Mk10E
ATLAS – Class 0.5S and Class 1
Key Features
Mk10E
ATLAS - Class 0.5S and Class 1
262mm (H)
95mm (D)
Weight: 2kg
Standards and Compliance • Option for external for backup • Supports Advanced Demand • Up to 7 independent security levels
• Option for UPS battery Management (ADM) with prioritised • Up to 6 individual users
• Class 0.5S and Class 1
• Option for additional Supercap (72 hours) rules • AES128 bit encryption
• IEC 62052-11, 62053-21, 62053-22,
• Backup time: 10 years without power • AMI ready
62053-23
(Lithium Battery) • Up to 32 channels and 4 independent
• AS 62052.11, 62053.21, 62053.22,
surveys
62053.23
Real-time Clock • Intervals programmable from 1 to 60 Communications
• NMI M6
minutes
• Accuracy (internal) within 15 seconds • Up to 3 independently working
per month at 23ºC • Energy, instantaneous readings, communication ports:
Measurement
pulsing input as channel sources
• 3 phase 3 wire - Optical port: FLAG (IEC 62056-21) or
• Ability to store average/minimum/ ANSI Type 2 (ANSI C12.18)
• 3 phase 4 wire maximum values for interval duration
Data Memory - RS-232 with modem power supply
• Option for neutral current measurement
• 2 MB of non-volatile memory (It supports most modems in the
Time of Use market)
Voltage • Up to 8 rates plus unified rate
Display - RS-485 multi-drop (2 or 4-wire RJ45
• Nominal voltage: 57.7V – 240V • Up to 32 separate import and export or 2-wire screw terminal)
• Large 7 segment alphanumeric display
• Operating range: 52V – 290V registers • UDP/IP GPRS/PPP capable
with 10.7mm x 6.67mm digit size
• Withstand: Up to 290V • Daily, weekly, monthly, yearly and • Compatible with MV-90™
• *Large 14 segment alphanumeric
• Burden: IEC 62053-61 compliant display with 10.5mm x 5.1mm digit size special days • Supports Function Based Setup
• Up to 60 user-defined screens of any • Up to 200 programmable special days
Auxiliary Supply Options • Up to 61 previous billing periods plus
meter parameter Protocol
• 57.7V - 240V Auxiliary Supply • Definable enunciators billing totals
• EDMI command line
• Battery UPS • Display available without main power • Block or rolling maximum demand
• DLMS
• LED Backlight Option • Time of maximum demand
• MODBUS
Current • Energy, pulsing inputs
• CT range: 1/4A, 1/10A, 5/6A, 5/10A,
5/20A Calendar
• CT limit: 20 x Imax for 0.5 seconds • Supports Daylight Saving time
Measured Values Software
• WC range: 5/100A, 10/100A • Supports Gregorian or Persian calendars
• 3 elements 4 quadrants • EDMI EziView software available for
• Burden: <0.5VA/phase
• Import/Export/Absolute Wh, varh and meter programming and reading
VAh Tamper Detection and Alarms (Windows® compatible)
Frequency • Fundamental Wh • Provision for sealing with conventional •
EDMI MultiDrive software available for
• 45Hz - 65Hz • Per quadrant Wh, varh and VAh wire or plastic seals large scale AMI and AMR solutions
• Phase A,B,C and Total • Bypassing current and reverse current (Windows® compatible)
Inputs/Outputs Configuration detection • Supported by many popular third-party
• W, var, VA, Vrms, Irms
• Up to 4 independently isolated I/O • Advanced tamper detection and multi-vendor AMR systems
• Power factor, frequency, phasor angles
• Options include: Passive/Active logging
• Supports ripple control/AFLC
inputs, S0/BOSFET/Relay outputs • Pre-programmed alarms for meter self-
• Passive input voltage: 5V, 12V, 48V, check
Power Quality Indication • Alarms trigger LEDs, enunciators, relay
110V, 240V Environmental
• Total Harmonic Distortion (THD) outputs or communications event
• Active input voltage: 12V (common • Specified operating range:
• Unbalance (sequence components) • Alarms are stored in event logs
ground) -25˚C to +60˚C
• Option for live waveform display • Option for fixed-threshold magnetic
• S0 Output: 27V, 27mA maximum • Operating range limit:
• Sag/Swell tamper detection -40˚C to +70˚C
• BOSFET output: 240V, 100mA maximum
- 5 Cycle resolution • *Option for high-sensitivity 3D • Storage range limit:
• Relay output: 240V, 2A
- Records time/date/phase/duration/ magnetic tamper detection with -40˚C to +80˚C
• 2 Programmable LED indicators
average and worst excursion configurable threshold
• Programmable output pulse width: 1ms • Relative humidity:
- Programmable trigger levels • Source impedance monitoring
to 100ms Up to 95% non-condensing for 30 days
• Ingress protection: IP54
Load Survey/Profile Security
Battery • Protective Class II
• Over 5000 days storage (2 channels, • Multi-level security (username and
• Internal battery • Surge Test: 5kV
30-minute intervals) password including encrypted log-in)
• Impulse Test: 12kV