You are on page 1of 1

keyword

150 KW Gas Generator

Ratings *Ratings at 0.8 power factor Performance


Data * The above fuel consumption is calculate
with the natural gas whose heat value is
35.8MJ/Nm 3 Dimensions and Weights Engine
Brand & Model: HGNT14 Engine Data How to
check coolant proportion: WARNING: Don't take
off the radiator cover...

Send Inquiry

Product Details

KDGH150-NG 50HZ

Ratings

kVA 188

kW 150

50Hz, 380/220V, 3 phases and


Voltage type
4 wires

*Ratings at 0.8 power factor

Performance Data

Engine Brand & Model

Alternator Brand & Model LS

Control System D

Standard Noise Level@7m (Soundproof Sets)

Circuit Breaker Type

Frequency & Phase 50h

Engine Speed (RPM)

3
Fuel Consumption (Nm /hr) 100% Load

* The above fuel consumption is calculate with the natural


3
gas whose heat value is 35.8MJ/Nm

Dimensions and Weights

Content Open type

L 2900

Dimensions: (mm) W 950

H 1550

Weights (kg) 2000

Engine Brand & Model: HGT6L

Engine Data

No. of Cylinders 6 Engine powe

Cycle 4 Stroke Cylinder T

Bore * Stroke
114 * 135 Compression
(mm)

Turbocharged and
Induction Displaceme
Aftercooled

Cooling Method Water cooled Governing

Coolant cap
Starting method 24V DC motor
including radi

15W40-CF4 or
Lubricant Oil Oil pan capa
above grade

Inspection in operating:

² When the generator set is on the normal working hours,


gas engine water temperature and oil temperature is not
more than 95℃, oil pressure should be in the range of 0.25-
0.35 Mpa. Pay attention to these changes when the
generator set is on working. When the data excess the
value, a part of load should be unload or stop generator set
for inspection.

² Be ready to check the pipeline of gas engine, such as


leakage, which should be repaired promptly.

² Observe the gas engine exhaust gas color. When gas


engine running at full capacity under normal circumstances,
the exhaust fumosoroseus have slightly green gray.

² Water, oil or metal objects are not allowed access to


internal generator set.

² If the generator set have unusual phenomenon and need


to power off or shut down immediately, pull
the “emergency stop” button or “hand-stopping” button.
² In the process of operation, it is need to record the
measurement readings, the ambient temperature, operation
time and downtime, the reason of stop as well as result of
inspection and repair, etc.
Frequent malfunction and disposal measures:
Please stop the generator quickly once encounter the
problem as follows during the running, increased and
reduced the power load. (Turn off the key, cut the gas
supply and iginition power supply)
1. Oil pressure lower than 0.15 Mpa
2. Water temperature higher than 90℃
3. Frequency continuously exceed 30 seconds and higher
than 52Hz
4. Battery voltage lower than 24V.
Problem Processing Method:
1. Check the oil level to see if it needs filling
2. Check the water tank to see if it is enough
3. Check the load increased and decreased whether
according to the requirement of generator
4. Battery should be charged for 24 hours, if it can’t reach
24V, it should be cahnged.

If the generator set can’t start normally, please check


the items as follows:

u Whether electric-key start too long (over than 15 seconds)


but not pressing the start button

u Check if the gas connecting joint connects closely

u Check if the outside circuit connecting is liable

u Check if the battery voltage is normal

u Check if the high voltage winding is damaged and


connected normally

u Check if the gas pipe explosion-proof is closed

u Check if the mixer and electronic speed governor actuator


connecting is liable

Problem Processing Method:


u Cut off the battery power supply and connect it again
u Reset the protection device
u Charging or replace the battery

Hot Tags: 150 KW gas Generator, China, suppliers,


manufacturers, factory

Previous: 120 KW Gas Generator

Next: 200 KW Gas Generator

Inquiry

E-mail

Tel

Please enter the content!

Send

You Might Also Like

Yuchai Powered Diesel Synchronization Panel


Generator

120 KW Biogas Generator 50 KW Gas Generator

80 KW Biogas Generator 150 KVA Standby Diesel


Generator

Tangchun Industrial Zone, Liaobu Town,


Dongguan City, Guangdong Province, P.R.China

+86-769-88996313

sf@camda.cc

http://m.camda-generator.com/

About Us Product News Project Contact Us Feedback SiteMap

Copyright © Camda New Energy Equipment Co.,Ltd All Rights Reserved.

You might also like