GENERAL NOTES:

A. IN THE INTERPRETATION OF THESE DRAWINGS INDICATED DIMENSIONS SHALL GOVERN & DISTANCES OR SIZES
SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. Mark C-1 C-2
B. BARS OF REINFORCED CONCRETE MEMBER EXPOSED TO THE WEATHER SHALL BE PROTECTED WITH AT LEAST
10MMØ @ 300mm O.C.
3.81cm (1-1/2") AND IN NO CASE LESS THAN 2.54cm (1") CONCRETE. THESE CONDITIONS MAY BE WAIVED FRAME BARS
WHEN ADEQUATE WATERPROOFING IS PROVIDED.
C. REINFORCING BARS; UNLESS OTHERWISE SPECIFIED ON PLANS, ALL REINFORCING BARS SHALL BE DEFORMED 16Ø @ 150 CONT.
BOTTOM BARS
WITH A MINIMUM YIELD STRENGTH OF 414 MPA (60,000 PSI) FOR BARS 12MM DIA. AND ABOVE AND . Section
275 MPA (40,000 PSI) FOR 10MM DIA. AND BELOW.
ALL REINFORCING BARS SHALL BE CLEANED OF RUST, GREASE OR OTHER MATERIALS WHICH TEND TO IMPARE BOND. 16Ø @ 150 EXTRA
TOP BARS
IF WELDING IS REQUIRED, DEFORMED BAR SHALL CONFORM TO ASTM A-706 LOW ALLOY GRADE FINISH FLOOR LEVEL

D. ALL CONCRETE WORKS SHALL BE DONE IN ACCORDANCE WITH THE ACI-318-08 BUILDING CODE FOR REINFORCED 12MMØ @ 150mm O.C.
12MMØ @ 150mm O.C.
CONCRETE & ALL STRUCTURAL STEEL WORKS SHALL BE DONE IN ACCORDANCE WITH AISC SPECIFICATIONS 2005 FOR, Covering 40mm 40mm TEMP. BARS
TEMP. BARS

AS DO NOT CONFLICT WITH LOCAL BUILDING CODE REQUIREMENTS. 12MMØ @ NOSING BARS

E. SLAB ON FILL MUST NOT BE PLACED UNLESS FILL HAS BEEN PROPERLY COMPACTED. ALL SLAB ON FILL SHALL Size 300mm x 250mm 250mm x 250mm 16MMØ @ 150mm O.C.
16Ø @ 150MM O.C. BARS EXTRA TOP BARS
BE PROVIDED WITH 100mm EXCEPT ON DRIVEWAY, 150mm WELL COMPACTED CLEAN COARSE SAND BED. BACK
FILLING OF ALL EXCAVATED AREAS AND THE PREPARATION OF SUB-BASE SHALL BE WELL COMPACTED AT LEAST
Main Rebars 6- 16Ømm 4- 16Ømm 16MMØ @ 150mm O.C.
CONT. BOT. BARS
12Ø BARS @ 200 MM O.C.
95% OF THE STANDARD PROCTOR DENSITY BEFORE WELL COMPACTED 100MM CLEAN COARSE SAND ARE LAID.
F. CONTRACTOR SHALL COORDINATE WITH THE AR, ME, SE, & EE PLAN AS TO THE EXACT SIZES & LOCATION OF FILL COMPACTED @ 95% MDD
10mmØ RSB spcd: 10mmØ RSB spcd:
HOLES THRU FLOOR SLABS AND WALLS. 6@50mm, 4@100mm, 6@50mm, 4@100mm, FLOORING CONNECTION DETAILS BEAM CONNECTION DETAILS
Ties 4, 150mm, Rest @ 4, 150mm, Rest @ 3 STAIR DETAIL 2 4 STAIR DETAIL 3
G. FOR COLUMNS EMBEDDED TO SOIL, ADDITIONAL 40mm CONCRETE COVER SHALL IMPOSED.
200mm O.C 200mm O.C
NOTES ON CONCRETE MIXES & PLACING: S 2 SCALE 1:75 S 2 SCALE 1:75
A. UNLESS OTHERWISE INDICATED IN PLANS OR NOTED IN THE STRUCTURAL SPECIFICATIONS, THE MINIMUM 28
DAYS COMPRESSIVE CYLINDER STRENGTH OF CONCRETE SHALL BE AS FOLLOWS :
200 200
PROJECT EL SUKKAH (MIN) (MIN)
1.) FOR FOOTINGS ----------- 24 MPa (3,500psi) 1 2-12mmØ
2.) FOR COLUMNS ----------- 24 MPa (3,500psi) COLUMN DETAILS HORIZONTAL
BARS
3.) FOR BEAMS, GIRDERS & SLABS ----------- 24 MPa (3,500psi)
4.) FOR OTHER STRUCTURAL ELEMENTS ----------- 24 MPa (3,500psi)
S 2 SCALE 1:20

B. 1.) CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSITION WITHOUT SEGREGATION, REHANDLING OR FLOWING.
10mmØ STIRRUPS at
PLACING SHALL BE DONE PREFERABLY WITH BUGGIES, BUCKETS OR WHEEL-BORROWS. NO CHUTES SHALL 150mm O.C.
EXCEED SIX(6) METERS AGGREGATE LENGTH.
1-12mmØ VERTICAL
2.) NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF VIBRATORS UNLESS AUTHORIZED BARS TYPICAL

BY THE DESIGNER IN WRITING.


OPENING
C. MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS FOLLOWS:

16MMØ @ 150mm O.C.


1.) SUSPENDED SLABS ------------------------------------- 3/4 IN. ( 19 MM. ) CONT. BOT. BARS
12MMØ @ 300mm ON
2.) SLAB ON GRADE --------------------------------------- 1 1/2 IN. ( 38 MM. ) 16MMØ @ 150mm O.C. PROJECT EL SUKKAH
CENTER FRAME BARS
CONT. TOP. BARS
3.) WALLS ABOVE GRADE ------------------------------------ 1 IN. ( 25 MM. )
12MMØ @ 150mm
7 TYP. FLOORING DETAILS
16MMØ @ 150mm O.C.
4.) BEAM STIRRUPS AND COLUMN TIES -------------------- 1 1/2 IN. ( 38 MM. ) ON CENTER TEMP. BARS TEMP. BARS
5.) WHERE CONCRETE IS DEPOSITED S 2 SCALE 1:100
DIRECTLY AGAINST EARTH 3 IN. ----------------------- ( 75 MM. ) 2-20mmØ CUT BARS
PROJECT EL SUKKAH
NOTES ON FOUNDATION 16MMØ @ 150mm ON CENTER
2-20mmØ CUT BARS 8 TYP. LINTEL BEAM DETAILS
A. ALL FOOTINGS WERE DESIGNED BASED ON THE ASSUMED ALLOWABLE SOIL BEARING CAPACITY OF 90 KPA EXTRA TOP BARS
4-25mmØ TOP BARS
16MMØ @ 150mm ON CENTER S 2 SCALE 1:30
THE OWNER SHALL REPORT IN WRITING THE DESIGNER THE ACTUAL SOIL CONDITION BASED OR CONT. BOT. BARS 4-25mmØ BOTTOM BARS
BASED ON THE GEOTECHNICAL REPORT CONDUCTED BY GEOTECHNICAL ENGINEER. SEC 10mmØ STIRRUPS SPACED 6
at 50mm, 4 at 100mm, 4 SEC
B. USE 414Mpa (60,000 PSI) FOR FOOTING REINFORCING BARS. @150mm, REST at 120mm

REINFORCED CONCRETE
C. NO FOOTING SHALL REST ON UNCOMPACTED FILL NOR LOOSE SOIL. PROVIDE 100MM THK. LEAN CONCRETE BEAM ( SEE SCHED. BS-1 )
BETWEEN THE FOOTINGS AND EXISTING SOIL. THE MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT
SHALL BE 75mm CLEAR.
LANDING CONNECTION DETAILS COLUMN COLUMN
D. ALL COLUMN REINFORCEMENT SHALL REST ABOVE THE BOTTOM REINFORCEMENTS OF THE FOOTING 2
WITH 90-DEGREE BEND PLUS 12 TIMES BAR DIAMETER EXTENSION AT THE FREE END BUT NOT LESS
STAIR DETAIL 1
PROJECT EL SUKKAH
THAN 300MM. HOOPS IN THE COLUMN SHALL CONTINUE BELOW THE THE FOOTING AT 0.10m OC. S 2 SCALE 1:75 9 TYP. STRUC. BEAM DETAILS
E. NO FOOTING SHALL REST ON FILL. FOOTINGS FOR CHB WALLS AND OTHER MINOR STRUCTURES SHALL L/4 L/2 L/4
S 2 SCALE 1:30
BE EMBEDDED AT LEAST 750mm FROM THE NATURAL GRADE LEVEL, L (CLEAR SPAN)

F. PROVIDE TEMPORARY REMOVAL OF WATER FROM ANY SOURCE DURING CONSTRUCTION. DEWATERING
SHALL BE CAREFULLY AND PROPERLY PERFORMED TO AVOID DISTURBING THE FOUNDATIONS AND
SLAB BEARING SURFACES.
70 70 70 70 SEE CONSTRUCTION
G. CONTRACTOR SHALL DESIGN, INSTALL AND MONITOR EXCAVATIONS RETENTION SYSTEMS, AS REQUIRED FOR
D ET AI L S F O R M AS O N RY
PROTECTION OF ADJACENT PROPERTIES AND PROVIDE ALL MEASURES AND PRECAUTIONS NECESSARY TO WALL REINF ORCEM ENTS
MINIMIZE SETTLEMENT AND PREVENT DAMAGE TO ADJACENT EXISTING OR NEW CONSTRUCTION. 12mmØ VERTICAL BAR at
( T Y P I C A L )
600mm O.C. AND 10mmØ
H. PREPARE CONDITIONS OF CONCRETE SUPPLY AND PLACEMENT OF THE 3 - 1 0 m m Ø HORIZONTAL BAR at EVERY 12mmØ VERTICAL BAR at
300

TEMPERATURE BARS

300
COMPLETE FOUNDATION FOR THE FULL THICKNESS AS A CONTINUOUS MONOLITHIC CASTING. 3 LAYERS OF CHB 3 - 1 0 m m Ø 12mmØ DOWELS 600mm O.C. AND 10mmØ
STRUCTURAL STEEL NOTES: TEMPERATURE BARS HORIZONTAL BAR at EVERY
12mmØ VERTICAL BAR at 3 LAYERS OF CHB
1. ALL STRUCTURAL STEEL SHAPES AND PLATES SHALL CONFORM 600mm O.C. AND 10mmØ 12mmØ DOWEL 1 2 m m Ø V ER TI C AL B AR a t
60 0mm O.C. AND 10mmØ
300

3-12mmØ C ONTI NOUS

300
TO ASTM A-36. HORIZONTAL BAR at EVERY
3 LAYERS OF CHB 3-12mmØ TEMPERATURE HORIZONTAL BAR at EVERY 3 BARS with 10mmØ CROSS
2. LIGHT-GAUGE COLD-FORMED STRUCTURAL STEEL SHALL BARS with 12mmØ CROSS L A Y E R S O F C H B BARS SPACED at 300mm
1 0 0 m m TH K . CH B W AL L BARS SPACED at 300mm O N C E N T E R S
CONFORM TO PERTINENT SPECIFICATIONS OF THE AMERICAN 100mm THK. CHB WALL
300

FILL OUT CHB GAP/JOINT

300
O N C E N T E R S
IRON AND STEEL INSTITUTE (AISI). BY MORTAR AND WASH IT FILL OUT CHB GAP/JOINT BY

200
3. MACHINE BOLTS SHALL CONFORM TO ASTM A-307. EACH BOLT OUT USING PAINT ROLLER MORTAR AND WASH IT OUT
50mmØ THK. SAND USING PAINT ROLLER
SHALL BE PROVIDED WITH STANDARD NUTS AND WASHERS. 12mm Ø HALF TIES B E D D I N G
300

50mmØ THK. SAND

300
F O O T I N G 1 0 0 m m Ø T H K . 12mm Ø HALF TIES FOOTING B E D D I N G
4. ANCHOR BOLTS SHALL CONFORM TO ASTM A-141.
REBARS AT 250mm O.C. 3/4"COMPACTED GRAVEL REBARS AT 250mm O.C. 1 0 0 m m Ø T H K .
5. CROSS BRACING WITH TURNBUCKLES SHALL CONFORM TO S P A C I N G S P A C I N G 3/4"COMPACTED
EARTH-FILL EARTH-FILL
ASTM A-307. G R A V E L
6. WELDING ELECTRODES SHALL CONFORM TO AWS A-51 OR A-5.5;
E 70 ELECTRODES.

PROJECT EL SUKKAH PROJECT EL SUKKAH


6 STRUCTURAL GENERAL NOTES 5 WALL FOOTING PLAN AN DETAILS
S 2 SCALE N.T.S. S 2 SCALE 1:20

DESIGN BY: IMPORTANT: NOTE: PROJECT TITLE: OWNER/APPROVED BY: SHEET CONTENT: SHEET NO.:

DRAWN BY:
ENGR.JOMARI C. BALOD
CIVIL ENGINEER
DATE:

CHECKED BY:
This drawing and related information have been prepared for a specific
purpose and may not be used for any purpose other than the purpose
intended. The design team does not provide any warranties and
All measurements must be verified at the site
before construction. Contractors shall notify the
Architect/Designer of any discrepancy before P R O J E C T E L S U K K A H S201
accepts no liability arising out of the use of this drawings or any of the commencement of work, Architect/Designer Shall
PRC NO. : VALID UNTIL : DATE: OF:
related information for any purpose other than the intended purpose. not be held responsible for any errors should the P R O P O S E D T W O - S T O R E Y R E S I D E N T I A L B U I L D I N G
REGISTRATION DATE: PTR NO. : PROJECT NO.: This drawing is protected is protected by copyright and no part of this contractor fail to observe this procedure. The

VALID UNTIL:

TIN NO. :
DATE ISSUED : REVISION:

STATUS:
drawing may be reproduced in any form without the express written
permission of the undersigned.
contractor shall be responsible for any errors
resulting from failure to do so.
LOCATION: ANNAFUNAN WEST, TUGUEGARAO CITY, CAGAYAN
MR.AND MRS.VICENTE J.SANTIAS JR.