2. CHANGE IN DIRECTIONS A B C A B C
ALL CHANGES IN DIRECTION SHALL BE MADE BY THE APPROPRIATE USE OF
7600 7600
FOURTY FIVE DEGREES (45°) WYE LONG SWEEP QUARTER BEND SIX EIGHT OR
4500 3100
SIXTEENTH BENDS WHEN THE CHANGE OF FLOW IS HORIZONTAL OR TO 4500 3100
1
VERTICAL. A SINGLE WYE
8 BEND COMBINATION MAYBE USED ON WASTE LINES
TEES AND CROSSES MAYBE USE ON VENT PIPES.
SEPTIC TANK 100mmØ PVCSP DN SERVICE AREA / LAUNDRY DN SERVICE AREA / LAUNDRY
3. PROHIBITTED FITTINGS 100mmØ PVCWP
2% SLOPE
100mmØ PVCSP CB CB
NO DOUBLE OR DOUBLE TEE BRANCH SHALL BE USED ON HORIZONTAL SOIL OR 200mmØ PVCWP
3
50mmØ PVCSP
WASTE LINES. THE DRILLING AND TAPPING OF HOUSE DRAINS. WASTE OR VENT
PIPES AND USE OF SADDLE HUB AND BENDS ARE PROHIBITTED. WC
50mmØ PVCSP
50mmØ PVCSP
3 200mmØ PVCWP
DS
2% SLOPE
100mmØ PVCSP
FD
3000
3000
4. SLEEVES CO LAV
PROVIDE PIPE SLEEVES AT WALLS, COLUMNS OR SLAB ONE SIZE BIGGER THAN
THE ACTUAL SIZE PASSING THROUGH WALL OR UNDER SLAB TO PROTECT PIPE
2 2
6000
6000
FROM BREAKAGE.
5. CLEAN OUT PIPE 200mmØ PVCWP
3000
3000
a.) EVERY PIPE IN HORIZONTAL DIRECTION EXCEEDING TWENTY TWO AND ONE
HALF DEGREES (22 1/2°). CANOPY CANOPY
b.) ONE AND ONE HALF METERS (1.50M) INSIDE THE PROPERTY LINE BEFORE THE
HOUSE DRAINAGE CONNECTION. 1 1
2% SLOPE
DS
OVERHANG CANOPY CANOPY OVERHANG CANOPY CANOPY
UP UP
6. SEPTIC VAULT SHALL NOT BE CONSTRUCTED UNDER THE BUILDING.
TO SEWER LINE
8. NO LESS THAN 300mm. OF AIR SPACE MUST LEFT BETWEEN THE TOP OF THE
SEWAGE AND THE UNDERPART OF THE VAULT ROOF SLAB.
10. ALL PLUMBING WORKS SHALL BE DONE BY A LICENSED MASTER PLUMBER AND A
LICENSED PLUMBING CONTRACTOR.
R.A. 9266
SECTION 20