This chapter details that using a portable PC monitor Repeater in the scene, Matters
should be noted that in the operation has been given to guide users to the correct operation of
the system.
Operating System Features:
The software provides debugging and monitoring capabilities for installation of Repeater,
the operating system running on PC WindowsXP/Win7 window, use PC serial port (COM port
optional) communicate directly with Repeater.
The software has a parameter configuration, parameter query. This software is a visual
user interface, friendly interface, simple operation, stable and reliable.
After installation is complete, power on the Repeater, Repeater into a power initial
program, can not operate the equipment, after about a minute, Repeater into operation.
Enter the information in the corresponding section of “site information”, As shown in Figure
1
NMS System
3-5, for example:
Site name: place1
Site number: 00000000 (all repeater factory settings are 00000000)
Telephone number: 13950(Enter Repeater SIM Card number for remoter monitor, if not
remoter monitor can enter any number)
Device type: Channel selective repeater
Device IP address: 192.168.1.121 (Enter any IP address, must not be blank for Ethernet
monitor. If not Ethernet monitor you enter any number)
Device IP port: 5000(Enter any port number for Ethernet monitor. If not Ethernet monitor you
enter any number)
Remote unit number: 1
Click “Save” button to save site information. Double click on this site(As shown by the
arrow in Figure 3-6)Enter the parameter configuration interface.
Please Use the Annex assigned cable connect the Device RS232 port and PC RS232
port. Then switch on the Repeater power and wait about 1 minute. And entering parameter
configuration interface, first query the site number to detect PC and repeater
communication status. After everything is normal you can query the repeater work status
and set it work parameter through the software.
Select “Network parameter” tab, check the “Site number” check box only, Click the "query"
button, it should be able to successfully query the Site NO. within 30 seconds, if not
successfully query, then click "Query" button then wait 30 seconds, if three consecutive times
without success, wire connection problem, after exclusion of this problem and try again should
succeed. Testing Donor unit, select the host icon(place1) in the upper left side software
2
NMS System
interface, testing Remote unit, select the remote icon(remote1) in the upper left side software
interface.
After querying number successfully, detect the downlink input power. As shown in Figure
3-9.
Figure 3-9
Select “working parameter” tab, select the check box of the “DL input power”, then click
"Query" button, it should be able to return to the downlink input power value in the 30 seconds.
The value should >-85dBm. (Preferably> -60dBm). When using instruments to measure the
local source signal strength> -85dBm, if this measure value <-85dBm maybe have the following
problems: 1. Donor antenna is not aligned with the direction of the base of the station . Please
adjust the direction of the donor antenna, aligned with the base station . 2.Donnor antenna is
no good contact. Through the instrument or software testing Donnor antenna ‘s VSWR if
3
NMS System
normal. Exclude this possible. 3. The length of the feeder between the antenna and the device
is too long. The proposal does not exceed 30 m length.
Select the check box of the “DL output power”, then click "Query" button, it should be able
to return to the downlink output power value in the 30 seconds. As shown in figure 3-10, The
unit of query result is: dBm. The value should >30dBm. When the input power>-60dBm, if the
detected value <30, maybe have the following problems: Have set ATT too much,please
release ATT.
4
NMS System
Figure 3-11
5
NMS System
Figure 3-13
Note:
There are five groups of Query/Set number, These five groups of numbers can query
and set the operating parameters and state of the Repeater, The five groups can be all
set, you can also set only a few of them. Alarm information will report to the “Report Tel
number” when the equipment has alarm information. “Query/Set number” and “Report
Tel number” can be the same. The SIM cards of above numbers must be inserted in the
SMS MODEM supplied by Our Company. The SMS MODEM must be connected with our
monitor center software before being used normally.
3. When building new site, shall ensure that "the monitoring center software" site number,
Site Device number, Telephone number are the same as these parameters in repeater, if they
are not consistent, it will lead to communication failure.
4. The completion of the above operations, the monitoring center can perform remote query,
setting and alarm test for the repeater.
6
NMS System
Figure 3-14
The following, you can query the repeater working state and set repeater parameter
through the method introduced above.
Note: According to the Remote monitor, because the message response required
longer time, So the operation response speed will slow than a local monitoring, waiting 50
seconds from the start time of the operation, if not normal receives the response of
equipment, the software will prompt that “operation failed”, need to re-operation. If unable
to normal operation all the time, please check that the two SMS MODEM of equipment and
the monitor center are working properly, the communication parameters are configured
properly, and the communication parameters are configured properly?