You are on page 1of 29

Date: 23-01-2024

RefNo: JEF/DEL/CLP/DPK/R0/24267/2023-2024

Fireemedysystems

No. N1, 2nd Floor, South Extension -1, NDSE Part-1, Delhi

Kind Attention: Mr. Naresh

Subject : Our offer against your enquiry dated 23-01-2024 for Lightening Protection System as per IS/IEC 62305

We thank you for your enquiry & are pleased to submit our Techno Commercial offer comprising the following :

(1) Product Catalogue

(2) Commercial Offer

We trust you will fnd our offer in line with your requirement & look forward to receive your valued order. In case you have any

Thanking you

Yours faithfully

For Jef Techno Solutions


Deepak Kumar Lashkar

Business Development Manager - Products

Mobile: 9818954367

Email ID: deepak.kumar@jeftechno.com


er IS/IEC 62305

g the following :

ed order. In case you have any further queries, please feel free to contact us.
SL.No PartCode

1 JIM04A.JIAT11.

2 SPC5B.

3 JIDC01.

4 JICL59.

5 JIAC23.

6 JISP01.

7 JISP05.
8 JISP01.

9 JISP02.

10 JIDC01.

11 JICL59.

12 TL06.

13 DW1.

14 JICL08.

15 U01.
16 JIAT11.

GENERAL TERMS & CONDITIONS :

1 Taxes : GST Applicable as per relevant Act at the time of dispatches ( Current Rate of GST is 18% S/C-GST or IGST a

2 Price Basis: Ex- warehouse Hosur

3 Delivery : Within 4 - 6 weeks from the date of receipt of Confirmed Purchase Order and approval of drawings whe

4 Freight : Included in the price

5 Validity : Valid for 1 month from date of offer.


6 Payment : 100% Advance..

7 Guarantee : The JEF LPS SYSTEM offered by us are guaranteed for 18 Months from the date of supply provided it i

COMMERCIAL TERMS & CONDITIONS :

1 Prices are for quoted items & quantity, Should there be any change in items and quantity due to variation in desig

2 Our offer is limited to supply of the items quoted only.

3 The Lightning Protection System is not meant to protect the equipments housed in the building. In case you wish

4 The Individual Earth Pit resistance will depend on soil resistivity at site. For the purpose of acceptance, the measu
5 The construction of LPS and its accessories shall be as per our standard design which meets the guidelines given in
Description

MAST 34mm dia 3 mtr long- Cold Galvanised for Side Mounting without Base Plate;Supply of Vertical Air Termination Solid Al

Holder -GI-C-type for fixing 34mm Dia mast on masonary Wall-side mounting

Supply of 8 mm dia solid Aluminium Conductor tested as per IEC 62561- 2 conducted in the Govt. aggregated thirty party labo

Polyamide Holder for fixing 8mm dia Conductor

Concrete block for Conductor fixing- 100x100x50mm thick

Supply of Al. Straight Splicers for 8mm and 10 mm Conductor to meet the requirement of IS IEC 62305 tested for conditioning

Supply of Expansion Piece without connector to compensate the expansion and contraction of Solid Round Al. Conductor duri
Supply of Al. Straight Splicers for 8mm and 10 mm Conductor to meet the requirement of IS IEC 62305 tested for conditioning

Supply of Cross splicer should be ttested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10

Supply of 8 mm dia solid Aluminium Conductor tested as per IEC 62561- 2 conducted in the Govt. aggregated thirty party labo

Polyamide Holder for fixing 8mm dia Conductor

Each down-conductor should be provided with a test link in order to disconnect the earth termination system for enabling me

Suply of 25 X 6 mm GI strip from AL Conductor to the earth pit station and further the same strip shall be used for interconnec

Holder -GI for fixing 25 x 6 mm GI Strip

Electromechanical Lightning event counter in IP 65 enclosure


Supply of Vertical Air Termination Solid Aluminium with base- 16 mm dia and 1000 mm long. Air Terminal Base should be teste

per relevant Act at the time of dispatches ( Current Rate of GST is 18% S/C-GST or IGST as the case may be ) shall be extra.

e Hosur

eks from the date of receipt of Confirmed Purchase Order and approval of drawings wherever applicable, subject to 100% Work Front Clea

rice

h from date of offer.


..

YSTEM offered by us are guaranteed for 18 Months from the date of supply provided it is installed as per the guidelines given in the Stand

ms & quantity, Should there be any change in items and quantity due to variation in design / site conditionetc, the same shall be supplied a

ply of the items quoted only.

System is not meant to protect the equipments housed in the building. In case you wish to protect the equipment against damages due to

esistance will depend on soil resistivity at site. For the purpose of acceptance, the measured resistance value shall be governed by the form
nd its accessories shall be as per our standard design which meets the guidelines given in IS/IEC 62305.
HSN Code QuantitUnit Supply Price

76109090 22 Sets 0

0 66 Nos 0

73121010 2752 Mtr 0

0 2752 Nos 0

0 52 Nos 0

76109090 79 Nos 0

76169990 31 Nos 0
76109090 62 Nos 0

0 97 Nos 0

73121010 1713 Mtr 0

0 1713 Nos 0

0 49 Nos 0

72122090 1552 Mtr 0

76109090 1552 Nos 0

90291090 49 Nos 0
76109090 30 Nos 0
Amount

91300

19800

198144

49536

5460

12640

3720
9920

18430

123336

30834

14700

325920

31040

264600
31500
Image