Professional Documents
Culture Documents
AT
PLOT E,DELTA STATE COMMERCIAL HOUSIN
JUNIOR STAFF QUARTERS CORE AREA
OSHIMILI SOUTH LGA,DELTA STAT
FOR
SHARPTON ENTERPRISES
Consulting Engineers
CONSULTANTS
GNAD ENGINEERING CONSULT
NO 16 DADA ATANRANSE, AGRIC BUS STOP,
IKORODU ROAD,LAGOS STATE.
PHONE : (+234)(08039227474)
E-mail :gnadengineeringconsult1@gmail.com
Web-site @ www.Gnad.com.ng
NOTE'S.
1.0GENERAL 2.0 3.0 4.0BLOCK WORK 1. DRAWING MUST NOT BE SCALED DIRECTLY, AND IF ANY AMBIGUITY, THE
CONSULTANT ENGINEER MUST BE SEEN WITHOUT ANY ALTERATION.
1.1 WORK TO FIGURED DIMENSIONS ONLY
2.1 THE MATERIALS AND WORKMANSHIP 2.8 ALL CONSTRUCTION JOINT POSITIONS
3.1 ALL STRUCTURAL STEEL WORK4.1 HOLLOW BLOCK WALLS BELOW 2. WRITTEN DIMENSION'S TO BE TAKEN IN PREFERENCE.
ALL DIMENSIONS ARE IN METRES FOR CONCRETE WORKS GENERALLYSHALL BE APPROVED BY THE SHALL BE MILD STEEL TO BS 4360GROUND SLAB LEVEL SHALL BE3. DIMENSION'S TO BE CHECKED ON SITE.
AND MILLIMETRES UNLESS NOTED SHALL BE IN ACCORDANCE WITH ENGINEER PRIOR TO CASTING GRADE 43A EXCEPT HOLLOW 4. DIMENSION'S ARE TAKEN TO GRIDLINE'S AND STRUCTURAL SURFACE'S
FILLED WITH MASS CONCRETE. NOT TO FINISHED SURFACE'S EXCEPT WHERE OTHERWISE STATED.
OTHERWISE AND THE DIMENSIONS BRITISH STANDARDS BS8110, SECTIONS WHICH SHALL COMPLYBACK FILLING SHALL BE CARRIED5. THE DESIGN ENGINEER SHALL NOT BE RESPONSIBLE FOR THE
SHALL BE CHECKED BY THE BS 5328,BS8077 AND RELATED 2.9 SAMPLES OF ALL CONCRETE WITH GRADE 43C OUT SIMULTANEOUSLY ON BOTH FOUNDATIONS DESIGN EXCEPT THE CLIENT PROVIDE HIM WITH SOIL
CONTRACTOR CODES MATERIAL CONSTITUENTS AND REIN- SIDES TEST FOR CONFIRMATION OF FOUNDATION DEDIGN.
2.2 INCASE OF CONFLICT THE INFORMATION FORCEMENT SHALL BE TESTED IN3.2WELDING FABRICATION AND 6. CONSULTING ENGINEERS NOT RESPONSIBLE FOR ANY JOB NOT
1.2 ALL DRAWINGS SHALL BE READ ONIN THIS DRAWING SHALL AN APPROVED INDEPENDENT ERECTION OF STRUCTURAL STEEL42 THE WALL THICKNESS OF THESUPERVISED BY THEM.
CONJUNCTION WITH ARCHITECTURALTAKE PRECEDENCE OVER THE TESTING LABORATORY TO ASCERTAIN
WORK SHALL CONFORM TO BLOCK SHOULD NOT BE MORE
DRAWINGS, OTHER STRUCTURAL ABOVE MENTIONED CODES AND ANY THEIR QUALITIES. BS449 PART 2 OR BS5950 THAN 25mm
DRAWINGS AND RELEVANT GENERAL CONCRETE SPECIFICATION DETAILS OF TESTS TO BE CARRIED
SPECIALIST DRAWINGS IN THE BOQ OUT SHALL BE AS GIVEN BY THE3.3 UNLESS WHERE OTHERWISE NOTED
4.3 THE MINIMUM CRUSHING STRENGTH
THE ARCHITECT OR THE ENGINEER ENGINEER DEPENDING ON THE ALL BOLTS SHALL BE BLACK BOLTSOF THE HOLLOW BLOCKS SHALL BE
2.3 OF
SHALL BE NOTIFIED IMMEDIATELY SOURCES OF THE MATERIALS. TO BS 4190 AND WASHERS TO 2.0N/mm2 OF GROSS AREA OF
ANY DISCREPANCY IN THE DRAWINGS BS4320 SHALL BE PROVIDED FOR THE BLOCK AT 28 DAYS.
SHALL BE OF WATER TIGHT CONST- ALL BOLTS.
2.10 ADMIXTURES MAY BE USED BY THE
RUCTION AND DESIGNED MIX
1.3 ALL TOP SOIL UNDER FLOOR SLABS CONTRACTOR ONLY IF APPROVED BY 4.4 TIES SHALL BE PROVIDED BETWEEN
SHALL BE REMOVED. 150mm WELLGRADE 25MAXMUM AGGREGATE 3.4 ALL WELDS ARE TO BE 6mm FILLET
THE ENGINEER, TECHNICAL INFOR- BLOCK WALLS AND COLUMNS/
COMPACTED NATURALLY OCCURRING SIZE20mmMINIMUM CEMENT MATION RELATING TO THE WELDS AND CONTINUOUS UNLESS STANCHIONS. THE TIES WHICH
HARDCORE MATERIAL OR ROCK CONTENT 310Kg/m³ AND MAXIMUM ADMIXTURE SHALL BE SUPPLIED WHERE OTHERWISE INDICATED. SHALL BE 6mm BAR STRAPS
LATERITE SHALL BE PROVIDED WATER CEMENT RATIO 0.55 OF AND THE QUANTITY AND METHOD OF 700mm LONG INTO THE BLOCK WALL
UNDER ALL GROUND BEARING 3.5 THE FIRST BAY OF ERECTED STEEL
APPLICATION SHALL BE IN ACCOR- SHALL BE PROVIDED AT EVERY
SLAB AND WELL COMPACTED. 2.4 CONCRETE FOR ALL STRUCTURAL DANCE WITH THE MANUFACTURER'S WORK SHALL BE TO LINE AND COURSE.
SELECTED FILL OR LEAN CONC. ELEMENTS INSTRUCTIONS. LEVEL AND HELD BY MEANS OF
SHALL BE USED TO MAKE UP --------------------- TEMPORARY BRACING BEFORE 4.5 MAXIMUM FOUR HEIGHT FOR ALL
LEVELS WHERE NECESSARY, UNLESSSHALL BE OF DESIGNED MIX GRADE 2.11 MINIMUM COVER TO ALL REINFORFURTHER ERECTION SHALL CONTINUE.
FILLED BLOCK WALL SHALL BE
SPECIFIED OTHERWISE ON THE 25 MAXMUM AGGREGATE SIZE
DRAWING. CEMENT INCLUDING LINKS SHALL 2 COURSE
20mm
FILLING SHALL BE DONE IN LAYERS MINIMUM CEMENT
OF BE AS FOLLOWS- 3.6 ANTI-SAG RODS SHALL BE PROVIDED
150mm CONTENT 310Kg/m³ AND BEAMS, SLABS, STAIRS, AND AS SHOWN ON THE DRAWINGS. WHERE
MAXIMUM WATER CEMENT RATIO OF WALLS=25mm ANTI-SAG RODS ARE NOT SHOWN ON
0.55
1.4 WHERE BAD GROUND IS ENCOUNTERED COLUMNS=30mm THE DRAWING THEY SHALL BE PLACED
BELOW FOUNDATION LEVEL, PILE CAPS=75mm AT MID SPAN OF PURLINS OR TO PURLIN
2.5 BLINDING CONCRETE AND LEAN ALL WATER TIGHT
THE DIFFERENCE IN LEVEL BETWEEN MANUFACTURERS SPECIFICATION.
THE APPROVED BEARING STRATUM CONCRETE SHALL BE1:3:6(CEMENT:SAND MEMBERS =50mm
AND THE ORIGINAL LEVEL SHALL:COARSE
BE AGGREGATE) NOMINAL MIX ORMEMBERS IN CONTACT
ALL 3.7 ALL STEEL SURFACES IN CONTACT
MADE UP USING LEAN CONCRETEEQUIVALENT DESIGNED MIX. WITH EARTH=50mm WITH ALUMINUM SHEETING SHALL
LEVEL UNLESS NOTED OTHERWISE ON THE BE GIVEN TWO COATS OF AN APPROVED
1.5 EXTERNAL WALL FOOTINGS SHALL DRAWINGS BITUMASTIC PAINT BEFORE FIXING SHEETING
BE NOT LESS THAN 1 METRE 2.6 REINFORCEMENT DENOTED BY R
BELOW EITHER THE EXISTING SHALL BE MILD STEEL TO BS4449 3.8 ALL BOLTS IN TENSION SHOULD BE
2.12 THE FOLLOWING OTHER ABBREVIATIONS
GROUND LEVEL OR FINAL GROUND CHARACTERISTIC STRENGTH fy OFMAY BE APPLICABLE PROVIDED WITH EITHER DOUBLE
LEVEL 250N/mm² T=TOP, B&T= BOTTOM & TOP COILED SPRING WASHER OR LOCK
HIGH TENSILE REINFORCEMENT B= BOTTOM, B/T= BOTTOM, TOP, NUTS
1.6 DURING THE EXCAVATION FOR DENOTED
THE BY T SHALL BE IN NF= NEAR FACE
FOUNDATIONS, THE CONTRACTOR ACCORDANCE WITH BS4449 AND FF = FAR FACE
SHALL IN FORM THE ENGINEER BS 4461 AND WITH CHARACTERISTIC EF= EACH FACE
OF ANY DISCREPANCY BETWEEN THESTRENGTH fy OF 410N/mm OF= OUTER FACE
SOIL STRATA ENCOUNTERED AND EW= EACH WAY
THOSE GIVEN IN THE SUBSOIL2.7 IN WATERTIGHT CONSTRUCTION
REPORT, IF ANY ALL JOINT I THE CONCRETE
SHALL HAVE APPROVED WATERBARS
1.7 FOUNDATION WORKS GENERALLY AND ALL PIPE THROUGH WALLS
SHALL BE IN ACCORDANCE WITHAND SLAB SHALL HAVE APPROVED
BS8004 PUDDLE FLANGES.
DUE CARE SHALL BE EXERCISED BY
THE CONTRACTOR TO ENSURE THAT
THE WATER BARS ARE PROPERLY
JOINTED BY WELDING, AND
PROPERLY HELD IN POSITION
DURING CONCRETING
21100
I C9 C10
BT1 BT1 BT1
H C3 C11 C12
1475
C14 C15
C16 C17 C18 C19
G
BT2 BT1 BT1
12250
F C4 C5 A132 C21
A132 A132
1500
BT2 BT1
E
BT2 BT2 C22 C23
325 800
D BT1 BT1
C24 C25
C'' 285.0000
C26 C27
C'
A132
225 875 225 1515
A A
C BT1 BT2 BT2 BT1 BT1
A132 BT1
B' C29 C30 C6 C31 C32 C33
A C7 C39
BR REF No A132
Road level
300 1200
Compacted lateritic Soil Compacted lateritic Soil Compacted lateritic Soil
300
675 675 SECTION A-A 675 675 675 675 675 675 675
notes PROJECT SHEET TITLE
1 drawings not to be scaled 5 this drawing is copyright and must not be JOB TITLE CONSULTANTS
2 written dimensions to be taken in preference
3 dimensions are taken to grid lines and
reproduced without the written permision PROPOSED RESIDENTIAL DEVELOPMENTGNAD ENGINEERING CONSULT FOUNDATION LAYOUT AND SECTION
structural surfaces,not to finished surfaces
of bloomgate ltd.
FOR SHARPTON ENTERPRISES NO 16 DADA ATANRANSE, AGRIC BUS STOP, ENGINEER ENGR. GBADAMOSI SHEET NO.
4 any discrepancies between this drawing 5 authorisation for the use of these drawing revisions AT IKORODU ROAD,LAGOS STATE. DRAWN NURUDEEN
and others or the specification will be is deemed to be given after settlement of
PLOT E,DELTA STATE COMMERCIAL HOUSING SCHEME
brought to the attention of the
architects who alone will decide on final
professional fees. PHONE
JUNIOR STAFF QUARTERS CORE AREA ASABA, : (+234)(08039227474) CHECKED ENGR. O.O EGHWRUDJE
instruction E-mail :gnadengineeringconsult1@gmail.comSCALE DATE 01
item description initials date OSHIMILI SOUTH LGA,DELTA STATE. Web-site @ www.Gnad.com.ng 1 : 70 NOVEMBER,2021
T10 @ 175
T10 @ 175
T10 @ 175
T10 @ 175
800
800
LD
800
7-T16@200 C/C (B) 7-T16@200 C/C (B) 9-T16@200 C/C (B) 9-T16@200 C/C (B)
EL. 0.000
EL. 0.000 EL. 0.000 EL. 0.000
BOF
300
300
300
300
100 THK PCC 100 THK PCC 100THK PCC 100 THK PCC
T16@200 C/C (B) T16@200 C/C (B)
T16@200 C/C (B) T16@200 C/C (B)
1100 1100 1500 1500
2
9-T16@200 C/C (B)
1500
1100
1100
100 THK PCC 1500
100 THK PCC
2 4
FOOTING BT1- PLAN(25 NOS THUS) FOOTING BT2- PLAN(10 nos thus)
(SCALE 1:25)
(SCALE 1:25)
notes PROJECT SHEET TITLE
1 drawings not to be scaled 5 this drawing is copyright and must not be JOB TITLE CONSULTANTS
2 written dimensions to be taken in preference reproduced without the written permision PROPOSED RESIDENTIAL DEVELOPMENT GNAD ENGINEERING CONSULT COLUMN FOOTING DETAIL & SECTIONS
3 dimensions are taken to grid lines and
structural surfaces,not to finished surfaces
of bloomgate ltd. FOR SHARPTON ENTERPRISES NO 16 DADA ATANRANSE, AGRIC BUS STOP,
4 any discrepancies between this drawing 5 authorisation for the use of these drawing revisions AT ENGINEER ENGR. GBADAMOSI SHEET NO.
and others or the specification will be is deemed to be given after settlement of IKORODU
PLOT E,DELTA STATE COMMERCIAL HOUSING SCHEMEROAD,LAGOS STATE. DRAWN NURUDEEN
brought to the attention of the professional fees. PHONE : (+234)(08039227474) CHECKED ENGR. O.O EGHWRUDJE
architects who alone will decide on final
JUNIOR STAFF QUARTERS CORE AREA ASABA,
E-mail :gnadengineeringconsult1@gmail.comSCALE
instruction
3.6M
7.05M
225
225
225
225
225
225
225
T16 T16 T16 T16 T16 T16 T16
225 225 225 225 225 225 225
4-T16 4-T16 4-T16 4-T16 4-T16 4-T16 4-T16
C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM
0M
3.6M
225
225
225
225
225
225
225
225
T16 T16 T16 T16 T16 T16 T16 T16
225 225 225 225 225 225 225 225
4-T16 4-T16 4-T16 4-T16 4-T16 4-T16 4-T16 4-T16
COLUMN MARKED C1 C2 C3 C4 C5 C6 C7 C8
3.6M
TO
7.05M
C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM
0M
3.6M
225
225
225
225
225
225
225
225
T16 T16 T16 T16 T16 T16 T16 T16
225 225 225 225 225 225 225 225
4-T16 4-T16 4-T16 4-T16 4-T16 4-T16 4-T16 4-T16
item description initials date OSHIMILI SOUTH LGA,DELTA STATE. Web-site @ www.Gnad.com.ng 1 : 70
DATE
NOVEMBER,2021
03
3.6M
TO
7.05M
C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM
0M
3.6M
225
225
225
225
225
225
225
225
T16 T16 T16 T16 T16 T16 T16 T16
225 225 225 225 225 225 225 225
4-T16 4-T16 4-T16 4-T16 4-T16 4-T16 4-T16 4-T16
COLUMN MARKED C17 C18 C19 C20 C21 C22 C23 C24
3.6M
TO
7.05M
C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM
0M
3.6M
225
225
225
225
225
225
225
225
T16 T16 T16 T16 T16 T16 T16 T16
225 225 225 225 225 225 225 225
4-T16 4-T16 4-T16 4-T16 4-T16 4-T16 4-T16 4-T16
COLUMN MARKED C25 C26 C27 C28 C29 C30 C31 C32
item description initials date OSHIMILI SOUTH LGA,DELTA STATE. Web-site @ www.Gnad.com.ng 1 : 70
DATE
NOVEMBER,2021
04
C25 : Fe410 , COVER = 25MM
3.6M
LINKS
TO
T10 @ 175
7.05M
225
T16
225
4-T16
C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM
0M
3.6M
225
225
225
225
225
225
225
T16 T16 T16 T16 T16 T16 T16
225 225 225 225 225 225 225
4-T16 4-T16 4-T16 4-T16 4-T16 4-T16 4-T16
COLUMN MARKED C33 C34 C35 C36 C37 C38 C39 C40
C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM C25 : Fe410 , COVER = 25MM
3.6M
7.05M
225
225
225
225
225
T16 T16 T16 T16 T16
225 225 225 225 225
4-T16 4-T16 4-T16 4-T16 4-T16
0M
TO
3.6M
item description initials date OSHIMILI SOUTH LGA,DELTA STATE. Web-site @ www.Gnad.com.ng 1 : 70
DATE
NOVEMBER,2021
05
EL. 7.050
TOC
(1) 4-T16
EL. 7.050 2
1 1
TOC
@175 C/C
(2) T10
220
(1) 4-T16
(1) 4-T16
220
1 1
@175 C/C
2 (SCALE 1:25)
EL. 3.6m
380
E1
BOF
(1) 4-T16
(1) 4-T16
(1) 4-T16
220
2 1 1
1 1
SECTION 1-1 (C1-C7)
@175 C/C
@175 C/C
220
(2) T10
(1) 4-T16
(2) T10
(SCALE 1:25)
220
SECTION 1-1 (C8-C39)
(SCALE 1:25)
E1
E1
530
EL. 0
530
EL. 0
BOF
BOF
B58
C1 C2
B55
I' C8
B65
B4 B5
I C9 C10
B6 B7 B8
5
H
B7
C3 C11 C12
B54
B42
B48
B64
B69
2900
B72
G'''
B57
C13
B53
B40
B63
G
1525
B74
B16 B17
12250
B52
F
B43
B47
C4 C5 C21
B68
B39
B62
2625
B73
B18
E C22 C23
C24 C25
C'' B25 B26
B51
B56
B61
C26 C27C28
B66
1800
B71
C'
B41
C B
B27 B2876 B29 B30 B31
B45
B32
B' C29 C30 B7 C6 C31 C32 C33
7 C34 C35
1700
B50
B60
B B33 B34
B49
B35
B59
A' C36 C37
C38 B36 B37
A C7 C39
20500
S1
I' S2
I
(150THK)
H (150THK)
2900
G''' S5 S6
G'' S7 S8 S9
G' (150THK) (150THK) (150THK)
(150THK)
(150THK)
G
1525
12250
S12 S13 S14
F S15
2625
(150THK)
E
D S16 S17 S18
S19
C''
(150THK) (150THK) (150THK)
1800
C' (150THK) S22
C
B' S25(150THK)
1700
B
A' (150THK)
A
20500
1 2 4 5 2 4 5 10 10' 4 6 8
8 9 11 12
225 225 225 225 225 225 225 225 225 225 225 225
600 3225 3825 600 3225 3825 455 2625 4450
912.5
2-T16 3-T20 3-T16 2-T16 3-T16
5 8 2 4 4 9 10 10' 2 5
14 19 20 21
225 225 225 225 225 225 225 225 225 225
7075 600 3225 3825 600 3825 455 600 7050
1827.5 1827.5
3-T16 3-T20
2-T16 2-T16 2-T16 2-T16
19 20 21
C22 14 C23 C24 C25 C26 C27 C28
B19:225x450 B20:225x450 B21:225x450 B22:225x450 B23:225x450 B24:225x450 B25:225x450 B26:225x450
B18:225x450 (SCALE: H = 1:50 / V = 1:50)
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
(SCALE: H = 1:50 / V = 1:50)
225 225 225 225 225 225 225 225 225 225 225
3-T16
3-T16 3-T16
2-T16 3-T16 2-T16 3-T20 2-T16 3-T16 2-T16 2-T16 2-T16
2-T16 2-T16
450
450
450
450
450
450
450
450
450
450
450
STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10
2-T16 2-T16 2-T16 2-T16 2-T16 2-T16 2-T16 2-T16 2-T16 2-T16 2-T16
SECTION 1-1 SECTION 2-2 SECTION 4-4 SECTION 8-8 SECTION 9-9 SECTION 11-11 SECTION 12-12 SECTION 14-14 SECTION 19-19 SECTION 20-20 SECTION 21-21
(SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25)
item description initials date OSHIMILI SOUTH LGA,DELTA STATE. Web-site @ www.Gnad.com.ng 1 : 70
DATE
NOVEMBER,2021
09
5 6 8 9 9' 10 9 9'
22 23 24 25 2 26 3 27 5 28
A
225 225 225 225 225 225 225 225 225 225 225 225
2625 630 2324 2275 1550 2275 1725 2625 2700
912.5
2-T16 2-T20 2-T16 2-T16 3-T16 2-T16 3-T20
5 29 7' 30
C' D G B 31 D 32 I D 33 G 34
A' B
225 225 225 225 225 225 225 225 225 225 225 225 225
4450 2625 610 3825 590 3225 3526 3825 455
957.5
3-T16 3-T16 3-T20 2-T16 3-T16 2-T16 2-T16
A C E G G''' I E
A' 35 C' D G I 13
A' B 36 37
225 225 225 225 225 225 225 225 225 225 225 225 225 225 225
2840 610 3825 3526 455 1700 2926 3025 1426 2100 1074 2926
2-T16 2-T16 2-T16 3-T16 2-T16 3-T20 3-T16 3-T16 2-T16 3-T16 2-T16 2-T16
450
450
450
450
450
450
450
450
450
450
450
450
STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10
2-T16 2-T16 2-T16 2-T16 3-T16 2-T16 2-T16 2-T16 2-T16 2-T16 2-T16 2-T16
SECTION 22-22 SECTION 24-24 SECTION 25-25 SECTION 1-1 SECTION 1-1 SECTION 1-1 SECTION 29-29 SECTION 30-30 SECTION 31-31 SECTION 32-32 SECTION 33-33 SECTION 34-34
(SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25) (SCALE 1:25)
225 225 225
450
450
item description initials date OSHIMILI SOUTH LGA,DELTA STATE. Web-site @ www.Gnad.com.ng 1 : 70
DATE
NOVEMBER,2021
10
39 C E F G' H J
F I' J
38 1 225 225 225 225 225 225 225
1700 2925 1500 1800 2625 1700
A
225 225 225 225
5701 424 600 818 912.5 225
450
2-T16 STP 2L-T10
3-T16
2-T16
450
STP 2L-T10 2-T16
450
STP 2L-T10
10-2L-T10 18-2L-T10 9-2L-T10 11-2L-T10 16-2L-T10 10-2L-T10
2-T16
2-T16
3-T16 2-T16 2-T16
2-T16 2-T16 @165 C/C @165 C/C @165 C/C @165 C/C @165 C/C @165 C/C
SECTION 39-39
952.5 952.5 B37 B3 (SCALE 1:25)
35-2L-T10 SECTION 38-38 SECTION 1-1
@165 C/C B2
3-2L-T10 4-2L-T10 (SCALE 1:25) 39
(SCALE 1:25) C6 C23 C5 C14 C3
@165 C/C @165 C/C
B60:225x450 B61:225x450 B62:225x450 B63:225x450 B64:225x450 B65:225x450
C4 38 C8 1
C39 (SCALE: H = 1:50 / V = 1:50)(SCALE: H = 1:50 / V = 1:50)
(SCALE: H = 1:50 / V = 1:50) H = 1:50 / V = 1:50)
(SCALE: (SCALE: H = 1:50 / V = 1:50)
(SCALE: H = 1:50 / V = 1:50)
B57:225x450 B58:225x450 B59:225x450
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
C 40 C'' B'
41 C C'' 42 G' H B'
43 C C 44 C''
225 225 225 225 225 225 225 225 225 225 225
1800 445 4425 2625 445 1800
450
450
450
450
STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10
2-T16 2-T16 2-T16 2-T16 2-T16
11-2L-T10 2-T16 2-T16 27-2L-T10 16-2L-T10 2-T16 2-T16 11-2L-T10 2-T16
@165 C/C @165 C/C @165 C/C @165 C/C
B29 B22 SECTION 40-40 3-2L-T10 SECTION 41-41 SECTION 42-42 3-2L-T10 SECTION 43-43 SECTION 44-44
(SCALE 1:25) @165 C/C (SCALE 1:25) (SCALE 1:25) @165 C/C (SCALE 1:25) (SCALE 1:25)
40 42 44
41
C34 C31 C26 C15 C11 43
C35 C32 C33 C27
B66:225x450 B68:225x450 B69:225x450 B71:225x450
(SCALE: H = 1:50 / V = 1:50) B67:225x450 (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) B70:225x450 (SCALE: H = 1:50 / V = 1:50)
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
G 45 H C'' 46 F G 47 48
225 225 225 225 225 225 225 225 225 225
2900 2625 1525 3717 858 1623
450
450
450
450
STP 2L-T10 STP 2L-T10 STP 2L-T10 STP 2L-T10
2-T16 2-T16 2-T16 2-T16
18-2L-T10 2-T16 16-2L-T10 9-2L-T10 2-T16 23-2L-T10 2-T16 2-T16
@165 C/C @165 C/C @165 C/C @165 C/C 10-2L-T10
SECTION 45-45 SECTION 46-46 SECTION 47-47 B28
B565-2L-T10 @165 C/C B59 SECTION 48-48
(SCALE 1:25) (SCALE 1:25) (SCALE 1:25) @165 C/C (SCALE 1:25)
45 46 47
C19 C12 C28 C21 C20 C13 C8 48
B72:225x450 B73:225x450 B74:225x450 B75:225x450
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) B76:225x450
B77:225x450
(SCALE: H = 1:50
(SCALE:
/ V = 1:50)
H = 1:50 / V = 1:50)
item description initials date OSHIMILI SOUTH LGA,DELTA STATE. Web-site @ www.Gnad.com.ng 1 : 70
DATE
NOVEMBER,2021
11
1 2 2' 3 4 5 5' 6 7' 7'' 7''' 8 8' 9 9' 10 10'
J 600 1725 1500 3825 1102 1523 1825 1608 1100 2325 3825
B1 B2 B3
C1 C2
I'
B23
I
H
B17
C3
2900
G'''
G'' B4 B5
B22
G' C40 C41 C42
1525
B6 B7 B8
12250
F
C4 C5
B14
B15
2625
E
B16
D
B21
C'' B9 B10
C43 C44
1800
C'
C
B' C6
1700
B20
B
A' B11 B12
B13
B18
A C7 C45
20500
450
STP 2L-T10
450
STP 2L-T10
450
STP 2L-T10
2-T16 2-T16 2-T16 2-T16 2-T16
2-T16
7-2L-T10 30-2L-T10 7-2L-T10 SECTION 1-1 23-2L-T10 23-2L-T10 SECTION 2-2 23-2L-T10 23-2L-T10
@165 C/C @165 C/C @165 C/C @165 C/C @165 C/C (SCALE 1:25) @165 C/C @165 C/C SECTION 4-4
(SCALE 1:25) B16
(SCALE 1:25)
1 2 4
C1 C2 C40 C41 C42 C43 C44
B1:225x450 B2:225x450 B3:225x450 B4:225x450 B5:225x450 B9:225x450 B10:225x450
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
4 3 5 6 8 5 5 7 6 7
225 225 225 225 225 225 225 225
3825 2625 4450 5975 1100 5426
225
225
2-T16 225
2-T16 2-T16
2-T16
2-T16
2-T16
450
STP 2L-T10
450
STP 2L-T10
450
2-T16 STP 2L-T10
2-T16 2-T16 2-T16
2-T16
23-2L-T10 16-2L-T10 27-2L-T10 36-2L-T10 7-2L-T10 2-T16 33-2L-T10
@165 C/C @165 C/C @165 C/C SECTION 3-3 @165 C/C @165 C/C @165 C/C SECTION 6-6
B15 B16 (SCALE 1:25) SECTION 5-5 B18 B19
(SCALE 1:25)
(SCALE 1:25)
3 5 6
C4 C5 C7 C45
B6:225x450 B7:225x450 B8:225x450 B11:225x450 B12:225x450 B13:225x450
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
C 7 G C 8 G 9
A G J
225 225 225 225 225
5025 5025 225 225
8239 4009
450
450
STP 2L-T10 STP 2L-T10 STP 2L-T10
2-T16 2-T16 2-T16
2-T16 2-T16 2-T16
31-2L-T10 31-2L-T10 50-2L-T10 24-2L-T10
@165 C/C SECTION 7-7 @165 C/C SECTION 8-8 @165 C/C @165 C/C SECTION 9-9
(SCALE 1:25) (SCALE 1:25) B1
(SCALE 1:25)
7 8 9
C43 C40 C44 C41
B14:225x450 B15:225x450 C7
B16:225x450
C42
B17:225x450
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
10 A 11 A 12 C F H J
225 225
224 226 225 225 225 225 225
225 1700 4425 4425 1700
225
450
450
2-T16 2-T16 2-T16 STP 2L-T10
2-T16
2-T16
SECTION 10-10 SECTION 11-11 2-T16
(SCALE 1:25) 10-2L-T10 27-2L-T10 27-2L-T10 10-2L-T10
(SCALE 1:25)
B11
2-2L-T10 2-2L-T10 @165 C/C @165 C/C @165 C/C @165 C/C SECTION 12-12
@165 C/C B12 B3
@165 C/C (SCALE 1:25)
10 11 C45 12
C6 C5 C3
B18:225x450 B19:225x450 B20:225x450 B21:225x450 B22:225x450 B23:225x450
(SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50) (SCALE: H = 1:50 / V = 1:50)
30-T1204@200 C/C B.
G'''
18-T1217@200 C/C T. 3 3 6 6 22-T1205@200 C/C B.
10-T1218@200 C/C T.
G''
3-T1206@200 C/C B.
G'
19-T1219@200 C/C B. 5 22-T1207@200 C/C B.
G
8-T1220@200 C/C B. 38-T1208@200 C/C B.
10-T1221@200 C/CFB. 19-T1209@200 C/C B.
35-T1222@200 C/C B. 4 4 5 5 5 6 2 6 7-T1210@200 C/C B.
19-T1223@200 C/C B.
4-T1224@200 C/C T. 2 35-T1211@200 C/C B.
19-T1225@200 C/CEB. 5
D
38-T1226@200 C/C 13-T1212@200 C/C B.
C''B.
3-T1227@200 C/CC'
B.
8-T1213@200 C/C B.
C
4-T1228@200 C/CB'
T.
16-T1214@200 C/C B.
4-T1229@200 C/C B
T. 4
A' 4 8-T1215@200 C/C B.
A
225 225 225 225 225
1875 1495 3595 1165
470 470 375 375 900 900 295 295
T12@200 C/C T12@200 C/C T12@200 C/C T12@200 C/C T12@200 C/C T12@200 C/C T12@200 C/C T12@200 C/C
T12@200 C/C T12@200 C/C T12@200 C/C T12@200 C/C T12@200 C/C
8T12 12 @200C/C 05 07
06
04
SECTOION a-a
03
618
A 21T12 11 @200C/C
5 EQUAL THREADS @ 300 mm= 1500mm
11T12 01 @200C/C
C 8T12 10 @200C/C
01
8T12 02 @200C/C 02
8T12 09 @200C/C
section b-b
BA
12
11 10
23T16 03 @150C/C C
08 09
8T12 09 @200C/C
8T12 04 @200C/C
B section c-c
07 06
3226.1575
9T12 06 @200C/C
notes
1 drawings not to be scaled 5 this drawing is copyright and must not be
PROJECT A
JOB TITLE CONSULTANTS SHEET TITLE
2 written dimensions to be taken in preference
3 dimensions are taken to grid lines and
reproduced without the written permision PROPOSED RESIDENTIAL DEVELOPMENTGNAD ENGINEERING CONSULT STAIRCASE DETAIL & SECTIONS
structural surfaces,not to finished surfaces
of bloomgate ltd.
FOR SHARPTON ENTERPRISES NO 16 DADA ATANRANSE, AGRIC BUS STOP, ENGINEER ENGR. GBADAMOSI SHEET NO.
4 any discrepancies between this drawing 5 authorisation for the use of these drawing revisions AT IKORODU ROAD,LAGOS STATE. DRAWN NURUDEEN
and others or the specification will be is deemed to be given after settlement of
PLOT E,DELTA STATE COMMERCIAL HOUSING SCHEME
brought to the attention of the
architects who alone will decide on final
professional fees. PHONE : (+234)(08039227474)
JUNIOR STAFF QUARTERS CORE AREA ASABA,
CHECKED ENGR. O.O EGHWRUDJE
instruction E-mail :gnadengineeringconsult1@gmail.comSCALE DATE 15
item description initialsdate OSHIMILI SOUTH LGA,DELTA STATE. Web-site @ www.Gnad.com.ng 1 : 70 NOVEMBER,2021