGE
.7 PATTERN NUMBER NA NA
.8 NUMBER OF VANES 5 5
.9 IMPELLERS: SEMI ENCLOSED CLOSED
DATE:
CONSTRUCTION
CASING DRIFT DIA in 18 .10 IMPELLERS: COLLET FITTED KEY FITTED
AGENCY 2. BOWL ASSEMBLY: THREADED BOLTED
3. PRESSURES MAX. ALLOW. HYDRASTATIC
PERFORMANCE DATA
DATE: .1 (M.A.W.P. AT 100 OF)
WORKING PR. TEST PRESS.
OPERATION D PUMP CHARACTERISTICS .1 BOWL ASSEMBLY psig 700 1050 MIN.
ASME
3. RATIO: END CURVE FLOW/RATED FLOW 1.28 SIZE
CLASS
FACING
4. RATIO: SHUT OFF HD/RATED FLOW 1.52
EDSD
ASME
APPROVAL/CERTIFICATION REQUIREMENTS,
SIZE FACING
9. PERM. OPER. TIME AGAINST CLOSED VALVE s 10 (PUMP TO RISER COLUMN) CLASS
OF THIS DRAWING IS COVERED, FOR ALL
EDSD/6880-1-0900.XLS
Saudi Aramco 6880-ENG (07/2000)
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
1. SURFACE PLATE FLANGE 25 in 1.25 in 22.75 in 1. CHECK VALVE IN COLUMN PIPE:
.1 BOLTING NUMBER / SIZE 16 / 1‐1/8 in YES: AT ELEVATION 20 FEET ABOVE BOWL ASSY. Ft NO
2. ELBOW DISCHARGE FLANGE SIZE RATING FACING 2. GAS SEPARATOR YES NO
6 in CLASS 150 3. SHOP INSPECTION AND VERIFIED TESTS
3. RISER COLUMN TOP CONNECTION VENDORS STANDARD SHOP TESTS REQUIRED
FLANGED 6 in CLASS 150 AS FOLLOWS
THREADED in ASME B2.1 TAPERED
SIZE POWER CABLE OPENING in CERTIF. WITN'D
.1 HYDROTEST - BOWLS
H MATERIALS OF CONSTRUCTION - SURFACE PLATE ASSY
1.1 BOWLS ASTM A743 CF3M .2 PERFORMANCE TEST
1.2 IMPELLERS ASTM A743 CF3M .3 RUNNING TEST MOTOR (1 HR)
1.3 SHAFT BOWL ASSEMBLY ASTM A276 / A479 XM19 .4 DISMANTLING
1.4 BEARINGS, BOWL ASSEMBLY ASTM D4745 TYPE 8 .5 HIGH POT. TEST MOTOR WINDINGS
DESCRIPTION
1.5 BOLTING STUDS ASTM A276, XM19 .6 HIGH POT. TEST CABLES SPLICES
NUTS ASTM A276, XM19 .7 DYNAMIC BALANCE IMPELLER
1.6 LOCK COLLETS TYPE 316 S.S.
1.7 COUPLING ASTM A276 / A479 XM19 4. DRAWING AND OTHER DATA
1.8 MOTOR HOUSING MOTOR: CF8M, SS316 MANUFACTURER'S DRAWING OR DOCUMENT NO.:
YES NO
UTILITY DATA .1 DIMENSIONAL DRAWING OF
COMPL'Y ASSEMBLED UNIT
J UTILITIES
.2 OPER. & MAINT. INSTRUCTIONS
1. MAIN POWER SUPPLY
.3 CROSS SECT. DWG. WITH PART NO'S.
3 PHASED / 60 CYCLE / 480 VOLTS
.4 BILLS OF MATERIALS
2. CONTROL & PROTECTION
.5 COMPL'D PUMP DATA SHEET
3 PHASE / 60 CYECLE / VOLTS
.6 CERT'D TEST CURVE & DATA
SUBMERSIBLE MOTOR / CABLE DATA .7 RECOMM'D SPARE PARTS LIST
.8 INSTRUMENT WIRING DIAGRAM
K MOTOR DATA .9 MECHANICAL SEAL DWG.
1. SPEED AT FULL LOAD RPM 3500
JO/EWO
7. MINIMUM BREAKDOWN TORQUE lb. ft 198 .2 COPPER ANODE FOULING PREVENTION SYSTEM YES NO
DISCIPLINE
ENGINEER
8. EFFICIENCY AT FULL LOAD % 85
9. POWER FACTOR AT FULL LOAD 0.86 BUYERS REFERENCES
DATE:
10. CURRENT AT FULL LOAD A 160
11. WINDING TO BE BRACED FOR FULL VOLTAGE
PUMPS OF SAME TYPE & SIZE IN OPERATION
PROJECT
ENGINEER START WITH A RESIDUAL VOLTAGE OF PUMPS MARK NO. INQ. / ORDER NO. DATA SHEET NO.
MANUFACTURER STANDARD
L CABLE DATA
VERIFICATION
3. CONDUCTORS EACH
BY:
4. LENGTH Ft 380
5. DIAMETER, OD in 10.6 mm (0.417)
REVISION CERTIFICATION
APPROVAL/CERTIFICATION REQUIREMENTS,
EDSD/6880-2-0700.X.S