Work Order Number Site Name Print Date WO Due Date

C0368-EI-2502-504-1-MW1-A CHALK RIVER Apr 6, 2022

Project Name : 2502-504 Yr-2022 EORN IPRAN Transport Upgrades

Revision Reason :

Project Description

Scope of Work Order


Installation of new radio system: Multi-Band ML6363_ML6692 8GHz 4DE_4x296Mbps (4+4) SD with 2 XPICs
(MW - Transmission) HW Upgrade

Location: C0368 CHALK RIVER facing C0414 PEMBROKE

**** Service Affecting/Threatening: NO ****

Pre-Requisites Work Orders

Work Order Number Description


This IWO will cover 5G BB Addition, AIR3258 for 3.5GHz & R4415 for 2600MHz
(Scope of Work: SP, Civil and Ericsson)

- Install Rectifier Module (***Electrician may be required***)


- Install Battery Strings
- Add AIR3258 for 3.5GHz
C0368-EI-2907-507-1-BT1-A
- Add R4415 for 2600MHz & breakers
- Install DC-DC Up Converter & breaker
- Install 50A voltage booster fuses for 3.5GHz
- Install BB6648 (3.5GHz) & breaker
- Install 10G SFP (SFP-10G-LR-S=) to Cisco Switch
- Reuse reserved power & fiber ports
Installation of new radio system: Multi-Band ML6363_ML6692 8GHz
4DE_4x296Mbps (4+4) SD with 2 XPICs (MW - Transmission) HW Upgrade
C0414-EI-2502-504-1-MW1-A
Location: C0414 PEMBROKE facing C0368 CHALK RIVER

**** Service Affecting/Threatening: NO ****

Roles Work Orders Distribution List :

Approver Zeeshan Gul 6472825961 alex.chiu

Designer Ian Correa 6474774401 lee.conway

Distributor Zeeshan Gul 6472825961 NI GTA TX

NI TX ON

sonia.furtado

Page 1 of 74 C0368-EI-2502-504-1-MW1-A
Work Order - Instructions Work Order Number C0368-EI-2502-504-1-MW1-A

No Location Code Site Name Action


1
1 C0368 CHALK RIVER Install/Connect

***Where applicable Refer to Floor Plan, Rack Elevation Views, Connections Spreadsheets, EERF, Transmission Design, FCD, SAR, Map, Drawing and any
other documents attached to the work order***

INSTALL & CONNECT:


--------------
- ML6363_ML6692 8GHz 4DE_4x296Mbps (4+4) SD with XPICs facing C0414 Radio System
- 1x NPU 1005 Card
- 4x MMU-1002
- 1x SM8TAT2SA-DC Switch
- 1x LTU 1001 Card & T1 Cables
- 1x 10G SPF
- Breakers
**FUNCTIONAL CROSS-CONNECTIONS WILL BE DONE INSIDE THE PROVISIONING PWO**

Page 2 of 74 C0368-EI-2502-504-1-MW1-A
Work Order - Instructions Work Order Number C0368-EI-2502-504-1-MW1-A

No Location Code Site Name Action


2
2 C0368 CHALK RIVER Notes

Notes:

- Contractor shall provide, where applicable, GMT Fuses, cable trays, power cables, Ethernet cables, fiber patch cabling, fiber guides, steel plate, etc.

- Contractor shall refer to installation guides (NIG) for the appropriate wire gauge for DC Power cables.

- Fibre cable testing of all Fibre cables as per Civil/NI standards after cable installations have been completed and terminated. All testing result documents will be
supplied as per NI instructions

.- Ethernet cables testing as per cable type also required for all cables not pre-manufacture made. All testing result documents will be supplied as per NI
instructions.

- For proper installation refer to installation guides (NIG). Updated indexes & guides can be requested at quality.control@rci.rogers.com.

- RETURN UNUSED EQUIPMENT TO WAREHOUSE WHERE APPLICABLE.

No Location Code Site Name Action


3
3 C0368 CHALK RIVER As-builts

Please contact Equipment Engineering work order designer, approver or other designers for discrepancies found on site for record updating.

All changes will require the designer approval.

Any changes done overnight or week end need to be reported next business day.

Page 3 of 74 C0368-EI-2502-504-1-MW1-A
Equipment Engineering Requirement Form
Site EERF#: C0368-EI-2502-504-1-MW1-A
Oracle No.: 177833 Project Number: 2502-504 Date: 7-Apr-2022

C.A. NO: Project Name: Yr-2022 EORN IPRAN Transport Upgrades


Approver: Chidozie Eze Sites Names: CHALK RIVER
Shipping Address: Rogers Communications Inc. Location Code: C0368
7810 Keele Street, Unit B APPROVED BY
Vaughan, Ontario, L4K 0B7 Province: ONTARIO
Canada
ATTN: Peter Coutinho Webster (647) 747-9040 Requested By: Ian Correa
From Taken From Storage
Supplier QTY Bal. Vendor Parts # RWI Parts # Item Description ORACLE | TASK Location
BULK # PO #
Cisco Systems
1 288 SFP-10G-LR-S= 128-101N-4E SFP+ 10GBASE-LR Module, Enterprise-Class (IPRAN) BULK-ON220110-
2502-504 (CISCO) 177833 | 2.06 NR1

Alpha
Technologies 1 59 470-302-10 4A3-104M-4U BREAKER 5 AMP, Plug-In Type w/ Aux Switch Ctr Pin only, BULK-ON220613-
MidTrip (5/16" Bullet term), for Alpha-Argus Pwr Syst 2502-504 (NI) 177833 | 2.06
Alpha
Technologies 2 42 470-309-10 4A3-402R-4U BREAKER 40 AMP, Plug-In Type w/ Aux Switch Ctr Pin
only, MidTrip (5/16" Bullet term), for Alpha-Argus Pwr Syst
BULK-ON220613-
2502-504 (NI) 177833 | 2.06
Ericsson
1 92 BFZ62216/1 122-108C-07 MINI-LINK 6693: LTU 1001 BULK-ON220613-
2502-504 (NI) 177833 | 2.03 NR1

Ericsson
1 188 RPM 119 0681/1 124-414F-07 Mini-Link TN: 4-T1 cable 50-ft with connector BULK-ON220613-
2502-504 (NI) 177833 | 2.03 NR1

Graybar
Canada 1 59 SM8TAT2SA-DC 110-1002-FJ Smart Managed PoE+ Switch, 8 GE PoE+, 2 100/1000 SFP,
48VDC, 19” RK MT Brackets
BULK-ON220613-
2502-504 (NI) 177833 | 2.06
Alpha
Technologies -2 184 470-304-10 4A4-400S-4U BREAKER 15 AMP, Plug-In Type w/ Aux Switch Ctr Pin
only, MidTrip (5/16" Bullet term), for Alpha-Argus Pwr Syst
STOCK-CC1
NR1 | NR1

Printed on April 8, 2022 Page 1 of 1


Page 4 of 74 C0368-EI-2502-504-1-MW1-A
Site A-Gateway Site B-Gateway
LinkID A_Code LCAname Z_Code LCZname Subnet Mask= Site A-Host Name Site A-IP Address Site A-Label (Extra) Subnet Mask= Site B-Host Name Site B-IP Address Site B-Label (Extra) FacilityStatus MW Type
Project no. 255.255.224.0 255.255.224.0
ML6363_ML6692 8GHz 4DE_4x296Mbps (4+4) SD with 2
2502‐504 C0368_C0414_2 C0368 CHALK RIVER C0414 PEMBROKE 172.29.128.1 mw‐c0368‐02 172.29.142.75 C0368/ML6692/C0414 172.29.128.1 mw‐c0414‐23 172.29.142.76 C0414/ML6692/C0368 HW Upgrade (Major) XPICs (MW ‐ Transmission) HW Upgrade

Page 5 of 74 C0368-EI-2502-504-1-MW1-A
Location Code: C0368

Gateway: 172.29.128.1 Subnet Mask: 255.255.224.0 (/19)

IP Address Host Name Device Type User−Defined Fields

172.29.142.77 sw−c0368−01 Switch C0368/SM8TAT2SA−DC/01

Page 6 of 74 C0368-EI-2502-504-1-MW1-A
REFERENCE

Page 7 of 74 C0368-EI-2502-504-1-MW1-A
INSTALLATION

Page 8 of 74 C0368-EI-2502-504-1-MW1-A
BEFORE

Page 9 of 74 C0368-EI-2502-504-1-MW1-A
AFTER

To be decommissioned

Disconnection/Connection to be
done at the time of the PWO cutover

Page 10 of 74 C0368-EI-2502-504-1-MW1-A
BEFORE

Page 11 of 74 C0368-EI-2502-504-1-MW1-A
AFTER

Disconnection/Connection to be
done at the time of the PWO cutover

Page 12 of 74 C0368-EI-2502-504-1-MW1-A
BEFORE

Move up 1 RU

Page 13 of 74 C0368-EI-2502-504-1-MW1-A
AFTER

Install 1x ML6692 MW /C0414

REF: T-LAN/01

Install 1x SM8TAT2SA-DC

REF: DSX/C

Page 14 of 74 C0368-EI-2502-504-1-MW1-A
REFERENCE

REF: Cisco NCS 540

Page 15 of 74 C0368-EI-2502-504-1-MW1-A
REFERENCE

Connect ML6692 MW facing


C0414

Page 16 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 32
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

BEFORE
RACK 203.2/ALPHA VISTA II
2
POWER CONNECTION REPORT
EQPT DIST SHLF
PANEL PANEL/1A
3
Breaker Port <‐‐‐‐> Rack Equipment Slot Card Port WO
15A 01 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 PFU/01 PFU/A A
15A 02 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 PFU/02 PFU/B B
10A 03 FREE AIR COOLING - DAQS A
10A 04 103.3/MISC CSD-C0368-01 (NCS540) A C0368-EI-1913-505-5-SW1-B
15A 05 103.4/MISC BB6648-LTE/01 IN C0368-EI-1913-505-BT1-A
15A 06 103.4/MISC BB6648-5G/3.5GHz IN C0368-EI-2907-507-1-BT1-A
07
08
09
10A 10 103.3/MISC CSD-C0368-01 (NCS540) B C0368-EI-1913-505-5-SW1-B
11
12
13
14
15
16
17
18

Page 17 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 32
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

AFTER 2
POWER CONNECTION REPORT
RACK 203.2/ALPHA VISTA II
EQPT DIST SHLF
PANEL PANEL/1A
3
Breaker Port <‐‐‐‐> Rack Equipment Slot Card Port WO
15A 01 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 PFU/01 PFU/A A
15A 02 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 PFU/02 PFU/B B
10A 03 FREE AIR COOLING - DAQS CSD- A
10A 04 103.3/MISC C0368-01 (NCS540) A C0368-EI-1913-505-5-SW1-B
15A 05 103.4/MISC BB6648-LTE/01 IN C0368-EI-1913-505-BT1-A
15A 06 103.4/MISC BB6648-5G/3.5GHz IN C0368-EI-2907-507-1-BT1-A
40A 07-CRITICAL 103.4/MISC ML6692/C0414 Slot 3 PFU-1201 A C0368-EI-2502-504-1-MW1-A
40A 08-CRITICAL 103.4/MISC ML6692/C0414 Slot 4 PFU-1201 B C0368-EI-2502-504-1-MW1-A
5A 09-CRITICAL 103.4/MISC SM8TAT2SA-DC/01 IN C0368-EI-2502-504-1-MW1-A
10A 10 103.3/MISC CSD-C0368-01 (NCS540) B C0368-EI-1913-505-5-SW1-B
11
12
13
14
15
16
17
18

Page 18 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 98
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

BEFORE 2
CONNECTION REPORT
Eqpt DSX/C
Rack 103.4/MISC
3
Port <‐‐‐‐> Rack Equipment Slot Card Port WO
01 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B DS1 - 01
02 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B DS1 - 02
03 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B DS1 - 03
04 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B DS1 - 04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48

Page 19 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 98
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

BEFORE 2
CONNECTION REPORT
Eqpt DSX/C
Rack 103.4/MISC
3
Port <‐‐‐‐> Rack Equipment Slot Card Port WO
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
A

Page 20 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 98
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

AFTER 2
CONNECTION REPORT
Eqpt DSX/C
Rack 103.4/MISC
3
Port <‐‐‐‐> Rack Equipment Slot Card Port WO
01 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B DS1 - 01
02 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B DS1 - 02
03 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B DS1 - 03
04 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B DS1 - 04
05 103.4/MISC ML6692/C0414 Slot 7 LTU 1001 7/1A C0368-EI-2502-504-1-MW1-A
06 103.4/MISC ML6692/C0414 Slot 7 LTU 1001 7/1B C0368-EI-2502-504-1-MW1-A
07 103.4/MISC ML6692/C0414 Slot 7 LTU 1001 7/1C C0368-EI-2502-504-1-MW1-A
08 103.4/MISC ML6692/C0414 Slot 7 LTU 1001 7/1D C0368-EI-2502-504-1-MW1-A
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48

Page 21 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 98
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

AFTER 2
CONNECTION REPORT
Eqpt DSX/C
Rack 103.4/MISC
3
Port <‐‐‐‐> Rack Equipment Slot Card Port WO
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
A

Page 22 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 27
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

BEFORE 2
CONNECTION REPORT
Eqpt T-LAN/01 (E44M)
Rack 103.4/MISC
3
Port <‐‐‐‐> Rack Equipment Slot Card Port WO
DC PWR IN A 104.2/RECT +24V PANEL/2A (CRITICAL) 03
DC PWR IN B 104.2/RECT +24V PANEL/2A (CRITICAL) 01
LAN/1 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B NPU3-TR2
LAN/2 203.2/ALPHA VISTA II RECT SHELF CTRL CXCM4 NETWORK
LAN/3 FREE AIR COOLING - DAQS CONTROLLER
LAN/4
MODEM
RIO/EXP (RJ45)
SERIAL/1
SERIAL/2 C0368-EI-1913-505-5-SW1-B
SERIAL/3 103.3/MISC CSD-C0368-01 (NCS540) CONSOLE C0368-EI-1913-505-5-SW1-B
SERIAL/4
WAN/01 103.4/MISC DSX/A 2 DSX-1 13
WAN/02 103.4/MISC DSX/A 2 DSX-1 14

Disconnect MLTN8-1X195MBPS(1+1)/C0414 and


connect SM8TAT2SA-DC

Page 23 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 27
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

AFTER 2
CONNECTION REPORT
Eqpt T-LAN/01 (E44M)
Rack 103.4/MISC
3
Port <‐‐‐‐> Rack Equipment Slot Card Port WO
DC PWR IN A 104.2/RECT +24V PANEL/2A (CRITICAL) 03
DC PWR IN B 104.2/RECT +24V PANEL/2A (CRITICAL) 01
LAN/1 103.4/MISC SM8TAT2SA-DC/01 IP 01 C0368-EI-2502-504-1-MW1-A
LAN/2 203.2/ALPHA VISTA II RECT SHELF CTRL CXCM4 NETWORK
LAN/3 FREE AIR COOLING - DAQS CONTROLLER
LAN/4
MODEM
RIO/EXP (RJ45)
SERIAL/1
SERIAL/2 C0368-EI-1913-505-5-SW1-B
SERIAL/3 103.3/MISC CSD-C0368-01 (NCS540) CONSOLE C0368-EI-1913-505-5-SW1-B
SERIAL/4
WAN/01 103.4/MISC DSX/A 2 DSX-1 13
WAN/02 103.4/MISC DSX/A 2 DSX-1 14

Page 24 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 22
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

NEW 2
CONNECTION REPORT
Eqpt SM8TAT2SA-DC/01
Rack 103.4/MISC
3
Port <‐‐‐‐> Rack Equipment Slot Card Port WO
IP 01 103.4/MISC T-LAN/01 (E44M) LAN/1 C0368-EI-2502-504-1-MW1-A
IP 02 103.4/MISC ML6692/C0414 Slot 9 NPU 1005 TN4/LAN C0368-EI-2502-504-1-MW1-A
IP 03 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B NPU3-TR2 C0368-EI-2502-504-1-MW1-A
IP 04 C0368-EI-2502-504-1-MW1-A
IP 05 C0368-EI-2502-504-1-MW1-A
IP 06 C0368-EI-2502-504-1-MW1-A
IP 07 C0368-EI-2502-504-1-MW1-A
IP 08 C0368-EI-2502-504-1-MW1-A
A 203.2/ALPHA VISTA II DIST SHELF 09-CRITICAL C0368-EI-2502-504-1-MW1-A

Page 25 of 74 C0368-EI-2502-504-1-MW1-A
REMOVAL
To be done AFTER
PWO Cutover

Page 26 of 74 C0368-EI-2502-504-1-MW1-A
BEFORE

Existing ML-TN facing C0414

Page 27 of 74 C0368-EI-2502-504-1-MW1-A
AFTER

REF: RJ-45/01

Page 28 of 74 C0368-EI-2502-504-1-MW1-A
REFERENCE

REF: SM8TAT2SA-DC
Switch

REF: DSX/C

Page 29 of 74 C0368-EI-2502-504-1-MW1-A
REFERENCE

REF: SM8TAT2SA-DC
Switch

REF: DSX/C

Page 30 of 74 C0368-EI-2502-504-1-MW1-A
REFERENCE

Disconnect MLTN/C0414

Page 31 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 32
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

BEFORE 2
POWER CONNECTION REPORT
RACK 203.2/ALPHA VISTA II
EQPT DIST SHLF
PANEL PANEL/1A
3
Breaker Port <‐‐‐‐> Rack Equipment Slot Card Port WO
15A 01 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 PFU/01 PFU/A A
15A 02 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 PFU/02 PFU/B B
10A 03 FREE AIR COOLING - DAQS A
10A 04 103.3/MISC CSD-C0368-01 (NCS540) A C0368-EI-1913-505-5-SW1-B
15A 05 103.4/MISC BB6648-LTE/01 IN C0368-EI-1913-505-BT1-A
15A 06 103.4/MISC BB6648-5G/3.5GHz IN C0368-EI-2907-507-1-BT1-A
40A 07-CRITICAL 103.4/MISC ML6692/C0414 Slot 3 PFU-1201 A C0368-EI-2502-504-1-MW1-A
40A 08-CRITICAL 103.4/MISC ML6692/C0414 Slot 4 PFU-1201 B C0368-EI-2502-504-1-MW1-A
5A 09-CRITICAL 103.4/MISC SM8TAT2SA-DC/01 IN C0368-EI-2502-504-1-MW1-A
10A 10 103.3/MISC CSD-C0368-01 (NCS540) B C0368-EI-1913-505-5-SW1-B
11
12
13
14
15
16
17
18

Page 32 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 32
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

AFTER 2
POWER CONNECTION REPORT
RACK 203.2/ALPHA VISTA II
EQPT DIST SHLF
PANEL PANEL/1A
3
Breaker Port <‐‐‐‐> Rack Equipment Slot Card Port WO
01 C0368-EI-2502-504-1-MW1-A
02 C0368-EI-2502-504-1-MW1-A
10A 03 FREE AIR COOLING - DAQS A
10A 04 103.3/MISC CSD-C0368-01 (NCS540) A C0368-EI-1913-505-5-SW1-B
15A 05 103.4/MISC BB6648-LTE/01 IN C0368-EI-1913-505-BT1-A
15A 06 103.4/MISC BB6648-5G/3.5GHz IN C0368-EI-2907-507-1-BT1-A
40A 07-CRITICAL 103.4/MISC ML6692/C0414 Slot 3 PFU-1201 A C0368-EI-2502-504-1-MW1-A
40A 08-CRITICAL 103.4/MISC ML6692/C0414 Slot 4 PFU-1201 B C0368-EI-2502-504-1-MW1-A
5A 09-CRITICAL 103.4/MISC SM8TAT2SA-DC/01 IN C0368-EI-2502-504-1-MW1-A
10A 10 103.3/MISC CSD-C0368-01 (NCS540) B C0368-EI-1913-505-5-SW1-B
11
12
13
14
15
16
17
18

Page 33 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 98
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

BEFORE 2
CONNECTION REPORT
Eqpt DSX/C
Rack 103.4/MISC
3
Port <‐‐‐‐> Rack Equipment Slot Card Port WO
01 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B DS1 - 01
02 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B DS1 - 02
03 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B DS1 - 03
04 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B DS1 - 04
05 103.4/MISC ML6692/C0414 Slot 7 LTU 1001 7/1A C0368-EI-2502-504-1-MW1-A
06 103.4/MISC ML6692/C0414 Slot 7 LTU 1001 7/1B C0368-EI-2502-504-1-MW1-A
07 103.4/MISC ML6692/C0414 Slot 7 LTU 1001 7/1C C0368-EI-2502-504-1-MW1-A
08 103.4/MISC ML6692/C0414 Slot 7 LTU 1001 7/1D C0368-EI-2502-504-1-MW1-A
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48

Page 34 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 98
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

BEFORE 2
CONNECTION REPORT
Eqpt DSX/C
Rack 103.4/MISC
3
Port <‐‐‐‐> Rack Equipment Slot Card Port WO
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
A

Page 35 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 98
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

AFTER 2
CONNECTION REPORT
Eqpt DSX/C
Rack 103.4/MISC
3
Port <‐‐‐‐> Rack Equipment Slot Card Port WO
01 C0368-EI-2502-504-1-MW1-A
02 C0368-EI-2502-504-1-MW1-A
03 C0368-EI-2502-504-1-MW1-A
04 C0368-EI-2502-504-1-MW1-A
05 103.4/MISC ML6692/C0414 Slot 7 LTU 1001 7/1A C0368-EI-2502-504-1-MW1-A
06 103.4/MISC ML6692/C0414 Slot 7 LTU 1001 7/1B C0368-EI-2502-504-1-MW1-A
07 103.4/MISC ML6692/C0414 Slot 7 LTU 1001 7/1C C0368-EI-2502-504-1-MW1-A
08 103.4/MISC ML6692/C0414 Slot 7 LTU 1001 7/1D C0368-EI-2502-504-1-MW1-A
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48

Page 36 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 98
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

AFTER 2
CONNECTION REPORT
Eqpt DSX/C
Rack 103.4/MISC
3
Port <‐‐‐‐> Rack Equipment Slot Card Port WO
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
A

Page 37 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 37
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

BEFORE 2
CONNECTION REPORT
Eqpt RJ-45/01
Rack 103.3/MISC
3
Port <‐‐‐‐> Rack Equipment Slot Card Port WO
01 201.3/UMTS 850-3206 DIGITAL-SUBRACK/01(IN 3206) ET/01 ET-MFX11 NODE B PRT
02 201.3/UMTS 850-3206 DIGITAL-SUBRACK/01(IN 3206) ET/01 ET-MFX11 SPARE PRT 1
03 201.3/UMTS 850-3206 DIGITAL-SUBRACK/01(IN 3206) ET/01 ET-MFX11 SITE LAN
04 201.3/UMTS 850-3206 DIGITAL-SUBRACK/01(IN 3206) ET/01 ET-MFX11 SPARE PRT 2
05 103.3/MISC CSD-C0368-01 (NCS540) Gi0/0/0/0 C0368-EI-1913-505-5-SW1-B
06 103.3/MISC CSD-C0368-01 (NCS540) Gi0/0/0/6 C0368-EI-1913-505-5-SW1-B
07 103.3/MISC CSD-C0368-01 (NCS540) Gi0/0/0/1 C0368-EI-1913-505-5-SW1-B
08 103.3/MISC RBS-6601-V2/01 DUS-1 DUS-1 DUS-1 TN A
09
10
11 C0368-EI-1913-505-5-SW1-B
12
13 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B NPU3-TR3
14 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 ETU3 ETU3 ETU3-TR3
15 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 ETU3 ETU3 ETU3-TR4
16
17
18
19
20
21
22
23
24

Page 38 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 37
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

AFTER 2
CONNECTION REPORT
Eqpt RJ-45/01
Rack 103.3/MISC
3
Port <‐‐‐‐> Rack Equipment Slot Card Port WO
01 201.3/UMTS 850-3206 DIGITAL-SUBRACK/01(IN 3206) ET/01 ET-MFX11 NODE B PRT
02 201.3/UMTS 850-3206 DIGITAL-SUBRACK/01(IN 3206) ET/01 ET-MFX11 SPARE PRT 1
03 201.3/UMTS 850-3206 DIGITAL-SUBRACK/01(IN 3206) ET/01 ET-MFX11 SITE LAN
04 201.3/UMTS 850-3206 DIGITAL-SUBRACK/01(IN 3206) ET/01 ET-MFX11 SPARE PRT 2
05 103.3/MISC CSD-C0368-01 (NCS540) Gi0/0/0/0 C0368-EI-1913-505-5-SW1-B
06 103.3/MISC CSD-C0368-01 (NCS540) Gi0/0/0/6 C0368-EI-1913-505-5-SW1-B
07 103.3/MISC CSD-C0368-01 (NCS540) Gi0/0/0/1 C0368-EI-1913-505-5-SW1-B
08 103.3/MISC RBS-6601-V2/01 DUS-1 DUS-1 DUS-1 TN A
09
10
11 C0368-EI-1913-505-5-SW1-B
12
13 C0368-EI-2502-504-1-MW1-A
14 C0368-EI-2502-504-1-MW1-A
15 C0368-EI-2502-504-1-MW1-A
16
17
18
19
20
21
22
23
24

Page 39 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 22
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

BEFORE 2
CONNECTION REPORT
Eqpt SM8TAT2SA-DC/01
Rack 103.4/MISC
3
Port <‐‐‐‐> Rack Equipment Slot Card Port WO
IP 01 103.4/MISC T-LAN/01 (E44M) LAN/1 C0368-EI-2502-504-1-MW1-A
IP 02 103.4/MISC ML6692/C0414 Slot 9 NPU 1005 TN4/LAN C0368-EI-2502-504-1-MW1-A
IP 03 103.3/MISC MLTN8-1X195MBPS(1+1) SD/C0414 NPU3 NPU3B NPU3-TR2 C0368-EI-2502-504-1-MW1-A
IP 04 C0368-EI-2502-504-1-MW1-A
IP 05 C0368-EI-2502-504-1-MW1-A
IP 06 C0368-EI-2502-504-1-MW1-A
IP 07 C0368-EI-2502-504-1-MW1-A
IP 08 C0368-EI-2502-504-1-MW1-A
A 203.2/ALPHA VISTA II DIST SHELF 09-CRITICAL C0368-EI-2502-504-1-MW1-A

Page 40 of 74 C0368-EI-2502-504-1-MW1-A
Province ON 22
LOC C0368
Site Name CHALK RIVER
Address 30786 HIGHWAY 17
EMG PM06P
CLLI CKRVON01
1

AFTER 2
CONNECTION REPORT
Eqpt SM8TAT2SA-DC/01
Rack 103.4/MISC
3
Port <‐‐‐‐> Rack Equipment Slot Card Port WO
IP 01 103.4/MISC T-LAN/01 (E44M) LAN/1 C0368-EI-2502-504-1-MW1-A
IP 02 103.4/MISC ML6692/C0414 Slot 9 NPU 1005 TN4/LAN C0368-EI-2502-504-1-MW1-A
IP 03 C0368-EI-2502-504-1-MW1-A
IP 04 C0368-EI-2502-504-1-MW1-A
IP 05 C0368-EI-2502-504-1-MW1-A
IP 06 C0368-EI-2502-504-1-MW1-A
IP 07 C0368-EI-2502-504-1-MW1-A
IP 08 C0368-EI-2502-504-1-MW1-A
A 203.2/ALPHA VISTA II DIST SHELF 09-CRITICAL C0368-EI-2502-504-1-MW1-A

Page 41 of 74 C0368-EI-2502-504-1-MW1-A
REFERENCE
ML6692 With NPU 1005
[The numbers in the table cells indicate the priority order in which the slots need to be used by each]
Slot
Plug‐in Unit
S0 S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12
FAU 1201 1
PFU 1201 1 2
NPU 1005 1 2
ETU 1002 2 1 3 x(5) x(5) x(5) x(5) x(5)
ETU 1001 2 1 3 x(5) x(5) x(5) x(5) x(5)
MMU 1002 with EQP 4 4 1 1 3 3 2 2
MMU 1004 with EQP 4 4 1 1 3 3 2 2
MMU 1001 with EQP 4 4 1 1 3 3 2 2
LTU 1002 with MSP 4 4 1 1 3 3 2 2
MMU 1002 4 8 1 5(4) 3(4) 7(4) 2(4) 6(4)
MMU 1004 4 8 1 5(4) 3(4) 7(4) 2(4) 6(4)
MMU 1001 4 8 5 1 3 7 2 6
LTU 1001 1 2 3 4 5
x(5) x(5) x(5)
LTU 1002 1 2 3 4 5
x(5) x(5) x(5)
(4) Number of microwave directions is limited to one in this slot.
(5) Possible, but not a prioritized slot.

The following pairs of slots are interconnected (2‐BPI) in the MINI‐LINK 6692 backplane, and can be used for EQP:
∙ Slots 5 and 6
∙ Slots 11 and 12
∙ Slots 7 and 8
∙ Slots 1 and 2
The same slot combinations apply as for 1+1 RLP and 2+0 RLB EQP configurations.

APU Slot Backplane Capacity for NPU 1005:


Slot Ethernet capacity [Gbps]
6 1×2.5
5 1×2.5
2 1×2.5
1 1×2.5
12 1×2.5
11 1×2.5
8 1×2.5
7 1×2.5

Page 42 of 74 C0368-EI-2502-504-1-MW1-A
Power System Summary
REFERENCE Printed on 2022‐04‐06 4:17:26 PM Page 1 of 1
Site Power Systems
Date: 06‐Apr‐2022
Location Code Site Name No Voltage Manufacturer System Model Rack Typ (A) Peak (A)
C0368 CHALK RIVER 1 24 Lorain 1211‐10 80.9 99.4
2 48 Alpha Vista II 133.2 212.2
Province EMG In‐Service Date Site Status Lastest Project
ON PM06P 24‐Jun‐1992 In Service 2502‐504

In/Out: Indoor Site Type: End Generator:


Site Venue: GROUND Shelter: Shelter Conn. Box: GROUND LEVEL SHELT
Backup Non Crit Critical Access Time Access Summer Access Winter Comments Add 1 ML6692 and 8x ML6363.
Spec (Hour) 4 8 Hrs.
Last Updated: Parallel (2022‐04‐06 3:17:40 PM)

Pwr Syst ID C0368_48V_2_Vista II


Voltage: Manufacturer: System Model: Syst No: Rack No:
48 V Alpha Vista II 2
Non Critical Loads Critical Loads Batteries
Device Qty Typ (W) Peak (W) I/O Device Qty Typ (W) Peak (W) I/O No Batt Type Cond Date Tested Rack Nom AH Design AH Actual AH
RRUS 80W 3 660 900 O Cisco NCS 540 1 200 240 I 1 SBS 190 100% 190 142.72 178.4
Radio 4449 (600 3 1,695 2,808 O Baseband 6648 2 758 816 I 2 SBS 190 100% 190 142.72 178.4
Radio 4415 3 867 1,536 O ML 6692 MW Sh 1 266 313 I 3 SBS 190 100% 190 142.72 178.4
AIR 3258 3 1,545 3,171 O ML 6363 MW OD 8 264 264 O 4 SBS 190 100% 190 142.72 178.4
SM8TAT2SA‐DC ( 1 140 140 I

Backup Time
Non Critical Loads (W) 4,767 8,415 Critical Loads (W) 1,628 1,773 TYPICAL PEAK
Non Critical Loads (A) 99.3 175.3 Critical Loads (A) 33.9 36.9 Non Critical Critical Non Critical Critical
Converters Loads Designed 4.3 4.3 2.6 5.5
TOTAL SYSTEM LOADS
Backup (Hrs) PASS PASS FAIL FAIL
TYPICAL PEAK
6,395 10,188 [W] Actual 5.4 5.4 3.2 6.9
133.2 212.2 [A] Backup (Hrs) PASS PASS FAIL FAIL

Rectifiers
Rect Type Rect Qty TYPICAL PEAK
CXRF HP 4.0kW 3 Required Qty 3 4
Installed Qty 3 PASS 3 FAIL
Module Capacity W A

Non Critical Loads (A) Comments


Critical Loads (A)

Page 43 of 74 C0368-EI-2502-504-1-MW1-A
Engineering Design Specification

Engineering Design Specification:


C0368 CHALKRIVER – C0414 PEMBROKE
ML6363_ML6692 8GHz 4DE_4x296Mbps (4+4) SD with 2
XPICs (MW - Transmission) HW Upgrade

Project Number: 2502-504


Project Name: 2502-504 Yr2022 EORN IPRAN
Transport Upgrades
Project Type: Transmission Design Submission
Status:
Priority:
CA Number:
CA Approval Date:
Related Document Number:

Target In Service Date:


Regions Involved:

Revision Number: 1.0


Revision Date:
Original Release Date: November,13, 2021

Prepared By: Soumya_TCS


Department: Transmission
Contributors:
Documentation Supported By:
Checked By:
Authorized By: Hani Abraham
Distributed To:

The information in this document is the property of Rogers Communication Partnership. The receiver of this
document shall keep the information contained herein confidential and shall protect the same in whole or in
part from disclosure and dissemination to third parties. Disclosure and disseminations shall only be made on
a strict need to know basis and upon the consent of the author.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 1 of 31

Page 44 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

Revision History

Revision Date Revision Author Reason for Revision


November ,13, 2021 1 Soumya_TCS Original/Initial Release of document

4
5
6
7

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 2 of 31

Page 45 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

Table of Contents

1.0 Executive Summary ............................................................................................................................................ 4

2.0 Scope Section ..................................................................................................................................................... 4


2.1 Scope of Work ...................................................................................................................................... 4

3.0 Financial Section ................................................................................................................................................ 4


3.1 General Information ............................................................................................................................. 4
3.2 Inter-company/department Charges (if applicable) .............................................................................. 4
3.3 Bill of Materials ................................................................................................................................... 5

4.0 Technical Section ............................................................................................................................................... 7


4.1 Design Overview .................................................................................................................................. 7
4.2 END-TO-END SPECIAL INSTRUCTIONS FOR INSTALLATION/COMMISSIONING ............... 7
4.3 Configuration Details ........................................................................................................................... 26
4.4 End to End Impact Assessment ............................................................................................................ 29
4.4.1 Impact Classification ........................................................................................................... 29
4.5 Technical Pre-requisites ....................................................................................................................... 29
4.6 Testing and Field Acceptance .............................................................................................................. 29
4.6.1 Testing to be executed......................................................................................................... 29

5.0 Execution section ................................................................................................................................................ 30


5.1 Timing .................................................................................................................................................. 30
5.2 Project Dependencies ........................................................................................................................... 30
5.2.1 Project Pre-requisites (N/A) ................................................................................................ 30
5.2.2 Project Co-requisites (NIL) ................................................................................................. 30
5.2.3 Dependent or Related Projects (NIL) ..................................................................................30
5.3 Migration, Decommissioning and Redeployment Activities ................................................................ 30

6. 0 Functional Area and Responsibility ................................................................................................................... 30

7.0 Recommended Training...................................................................................................................................... 31

8.0 Reference Documents ......................................................................................................................................... 31


8.1 Ericsson ML6363, ML6692 and Antenna Installation and Operational Manual and MOPs........ 31

9.0 Abbreviations and Acronyms ............................................................................................................................. 31

Figures and Tables .................................................................................................................................................... 31

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 3 of 31

Page 46 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

1.0 Executive Summary

This project provides the design instructions and specifications to deploy a hardware upgrade,
ML6692_ML6363 8GHz (4+4) SD with 2 XPICs on MW link between C0368 CHALK RIVER and
C0414 PEMBROKER

2.0 Scope Section

2.1 Scope of Work

To complete the deployment of C0368 CHALK RIVER - C0414 PEMBROKER

ML6692_ML6363 8GHz 4 x 296Mbps (4+4) SD MW HW UPGRADE

THIS UPGRADE PROCEDURE IS SERVICE AFFECTING AND SHOULD BE


PERFORMED DURING THE LOW TRAFFIC PERIOD.

Hot cut/Perform a bench-test on the newly ordered ML6692_ML6363 8GHz 4 x


296Mbps (4+4) SD radio to ensure proper operation before installation

Total Usable Link Throughput (less 2% RLB deficiency) = 1160.32 Mbps

Link ID: C0368_C0414_2

3.0 Financial Section

3.1 General Information

CA Name and Number: TBD

Oracle Number(s): TBD

RPATS/Project #:

OPEX:

3.2 Inter-company/department Charges (if applicable)


Internal Company Oracle Number Oracle Task Number Oracle Project Manager

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 4 of 31

Page 47 of 74 C0368-EI-2502-504-1-MW1-A
Engineering Design Specification

3.3 Bill of Materials

3.3.1 BOMs

C0368 CHALK RIVER and C0414 PEMBROKER

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 5 of 31

Page 48 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

3.3.2 BOMs

C0368 CHALK RIVER and C0414 PEMBROKER

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 6 of 31

Page 49 of 74 C0368-EI-2502-504-1-MW1-A
Engineering Design Specification

4.0 Technical Section

4.1 Design Overview

This project provides the design instructions and specifications to deploy a permanent MW link between
C0368 CHALK RIVER and C0414 PEMBROKER

4.2 END-TO-END SPECIAL INSTRUCTIONS FOR INSTALLATION/COMMISSIONING

SPECIAL INSTRUCTIONS – CIVIL

C0368 CHALK RIVER

THIS UPGRADE PROCEDURE IS SERVICE AFFECTING AND SHOULD BE


PERFORMED DURING THE LOW TRAFFIC PERIOD.

INSTALLATION
MICROWAVE

(1) Refer to path data sheet for azimuth, polarization, antenna height, etc. The required
tower twist and sway limits for HPX8-71Wantenna is 0.98 degrees and for USX6-7W
antenna is 1.3 degrees.

(2) Re-use existing HPX8-71W main antenna at 75m AGL and install new USX6-7W
diversity antenna with additional inboard side strut on to the tower at 61mAGL,
Azimuth = 134.29°, facing C0414 PEMBROKER. Refer to section 4.2.2 for a
drawing of the exact location of the antenna.

(3) Cross Polarization Adjustment is to be performed to ensure optimal XPIC


performance. Please refer to CommScope Technical Publication TP-108827.1-EN
(02/17) for cross polarization adjustment procedures.

(4) Install four (4+0) new ML6363 ODUs, with two IPS3 splitter kits, close to the HPX8-
71W main antenna, facing C0414 PEMBROKER. Install four new runs of LDF4-50
cable.

(5) Install four (4+0) new ML6363 ODUs, with two IPS3 splitter kits, close to the USX6-
7W diversity antenna, facing C0414 PEMBROKER. Install four new runs of LDF4-
50 cable,

(6) Use the newly installed runs of LDF4-50 cables to connect new ML6363 ODUs to the
indoor unit facing C0414 PEMBROKER.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 7 of 31

Page 50 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

(7) The existing (1+1) SDIV RAU2X 8GHz, ANT01.87/8HX antenna flex twist
waveguides, LDF2-50 cables, and the indoor MLTN AMM6p chassis are to be
decommissioned and removed after successful installation and commissioning of the
new ML6692_ML6363 radio systems.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 8 of 31

Page 51 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

SPECIAL INSTRUCTIONS - INSTALLATION/COMMISSIONING

C0368 CHALK RIVER

THIS UPGRADE PROCEDURE IS SERVICE AFFECTING AND SHOULD BE


PERFORMED DURING THE LOW TRAFFIC PERIOD.

INSTALLATION

MICROWAVE

(1) The Ericsson ML6363_ML6692 8GHz -4 x 296 Mbps (4+4) radio installation procedures
for the C0368 CHALK RIVER site must be followed in line with the corresponding Design
Submission for the C0414 PEMBROKE site.

(2) Shut down/power of (1+1) SDIV RAU2X 8GHz radio system and disconnect flex twist
waveguides connecting to the Horizontal ports of the existing HPX8-71W, existing
ANT01.87/8HX space diversity antenna system.

(3) Install two ML6363_ML6692 8GHz - 296 Mbps (2+0) Terminal radios (Tx/Rx:
7860.000/8160.000H;7890.000/8190.000HMHz:7860.000/8160.000V;7890.000/8190.000
V MHz) with OMT/IPS3 separation installation facing C0414 PEMBROKER. Refer to
Figure 1: Dual Polarized 4+4 6363/6692 SD XPIC/CCDP Schematic Installation Diagram,
fit the two ML6363 radio units and IPS3 symmetrical splitter using one new flex twist
waveguides to the Vertical and Horizontal ports of the OMT of the existing Main antenna,
HPX8-71W respectively each using one new flex twist waveguide.

(4) Using four new runs of LDF4-50 radio cables, connect the two outdoor ML6363 radio units
and terminate the Vertical ports to the MMU1002 modems (Slot 11/Port 1 and Slot 5/Port
1) and the Horizontal ports to (Slot 11/Port 2 and Slot 5/Port 2) respectively. Refer to
Figure 2: Interconnected Slot positions in ML 6692 Enclosure.

(5) Install another two ML6363_ML6692 8GHz - 296 Mbps (2+0) Terminal radios (Tx/Rx:
7860.000/8160.000H;7890.000/8190.000HMHz;7860.000/8160.000V;7890.000/8190.000
V MHz) with OMT/IPS3 separation installation facing C0414 PEMBROKER. Refer to
Figure 1: Dual Polarized 4+4 6363/6692 SD XPIC/CCDP Schematic Installation Diagram,
fit the two ML6363 radio units and IPS3 symmetrical splitter using one new flex twist
waveguides to the Vertical and Horizontal ports of the OMT of the newly Diversity
antenna, USX6-7W respectively each using one new flex twist waveguide.

(6) Using four new runs of LDF4-50 radio cables, connect the two outdoor ML6363 radio units
and terminate the Vertical ports to the MMU1002 modems (Slot 12/Port 1 and Slot 6/Port
1) and the Horizontal ports to (Slot 12/Port 2 and Slot 6/Port 2) respectively. Refer to
Figure 2: Interconnected Slot positions in ML 6692 Enclosure.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 9 of 31

Page 52 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

(7) Connect the SFP + (10G) transceiver module to Port TN: 7 of NPU 1005 (Slot 9) with
a fibre run to the Cisco or equivalent router. Refer to Figure 2: Interconnected Slot
positions in ML 6692 Enclosure.

(8) Refer to Equipment Engineering for power requirement, floor plan, and rack profile for the
installation of ML6692 chassis.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 10 of 31

Page 53 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

SPECIAL INSTRUCTIONS - INSTALLATION/COMMISSIONING


C0368 CHALK RIVER

THIS UPGRADE PROCEDURE IS SERVICE AFFECTING AND SHOULD BE


PERFORMED DURING THE LOW TRAFFIC PERIOD.

COMMISSIONING

MICROWAVE

(1) Ensure that the ML6363_ML6692 8GHz -4 x 296 Mbps (4+4) SD radio system at C0414
PEMBROKE facing C0368 CHALK RIVER is in place and ready. Note that this
microwave system is licensed to operate on the specified frequency pair, 4DE_ (4 x
296 Mbps), 4096 QAM Light modulation and 30MHz bandwidth according to this
design submission. Therefore, it is mandatory to commission the system
accordingly.

(2) Perform the following configuration and settings for each radio unit on the (2+0)
ML6363 8GHz – 296 Mbps radio terminals connecting to the Horizontal ports of
the Main and Diversity antennas respectively. Refer to Figures 3 and 4 for: 2+2
RLB EQP Configuration Block Diagram and 2 x (2+2 RLB) with Two MMU 1002
modems respectively.

(3) Use the Node GUI, configure the radio parameter, including Radio Link Terminal
(RLT), Terminal ID, and Far-End Terminal ID codes.

(4) Set Mode to 2+2 radio link protection with EQP.

(5) Set two Carrier Termination Members. Refer to the MOP “M-T-104: Ericsson
Mini-Link 6600 Series setup”.

(6) Configuring ACM:

a. Set Frame ID 1364: 30MHz, XPIC, 4-4096QAM, 39.963-296. 237Mbps


b. Set Min and Max ACM as follows:

(i) Min ACM: 4 QAM Strong (39.963Mbps)


(ii) Max ACM: 4096 QAM Light (296.237Mbps)
(iii) Wanted Licensed Capacity: 0.0 Mbps (See Note*)
(iv) Carrier ID; A
(v) Polarization: Vertical

Note *: It is a default 0.0 value to generate a license request for the capacity corresponding to
the configured Max ACM

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 11 of 31

Page 54 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

a. Ensure the AMS (Adaptive Modulation Seconds) default thresholds are set as
follows:
(i) 15 min Set Threshold: 180
(ii) 24 hours Set Threshold: 1500
(iii) 15 min Reset Threshold: 20

NOTE: Configuring QoS must be set in conjunction with ACM enabled. Please refer
to the MOP “M-T-104 Ericsson Mini-Link 6600 Series setup” for QoS configuration.

(7) Configuring the TX/RX frequencies and Output Power under the Radio Link option:

Please note that both the transmitter (TX) frequency and the receiver frequency (RX)
assignments in the MHz unit must be entered separately without any error.

a. Enter Tx frequency: Tx1: 7860.000 (MHz); Tx2: 7890.000 (MHz)


b. Enter Rx frequency: Rx1: 8160.000 (MHz); Rx2: 8190.000 (MHz)
c. Set Output Power Type: High power
d. Set Min and Max. Output Power for RTPC mode as follows:
(i) Min Output Power (dBm): 30
(ii) Max Output Power (dBm): 30
(iii) Ensure RTPC mode is set

(8) Repeat Step (3) to (7) for configuring the other two (2+0) ML6363 8GHz 296 Mbps radio
terminals connecting to the Horizontal antenna ports of the Main and Diversity antennas
respectively as follows:

a. Carrier ID: B
b. Polarization: Horizontal
c. Tx frequency: Tx1: 7860.000 (MHz); Tx2: 7890.000 (MHz)
d. Rx frequency: Rx1: 8160.000 (MHz); Rx2: 8190.000 (MHz)

(9) Configuring TDM: Use the Radio Link option, Configure Radio Link Terminal,

a. Refer to the Equipment Engineering work order for the DS1 requirement.
b. Under General, select the Connect TDM check-box, and set the number of wanted
DS1s in the Select D1 drop-down list.
c. Enable sufficient # of DS1s to support the new or TDM traffic. Allocate the
remaining capacity to Ethernet traffic.

(10) Configuring XPIC: Use the Radio Link option, Configure, click XPIC,

a. Ensure the RLT Mode is set to 2+2 Radio Link Protection;


b. In the Configure XPIC page, Enable XPIC check boxes under both XPIC Pair 1
and XPIC Pair 2.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 12 of 31

Page 55 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

(11) Configuring Hierarchical Radio Link Bonding (hRLB)

Refer to the MOP “M-T-104: Ericsson Mini-Link 6600 Series setup” on the
Hierarchical Radio Link Bonding Groups tab:

(i) Create a 2X (2+2) hRLB group from two RLTs (2+2 RLB EQP)
(ii) Add member interfaces to the hRLB group.

(12) Configuring Equipment Protection Switching

Refer to the MOP “M-T-104: Ericsson Mini-Link 6600 Series setup”

(i) Set the EQP switching mechanism mode to: Auto


(ii) Set MMU units that are connected to the Main antenna to be active in the EQP
configuration.

(13) Refer to Bulletin M-T-104 Ericsson Mini-Link 6600 Series and Bulletin T-T-064
Microwave Radio Testing, complete successfully all the required Acceptance tests for the
newly installed ML6363_ML6692 8GHz - 296 Mbps (4+4) SD XPIC radio system
between C0414 PEMBROKE and C0368 CHALK RIVER. Repeat any necessary
acceptance tests in the ML6363_ML6692 8GHz- 296 Mbps (4+4) system should the test
results fail.

(14) After commissioning the complete ML6363_ML6692 8GHz -4 x 296 Mbps (4+4) SD
XPIC system for normal operation, put the system into service.

(15) After successful traffic cut over to the new ML6363_ML6692 8GHz – 4 x 296 Mbps
(4+4) XPIC hop, decommission, and remove existing (1+1) SDIV RAU2X 8GHz
ODU, remove existing ANT01.87/8HX antenna, flex twist waveguides, LDF2-50
cables, indoor AMM6p chassis and its ancillary equipment, and return them to
warehouse for future purposes.

(16) Forward all testing and commissioning results to Transmission Engineering.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 13 of 31

Page 56 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

SPECIAL INSTRUCTIONS - CIVIL


C0414 PEMBROKER

THIS UPGRADE PROCEDURE IS SERVICE AFFECTING AND SHOULD BE


PERFORMED DURING THE LOW TRAFFIC PERIOD.

INSTALLATION

MICROWAVE

(1) Refer to path data sheet for azimuth, polarization, antenna height and etc. The required
tower twist and sway limits for HPX8-71Wantenna is 0.98 degrees and USX6-7Wantenna
is 1.3 degrees.

(2) Re-use existing antenna HPX8-71Wmain antenna at 96.1m and install new USX6-7W
diversity antenna with additional inboard side strut on to the tower at 78.4 m AGL,
Azimuth = 314.49°, facing C0368 CHALK RIVER. Refer to section 4.2.2 for a drawing
of the exact location of the antenna.

(3) Cross Polarization Adjustment is to be performed to ensure optimal XPIC performance.


Please refer to CommScope Technical Publication TP-108827.1-EN (02/17) for cross
polarization adjustment procedures.

(4) Install four (4+0) new ML6363 ODUs, with two IPS3 splitter kits, close to the HPX8-
71W main antenna, facing C0368 CHALK RIVER. Install four new runs of LDF4-50
cable.

(5) Install four (4+0) new ML6363 ODUs, with two IPS3 splitter kits, close to the USX6-7W
diversity antenna, facing C0368 CHALK RIVER. Install four new runs of LDF4-50
cable.

(6) Use the newly installed runs of LDF4-50 cables to connect new ML6363 ODUs to the
indoor unit facing C0368 CHALK RIVER.

(7) The existing (1+1) SDIV RAU2X 8GHz, ANT01.87/8HX antenna flex twist
waveguides, LDF2-50 cables, and the indoor MLTN AMM6p chassis are to be
decommissioned and removed after successful installation and commissioning of the new
ML6692_ML6363 radio system.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 14 of 31

Page 57 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

SPECIAL INSTRUCTIONS – INSTALLATION/COMMISSIONING


C0414 PEMBROKER

THIS UPGRADE PROCEDURE IS SERVICE AFFECTING AND SHOULD BE


PERFORMED DURING THE LOW TRAFFIC PERIOD

INSTALLATION

MICROWAVE

(1) The Ericsson ML6363_ML6692 8GHz -4 x 296 Mbps (4+4) radio installation procedures
for the C0414 PEMBROKE site must be followed in line with the corresponding Design
Submission for C0368 CHALK RIVER site.

(2) Shut down/power of (1+1) SDIV RAU2X 8GHz radio system and disconnect flex twist
waveguides connecting to the Horizontal ports of the existing HPX8-71W, existing
ANT01.87/8HX space diversity antenna system.

(3) Install two ML6363_ML6692 8GHz - 296 Mbps (2+0) Terminal radios (Tx/Rx:
8160.000/7860.000H;8190.000/7890.000HMHz;8160.000/7860.000V;8190.000/7890.000
V MHz) with OMT/IPS3 separation installation facing C0368 CHALK RIVER. Refer to
Figure 1: Dual Polarized 4+4 6363/6692 SD XPIC/CCDP Schematic Installation Diagram,
fit the two ML6363 radio units and IPS3 symmetrical splitter using one new flex twist
waveguides to the Vertical and Horizontal ports of the OMT of the existing Main antenna,
HPX8-71W respectively each using one new flex twist waveguide.

(4) Using four new runs of LDF4-50 radio cables, connect the two outdoor ML6363 radio units
and terminate the Vertical ports to the MMU1002 modems (Slot 11/Port 1 and Slot 5/Port
1) and the Horizontal ports to (Slot 11/Port 2 and Slot 5/Port 2) respectively. Refer to
Figure 2: Interconnected Slot positions in ML 6692 Enclosure.

(5) Install two ML6363_ML6692 8GHz - 296 Mbps (2+0) Terminal radios (Tx/Rx:
8160.000/7860.000H;8190.000/7890.000HMHz;8160.000/7860.000V;8190.000/7890.000
V MHz) with OMT/IPS3 separation installation facing C0368 CHALK RIVER. Refer to
Figure 1: Dual Polarized 4+4 6363/6692 SD XPIC/CCDP Schematic Installation Diagram,
fit the two ML6363 radio units and IPS3 symmetrical splitter using one new flex twist
waveguides to the Vertical and Horizontal ports of the OMT of the newly Diversity
antenna, USX6-7Wrespectively each using one new flex twist waveguide.

(6) Using four new runs of LDF4-50 radio cables, connect the two outdoor ML6363 radio units
and terminate the Vertical ports to the MMU1002 modems (Slot 12/Port 1 and Slot 6/Port
1) and the Horizontal ports to (Slot 12/Port 2 and Slot 6/Port 2) respectively. Refer to
Figure 2: Interconnected Slot positions in ML 6692 Enclosure.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 15 of 31

Page 58 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

(7) Connect the SFP + (10G) transceiver module to Port TN: 7 of NPU 1005 (Slot 9) with
a fibre run to the Cisco or equivalent router. Refer to Figure 2: Interconnected Slot
positions in ML 6692 Enclosure.

(8) Refer to Equipment Engineering for power requirement, floor plan, and rack profile for the
installation of ML6692 chassis.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 16 of 31

Page 59 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

SPECIAL INSTRUCTIONS - INSTALLATION/COMMISSIONING


C0414 PEMBROKER

THIS UPGRADE PROCEDURE IS SERVICE AFFECTING AND SHOULD BE


PERFORMED DURING THE LOW TRAFFIC PERIOD

COMMISSIONING

MICROWAVE

(1) Ensure that the ML6363_ML6692 8GHz -4 x 296 Mbps (4+4) SD radio system at C0368
CHALK RIVER facing C0414 PEMBROKE is in place and ready. Note that this
microwave system is licensed to operate on the specified frequency pair, 4DE_ (4 x
296 Mbps), XPIC, 4096 QAM Light modulation, and 30MHz bandwidth according
to this design submission. Therefore, it is mandatory to commission the system
accordingly.

(2) Perform the following configuration and settings for each radio unit on the (2+0)
ML6363 8GHz - 296Mbps radio terminals connecting to the Horizontal ports of
the Main and Diversity antennas respectively. Refer to Figures 3 and 4 for: 2+2
RLB EQP Configuration Block Diagram and 2 x (2+2 RLB) with Two MMU 1002
modems respectively.

(3) Use the Node GUI, configure the radio parameter, including Radio Link Terminal
(RLT), Terminal ID, and Far-End Terminal ID codes.

(4) Set Mode to 2+2 radio link protection with EQP.

(5) Set two Carrier Termination Members. Refer to the MOP “M-T-104: Ericsson
Mini-Link 6600 Series setup”.

(6) Configuring ACM:

a. Set Frame ID 1364: 30MHz, XPIC, 4-4096QAM, 39.963-296.237Mbps


b. Set Min and Max ACM as follows:

(i) Min ACM: 4 QAM Strong (39.963Mbps)


(ii) Max ACM: 4096 QAM Light (296.237Mbps)
(iii) Wanted Licensed Capacity: 0.0 Mbps (See Note*)
(iv) Carrier ID: A
(v) Polarization: Vertical

Note *: It is a default 0.0 value to generate a license request for the capacity corresponding to
the configured Max ACM

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 17 of 31

Page 60 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

c. Ensure the AMS (Adaptive Modulation Seconds) default thresholds are set as
follows:
(i) 15 min Set Threshold: 180
(ii) 24 hours Set Threshold: 1500
(iii) 15 min Reset Threshold: 20

NOTE: Configuring QoS must be set in conjunction with ACM enabled. Please refer
to MOP “M-T-104 Ericsson Mini-Link 6600 Series setup” for QoS configuration

(7) Configuring the TX/RX frequencies and Output Power under the Radio Link option:

Please note that both the transmitter (TX) frequency and the receiver frequency (RX)
assignments in MHz unit must be entered separately without any error.

a. Enter Tx frequency: Tx1: 8160.000 (MHz); Tx2: 8190.000 (MHz)


b. Enter Rx frequency: Rx1: 7860.000 (MHz); Rx2: 7890.000 (MHz)
c. Set Output Power Type: High power
d. Set Min and Max. Output Power for RTPC mode as follows:
(i) Min Output Power (dBm): 30
(ii) Max Output Power (dBm): 30
(iii) Ensure RTPC mode is set

(8) Repeat Step (3) to (7) for configuring the other two (2+0) ML6363_ML6692 8GHz 296
Mbps 1+0 radio connecting to the Horizontal antenna port as follows:

a. Carrier ID: B
b. Polarization: Horizontal
c. Enter Tx frequency: Tx1: 8160.000 (MHz); Tx2: 8190.000 (MHz)
d. Enter Rx frequency: Rx1: 7860.000 (MHz); Rx2: 7890.000 (MHz)

(9) Configuring TDM: Use the Radio Link option, Configure Radio Link Terminal,

a. Refer to the Equipment Engineering work order for the DS1 requirement.
b. Under General, select the Connect TDM check-box, and set the number of wanted
DS1s in the Select D1 drop-down list.
c. Enable sufficient # of DS1s to support the new or TDM traffic. Allocate the
remaining capacity to Ethernet traffic

(10) Configuring XPIC: Use the Radio Link option, Configure, click XPIC,

a. Ensure the RLT Mode is set to 2+2 Radio Link Protection;


b. In the Configure XPIC page, Enable XPIC check boxes under both XPIC Pair 1
and XPIC Pair 2.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 18 of 31

Page 61 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

(11) Configuring Hierarchical Radio Link Bonding (hRLB)

Refer to the MOP “M-T-104: Ericsson Mini-Link 6600 Series setup” on the
Hierarchical Radio Link Bonding Groups tab:

(i) Create a 2X (2+2)hRLB group from two RLTs (2+2 RLB EQP)
(ii) Add member interfaces to the hRLB group

(12) Configuring Equipment Protection Switching

Refer to the MOP “M-T-104: Ericsson Mini-Link 6600 Series setup”

(i) Set the EQP switching mechanism mode to: Auto


(ii) Set MMU units that are connected to the Main antenna to be active in the EQP
configuration.

(13) Refer to Bulletin M-T-104 Ericsson Mini-Link 6600 Series and Bulletin T-T-064
Microwave Radio Testing, complete successfully all the required Acceptance tests for
the newly installed ML6363_ML6692 8GHz - 296 Mbps (4+4) SD XPIC radio system
between C0368 CHALK RIVER and C0414 PEMBROKER. Repeat any necessary
acceptance tests in the ML6363_ML6692 8GHz- 296 Mbps (4+4) SD XPIC system
should the test results fail.

(14) After commissioning the complete ML6363_ML6692 8GHz -4 x 296 Mbps (4+4)
system for normal operation, put the system into service.

(15) After successful traffic cut over to the new ML6363_ML6692 8GHz – 4 x 296 Mbps
(4+4) XPIC hop, decommission and remove existing (1+1) SDIV RAU2X 8GHz ODU,
remove existing ANT01.87/8HX antenna, flex twist waveguides, LDF2-50 cables,
indoor AMM6P chassis and its ancillary equipment, and return them to warehouse for
future purposes.

(16) Forward all testing and commissioning results to Transmission Engineering.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 19 of 31

Page 62 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

4.2.1 System Calculations

Path Calculation – Normal operation (RTPC)


C0368 CHALK RIVER C0414 PEMBROKE
Latitude 46 00 26.22 N 45 49 07.40 N
Longitude 077 25 49.07 W 077 09 15.69 W
True azimuth (°) 134.29 314.49
Vertical angle (°) -0.06 -0.14
Elevation (m) 152.00 151.00
Antenna model HPX8-71W (TR) HPX8-71W (TR)
Antenna file name 2825a 2825a
Antenna gain (dBi) 42.90 42.90
Antenna height (m) 75.00 96.10
Orientation loss (dB) 0.00 0.00
TX line model SXK 111 5095/2 SXK 111 5095/2
TX line unit loss (dB/100 m) 33.33 33.33
TX line length (m) 0.90 0.90
TX line loss (dB) 0.30 0.30
Connector loss (dB) 0.50 0.50
Miscellaneous loss (dB) 0.50 0.50
Circulator branching loss (dB) 3.50 3.50
Antenna model USX6-7W (DR) USX6-7W (DR)
Antenna file name 7374 7374
Antenna gain (dBi) 40.60 40.60
Antenna height (m) 61.00 78.40
Orientation loss (dB) 0.00 0.00
TX line model SXK 111 5095/2 SXK 111 5095/2
TX line unit loss (dB/100 m) 33.33 33.33
TX line length (m) 0.90 0.90
TX line loss (dB) 0.30 0.30
Connector loss (dB) 0.50 0.50
Diversity RX circulator loss (dB) 3.50 3.50
Other diversity RX loss (dB) 0.50 0.50
Frequency (MHz) 8025.00
Polarization Horizontal
Path length (km) 29.96
Free space loss (dB) 140.09
Atmospheric absorption loss (dB) 0.32
Main net path loss (dB) 64.20 64.20

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 20 of 31

Page 63 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

C0368 CHALK RIVER C0414 PEMBROKE


Diversity net path loss (dB) 66.50 66.50
Radio model 6608/63AAA/030/04kL/F7B 6608/63AAA/030/04kL/F7B
Radio file name eri_6608_63aaa_030_04kl_f7b eri_6608_63aaa_030_04kl_f7b
TX power (dBm) 27.00 27.00
Emission designator 27M4D7W 27M4D7W
EIRP (dBm) 65.10 65.10
TX channel assignments 7860.00H 8160.00H
7860.00V 8160.00V
7890.00H 8190.00H
7890.00V 8190.00V
RX threshold criteria BER 1e-6 BER 1e-6
RX threshold level (dBm) -54.00 -54.00
Main receive signal (dBm) -37.20 -37.20
Diversity receive signal (dBm) -39.50 -39.50
Thermal fade margin (dB) 16.80 16.80
XPD fade margin - multipath (dB) 24.47 24.47
Flat fade margin - multipath (dB) 16.11 16.11
Dispersive fade margin (dB) 47.70 47.70
Dispersive fade occurrence factor 2.00
Effective fade margin (dB) 16.10 16.10
Climatic factor 1.50
Terrain roughness (m) 10.16
C factor 2.54
Average annual temperature (°C) 3.78
Fade occurrence factor (Po) 3.291E-001
SD improvement factor 1.53 2.45
Worst month multipath availability (%) 99.47333 99.67050
Worst month multipath unavailability (sec) 13840.85 8659.14
Annual multipath availability (%) 99.89780 99.93606
Annual multipath unavailability (sec) 32229.74 20163.65
Annual 2 way multipath availability (%) 99.83386
Annual 2 way multipath unavailability (sec) 52393.39
Polarization Horizontal
Rain region Ottawa, Ontario
Rain rate (mm/hr) 79.74
Flat fade margin - rain (dB) 14.89
Rain attenuation (dB) 14.86

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 21 of 31

Page 64 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

C0368 CHALK RIVER C0414 PEMBROKE


Annual rain availability (%) 99.99785
Annual rain unavailability (min) 11.32
Annual rain + multipath availability (%) 99.83171
Annual rain + multipath unavailability (min) 884.54

Multipath fading method - Vigants - Barnett


Rain fading method - Crane

Note:
1. Each radio system must be provisioned for ML6692 4DE (296Mbps) with 4096 QAM Light
modulation and 30MHz bandwidth.
2. This is configured for RTPC with a target RSL -37.20 dBm Main, and -39.50 dBm m for
Diversity.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 22 of 31

Page 65 of 74 C0368-EI-2502-504-1-MW1-A
Engineering Design Specification

4.2.2 Physical Network Connections


C0368 CHALK RIVER

Re-use existing HPX8-71W main antenna at 75m AGL


Azimuth = 134.29°, facing C0414 PEMBROKER
Install 4 x ML6363 ODUs with two IPS3 Sym. splitters
and four (4) LDF4-50 cables close to the HPX8-71W
antenna.

Remove existing ANT01.87/8HX antenna at 64.6m AGL


Azimuth = 134.29°, facing C0414 PEMBROKER.
Decommission the existing 1+1 RAU2X ODUs along with
flex twist waveguides and LDF2-50 Cables.

Install new USX6-7W diversity antenna with additional


inboard side strut on to the tower at 61m AGL, Azimuth =
134.29°, facing C0414 PEMBROKER.
Install 4 x ML6363 ODUs with two IPS3 Sym. splitters and
four (4) LDF4-50 cables close to the USX6-7W antenna.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 23 of 31

Page 66 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

C0414 PEMBROKE
Re-use existing antenna HPX8-71W main antenna at 96.1m, Azimuth =
314.49°, facing C0368 CHALK RIVER
Install 4 x ML6363 ODUs with two IPS3 Sym. splitters and four (4) LDF4-50
cables close to the HPX8-71W antenna.

Install new USX6-7W diversity antenna with additional inboard side strut on
to the tower at 78.4m AGL, Azimuth = 314.49°, facing C0368 CHALK RIVER
Install 4 x ML6363 ODUs with two IPS3 Sym. splitters and four (4) LDF4-50
cables close to the USX6-7W antenna.

Remove existing ANT01.87/8HX antenna at 72.8m AGL Azimuth = 314.49°,


facing C0368 CHALK RIVER

Decommission the existing 1+1 RAU2X ODUs along with flex twist
waveguides and LDF2-50 Cables.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 24 of 31

Page 67 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

C0414 PEMBROKE

Re-use existing antenna HPX8-71W main antenna at 96.1m, Azimuth =


314.49°, facing C0368 CHALK RIVER
Install 4 x ML6363 ODUs with two IPS3 Sym. splitters and four (4) LDF4-50
cables close to the HPX8-71W antenna.

Install new USX6-7W diversity antenna with additional inboard side strut
on to the tower at 78.4m AGL, Azimuth = 314.49°, facing C0368 CHALK
RIVER
Install 4 x ML6363 ODUs with two IPS3 Sym. splitters and four (4) LDF4-
50 cables close to the USX6-7W antenna.

Remove existing ANT01.87/8HX antenna at 72.8m AGL Azimuth = 314.49°,


facing C0368 CHALK RIVER

Decommission the existing 1+1 RAU2X ODUs along with flex twist
waveguides and LDF2-50 Cables.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 25 of 31

Page 68 of 74 C0368-EI-2502-504-1-MW1-A
Engineering Design Specification

4.3 Configuration Details

Figure 1 Dual Polarized (4+4) SD XPIC/CCDP Schematic Installation Diagram

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 26 of
31

Page 69 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

Figure 2 Interconnected Slot Positions in ML6692 Enclosure

Figure 3 2+2 RLB EQP Configuration Block Diagram

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 27 of 31

Page 70 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

Figure 4 2x (2+2) hRLB Hierarchical RLB Configuration with Four MMU 1002 Modems

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 28 of 31

Page 71 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

4.4 End to End Impact Assessment

4.4.1 Impact Classification

Service Impact (None, Degraded, Outage)*: None


Network Impact (None, Degraded, Threatened, Outage)*: None
Customer Impact (Small, Medium, Large, Extensive)*: Small
Project Complexity (Low, Medium, High) Low

Note: * - See “Service Management Process Policy” for the definitions of Service, Network, and Customer Impact.

Involves/impacts single platform and/or network and


Impact is well understood and known and/or
Low Unexpected outcome of changes cannot result in a customer impacting outage.
Project Impacts multiple platforms and/or networks and/or
Complexity Potential for implementation failure exists.
Assessment Medium Unexpected outcome of changes may result in service degradation or minor service outage.
Involves changes on and impacts multiple platforms or networks and/or
High potential for implementation failure exists.
High Unexpected outcome of changes may result in a major, severe or critical service outage.

<This section is used to identify if a detailed impact assessment is required Yes or No.>
Yes No

4.5 Technical Pre-requisites


N/A
4.6 Testing and Field Acceptance

4.6.1 Testing to be executed

Refer to Bulletin ETAC MOPS:

1) 1) M-T-091 for Ericsson Mini-Link 6352 Setup.


2) 2) M-T-104 Ericsson Mini-Link 6600 Series setup.
3) 3) T-T-064 Microwave Radio Testing.
4) 4) T-T-136 Ericsson Mini-Multiband Booster Setup.
5) 5) T-T-138 Multiband Booster Setup with ML6352 &
MLTN.

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 29 of 31

Page 72 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

5.0 Execution section

5.1 Timing
Customer Requested
Due Date

Anticipated
Completion Date

5.2 Project Dependencies


Project # Project Name Dependency

X.#######.##

X.#######.##

X.#######.##

X.#######.##

X.#######.##

5.2.1 Project Pre-requisites (N/A)

5.2.2 Project Co-requisites (NIL)

5.2.3 Dependent or Related Projects (NIL)

5.3 Migration, Decommissioning and Redeployment Activities

N/A

6. 0 Functional Area and Responsibility

Functional Area Responsibility


Civil Eng.  Release of CWO

Equip. Eng.  Release of IWO and PWO

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 30 of 31

Page 73 of 74 C0368-EI-2502-504-1-MW1-A
Revision Number: 1.0
Engineering Design Specification Revision Date:
Original Release Date: November,13, 2021

7.0 Recommended Training

N/A

8.0 Reference Documents

8.1 Ericsson ML6363, ML6692 and Antenna Installation and Operational Manual
and MOPs

1) Bulletin M-T-091 for Ericsson Mini-Link 6352 Setup.


2) Bulletin M-T-104 Ericsson Mini-Link 6600 Series setup.
3) Bulletin T-T-064 Microwave Radio Testing.
4) Bulletin T-T-136 Ericsson Mini-Multiband Booster Setup.
5) Bulletin T-T-138 Multiband Booster Setup with ML6352 & MLTN.
6) Ericsson’s ML6363 (Mini-Link 6600 Outdoor Installation).
7) Ericsson’s ML6692 (Indoor Installation).
8) Aligning on Antenna Mini-Link 6600.
9) Commscope Path-Alignment-Cross-Polarization-Parabolic-Antennas TP-108827-
EN (02/17)

9.0 Abbreviations and Acronyms

Figures and Tables

Figure 1 Dual Polarized (4+4) SD XPIC/CCDP Schematic Installation Diagram


Figure 2 Interconnected Slot Positions in ML 6692 Enclosure
Figure 3 2+2 RLB EQP Configuration Block Diagram
Figure 4 2 x (2+2) hRLB Hierarchical RLB Configuration with Four MMU 1002 Modems

Proprietary and Confidential -  Rogers Communications Inc. All rights reserved Page 31 of 31

Page 74 of 74 C0368-EI-2502-504-1-MW1-A